Bids Are invited for Dsetc Of 50M Ss Tower At Akashvani Jiribam - Supply Of 50M Tower Superstructure Materials Including Fabrication, Galvanizing As Per Akashvani Specification Complete As Required. #Quantity In Metric Ton (Mt) Offered To Be Mentione
Tender Overview
Project Description
Bids Are invited for Dsetc Of 50M Ss Tower At Akashvani Jiribam - Supply Of 50M Tower Superstructure Materials Including Fabrication, Galvanizing As Per Akashvani Specification Complete As Required. #Quantity In Metric Ton (Mt) Offered To Be Mentioned By Tenderer. , Accessories , Submission Of Working Structural Drawings Of 50M Tower (For Foundation And Tower Structure) As Per Air Specification To:A) Air Station -1 Setb) Zonal Office -1 Setc) Dg: Air -1 Set , Submission Of Certified Inspection Report For Structural Safety & Firmness, Verticality And All Other Design Specifications By Iits, Nits Or Any Of The Recognized Govt. Institution(S) After Erection Of Tower To Zonal Adg (E). , Submission Of Completion Report (Soft & Hard Copies) Including Photographs Showing Complete Tower As Well As Each Section Of 20 M Length From Base To Top, Horizontal Cable Tray And Foundation Processes Starting Of Excavation, Steel Layout And Reinforcements Etc. To Leveled Finished Foundation To:A) Air Station -1 Setb) Zonal Office -1 Setc) Dg: Air -1 Set , Any Other Items Required For The Completeness Of The System. Items Wise Details (Including Part No., If Any) Are To Be Given By The Tenderer. , Design Of 50M Tower & Foundation As Per Air Specifications And Submission Of Serc/Iit Approved Design Documents And Design Drawings (Soft & Hard Copies) Duly Signed & St Ed By Competent Authority And Working Structural Drawings Of 50M Tower (For Foundation And Tower Structure) As Per Air Specification To Zonal Adg (E) , Erection, Testing And Commissioning Of 50 M Self Supporting Lattice Steel Tower At Site As Per Air Specification Complete As Required , Casting Of Tower Foundation Including Supply Of Complete Raw Materials, Hardware, Labour, Site Clearance Etc. As Per Air Specification Complete As Required. , Soil Testing With Detailed Report & Document. , Fixing Of Led Based Aviation Obstruction Lights Along With Cable &Mcb Complete As Required. , Painting Of Tower Including Paint Materials Complete As Required. , Earthing Work For Tower (4 Nos, Earthing) Complete As Per Air Specification , Tower Lightning Arrester Installation Work Complete As Required. , Fixing Of 100 Mm Inner Dia. Class C, Seamless Gi Pipe Of 18 M Length For Mounting Provisions For Vhf Fm Antenna Complete As Required. , Fixing Of Vertical Ladder With Free Fall Prevention System Complete As Required. , Fixing Of Vertical Cable Tray With Cl S Complete As Required. (Rate Per Meter Shall Be Quoted) , Fixing Of Horizontal Cable Tray With Cl S Complete As Required. (Rate Per Meter Shall Be Quoted) , Laying Of Power Supply Cable And Fixing Of Weather Proof Metal Boxes With Multipoint Power Sockets And Switches At Base And Each Platforms, Fixing Of 32 A, Sp&N, Mcb Including Connections, Testing Etc. Complete As Required. , Pre-Dispatch Inspection Of Tower Materials At The Works Of Oem/Tower Manufacturer , Additional Charges For Reduced Soil Bearing Capacity Below 8.2 Mt/Sq. M For Every 0.55 Mt/Sq. M Decrease. , Any Other Works Required For The Completion Of Dsetc. Break Up Details Of Work Are To Be Given By The Tenderer. , Hoisting Of Vhf Fm Antenna & Laying Of Rf Coaxial Cable As Required.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supply of 50M tower superstructure materials including Fabrication, Galvanizing as per Akashvani Specification complete as required. #Quantity in Metric Ton (MT) offered to be mentioned by tenderer. | Supply of 50M tower superstructure materials including Fabrication, Galvanizing as per Akashvani Specification complete as required. #Quantity in Metric Ton (MT) offered to be mentioned by tenderer. |
| 2 | ACCESSORIES | ACCESSORIES |
| 3 | Submission of working structural drawings of 50M tower (for foundation and tower structure) as per AIR specification to:a) AIR Station -1 setb) Zonal Office -1 Setc) DG: AIR -1 Set | Submission of working structural drawings of 50M tower (for foundation and tower structure) as per AIR specification to:a) AIR Station -1 setb) Zonal Office -1 Setc) DG: AIR -1 Set |
| 4 | Submission of certified inspection report for structural safety & firmness, verticality and all other design specifications by IITs, NIT's or any of the recognized Govt. Institution(s) after erection of tower to Zonal ADG (E). | Submission of certified inspection report for structural safety & firmness, verticality and all other design specifications by IITs, NIT's or any of the recognized Govt. Institution(s) after erection of tower to Zonal ADG (E). |
| 5 | Submission of Completion Report (soft & hard copies) including photographs showing complete tower as well as each section of 20 M length from base to top, horizontal cable tray and foundation processes starting of excavation, steel layout and reinforcements etc. to leveled finished foundation to:a) AIR Station -1 setb) Zonal Office -1 Setc) DG: AIR -1 Set | Submission of Completion Report (soft & hard copies) including photographs showing complete tower as well as each section of 20 M length from base to top, horizontal cable tray and foundation processes starting of excavation, steel layout and reinforcements etc. to leveled finished foundation to:a) AIR Station -1 setb) Zonal Office -1 Setc) DG: AIR -1 Set |
| 6 | Any other items required for the completeness of the system. Items wise details (including part No., if any) are to be given by the tenderer. | Any other items required for the completeness of the system. Items wise details (including part No., if any) are to be given by the tenderer. |
| 7 | Design of 50M tower & foundation as per AIR specifications and Submission of SERC/IIT approved design documents and design drawings (soft & hard copies) duly signed & stamped by competent authority and working structural drawings of 50M tower (for foundation and tower structure) as per AIR specification to Zonal ADG (E) | Design of 50M tower & foundation as per AIR specifications and Submission of SERC/IIT approved design documents and design drawings (soft & hard copies) duly signed & stamped by competent authority and working structural drawings of 50M tower (for foundation and tower structure) as per AIR specification to Zonal ADG (E) |
| 8 | Erection, Testing and Commissioning of 50 M Self Supporting Lattice Steel tower at site as per AIR specification complete as required | Erection, Testing and Commissioning of 50 M Self Supporting Lattice Steel tower at site as per AIR specification complete as required |
| 9 | Casting of tower foundation including Supply of complete raw materials, hardware, labour, site clearance etc. as per AIR specification complete as required. | Casting of tower foundation including Supply of complete raw materials, hardware, labour, site clearance etc. as per AIR specification complete as required. |
| 10 | Soil testing with detailed report & document. | Soil testing with detailed report & document. |
| 11 | Fixing of LED based Aviation Obstruction Lights along with cable &MCB complete as required. | Fixing of LED based Aviation Obstruction Lights along with cable &MCB complete as required. |
| 12 | Painting of tower including paint materials complete as required. | Painting of tower including paint materials complete as required. |
| 13 | Earthing work for tower (4 Nos, earthing) complete as per AIR specification | Earthing work for tower (4 Nos, earthing) complete as per AIR specification |
| 14 | Tower Lightning Arrester installation work complete as required. | Tower Lightning Arrester installation work complete as required. |
| 15 | Fixing of 100 mm inner dia. Class 'C', seamless GI pipe of 18 M length for mounting provisions for VHF FM Antenna complete as required. | Fixing of 100 mm inner dia. Class 'C', seamless GI pipe of 18 M length for mounting provisions for VHF FM Antenna complete as required. |
| 16 | Fixing of Vertical ladder with Free Fall Prevention System complete as required. | Fixing of Vertical ladder with Free Fall Prevention System complete as required. |
| 17 | Fixing of Vertical Cable Tray with clamps complete as required. (Rate per meter shall be quoted) | Fixing of Vertical Cable Tray with clamps complete as required. (Rate per meter shall be quoted) |
| 18 | Fixing of Horizontal Cable Tray with clamps complete as required. (Rate per meter shall be quoted) | Fixing of Horizontal Cable Tray with clamps complete as required. (Rate per meter shall be quoted) |
| 19 | Laying of Power Supply Cable and fixing of weather proof metal boxes with Multipoint Power sockets and switches at base and each platforms, fixing of 32 A, SP&N, MCB including connections, testing etc. complete as required. | Laying of Power Supply Cable and fixing of weather proof metal boxes with Multipoint Power sockets and switches at base and each platforms, fixing of 32 A, SP&N, MCB including connections, testing etc. complete as required. |
| 20 | Pre-dispatch inspection of tower materials at the works of OEM/tower manufacturer | Pre-dispatch inspection of tower materials at the works of OEM/tower manufacturer |
| 21 | Additional charges for reduced soil bearing capacity below 8.2 MT/Sq. M for every 0.55 MT/Sq. M decrease. | Additional charges for reduced soil bearing capacity below 8.2 MT/Sq. M for every 0.55 MT/Sq. M decrease. |
| 22 | Any other works required for the completion of DSETC. Break up details of work are to be given by the tenderer. | Any other works required for the completion of DSETC. Break up details of work are to be given by the tenderer. |
| 23 | Hoisting of VHF FM Antenna & laying of RF Coaxial Cable as required. | Hoisting of VHF FM Antenna & laying of RF Coaxial Cable as required. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender