Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #58217563

Tender For Provisioin Of Ac Points And Connected Works In Certain Smqs At Af Station Gwalior

Issued by Statutory Bodies & Commissions/Committees · Gwalior, Madhya Pradesh
Tender Value
24.20 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
19 days left
EMD
48400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gwalior → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provisioin Of Ac Points And Connected Works In Certain Smqs At Af Station Gwalior

BOQ

Name of Work:- PROVISIOIN OF AC POINTS AND CONNECTED WORKS IN CERTAIN SMQs AT AF STATION GWALIOR
Sl. No. Item Description
1Taking down chowkat or frames with shutter (without taking off shutters from the frames) n.exc 1.5 Sqm each complete all as specified and directed.
2Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
3M& L for Baroda Green Marble slab 15 to 18mm thick for window cill and including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
4S&F powder coated (of approved tint) aluminum frame for door, window, ventilators including joining cleat glazing clip, snap beading, rubber packing, building hardware & screw etc for fixing complete all as specified & directed. Note:- (i) wire mesh and sheet glass shall be measured and paid separately under respective items.(ii) Weight of only aluminium section used for fabrication of door/window shall be measured for payment.
5M&L for powder coated aluminium window and ventilator shutters, three track without sash bar, aluminium section weighing 0.55 kg/m including all necessary hardware, joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. including all necessary hardware complete all as specified and directed.
6M&L for powder coated aluminium window and ventilator shutters, side hung without sash bar,aluminium section weighing 0.55 kg/mincluding all necessary hardware, joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. including all necessary hardware complete all as specified and directed.
7S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
8S & F 4mm thk Sheet glass, ordinary quality in square in not exc 0.5 sq.m in each pane complete all as specified and directed.
9Material and Labour for mild steel framed work such as grills, grating etc with ends of bars shouldered and or riveted into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, cooler platform, frame work of water tanks and similar work including welding conforming to Fe-290 & grade E-165 etc complete all as specified and directed.
10M & L for rendering 15 mm thick on fair faces of brick wall finished even and smooth (without using extra cement ) in CM 1:6 and including taking down cement plaster complete all as specified and directed.
11M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm / liter and UV resistance as per IS15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over new plaster surfaces of walls complete all as specified and directed.
12M&L for preparing new plaster surfaces of Walls and applying two coats of Oil Emulsion over a coat of primer complete all as specified and directed.
13M&L for complete removing existing treatment on wall surface and applying two coats of oil Emulsion over one coat of primer complete all as specified and directed.
14M & L for preparation of new steel Surfaces of any description, over 10cm in width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
15Supply & Fixing 4 Module gang box including Modular socket outlet 16 Amps for AC ,240 volts flush type white finish with MCB 16 Amps type \\"C' flush mounted and LED indicator (RED) including concealed point wiring on wall and surface wiring on ceilling/ roof with necessary arrangments with 4 sqmm single core 1100 volts grade FRLSH PVC insulated unsheathed multistandred copper conductor with and including PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accomodate all the accessories complete with internal connections ,fixed with chromium plate screws and washers for switches and sockets, including 4 sqmm single core 1100 volts grade FRLSH PVC insulated unsheathed multistandred copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls /floors for concealed conduit and making good the distrubed surface by cement mortor (1:3) and to match with the existing surface /colour by using existing oil bound distemper /white wash complete all as specified and directed.
16Supply and fixing of sheet metal enclosure Double door for DB’s 4 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified and directed.
17S&F MCB single pole 6 to 32 Amps, 'B' curve 10 KA, 240 Volts complete all as specified and directed.
18S&F MCB Single pole and neutral 6 to 32 Amps, 'C' curve 240 Volts complete all as specified and directed.
19M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit, med grade of size not less then 20 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FR of size 6 Sqmm as earth continuity conductor all as specified and directed.Note:- Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
20M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including one 15Amps switch with socket ,Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for One 15 Amps socket outlet on independent board. General Note:- (a) For Lights points one circuit maximum 08 points. (b) For same board 6 Amps socket not more than 2 x 6 Amp sockets in one circuit for light point. (c) For Socket outlet Ind 6 Amps ( One circuit with maximum 4 points).(d) For Socket outlet 16 Amps ( One circuit of one point only).
21Disconnecting, taking out carefully and removing old existing underground, LT cable of any type and in any position complete including taking out protection pipe and seviceable bricks/ cable covers and stack up at the site properly for reuse all as specified and directed for the following sizes:
2225 Sqmm to 70 Sqmm 3½ core
2395 Sqmm to 185 Sqmm 3½ core
24Laying, jointing and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminium conductor cable 1100 volts grade of any type laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :-
2525 Sqmm to 70 Sqmm 3½ core
2695 Sqmm to 185 Sqmm 3½ core
27Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade of size 3½ core 240 Sqmm complete all as specified and directed.
28Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade of size 3½ core 95 Sqmm complete all as specified and directed.
29Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored, electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade of size 3½ core 35 Sqmm complete all as specified and directed.
30Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable etc. all as specified and directed including taking out existing cable protection brick cover etc.
31Returning, filling in, including spreading levelling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed
32Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
33M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.
34Laying only old retrieved serviceable bricks/cable covers for cable protection as obtained from dismantling of the existing cable complete all as specified and directed.
35Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable complete all as specified and directed.
36Supply & Fix 80 mm bore light grade galvanized iron tubing ISI marked including all fittings etc laid in trenches or fixed on wall floor in GI pipe complete all as specified and directed.
37Supply & Fix 50 mm bore light grade galvanized iron tubing ISI marked including all fittings etc laid in trenches or fixed on wall floor in GI pipe complete all as specified and directed.
38Boring of holes under road, pavement, hard standing by mannual borring and including supply and laying insertion of HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58217563
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24.20 Lakhs
LAST DATE 16-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provisioin Of Ac Points And Connected Works In Certain Smqs At Af Station Gwalior
Basic Detail
Tender No 8634/E8
Bidding Type Tender
Location
City Gwalior
State Madhya Pradesh
Key Dates
Publish Date 26 Oct 2026
Submission Date 16 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 24.20 Lakhs
Tender Fee 500
EMD 48400
Exemption Available
Document List
6441b80a-1e34-405d-8596-a71358a57100.html
BOQ_892524.xls
TENDER8634.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

6441b80a-1e34-405d-8596-a71358a57100.html

xls

BOQ_892524.xls

pdf

TENDER8634.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender