Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #58217599

Tender For Repair / Maintenance Of Water Supply Installations & Distribution Netwrok Of Pump House No 1 Including Plants And Machinery And Cleaning Of Oht And Ug Sumps At Faridkot Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Faridkot, Punjab
Tender Value
45 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
1 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Faridkot → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Water Supply Installations & Distribution Netwrok Of Pump House No 1 Including Plants And Machinery And Cleaning Of Oht And Ug Sumps At Faridkot Mil Stn

BOQ

Name of Work:- REPAIR / MAINTENANCE OF WATER SUPPLY INSTALLATIONS & DISTRIBUTION NETWROK OF PUMP HOUSE NO 1 INCLUDING PLANTS AND MACHINERY AND CLEANING OF OHT AND UG SUMPS AT FARIDKOT MIL STN
Sl. No. Item Description
1Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying pipes and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge
2Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified and directed by Engr-in-Charge
3Removing the excavated soil from the trench n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge
4Attending of complaints water supply and Detection of leakage in main water line by necessary excavation in any type of soil, in any situation/depth including bailing out leakage of water by suitable measures, repair to GI pipe of size 15 mm bore as occurring at Site including cutting threading for addition & alternation and for insertion of fittings/ accessories all as required. Notes : (i) Rate quoted shall be including necessary excavation/ filling making good the existing surfaces with the necessary T&P as required all as directed by the Engineer-in-Charge.(ii) Pipe fittings shall be measured and paid separately as supply only item in the Schedule
5All as per Srl Item No. 04 here-in-before but 20 mm bore complete all as specified and directed by Engr-in-Charge
6All as per Srl Item No. 04 here-in-before but 25 mm bore complete all as specified and directed by Engr-in-Charge
7All as per Srl Item No. 04 here-in-before but 40 mm bore complete all as specified and directed by Engr-in-Charge
8All as per Srl Item No. 04 here-in-before but 50 mm bore complete all as specified and directed by Engr-in-Charge
9Supply only GI Elbow 20 mm bore complete all as specified and directed by Engr-in-Charge
10Supply only GI Elbow 25 mm bore complete all as specified and directed by Engr-in-Charge
11Supply only GI Elbow 40 mm bore complete all as specified and directed by Engr-in-Charge
12Supply only GI Elbow 50 mm bore complete all as specified and directed by Engr-in-Charge
13Supply only GI Union 20 mm bore complete all as specified and directed by Engr-in-Charge
14Supply only GI Union 25 mm bore complete all as specified and directed by Engr-in-Charge
15Supply only GI Union 40 mm bore complete all as specified and directed by Engr-in-Charge
16Supply only GI Union 50 mm bore complete all as specified and directed by Engr-in-Charge
17Supply only GI Socket 20 mm bore complete all as specified and directed by Engr-in-Charge
18Supply only GI Socket 25 mm bore complete all as specified and directed by Engr-in-Charge
19Supply only GI Socket 40 mm bore complete all as specified and directed by Engr-in-Charge
20Supply only GI Socket 50 mm bore complete all as specified and directed by Engr-in-Charge
21Supply only GI Nipple 20 mm bore of length 0.15m complete all as specified and directed by Engr-in-Charge
22Supply only GI Nipple 25 mm bore of length 0.15m complete all as specified and directed by Engr-in-Charge
23Supply only GI Nipple 40 mm bore of length 0.15m complete all as specified and directed by Engr-in-Charge
24Supply only GI Nipple 50 mm bore of length 0.15m complete all as specified and directed by Engr-in-Charge
25Supply only GI Tee 20X20X(20/15) mm bore complete all as specified and directed by Engr-in-Charge
26Supply only GI Tee 25X25X(25/20/15) mm bore complete all as specified and directed by Engr-in-Charge
27Supply only GI Tee 40X40X(40/25/20/15) mm bore complete all as specified and directed by Engr-in-Charge
28Supply only GI Tee 50X50X(50/40/25/20/15) mm bore complete all as specified and directed by Engr-in-Charge
29Taking up or down 15mm bore GI pipe and any type pipe and connections, including all fitting complete all as specified and directed by Engr-in-Charge
30All as per Srl item No. 29 above but 20 mm bore complete all as specified and directed by Engr-in-Charge
31All as per Srl item No. 29 above but 25 mm bore complete all as specified and directed by Engr-in-Charge
32All as per Srl item No. 29 above but 40 mm bore complete all as specified and directed by Engr-in-Charge
33All as per Srl item No. 29 above but 50 mm bore complete all as specified and directed by Engr-in-Charge
34Note for Item No. 34 to 43 : GI fittings included in the rates quoted and hence item No.4 to 28 will not be paid for these item work.S&F 15mm bore GI water Tubing, ISI Marked, 'Medium grade' galvanised, including GI fittings Viz Tees Socket elbows, union nipple etc screwed and socketed joint laid in trenches complete all as specified and directed by Engr-in-Charge
35All as per Srl item No. 34 above but 20 mm bore complete all as specified and directed by Engr-in-Charge
36All as per Srl item No. 34 above but 25 mm bore complete all as specified and directed by Engr-in-Charge
37All as per Srl item No. 34 above but 40 mm bore complete all as specified and directed by Engr-in-Charge
38All as per Srl item No. 34 above but 50 mm bore complete all as specified and directed by Engr-in-Charge
39S&F 15mm bore GI water Tubing, ISI Marked, 'Medium grade' galvanised, including GI fittings Viz Tees Socket elbows, union nipple etc screwed and socketed joint laid in wall and ceiling or laid in floors complete all as specified and directed by Engr-in-Charge
40All as per Srl item No. 39 above but 20 mm bore complete all as specified and directed by Engr-in-Charge
41All as per Srl item No. 39 above but 25 mm bore complete all as specified and directed by Engr-in-Charge
42All as per Srl item No. 39 above but 40 mm bore complete all as specified and directed by Engr-in-Charge
43All as per Srl item No. 39 above but 50 mm bore complete all as specified and directed by Engr-in-Charge
44S & F in repair of 20mm bore Gun-metal, globe or gate valves with iron wheel head screwed both ends for GI pipe complete all as specified and directed by Engr-in-Charge
45All as per Srl item No. 44 above but 25 mm bore complete all as specified and directed by Engr-in-Charge
46All as per Srl item No. 44 above but 40 mm bore complete all as specified and directed by Engr-in-Charge
47All as per Srl item No. 44 above but 50 mm bore complete all as specified and directed by Engr-in-Charge
48Taking up 80mm dia CI water main ( including all fittings) with spigot and socketed ends class LA and lead joints including burning out joints and recovering lead complete all as specified and directed by Engr-in-Charge
49All as per Srl item No. 44 above but 100 mm dia complete all as specified and directed by Engr-in-Charge
50All as per Srl item No. 44 above but 150 mm dia complete all as specified and directed by Engr-in-Charge
51All as per Srl item No. 44 above but 200 mm dia complete all as specified and directed by Engr-in-Charge
52All as per Srl item No. 44 above but 300 mm dia complete all as specified and directed by Engr-in-Charge
53S&F 80mm dia Ductile iron pipe with spigot and socketed ends centrifugally cast Class K7 and bitumenous lining inside including rubber tyton joints laid in trenches complete all as specified and directed by Engr-in-Charge
54All as per Srl item No. 53 above but 100 mm dia complete all as specified and directed by Engr-in-Charge
55All as per Srl item No. 53 above but 150 mm dia complete all as specified and directed by Engr-in-Charge
56All as per Srl item No. 53 above but 200 mm dia complete all as specified and directed by Engr-in-Charge
57All as per Srl item No. 53 above but 300 mm dia complete all as specified and directed by Engr-in-Charge
58Taking up 150mm dia CI water main ( including all fittings) with flanged ends class LA with rubber joints and sets of nuts, bolts and washers complete all as specified and directed by Engr-in-Charge
59All as per Srl item No. 58 above but 200 mm dia complete all as specified and directed by Engr-in-Charge
60S&F 150mm dia Ductile iron pipe with flanged ends centrifugally cast Class K7 and bitumenous lining inside including rubber joints fixed on wall or column including suitable size nuts, bolts and washer complete all as specified and directed by Engr-in-Charge
61All as per Srl item No. 60 above but 200 mm dia complete all as specified and directed by Engr-in-Charge
62S&F CI/DI Fittings up to 150 mm bore i.e bends, any type radius and angle, Straight bend, Tee, Collar, caps and plugs etc complete all as specified and directed by Engr-in-Charge
63S&F CI/DI Fittings 150 mm to 300 mm bore i.e bends, any type radius and angle, Straight bend, Tee, Collar, caps and plugs etc complete all as specified and directed by Engr-in-Charge
64M&L for dismantling, inspection, repair & replacement of damaged parts of sluice valve of 80mm dia like gland packing, seating ring, etc, cleaning, lubrication and reassembly to ensure proper functioning, lapping and polishing of seating surfaces, application of anti-corrosion coating if required, again refixing at same location etc complete all as specified and directed by Engr-in-Charge
65All as per Srl item No. 64 above but 100 mm dia complete all as specified and directed by Engr-in-Charge
66All as per Srl item No. 64 above but 150 mm dia complete all as specified and directed by Engr-in-Charge
67All as per Srl item No. 64 above but 200 mm dia complete all as specified and directed by Engr-in-Charge
68All as per Srl item No. 64 above but 300 mm dia complete all as specified and directed by Engr-in-Charge
69Material and labour including jointing and testing of 80mm dia cast iron sluice valves class PN-1.0, conforming to IS14846 :2000 flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve complete all as specified and directed by Engr-in-Charge
70All as per Srl item No. 69 above but 100 mm dia complete all as specified and directed by Engr-in-Charge
71All as per Srl item No. 69 above but 150 mm dia complete all as specified and directed by Engr-in-Charge
72All as per Srl item No. 69 above but 200 mm dia complete all as specified and directed by Engr-in-Charge
73All as per Srl item No. 69 above but 300 mm dia complete all as specified and directed by Engr-in-Charge
74Supply and Fixing 80mm dia CI non return valve swing type without by pass arrangement, flanged ends, conforming to IS 5312 including nuts, bolts, washers and rubber gaskets, including taking out unserviceable Non Return valve complete all as specified and directed by Engr-in-Charge
75All as per Srl item No. 74 above but 100 mm dia complete all as specified and directed by Engr-in-Charge
76All as per Srl item No. 74 above but 150 mm dia complete all as specified and directed by Engr-in-Charge
77All as per Srl item No. 74 above but 200 mm dia complete all as specified and directed by Engr-in-Charge
78S&F 100mm dia CI foot valve (Flanged) confirming to IS 4038 including jointing with rubber fibre board gasket, nut bolts etc including taking out unserviceable foot valve complete all as specified and directed by Engr-in-Charge
79All as per Srl item No. 78 above but 150 mm dia complete all as specified and directed by Engr-in-Charge
80All as per Srl item No. 78 above but 200 mm dia complete all as specified and directed by Engr-in-Charge
81M & L for Taking proper shut down in writing, disconnecting all the electrical connections, dismantling the motor from the base plate and transporting the same for repair to workshop for rewinding, dismantling the motor/rotor, cutting and removing the old heated up/burnt winding of the Starter/Roter, cleaning the slots, bearing, bushes etc ,rewinding the motor Starter/Roter with super enamelled copper winding wire of existing size , gauge and turns etc including all the insulating materials ie. varnish ,china glass paper, 'F' class insulating paper etc and transportation back the same after winding , reassembling at original position and testing complete of electric motor 100 HP,3 phase,415 volts, AC supply all as specified and directed .Note:-(a) The contractor shall return the motor within week’s time after handing over for repairs to contractor otherwise a penalty of Rs. 1000/- per day for delay period will be charged from the contractor. (b)The rates quoted shall be deemed to include the cost of loading/unloading, transportation, nuts bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed. (c)The contractor shall arrange a visit of Engr-in-Charge to workshop for each job and cutting of complete burnt winding of motor shall be completed in presence of Engr-in-Charge
82All as per Ser item No 81 here-in-before but of capacity 75 HP, complete all as specified and directed by Engineer in Charge.
83All as per Ser item No 81 here-in-before but of capacity 40 HP, complete all as specified and directed by Engineer in Charge.
84All as per Ser item No 81 here-in-before but of capacity 30 HP, complete all as specified and directed by Engineer in Charge.
85All as per Ser item No 81 here-in-before but of capacity 12.5 HP, complete all as specified and directed by Engineer in Charge.
86All as per Ser item No 81 here-in-before but of capacity 10 HP, complete all as specified and directed by Engineer in Charge.
87All as per Ser item No 81 here-in-before but of capacity 5 HP, complete all as specified and directed by Engineer in Charge.
88All as per Ser item No 81 here-in-before but of capacity 2or3 HP, complete all as specified and directed by Engineer in Charge.
89S&F in repair Star Delta Starter, fully automatic, suitable for 100 HP, 415 volts in sheet metal enclosure complete all as specified and directed by Engr-in-Charge
90S&F in repair Star Delta Starter, fully automatic, suitable for 75 HP, 415 volts in sheet metal enclosure complete all as specified and directed by Engr-in-Charge
91S&F in repair Star Delta Starter, fully automatic, suitable for 50 HP, 415 volts in sheet metal enclosure complete all as specified and directed by Engr-in-Charge
92S&F in repair Star Delta Starter, fully automatic, suitable for 10/12.5 HP, 415 volts in sheet metal enclosure complete all as specified and directed by Engr-in-Charge
93S&F in repair Star Delta Starter, fully automatic, suitable for 7.5 HP, 415 volts in sheet metal enclosure complete all as specified and directed by Engr-in-Charge
94S&F in repair Direct On Line Starter, fully automatic, suitable for 5.00 HP, 415 volts in sheet metal enclosure complete all as specified and directed by Engr-in-Charge
95M&L for disconnecting/dismantling, strip opening and overhauling of pumping set of any make and capacity of 100 HP, taking out bearing, bushes, impeller and coupling plates etc and greasing of bearings with superior quality and replacement of brass bushes, slip, impeller grinding, bearing, shaft, gland bush rusted nut bolts and washer, seal etc and lath work on shaft including proper alignment and re-assembling, installing at original position and testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed
96M&L for disconnecting/dismantling, strip opening and overhauling of pumping set of any make and capacity of 75HP, taking out bearing, bushes, impeller and coupling plates etc and greasing of bearings with superior quality and replacement of brass bushes, slip, impeller grinding, bearing, shaft, gland bush rusted nut bolts and washer, seal etc and lath work on shaft including proper alignment and re-assembling, installing at original position and testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engr-in-Charge
97M&L for disconnecting/dismantling, strip opening and overhauling of pumping set of any make and capacity of 40/50 HP, taking out bearing, bushes, impeller and coupling plates etc and greasing of bearings with superior quality and replacement of brass bushes, slip, impeller grinding, bearing, shaft, gland bush rusted nut bolts and washer, seal etc and lath work on shaft including proper alignment and re-assembling, installing at original position and testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engr-in-Charge
98M&L for disconnecting/dismantling, strip opening and overhauling of pumping set of any make and capacity of 25/30 HP, taking out bearing, bushes, impeller and coupling plates etc and greasing of bearings with superior quality and replacement of brass bushes,slip, impeller grinding, bearing, shaft, gland bush rusted nut bolts and washer, seal etc and lath work on shaft including proper alignment and re-assembling, installing at original position and testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engr-in-Charge
99M&L for disconnecting/dismantling, strip opening and overhauling of pumping set of any make and capacity of 10/12.5 HP, taking out bearing, bushes, impeller and coupling plates etc and greasing of bearings with superior quality and replacement of brass bushes, tyre coupling, slip, impeller grinding, bearing, shaft, gland bush rusted nut bolts and washer, seal etc and lath work on shaft including proper alignment and re-assembling, installing at original position and testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engr-in-Charge
100M&L for disconnecting/dismantling, strip opening and overhauling of pumping set of any make and capacity of 5/7.5HP, taking out bearing, bushes, impeller and coupling plates etc and greasing of bearings with superior quality and replacement of brass bushes slip, impeller grinding, bearing, shaft, gland bush rusted nut bolts and washer, seal etc and lath work on shaft including proper alignment and re-assembling, installing at original position and testing to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engr-in-Charge
101M&L for removal of mud and sludge from the Floculator tank including cleaning of internal side of fluculator with proper cleaning material complete all as specified and directed by Engr-in-Charge
102M & L for Site clearance and surface dressing by cutting and removing of elephant/wild grass (sarkanda) from all around the periphery of raw water reservoir and removing from site to a distance not exc 50 m complete all as specified and directed by Engr-in-Charge
103S&F in replacement flexible type coupling containing tread inside, of size TC-15 complete all as specified and directed by Engr-in-Charge
104S&F in replacement flexible type coupling containing tread inside, of size TC-17/TC-19 complete all as specified and directed by Engr-in-Charge
105M & L For Chemical and Bacteriological examination of raw water of the plant at water point No 1 from authorised laboratory complete all as specified and directed by Engr-in-ChargeNote:- Report to be submitted in triplicate.
106M&L for removing/cleaning of mud & sludge upto the bottom of raw water receiving basin of size 11.75 x 7.70 x 3.75 m deep including cleaning of weeds, bushes and vegetation etc inside the tank and upto 3 m distance in surrounding area of raw water basin and disposal of the removed silt/soil to a distance not exc 50 m and depositing where directed at a level n.exc.1.5 m above the starting point complete all as specified and directed by Engr-in-Charge
107All as per Ser item No 106 here-in-before but upto bottom of sludge tank of size 12.00 m dia x 2.75 m deep complete all as specified and directed by Engr-in-Charge
108M&L for removal of mud and sludge from the wells including cleaning of internal side of jack well with proper cleaning material complete all as specified and directed by Engr-in-Charge
109S&F nut and bolts of different sizes including washers to be used for water supply machinery complete all as specified and directed by Engr-in-Charge
110Cleaning of RCC Overhead reservoir of capacity 0.75 to 1.00 Lakh gallon and at approx. 18 mtr staging by scrapping the bottom surface & side walls by brooming with hard wire brush, removal of sludge/mudibilt and other foreign materials from the bottom with the help of buckets & rope manually brought down to the ground level, preliminary washing properly, thereafter washing with concentrated bleaching powder solution (10 1) of water and bleaching powder respectively and disposal of collected sludge mud material to a distance exc. 50 m but not exceeding 100 m from the site including applying a coat of cement base primer and making water supply system functional Date of cleaning shall be written with white paint on the black strip approx size 30x24\\" complete all as specified and directed by Engr-in-Charge
111All as per Srl item No 110 here-in-before but RCC Overhead reservoir of capacity: 0.50 Lakh gallon complete all as specified and directed by Engr-in-Charge
112Supply and fixing CI double air release valve isolating type ( ISI marked ), Flanged type and drilled, confirming to IS -14845, 50 mm bore including jointing material such as nuts, bolts, washers and rubber gasket 3 mm thick at both ends etc including taking out old unserviceable complete all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58217599
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Water Supply Installations & Distribution Netwrok Of Pump House No 1 Including Plants And Machinery And Cleaning Of Oht And Ug Sumps At Faridkot Mil Stn
Basic Detail
Tender No CA NO CWE SGNR/TOKEN-77 OF 2026-27
Bidding Type Tender
Location
City Faridkot
State Punjab
Key Dates
Publish Date 26 Oct 2026
Submission Date 16 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
bc11d7c0-b983-4acb-9aef-cdadc72d8bcd.html
BOQ_892576.xls
Tendernotice_1.pdf
Tender_77.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

bc11d7c0-b983-4acb-9aef-cdadc72d8bcd.html

xls

BOQ_892576.xls

pdf

Tendernotice_1.pdf

pdf

Tender_77.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender