Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58217562

Tender For Repair /Maint Of Motor, Control Panel, Valve Pit, Starter And All Connected Items At Af St Utarlai

Issued by Statutory Bodies & Commissions/Committees · Barmer, Rajasthan
Tender Value
15 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
20 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair /Maint Of Motor, Control Panel, Valve Pit, Starter And All Connected Items At Af St Utarlai

BOQ

Name of Work:- REPAIR /MAINT OF MOTOR, CONTROL PANEL, VALVE PIT, STARTER AND ALL CONNECTED ITEMS AT AF ST UTARLAI
Sl. No. Item Description
1Taking down old U/S aviation obstruction light from OH tank of staging upto 20 mtrs and Supply and fix aviation light for high-rise building, towers and chimneys etc. Its UV protected red color unique design make it visible from all the angles and distant places. red colour power consumption upto 25 W IP 65 polycarbonate glass for 360 degree illumination complete all as specified and directed by Engineer - in - Charge
2M&L in replacement earthing complete with G I earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 32 x 6 mm size by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 15 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC type C1 chamber , cast iron chamber frame & cast iron pit cover , heavy duty funnel all as directed . Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
3M&L for Construction of brick masonry valve pit, in repair, of internal size 100cm x 100cm x 90cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock incl demolition of existing valve pit complete all as specified and directed by Engineer - in - Charge Note :- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds.(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Depth of valve pit shall be reckoned from the top of PCC in foundation.
4All as per Srl item No 3 above but internal size 120cm x 120cm x 90cm
5Repair/remarking to existing scale and indicator (water level indicator of RCC UG reservoir or over head reservoir) with synthetic enamel paint as per colour code and as directed by Engr-in-Charge.
6Replacement of PVC floats of size 300mm with pvc wire, red paiting iron plate as per existing size including changing of nilon rope etc complete as directed in all RCC over head reservoir or UG reservoir.
7Supply, Installation,Testing and Commissioning of Ultrasonic Level Transmitter at Sump for measurement of level with following specification:- Range : 0-8 meters Accuracy : 0.5 % minimum ,Supply Voltage : 24V DC,Output : 4-20 mA , 0-10V DC incl taking down old u/s level transmitter
8Supply, Installation Testing & Commissioning of Outdoor type having Canopy and Double Door for weather protection, PLC ( Programmable Logic Controller) based Automation, Protection Panel suitable for control and monitoring of 01 Nos. Ultrasonic Sensor. The panel should be of minimum size 600(H) X 600(W) X 250(D) mm fabricated from 3.15 mm CRCA Sheet incl taking down u/s panel The Panel should comprise the following functions & items:-(a) Water Level Sensing & Display(ii) 01 No. PLC with follwing specifications:- (MAKE:- SCHNEIDER/SIEMENS/L&T/PHOENIX CONTACT)(a). Non isolated RS 485 communication port or Ethernet communication port.(b). Suitable No. of digital / analog input and outputs.(c). Programming software based on IEC to facilitate building of custom build function blocks.(iii) 01 No. HMI - 7\\" Graphical Touch screen display (Make: SCHNEIDER / SIEMENS/ L&T/ PHOENIX CONTACT)(a). Should have 01 No. RS 485 and 01 No. USB programming port.(b). Should have USB downloading port.(c). Support external data storage on a USB memory stick for storing production data and backing up applications(iv) 01 No. SMPS of 1.5A rating as suitable according to panel design. (Make: SCHNEIDER / OMRON / PHOENIX CONTACT / TTPL)(vii) MCB rating 6-10A. (Make:- L&T/ Schneider/ABB)(viii) Indicator lamp :- As per requirement (Make:- Schneider/ ESBEE/ABB)
9Supply, Installation, Testing and Commissioning of 4 pair CAT 6 UTP armoured cable for Communication incl taking down u/s cable Make : D Link/ KEI/ Polycab/Havells/Digisol
10M&L for rewinding of openwell submerssible pump motor of capacity 12.5/10.0 HP from pit/sump by disconnecting and mechanically by all electrical and pipe connections complete with replacement of old unserviceable burnt insulated copper wire and rewinding complete with same guage of submerssible insulated wire and testing complete with refitting on site all as per site requirement or as directed by EIC Note-Rates are inclusive of Old U/s copper winding and u/s sparesMake of winding wire : - Devidayal / ChetakNote : - (i) Bearing if required for replacement shall be paid seprately (ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account.
11M&L for rewinding of openwell submerssible pump motor of capacity 7.5 HP from pit/sump by disconnecting and mechanically by all electrical and pipe connections complete with replacement of old unserviceable burnt insulated copper wire and rewinding complete with same guage of submerssible insulated wire and testing complete with refitting on site all as per site requirement or as directed by EIC Note-Rates are inclusive of Old U/s copper winding and u/s sparesMake of winding wire : - Devidayal / ChetakNote : - (i) Bearing if required for replacement shall be paid seprately (ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account.
12M&L for rewinding of openwell submerssible pump motor of capacity 3.0 HP from pit/sump by disconnecting and mechanically by all electrical and pipe connections complete with replacement of old unserviceable burnt insulated copper wire and rewinding complete with same guage of submerssible insulated wire and testing complete with refitting on site all as per site requirement or as directed by EIC Note-Rates are inclusive of Old U/s copper winding and u/s sparesMake of winding wire : - Devidayal / ChetakNote : - (i) Bearing if required for replacement shall be paid seprately (ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account.
13All as per serial item No. 12 here-in-above but motor of capacity 2 /1 HP
14S&F in repair DOL starters in sheet steel enclosure AC-3 duty,415 V, suitable for upto 5.0 HP motor and relay range capacity 5-10 A, all as directed by EIC. Make- L&T or Equivalent
15S&F in repair single phase DOL motor starter 1 HP (6-10A),220 Volts(AC) equipped with comprehensive safeguards including dry run,undervoltage and overload protection for motor safety all as directed by EIC
16S&F in repair fully automatic star delta starters in sheet steel enclosure AC-3 duty,415 V, suitable for upto 15 HP motor and relay range 14-23 A all as directed by Engr-in-Charge Make- L&T or Equivalent
17M & L for painting of old pipe line of DI or GI surfaces of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint complete with showing arrow in water flowing direction in white colour
18S&F 100 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete including taking down all as specified and directed by Engineer-in-charge.
19Supply and fix NRV of 100 mm with all fittings and fixed complete to existing line including taking out old u/s NRV as specified and directed by Engr-in-charge
20M&L for plain cement concrete 1:3:6 type C-2 (using 20mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of stay assembly complete all as specified.
21Preparation of old painted steel surfaces of panel body of any size incl scrapping old paint, denting and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
22Supply and fix in repair pressure gauge 4 inch dial water meter of pressure range 0-14 kg/Sqcm complete all as specified and directed by Engineer-in-charge.
23S & F in replacement 65mm PVC spiral ribbed hose pipe withstand high pressure all as specified and directed by engineer-in- charge.
24S & F in replacement 80mm PVC spiral ribbed hose pipe withstand high pressure all as specified and directed by engineer-in- charge.
25S & F in replacement 150mm PVC spiral ribbed hose pipe withstand high pressure all as specified and directed by engineer-in- charge.
26S & F in replacement 65mm PVC pipe connector for connecting hose pipe as per sample all as specified and directed by engineer-in- charge.
27S & F in replacement 80mm PVC pipe connector for connecting hose pipe as per sample all as specified and directed by engineer-in- charge.
28S & F in replacement 150mm PVC pipe connector for connecting hose pipe as per sample all as specified and directed by engineer-in- charge.
29S&F as in repair Rotational moulded polyethylene water storage tanks -1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified.
30S & F of schmatic diagram with wooden framing of pump house with mentioning all pipe lines and sumps on flexi banner of all as specified and directed by engineer-in- charge.
31Decarburizing/cleaning complete of Pumpset panel by cleaning bus bar chamber with suitable chemical and ensure proper decarburizing, internal wiring and replacing the damaged wires of existing size, refixing the same after applying suitable solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/out-going system complete incl replacement of defective rusted bolts & nuts, repairing to door/ shutter hinges and locking arrangements all a directed by Engr-in-Charge all as specified and directed.
32S&F as in replacement coupling assembly as per existing model & make suitable for centrifugal pump set assembled with 40 HP motor complete all as specified & as directed by Engineer –in-charge.
33All as per serial item No. 32 here-in-above but assembled with 20 HP motor
34Supply and laying in replacement rubber mat of size 2 m x 1 m x 19mm thick complete all as specified and directed by Engineer-in-charge.
35S&F in replacement fully automatic star delta starter type for 75 HP having relay of range 45 A - 100 A including making electrical connection and fixing at existing LT panel or wall with fittings complete all as specified & as directed by Engineer-in-charge
36Material and labour for repairing/servicing the Electric induction motor and centrifugal pump carefully disconnecting the connection cables and earthings, removing side covers, greasing wherever necessary, changing of defective minor parts and re-assembling, testing of capacity 50 to 75 HP all as specified and directed by engineer-in- charge.
37S&F in replacement MCCB 3 Pole 25-100 Amps, thermal magnetic release having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge.
38S&F in replacement MCCB 4 Pole 100-200 Amps, thermal magnetic release having, breaking capacity 36 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58217562
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 15 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair /Maint Of Motor, Control Panel, Valve Pit, Starter And All Connected Items At Af St Utarlai
Basic Detail
Tender No 8168/E8
Bidding Type Tender
Location
City Barmer
State Rajasthan
Key Dates
Publish Date 26 Oct 2026
Submission Date 18 Nov 2026
Open Date 20 Nov 2026
Finance
Tender Value 15 Lakhs
Tender Fee 500
EMD 30000
Exemption Available
Document List
63f05abd-2c67-4194-a47e-4897cbb02384.html
BOQ_892507.xls
Tenderdocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

63f05abd-2c67-4194-a47e-4897cbb02384.html

xls

BOQ_892507.xls

pdf

Tenderdocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender