Tender For Certain Repairs To Security Wall, Covered Shelter Of Footpath And External Painting To Compound Wall And Bunkers Of Inidan Maritime Museum At installation Dronacharya
Tender Value
14.98 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
16 days left
EMD
29960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Certain Repairs To Security Wall, Covered Shelter Of Footpath And External Painting To Compound Wall And Bunkers Of Inidan Maritime Museum At installation Dronacharya
BOQ
| Sl. No. | Item Description |
| 1 | Providing and applying anti-carbonation protective coating system to exposed RCC/concrete and plastered surfaces, consisting of one coat of water-based elastomeric waterproofing primer and two coats of single-component acrylic elastomeric anti-carbonation coating, including surface preparation by scraping with putty knife and grinding with mechanical power tools to remove cement slurry, dirt, dust and loose particles, high-pressure jet washing to remove dust, algae and fungal growth, filling of voids, pinholes and honeycombs with cement-based wall putty, application of primer at a spread rate not exceeding 4.0 sqm per litre per coat and anti-carbonation coating at a spread rate not exceeding 3.1 sqm per litre for two coats, all as per manufacturer’s recommendations, including providing, erecting, shifting and dismantling necessary scaffolding and/or cradles, hoisting and lowering of materials, and making good all damages, complete all as specified and directed, for heights up to four storeys.MAKE : Asian Paints (Apcorep Anticarbonation coating) + Damp Proof Ultra water proofing primer and equivalent in Fosroc/Sika/Dr Fixit (Pidilite). |
| 2 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed, |
| 3 | M&L for RCC 1:2:4 nominal mix, type B1 (using 20mm graded stone aggregates) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, chajja, kitchen platforms & shelves etc complete all as specified and directed. |
| 4 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for flat rough finished surface of concrete complete all as specified and directed. |
| 5 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontalor sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed. |
| 6 | M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slab, shelves etc, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 7 | Rendering 5 mm thick in cement mortar (1:3) to fair faces of brickwork or concrete surfaces, such as soffits of RCC roof slabs, beams and the like, at all heights and levels, finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L White washing three coats on new ceiling surfaces including preparation of surfaces complete all as specified and directed. |
| 9 | Demolition of brick masonry built in cement mortar or cement lime mortar etc. complete all as specified and directed. |
| 10 | Masonry with precast cement concrete 1:3:6, type C1 (20 mm graded stone aggragate) solid blocks, exc. 10 cm in width and setting in CM 1:6 etc. complete all as specified and directed. |
| 11 | M&L for rendering 15 mm thick in two coats (5 mm thick in cement mortar 1:4 with water proofing compound over 10 mm thick plaster in CM 1:4) on fair faces of brick work or concrete blocks surfaces finished even and smooth without using extra cement (Note- water proofing compound shall be measured and paid seperately) complete all as specified and directed. |
| 12 | M&L for Finishing walls with Acrylic Smooth exterior weather proof paint of required shade work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) new prepared plastered external surfaces and including scafoldings and cradles including hoisting and lowering as required with bracing , support complete all as specified. |
| 13 | Spply only water integral proofing compound as per manufacturer's instuctions. |
| 14 | Demollition of Cement concrete (unreinforced) n exc 15 cm thickness (below or above ground floors) complete all as specified and directed . |
| 15 | M&L Cement concrete 1:3:6 (using 40 mm aggragate) 100 mm thick type C-2 as in sub base of floor complete all as specified and directed . |
| 16 | Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles to store and rubbish off the premises etc. complete all as specified and directed . |
| 17 | M&L 15 mm thick screed bedding layers in cement mortar 1:6 for laying floor finishes tiles etc. complete all as specified and directed. |
| 18 | M&L for Non-skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade etc. complete all as specified and directed.ed. |
| 19 | M&L for Rendering 10 mm thick in CM 1:4 on brick or concrete surfaces, finished fair and even for receiving wall tiles etc. complete all as specified and directed. |
| 20 | M&L for glazed ceramic tiles, coloured of size 7 mm thick area of each tile exceeding 0.12 sqm but not exceeding 0.18 sqm as in dado/skirting and riser to steps and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 21 | M&L for 10 mm thick plastering in CM 1:6, on internal walls finished even and smooth w/o using extra cement etc complete all as specified and directed. |
| 22 | M&L for preparation of new plastered surface of wall and applying two coats acrylic emulsion distemper over a coat of primer over two layers of wall care putty etc. complete all as specified and directed. |
| 23 | Providing and applying fibre-reinforced, single-component, acrylic–polyurethane elastomeric, solar-reflective liquid-applied waterproofing system to roof terrace slabs consisting of the following, all as per manufacturer’s recommendations:(a) thorough cleaning of the slab surface including removal of loose screed, dust, laitance and other deleterious material, and sealing of the junction of rainwater pipe outlets with the slab all round with polyurethane sealant;(b) providing and laying coving of approximately 75 mm radius at the junction of the slab and parapet walls in cement mortar 1:4 admixed with SBR latex bonding admixture at the dosage recommended by the manufacturer;(c) applying one coat of water-based primer, compatible with the waterproofing coating, on the prepared surface at the coverage recommended by the manufacturer;(d) after the primer has dried, applying the first coat of the waterproofing coating by brush or roller, and embedding a layer of alkali-resistant glass fibre or polyester reinforcing mesh of not less than 45 gsm in the wet coat with overlaps of not less than 75 mm;(e) applying the second coat of the waterproofing coating over the mesh so as to fully cover it, achieving a total consumption of not less than 1.2 kg/sqm and a total dry film thickness of not less than 1.0 mm for the complete system;(f) carrying the complete system up the parapet walls to a height of 300 mm above the finished roof level or as recommended by the manufacturer, whichever is more;including hoisting of materials, curing, water ponding test, and making good all damages, complete all as specified and directed by the Engineer-in-Charge.Make : Fosroc/ Bostik/ Sika/ Asian Paints |
| 24 | 75 mm thick PCC type D- 2, 1:4:8 (40 mm graded aggregate) as in sub base of floor complete all as specified and directed. |
| 25 | M&L Screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 26 | M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors complete all as specified and directed. |
| 27 | M&L for providing cement concrete 1:2:4 type B0 (12.50 mm aggregate) as in mud stops,rounded or chamfered edges complete all as specified. |
| 28 | Taking down chowket /frame without taking off shutter from the frame exc 1.50 Sqm and n.exc 4 Sqm each including complete accessories of any type complete all as specified and directed |
| 29 | Supply and fix powder coated aluminium frame for doors/windows/ventilators minimum thickness of powder coating is 50 microns with one or more rebates etc as in windows/ ventilators including necessary joining cleat, glazing clips, rubber neoprene packing, complete all as specified and directed. Note Glass shall be paid separately under relevant items. |
| 30 | Supply and fix powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos and 03 nos of hinges in each door, hinges, powder coated aluminum snap beading screws etc. complete all as specified and directed. |
| 31 | S/F 4.80 mm thick sheet tinted glass ordinary quality and glazing with aluminium clip square exc 0.5 sqm in each pane, all as specified and directed. |
| 32 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similarpattern roofcoverings complete all as specified and directed |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 34 | S&F Steel work in tubular trusses including pulins, plates, special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 35 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding towall, fixed with self tapping screws to required shape complete all as specified. |
| 36 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in soft loose soil , returning,filling in and ramming earth or broken rubble mixed withearth around, in layers not exceeding 25 cm,and making good the surface complete all as specified and directed. |
| 37 | PCC (1:3:6) type C-2(40 mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 38 | M&L Painting to steel surface exc 10cm width or girth with two coats of synthetic enamel paint over a coat of red oxide primer primer complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender