Tender For General-Guest House-Re-Insulation Of Chiller Pipe Line At Ground Floor At Guest House, Thycaud Tvpm-Maintenance Work-Electrical Ac Work
Tender Value
4.23 Lakhs
Estimated cost
Bid Submission
04 Nov 2026
2 days left
EMD
10591
Bank guarantee accepted
Document Fee
935
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Guest House-Re-Insulation Of Chiller Pipe Line At Ground Floor At Guest House, Thycaud Tvpm-Maintenance Work-Electrical Ac Work
BOQ
| Sl. No. | Item Description |
| 1 | Maintenanace |
| 2 | 16.1.8:Supplying, laying /fixing, testing and commissioning of following nominal size of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass pipe section insulation covered with a layer of 120gm/sqm polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS: 1322 as amended up to date) at joints and repairing of damage to building etc. as per specifications and as required.Note: The Pipes of sizes 150 mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589,from minimum 6.35 mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick fiber glass insulation) |
| 3 | 16.1.9:Supplying, laying /fixing, testing and commissioning of following nominal size of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass pipe section insulation covered with a layer of 120gm/sqm polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS: 1322 as amended up to date) at joints and repairing of damage to building etc. as per specifications and as required.Note: The Pipes of sizes 150 mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589,from minimum 6.35 mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 80mm dia. (50mm thick fiber glass insulation) |
| 4 | 16.1.10:Supplying, laying /fixing, testing and commissioning of following nominal size of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass pipe section insulation covered with a layer of 120gm/sqm polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS: 1322 as amended up to date) at joints and repairing of damage to building etc. as per specifications and as required.Note: The Pipes of sizes 150 mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589,from minimum 6.35 mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 65mm dia. (50mm thick fiber glass insulation) |
| 5 | 16.1.11:Supplying, laying /fixing, testing and commissioning of following nominal size of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass pipe section insulation covered with a layer of 120gm/sqm polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS: 1322 as amended up to date) at joints and repairing of damage to building etc. as per specifications and as required.Note: The Pipes of sizes 150 mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589,from minimum 6.35 mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick fiber glass insulation) |
| 6 | 16.1.14:Supplying, laying /fixing, testing and commissioning of following nominal size of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass pipe section insulation covered with a layer of 120gm/sqm polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS: 1322 as amended up to date) at joints and repairing of damage to building etc. as per specifications and as required.Note: The Pipes of sizes 150 mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589,from minimum 6.35 mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 25mm dia. (50mm thick fiber glass insulation) |
| 7 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 8 | OD148684/2026-2027:Supply, fabrication, Installation and testing of flexible connections constructed flexible double canvas sleeve in accordance with approved shop drawings and as per the specifications for each FCU unit. |
| 9 | 90.6.5.2:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 0.75 sq mm |
| 10 | OD148835/2026-2027:Dismantling G.I. pipes ( external work & internal work ) including excavation and refilling holes after taking out the pipes, manually / by mechanical means (Including Gas cutting machines, )including stacking of pipes within 50 metres lead as per direction of Engineer- in- Charges. |
| 11 | OD224597/2025-2026:Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrile rubber insulation - 19 mm |
| 12 | 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 13 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 14 | 18.11.5:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 15 | OD149003/2026-2027:Supply, installation, testing & commissioning of 25 mm UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line. The system shall be complete in all respects for commissioning. |
| 16 | OD149004/2026-2027:Supply, installation, testing & commissioning of 32 mm UPVC Class E condensate drain pipe with U trap, insulation & fittings up to drain line. The system shall be complete in all respects for commissioning. |
| 17 | OD157882/2026-2027:Charges for dismantling the existing EI, complete, making good the damages of walls and conveying the dismantled materials to section store. |
| 18 | 1.35:Installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 19 | civil |
| 20 | 18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender