Tender For Special Repairs To External Electrification At Aps Khadki Under Ge (Central) Khadki.
Tender Overview
Project Description
Tender for Special Repairs To External Electrification At Aps Khadki Under Ge (Central) Khadki.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core (Distribution Cable) complete all as specified and as directed. |
| 2 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cables, pole foundation, stays etc and getting out in soft loose soil, complete all as specified and as directed. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed. |
| 4 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.. |
| 5 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cable of size 50 mm outer dia with all fittings such as clamps. coupler etc laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) |
| 6 | Supply and fix vertical distribution Board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB SPN as outgoing 415 Volts 3 phase 50 C/S 4 way, complete with appropriate size copper bus bar and neutral link confirming to cat pt No 607790 of Legrand or equivalent of make Hager / Merlin Gerin multi-9 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. |
| 7 | Supply and Fix MCCB 3 pole 415 Volts, 125 Amps rating with rupturing cap 16 KA complete all as specified and as directed. |
| 8 | Supply and fix MCB SPN, 'C' series. 10 KA, 240 Volts 40-63 Amps capacity complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender