Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #58217571

Tender For Improvement Of Kitchen In Md Accn And Certain Major Revenue And Minor Works At Afs Begumpet Under Ge (Af) Hakimpet(Tender Id No. 2026_Mes_795304_1)

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
43.40 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
1 days left
EMD
86800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Improvement Of Kitchen In Md Accn And Certain Major Revenue And Minor Works At Afs Begumpet Under Ge (Af) Hakimpet(Tender Id No. 2026_Mes_795304_1)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Nov-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-Nov-2026

BOQ

Name of Work:- IMPROVEMENT OF KITCHEN IN MD ACCN AND CERTAIN MAJOR REVENUE AND MINOR WORKS AT AFS BEGUMPET UNDER GE (AF) HAKIMPET(TENDER ID No. 2026_MES_795304_1)
Sl. No. Item Description
1Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified and directed.
2Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed
3M & L 25 mm thick PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) in sub base of floorings complete all as specified and directed
4S&F Non Skid joint free colored ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including screed bed or bedding layer 15mm thick in CM 1:4 complete all as specified and as directed complete all as specified and as directed. Note: Shade and design/pattern of tiles shall be as directed by GE..
5M&L, joint free coloured glazed ceramic tiles of size 300 x 450mm, 6 to 7mm thick in dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick backing coat in CM 1:3 complete all as specified and as directed.
6M&L, 18 to 20mm thick, approved machine cut, coloured Granite, factory polished, edges rounded in steps, cooking platform and the like laid over and including screed bed or bedding layer 20mm thick in cement mortar 1:4, pointing with white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone complete all as specified and directed.
7Taking down and refixing in the same opening after easing & adjusting shutter of size exc 1 sqm and n exc 2 sqm each complete all as specified.
8Demolition of brick work or stone/ boulder or block masonry, built in cement mortar or cement lime mortar including all quoins, pillars etc. complete all as specified and directed
9M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed
10Taking down cement or cement lime plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
11M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 , finished even and smooth (without using extra cement) complete all as specified
12Material and labour PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in copings.complete all as specified and directed
13M&L for Preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
14M&L for complete removal of existing treatment on wall and preparing the surfaces and applying two coats of oil bound distemper over a coat of Alkali resistant Primer on 2 mm thick wall care putty, complete all as specified and directed.
15S&F Mild steel angle/flat iron/chanel framed work such as iron gate, ladder, SWT rame, grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
16M&L Preparing new steel Surfaces of any any description over 10cm width or girth and appling two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete.
17M&L for preparation of old painted surfaces of ceiling and applying one coats of distemper oil emulsion complete all as specified and directed
18M&L for preparation of previously treated wood or wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
19Taking down Chowkats or frames with shutters not exceeding 1.5 Sqm each (Without taking off shutters from the frames)
20Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frame)
21S & F Factory made single extruded WPC(Wood Polymenr Composite) solid door/window/Ceosetory windows and other Frames/chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated witgh miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame densityy of 750 kg/cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), miimum compressive strength of 58 N/mm2, modules of elasticity 900N.mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of requred dia and length complete as per direction of Engineer-in-charge. (M.S hold fast/lugs or SS dash fasteners shall bne paid for separately) manufacturers instructions and as directed by Engineer-in-Charge.
22S & F, 35mm thick, 2nd class hardwood glazed & skelton shutters, open rebated & prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a).
23S&F, 100mm size medium wt cold rolled mild steel butt hinges, medium weight complete all as specified and as directed.
24S&F, 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
25S&F, 300mm long aluminium anodized sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
26S&F, 150mm size, extruded aluminium anodized handles, fabricated type, complete all as specified and as directed.
27S&F, 150mm long (overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor complete all as specified and directed.
28S & F Anodised aluminium Powder coating (minimum thickness of powder coating 50 micron) frame for doors, windows ventilators with one or more rebets including jointing cleats for fixing etc complete all as specified
29S&F powder coated aluminium window shutters powder coating of any colour (Thickness or powder coating not less than 50 micron)., sliding type three track, for fixing wire mesh/glass aluminium section weighing 0.55 kg/Rm including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles and locking arrangement complete all as specified and directed.Note : Wire cloth/glass will be measured and paid seperately under relevant item.
30S&F 4.80mm thick sheet glass ordinary quality fixing with putty/beading in square in each pane complete all as specified and directed
31S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
32Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for complete all as speified..
33M & L for RCC Nominal Mix, Type B1 1:2:4 (using 20mm graded stone aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like work complete all as specified and directed
34Mild steel TMT bars 10 mm dia and over, cut to length, bent ot shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
35Formwork to flat rough finished surfaces of concrete to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work ; not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed
36S&F in repairs, stainless steel sink 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
37S&F stainless steel plate rack of minimum size 970X770X230mm of standard quality,fixed to wall with wooden gutties and screws complete all as specified and directed including taking down old steel plate rack complete all as specified and directed
38S&F 32mm dia PVC waste pipe with fittings for fixing to WHB and kitchen sinks of suitable length as per site requirement and including taking down old waste pipe complete all as specified and directed.
39S&F 100 mm dia brass chromium plated waste coupling fittings for stainless steel kitchen sink etc., with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
40Taking up or down GI tubing incl connections of 20 mm dia bore complete all as specified.
41Cutting chases, in stone walls, pinning in, making good to facing where required and pointing in cement mortpor 1:3 for concealed water tubing and making good, cuting exc, 10 cm but n.exc 20 cm girth.
42Supplying and laying 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. all as specified and directed.
43Demolition and breaking up drain pipes of 75mm dia complete all as specified.
44S&F PVC(SWR) 75mm bore pipes single socketed in any length with rubber ring joints fixed to walls/floor
45S&F PVC (SWR)bend 75mm bore complete all as specified and directed..
46M&L for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement
47S&F Bib taps, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15mm dia and fixed complete all as specified and directed
48S&F SS soap dish holder all as specified and directed.
49S&F external teak wood lipping, 6mm thick, fixed with nails to prelaminated particle board complete all as specified and directed
50S&F of 18mm thick HDMR Board fixed with screws to timber frame work complete
51M&L for 0.9 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions
52S& F auto closing mild steel hinges with spring for , cupboard fixed with nut, screw and washer of mild steel, bright finished complete.
53S&F SS handles, fancy type, 125 mm long complete.
54Demolition of plain cement cement concrete/terrazo tiles with cement mortor bedding in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing the debris outside MOD land all as specified by engineer in charge
55M & L 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in sub base.
56M&L hardcore of broken stones or boulders of guage n exc. 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface.
57M&L Coloured joint free Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match joint free 15 mmm thick screed bed or bedding layer in CM 1:6 as in base to floor finish complete all as specified and as directed.
58M & L PCC (1:4:8) type D-2 using 40 mm graded aggregate as in foundation and mass concrete complete all as specified and as directed.
59M & L for Pre-cast cement concrete block masonry with solid blocks, Type C1 1:3:6 (20mm graded aggregate) exc. 10 cm in width and setting in cement mortar 1:4, complete
60M&L 15mm thick plaster on fair faces of brick surface with CM 1:4 finished fair and even without using extra cement all as specified and directed.
61S&F plates(plain or chequered) channels, square cut or notched (ordinary and counter sunk) Fe-410-W(Gde-E-250) quality B forming holes without any attachment complete all as specified and directed
62S&F Steel work in tubular trusses/Posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240 fitting as directed complete all as directed.
63S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws as specified.
64S&F Pre painted Galvalume aluminium zinc coating GI based plain sheet as in ridge / wall cladding steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws as specified.
65M&L for preparation of new plastered wall surfaces and applying three coats of white wash on walls complete all as specified and as directed.
66Earthwork excvation in trenches with (Soft/loose soil) n exc 1.5m wide and nexc 1.5m in depth for foundation etc or shefts , wells , cess pits, manholes etc n exc 10sqm on plan and n exc 1.5m in depth and getting out all as specified
67Returning filling in including spreading leveling and well ramming in layers n.exc 25 cm thick of soft/loose soil
68Removing excavated material to a distance exc 50m but n.exc 100 m and depositing where directed at a level n.exc 1.50m from starting point.
69M & L for TMT bars for reinforcement 6mm to 8mm dia cut to lengths, bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia
70M & L Form work to sides of Concrete foundation , footings, bases of columns, raft beams and soffits of foundation and plinth beam and similar work vertical or to batter etc with fair finished surfaces of concrete flat all as specified and directed
71M & L Formwork to sides of pillars, posts, struts, column etc rough finishes of concrete surfaces flat of square,rectangular,polygon all as specified and directed
72M & L RCC mix ratio 1:1 1/2: 3 (20mm aggregate) nominal mix in foundation, including rafts, footings, plinth beams, bases for columns etc and mass concrete all as specified
73M& L PCC (1:4:8) Type D2 (using 40mm graded aggregte) in foundations, filling and mass concrete all as specified
74M& L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness , M-35 Grade with grey cement and pigment complete all as specified and directed.
75M&L for Sand filling under floors 50 mm thick in foundations including watering and consolidation all as specified and directed.
76M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
77M&L, pre cast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slabs including necessary form work, placed in position, set in cement mortar (1:4) including dismantling of damaged RCC cover slabs complete all as specified and directed.Note: Reinforcement shall be measured and paid separately.
78M & L 20cmx20cmx25mm/30 cmx30 cmx25 mm thick chequerd cement concrete tiles grey cement with pigment set and jointed in neat cement slurry including 15 mmm thick screed bed or bedding layer in CM 1:6 as in base to floor finish.
79Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed
80Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses,pendants, regulators sockets etc. to be measuredseparately), removing materials to store for keeping in safe custody for reuse at site and making good to disturbed surfaces of walls, floors and roofs by providing white cement/putty match to as existing surface etc. complete all as specified and directed.
81M & L for point wiring with 1.5 sqmm FR grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694 drawn through and including PVC casing and capping/conduit pipe complete with all fittings and acessories including PVC Board/Metal sunken box with white modular cover plates for mounting of switches, sockets, regulators, etc and 1.5 sq mm stranded copper conductor cable FR grade PVC insulated and unsheathed for earth continuity all as specified and directed for One light Point controlled by one one way switch.
82All as per Ser item No 81 above but for One Ceiling /Exhaust Fan Point controlled by one one way switch.
83All as per Ser item No 81 above above but for 5 amps socket point on independent board.
84All as per Ser item No 81 above above but with 2.5 sqmm cable for 15 amps socket outlet on independent board with 2.5 Sqmm earth continuty wire complete all as specified and directed.
85Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body.
86Supply and fix switch modular type, 6 Amps 240 volts single pole one way.
87Supply and fix socket outlet, 5 pin 6 Amps, Modular type.
88Supply and fix socket outlet 6/16 Amps, 6 in 1, Modular type.
89Supply and fix switch modular type,15/16 Amps 240 volts single pole one way.
90Supply and fix 20 watt lumers not less than 110 watt intregated LED tube light fitting 4 ft , suitable for single phase 230 Volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sqmm (nominal area)all as specified.
91S& F in repair Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed (for Kitchen)
92S&F Rechargeable 12W LED bulb B-22 type, CDL/WW with backup complete all as specified and directed.
93Supply & fix exhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed.
94M&L for MCB single pole, 240 volts, 6 - 32 Amps, 10 KA C Curve
95M&L for MCB single pole, 240 volts, 6 - 32 Amps, 10 KA C Curve
96Supply, installation, testing and commissioning of Fan Coil Unit (FCU) type flame proof air-conditioning system of 1.5 TR capacity suitable for operation with existing split air-conditioner outdoor condensing unit, comprising copper tube aluminium fin cooling coil, three-speed blower assembly, washable air filter, insulated casing, drain tray, cordless remote controller, indoor control assembly and all associated accessories complete.
97(a) The FCU shall be specially adapted for Direct Expansion (DX) operation wherein refrigerant from the existing split air-conditioner outdoor condensing unit shall be circulated directly through the cooling coil of the FCU in lieu of conventional chilled water circulation from a central chiller plant. The refrigerant shall absorb heat from return air drawn from the protected room through ducting and deliver cooled air back into the room through separate supply air ducting.(b) The work shall include design, fabrication, supply and installation of supply air and return air ducting fabricated from galvanized iron sheet not less than 0.63 mm thick, complete with bends, elbows, reducers, flanges, dampers, flexible connections, supports, hangers, grilles, diffusers, turning vanes, sealants and all fixing accessories required for proper air circulation.(c) The item shall further include refrigerant grade copper tubing for liquid and suction lines complete with closed-cell elastomeric insulation, control wiring, power wiring, protective PVC conduit, condensate drain piping with fittings and supports, isolation valves, safety devices, vibration isolation pads, clamps, anchor fasteners, MS mounting brackets/supports, cutting and making openings in walls wherever required, sealing and weatherproofing of openings and making good all disturbed surfaces including plastering, painting and finishing to match existing surroundings.(d) The complete system shall be installed in such a manner that the FCU, blower motor, control components and associated electrical equipment remain outside the protected battery room, while conditioned air is supplied and return air extracted through ducting, thereby minimizing fire hazard within the protected space.(e) The scope shall also include pressure testing of refrigerant piping, nitrogen purging during brazing, vacuumisation, refrigerant charging/top-up if required, air balancing, performance testing, trial run, testing and commissioning of the complete installation, submission of test certificates and all labour, materials, tools, tackles, transportation and incidental works necessary for satisfactory operation of the system, complete in all respects and as directed by the Engineer-in-Charge
98S & F timer switch for air conditioner with suitable size enclosure to limit the working of split / window AC of any capacity and make : Creative technology , Model :TT-03 complete all as specified and directed.
99M & L for sub Wiring with two run of 4 Sqmm for phase and one run of single core 4 Sqmm as earth wire of multi stranded copper conductor FR-LSH in metallic conduit insulated unsheathed cable drawn through in & including PVC casing & Caping with fixing accessories on wall / roof surface as per relevant IS standard not less than 25 mm width and all as complete specified and directed.
100S & F industrial type socket with plug top , Single pole and neutral and earth plug 240 V, 20 A with steel enclosure and one MCB SPN 20 Amps complete all as specified and directed.
101Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58217571
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.40 Lakhs
LAST DATE 23-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Improvement Of Kitchen In Md Accn And Certain Major Revenue And Minor Works At Afs Begumpet Under Ge (Af) Hakimpet(Tender Id No. 2026_Mes_795304_1)
Basic Detail
Tender No 8125E8
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 16 Nov 2026
Submission Date 23 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 43.40 Lakhs
Tender Fee 500
EMD 86800
Exemption Available
Document List
8125sch.pdf
8125tenderdocs.pdf
BOQ_892551.xls
c89d95f1-15c5-4baa-a439-260c67be718a.html
summary8125.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
pdf

8125sch.pdf

pdf

8125tenderdocs.pdf

xls

BOQ_892551.xls

html

c89d95f1-15c5-4baa-a439-260c67be718a.html

pdf

summary8125.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender