Tender For Rehabiltation And Rennovation Of Padipparambil Wss,Kattyanpara Wss,Kandappikkunnu Ws,Parappuram Sc Unnathy Water Supply Scheme In Pookottur Gp In Malappuram District Under Sustainability Support Project 2026-27
Tender Overview
Project Description
Tender for Rehabiltation And Rennovation Of Padipparambil Wss,Kattyanpara Wss,Kandappikkunnu Ws,Parappuram Sc Unnathy Water Supply Scheme In Pookottur Gp In Malappuram District Under Sustainability Support Project 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | APPENDIX A : PADIPPARAMBIL WSS |
| 2 | HOUSE CONNECTION &PIPELINE WORKS: Providing and fixing G.I. pipes(Medium) complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore |
| 3 | :Providing and fixing G.I. pipes(Medium) complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore |
| 4 | :Providing and fixing G.I. pipes(Medium) complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore |
| 5 | :Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 6 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock. |
| 7 | Supply of PVC Pipe, 10kg/cm2, 63mm Dia. |
| 8 | Supply of PVC Pipe, 10kg/cm2, 75mm Dia. |
| 9 | Supply of PVC Pipe, 10kg/cm2, 90mm Dia. |
| 10 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes. |
| 11 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes. |
| 12 | :Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes. |
| 13 | Supplying and laying uPVC pipe specials for 63 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 14 | Supplying and laying uPVC pipe specials for 75 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 15 | Supplying and laying uPVC pipe specials for 90 mm dia uPVC pipe with class 10kg/cm2 or higher @ 3% rate of cost of pipes |
| 16 | Providing 15mm water meter from existing PVC / HDPE line, using 20mm Indian Standard Class 6 uPVC pipe and Ball Valve, uPVC, 12.5kg/cm2, 20mm ,PVC Air valve, Elbow, MTA,FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. |
| 17 | Engaging Coolie. |
| 18 | :Engaging Fitter ( grade 1). |
| 19 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 20 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore |
| 21 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 22 | Supplying Providing Protection Tube of 160mm PVC pipe 10 kg - 1.20m long each, including taking necessary earth work of trench size 60cmx 60cmx 1.15m, cost of 160mm PVC end cap 10kg- ] no. |
| 23 | Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 24 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 25 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 26 | Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of consumables, hire for tools and labour charges etc., complete but excluding cost of materials and as per the directions of the department officers. |
| 27 | Providing additional length of house connection pipe using 20mm (1/2 inch) PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PN16 specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads, and excluding cost of materials etc., and as per the directions of the department officers. |
| 28 | INSTALLATION OF PUMP SET::-Pump & Motor : Supply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, conforming to IS 8034/2002 and amended thereafter and BEE3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl / Diffuser with ISI mark. The pump shall be directly coupled to a continuous rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283,/ 1995 as amended thereafter, suitable for operation in AC 3 phase 415 V + /- 10%, 50 Hz + / - 5%, Duty Conditions :Discharge - 2.96 lpsTotal Head 100 m HP:- b. Starter:Fully automatic air break star delta starter with single phase preventor with ammeter confirming to IS 13947, iec 60947-1 with auto restart facility for pump houses where panel boards are available, Supply and delivery of Star-Delta starter where panel boards are available confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 Nos., CT operated Ammeter(65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature Circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm / 4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor. as per IE rules and code of practice, for working 10 HP Submersible pump set, considering all practical losses in Voltage and efficiency.c. Panel board:Supply, erection, testing and commissioning of one number cubical type floor mounted MS fabricated dust and vermin proof common control panel board , suitable for providing control system for running pump sets, suitable capacity MCCBs , providing suitable size Aluminum bus bar , provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation, for working 10 HP Submersible pump set. d. Cabling work:Supply, laying, testing and commissioning of 185 sqmm x 3.50 core XLPE cables for the above pump set from panel board to starter and Copper Cable not below 25 sqmm , 6 lines, from starter to motor, for working 10 HP Submersible pump set. considering energy conservation, including providing necessary Cable Tray of MS fabrication in side the building and sand filled brick trench, additional length allowance as loop for future repair as per the direction of Engineer.e. Earthing:Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.f. Capacitor:Supply, erection, testing and commissioning of heavy duty APF capacitor 4 KVAr for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834g. Valves:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm dia. 1.60 PN pressure rating. Fitting of valves shall include proper RCC support , for Non return valves and Sluice Valves , of reputed make.h. Suction and delivery pipe connections:Supply and fitting of 50mm dia. best quality C class GI erection pipe, for a total length of 10 m. suitable for the above pump set with suitable flanges, bends, nut and bolts IR sheet packing etc. complete (erection pipe should be of 2m each with flanged joints, welded firmly inside and out side for the flange, to hold the heavy load, and for facilitating lifting and erection of motor inside the pump house) and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.i. General Conditions:Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and accessories supplied. Additional length of Erection pipe and Electric cable beyond 10m length will be paid additionally. |
| 29 | Maintanance work for Pumphouse and Tank:- Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 30 | Lettering with black Japan pint of approved brand and manufacture |
| 31 | White washing with lime to give an even shade :Old work (one or more coats) |
| 32 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 33 | Water Quality Test:Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters. |
| 34 | APPENDIX B : KATTYANPARA WSS |
| 35 | Maintanance works on GLSR:Washing OHSR/GLSR using brooms, brushes and bleaching powder by engaging coolies, scrubbing twice, washing and cleaning using fresh water, including side wall, floor slab and columns, disposing the the slurry / waste materials away from the immediate premises and within the initial lead of 50m from the periphery of the tank, without causing any damage to the existing structure and installations, charges including the operation of valves, conveyance and hire charges of tools and as per the direction of the department officers etc. complete. |
| 36 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 37 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 38 | Lettering with black Japan pint of approved brand and manufacture |
| 39 | Pipeline works:Providing and fixing G.I. pipes(Medium) complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore |
| 40 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 41 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock. |
| 42 | Supply of PVC Pipe, 10kg/cm2, 75mm Dia. |
| 43 | Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes. |
| 44 | Supplying and laying upvc pipe specials for 75mm dia uPVC pipe with class 10kg/cm2 or higher@ 3% rate of cost of pipes |
| 45 | Engaging Coolie. |
| 46 | :Engaging Fitter ( grade 1). |
| 47 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore |
| 48 | Repair work within 1 m length in 20 mm (3/4 inch) house connections, using 25mm Indian Standard Class 6 uPVC pipe and specials, including trenching and refilling in all kinds of soil, hire for tools, cost of consumables and labour charges, cost of materials, including charges for lighting, watching, providing caution boards, traffic control etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads and as per the directions of the department officers. |
| 49 | Rectification of leakages of 65mm G.I. Pipes in exposed portions by replacing lengths up to 1.0m by cutting, removing and stacking the damaged portion from the existing line without causing any damages to the remaining portion and specials and conveying and replacing with G.I. Pipes of suitable size and jointing by thraded coupler and union of suitable size including threading, alignement, laying and jointing to make a water tight joint, testing the line to the required pressure, rectifying any defects noticed, without causing any damages to any other utilities, including the charges hire and conveyance of tools, plant and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion, necessary scaffolding including the cost of specials but excluding cost of pipe and as per the direction of departmental officers etc., complete. |
| 50 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3graded stone aggregate 20 mm nominal size derived from natural sources) |
| 51 | Water Quality Test:Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters. |
| 52 | APPENDIX C : KANDAPPIKKUNNU WSS |
| 53 | MAINTANANCE WORKS ON GLSR:Washing OHSR/GLSR using brooms, brushes and bleaching powder by engaging coolies, scrubbing twice, washing and cleaning using fresh water, including side wall, floor slab and columns, disposing the the slurry / waste materials away from the immediate premises and within the initial lead of 50m from the periphery of the tank, without causing any damage to the existing structure and installations, charges including the operation of valves, conveyance and hire charges of tools and as per the direction of the department officers etc. complete. |
| 54 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 55 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 56 | Lettering with black Japan pint of approved brand and manufacture |
| 57 | Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 58 | Engaging Coolie. |
| 59 | Engaging Fitter ( grade 1). |
| 60 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 61 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 62 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 63 | Lettering with black Japan pint of approved brand and manufacture |
| 64 | PUMPSET INSTALLATION &MOBILE STARTER:a. Pump & Motor : Supply, erection, testing and commissioning of KWA pre-qualified reputed make open well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl / Diffuser with ISI mark. The pump shall be directly coupled to a continuous rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283,/ 1995 as amended thereafter, suitable for operation in AC 3 phase 415 V + /- 10%, 50 Hz + / - 5%, Duty Conditions :Discharge - 1.98Total Head :- 113 m HPb. Starter:Fully automatic air break star delta starter with single phase preventer with ammeter confirming to IS 13947, iec 60947-1 with auto restart facility for pump houses where panel boards are available, Supply and delivery of Star-Delta starter where panel boards are available confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 Nos., CT operated Ammeter(65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature Circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventer, dry running preventer and On/Off Push button switches, wiring with 1 sq.mm / 4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor. as per IE rules and code of practice, for working 10 HP Submersible pump set, considering all practical losses in Voltage and efficiency.c. Panel board:Supply, erection, testing and commissioning of one number cubical type floor mounted MS fabricated dust and vermin proof common control panel board , suitable for providing control system for running pump sets, suitable capacity MCCBs , providing suitable size Aluminium bus bar , provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation, for working 10 HP Submersible pump set. d. Cabling work:Supply, laying, testing and commissioning of 185 sqmm x 3.50 core XLPE cables for the above pump set from panel board to starter and Copper Cable not below 25 sqmm , 6 lines, from starter to motor, for working 10 HP Submersible pump set. considering energy conservation, including providing necessary Cable Tray of MS fabrication in side the building and sand filled brick trench, additional length allowance as loop for future repair as per the direction of Engineer.e. Earthing:Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.f. Capacitor:Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834g. Valves:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm dia. 1.60 PN pressure rating. Fitting of valves shall include proper RCC support , for Non return valves and Sluice Valves , of reputed make.h. Suction and delivery pipe connections:Supply and fitting of 50mm dia. best quality C class GI erection pipe, for a total length of 10 m. suitable for the above pump set with suitable flanges, bends, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 2m each with flanged joints, welded firmly inside and out side for the flange, to hold the heavy load, and for facilitating lifting and erection of motor inside the pump house) and connecting the delivery side ofthe pump with the valves and suitable specials to connect with the pumping main.i. General Conditions:Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied. |
| 65 | Mobile starter with all required fittings and features like: -Motor ON/OFF through missed call -Motor ON/OFF through SMS -Inbuild preventer and auto starter -Suitable every single/three phase motor starter -Inbuilt star delta timer -Dry run prevention -Overload prevention -Realtime clock(RTC) -One year guarantee and ensured customer service at site when ever required |
| 66 | Water Quality Test:-Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters. |
| 67 | APPENDIX D : PARAPPURAM SC UNNATHY WSS |
| 68 | Maintanance works on GLSR:-12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 69 | :Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 70 | :Lettering with black Japan pint of approved brand and manufacture |
| 71 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 72 | Maintanance works on Source:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 73 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 74 | . Pump & Motor : Supply, erection, testing and commissioning of KWA pre-qualified reputed make Bore well submersible motor pump set, coforming to IS 8034/2002 and amended thereafter and BEE3 Star of rated discharge, and Head, with Bronze or Cast SS impeller, Brass Screws and CI FG 200 grade Pump Bowl / Diffuser with ISI mark. The pump shall be directly coupled to a continuous rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283,/ 1995 as amended thereafter, suitable for operation in AC 3 phase 415 V + /- 10%, 50 Hz + / - 5%, Duty Conditions :Discharge - 0.96Total Head -134 m HP:- b. Starter:Fully automatic air break star delta starter with single phase preventer with ammeter confirming to IS 13947, iec 60947-1 with auto restart facility for pump houses where panel boards are available, Supply and delivery of Star-Delta starter where panel boards are available confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 Nos., CT operated Ammeter(65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature Circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventer, dry running preventer and On/Off Push button switches, wiring with 1 sq.mm / 4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor. as per IE rules and code of practice, for working 10 HP Submersible pump set, considering all practical losses in Voltage and efficiency.c. Panel board:Supply, erection, testing and commissioning of one number cubical type floor mounted MS fabricated dust and vermin proof common control panel board , suitable for providing control system for running pump sets, suitable capacity MCCBs , providing suitable size Aluminium bus bar , provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation, for working 10 HP Submersible pump set. d. Cabling work:Supply, laying, testing and commissioning of 185 sqmm x 3.50 core XLPE cables for the above pump set from panel board to starter and Copper Cable not below 25 sqmm , 6 lines, from starter to motor, for working 10 HP Submersible pump set. considering energy conservation, including providing necessary Cable Tray of MS fabrication in side the building and sand filled brick trench, additional length allowance as loop for future repair as per the direction of Engineer.e. Earthing:Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing Gl/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.f. Capacitor:Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834g. Valves:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non retum valve of 50 mm dia. 1.60 PN pressure rating. Fitting of valves shall include proper RCC support , for Non return valves and Sluice Valves , of reputed make.h. Suction and delivery pipe connections:Supply and fitting of 50mm dia. best quality C class GI erection pipe, for a total length of 10 m. suitable for the above pump set with suitable flanges, bends, nut and bolts IR sheet packing etc. complete (erection pipe shuould be of 2m each with flanged joints, welded firmly inside and out side for the flange, to hold the heavy load, and for facilitating lifting and erection of motor inside the pump house) and connecting the delivery side ofthe pump with the valves and suitable specials to connect with the pumping main.i. General Conditions:Warranty - 2 years (rate inclusive of 2 year warranty and maintenance during a period of 2 years from the date of commissioning), for Motor pump set and acessories supplied. |
| 75 | Mobile starter with all required fittings and features like: -Motor ON/OFF through missed call -Motor ON/OFF through SMS -Inbuild preventer and auto starter -Suitable every single/three phase motor starter -Inbuilt star delta timer -Dry run prevention -Overload prevention -Real time clock(RTC) -One year guarantee and ensured customer service at site when ever required |
| 76 | Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes. 4 sq.mm. |
| 77 | Supply and Fixingof Column Pipe 50 mm nomianl Dia Coupler end 20kg/cm2 standard class red strip colour |
| 78 | House connection &Pipeline works:-Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 79 | :Providing 15mm water meter from existing PVC / HDPE line, using 20mm Indian Standard Class 6 uPVC pipe and Ball Valve, uPVC, 12.5kg/cm2, 20mm ,PVC Air valve, Elbow, MTA,FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. |
| 80 | :Engaging Coolie. |
| 81 | Engaging Fitter ( grade 1). |
| 82 | :Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 83 | :Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 84 | Repair work within 1 m length in 20 mm (3/4 inch) house connections, using 25mm Indian Standard Class 6 uPVC pipe and specials, including trenching and refilling in all kinds of soil, hire for tools, cost of consumables and labour charges, cost of materials, including charges for lighting, watching, providing caution boards, traffic control etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads and as per the directions of the department officers. |
| 85 | :providing and fixing stand post in house connections using 63mm dia 6Kg/cm2 uPVC pipe of height 1m (+30 cm below under ground fixed in CC 1:2:4 using 20mm aggregate) with end cap. |
| 86 | Water Quality Test:-Testing water sample from the source of scheme at any Government laboratory and submitting the report- both physical and bacteriological parameters. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender