Tender for Procurement Of Civil Works For New Micro Flood Shelters At Different Locations Of Assam Under Assam Integrated River Bank Management Project (Airbmp)
BOQ
| Sl. No. | Item Description |
| 1 | BARNAGAR |
| 2 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 4 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 5 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 6 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 7 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 10 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (per bag of cement of 50 kg) |
| 11 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 12 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 13 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 17 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 18 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 19 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 20 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 21 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 22 | PUF Roof Panel, Thickness: 60 mm |
| 23 | Deck Sheet of 1mm gavanised sheet |
| 24 | STUD Connector 19MM DIA 100MM LONG |
| 25 | Door with Frame |
| 26 | Aluminium Grill |
| 27 | Ventilator |
| 28 | Accessories ( U channel+ L Channel+ Covering) |
| 29 | Galvanised Ridge Cover |
| 30 | PPGI/PPGL Sheet of 0.50mm thickness |
| 31 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 32 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 33 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 34 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 35 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 36 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 37 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 38 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 39 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 40 | Melamine polishing on wood work (one or more coat). |
| 41 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 42 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 43 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 44 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 45 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 46 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 47 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 48 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 49 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 50 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 51 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 52 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 53 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 54 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 55 | 25 mm nominal dia Pipes |
| 56 | 32 mm nominal dia Pipes |
| 57 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 58 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 59 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 60 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 61 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 62 | 20mm nominal bore |
| 63 | 32mm nominal bore |
| 64 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 65 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 66 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 67 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 68 | (iii) 75mm dia. |
| 69 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 70 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 71 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 72 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 73 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 74 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 75 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 76 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 77 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 78 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 79 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 80 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 81 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 82 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 83 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 84 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 85 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 86 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 87 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 88 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 89 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 90 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 91 | 15/16 A switch |
| 92 | 3 pin 5/6 A socket outlet |
| 93 | 6 pin 15/16 A socket outlet |
| 94 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 95 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 96 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 97 | 6 Module (200mmX75mm) |
| 98 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 99 | 6 Module |
| 100 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 101 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 102 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 103 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 104 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 105 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 106 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 107 | Double pole |
| 108 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 109 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 110 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 111 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 112 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 113 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 114 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 115 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 116 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 117 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 118 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 119 | 18W LED Tube Light |
| 120 | LED Bulb with holder/ceiling light |
| 121 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 122 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 123 | 3-Phase New Power Supply Connection Charges |
| 124 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 125 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 126 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 127 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 128 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 129 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 130 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 131 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 132 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 133 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 134 | ESMP (Exact Amount to be quoted as per Bid |
| 135 | GOLAGHAT |
| 136 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 137 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 138 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 139 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 140 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 141 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 142 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 143 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 144 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (per bag of cement of 50 kg) |
| 145 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 146 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 147 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 148 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 149 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 150 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 151 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 152 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 153 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 154 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 155 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 156 | PUF Roof Panel, Thickness: 60 mm |
| 157 | Deck Sheet of 1mm gavanised sheet |
| 158 | STUD Connector 19MM DIA 100MM LONG |
| 159 | Door with Frame |
| 160 | Aluminium Grill |
| 161 | Ventilator |
| 162 | Accessories ( U channel+ L Channel+ Covering) |
| 163 | Galvanised Ridge Cover |
| 164 | PPGI/PPGL Sheet of 0.50mm thickness |
| 165 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 166 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 167 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 168 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 169 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 170 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 171 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 172 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 173 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 174 | Melamine polishing on wood work (one or more coat). |
| 175 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 176 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 177 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 178 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 179 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 180 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 181 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 182 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 183 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 184 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 185 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 186 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 187 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 188 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 189 | 25 mm nominal dia Pipes |
| 190 | 32 mm nominal dia Pipes |
| 191 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 192 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 193 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 194 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 195 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 196 | 20mm nominal bore |
| 197 | 32mm nominal bore |
| 198 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 199 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 200 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 201 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 202 | (iii) 75mm dia. |
| 203 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 204 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 205 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 206 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 207 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 208 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 209 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 210 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 211 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 212 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 213 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 214 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 215 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 216 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 217 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 218 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 219 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 220 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 221 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 222 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 223 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 224 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 225 | 15/16 A switch |
| 226 | 3 pin 5/6 A socket outlet |
| 227 | 6 pin 15/16 A socket outlet |
| 228 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 229 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 230 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 231 | 6 Module (200mmX75mm) |
| 232 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 233 | 6 Module |
| 234 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 235 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 236 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 237 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 238 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 239 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 240 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 241 | Double pole |
| 242 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 243 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 244 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 245 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 246 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 247 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 248 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 249 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 250 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 251 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 252 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 253 | 18W LED Tube Light |
| 254 | LED Bulb with holder/ceiling light |
| 255 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 256 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 257 | 3-Phase New Power Supply Connection Charges |
| 258 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 259 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 260 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 261 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 262 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 263 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 264 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 265 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 266 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 267 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 268 | ESMP (Exact Amount to be quoted as per Bid |
| 269 | UJONI MAJULI |
| 270 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 271 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 272 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 273 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 274 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 275 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 276 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 277 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 278 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (per bag of cement of 50 kg) |
| 279 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 280 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 281 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 282 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 283 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 284 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 285 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 286 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 287 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 288 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 289 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 290 | PUF Roof Panel, Thickness: 60 mm |
| 291 | Deck Sheet of 1mm gavanised sheet |
| 292 | STUD Connector 19MM DIA 100MM LONG |
| 293 | Door with Frame |
| 294 | Aluminium Grill |
| 295 | Ventilator |
| 296 | Accessories ( U channel+ L Channel+ Covering) |
| 297 | Galvanised Ridge Cover |
| 298 | PPGI/PPGL Sheet of 0.50mm thickness |
| 299 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 300 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 301 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 302 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 303 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 304 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 305 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 306 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 307 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 308 | Melamine polishing on wood work (one or more coat). |
| 309 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 310 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 311 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 312 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 313 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 314 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 315 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 316 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 317 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 318 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 319 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 320 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 321 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 322 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 323 | 25 mm nominal dia Pipes |
| 324 | 32 mm nominal dia Pipes |
| 325 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 326 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 327 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 328 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 329 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 330 | 20mm nominal bore |
| 331 | 32mm nominal bore |
| 332 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 333 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 334 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 335 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 336 | (iii) 75mm dia. |
| 337 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 338 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 339 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 340 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 341 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 342 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 343 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 344 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 345 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 346 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 347 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 348 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 349 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 350 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 351 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 352 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 353 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 354 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 355 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 356 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 357 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 358 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 359 | 15/16 A switch |
| 360 | 3 pin 5/6 A socket outlet |
| 361 | 6 pin 15/16 A socket outlet |
| 362 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 363 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 364 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 365 | 6 Module (200mmX75mm) |
| 366 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 367 | 6 Module |
| 368 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 369 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 370 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 371 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 372 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 373 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 374 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 375 | Double pole |
| 376 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 377 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 378 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 379 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 380 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 381 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 382 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 383 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 384 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 385 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 386 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 387 | 18W LED Tube Light |
| 388 | LED Bulb with holder/ceiling light |
| 389 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 390 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 391 | 3-Phase New Power Supply Connection Charges |
| 392 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 393 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 394 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 395 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 396 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 397 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 398 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 399 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 400 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 401 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 402 | ESMP (Exact Amount to be quoted as per Bid |
| 403 | DHAKUAKHANA |
| 404 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 405 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 406 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 407 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 408 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 409 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 410 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 411 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 412 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 413 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 414 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 415 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 416 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 417 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 418 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 419 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 420 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 421 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 422 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 423 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 424 | PUF Roof Panel, Thickness: 60 mm |
| 425 | Deck Sheet of 1mm gavanised sheet |
| 426 | STUD Connector 19MM DIA 100MM LONG |
| 427 | Door with Frame |
| 428 | Aluminium Grill |
| 429 | Ventilator |
| 430 | Accessories ( U channel+ L Channel+ Covering) |
| 431 | Galvanised Ridge Cover |
| 432 | PPGI/PPGL Sheet of 0.50mm thickness |
| 433 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 434 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 435 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 436 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 437 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 438 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 439 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 440 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 441 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 442 | Melamine polishing on wood work (one or more coat). |
| 443 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 444 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 445 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 446 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 447 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 448 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 449 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 450 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 451 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 452 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 453 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 454 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 455 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 456 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 457 | 25 mm nominal dia Pipes |
| 458 | 32 mm nominal dia Pipes |
| 459 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 460 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 461 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 462 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 463 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 464 | 20mm nominal bore |
| 465 | 32mm nominal bore |
| 466 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 467 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 468 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 469 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 470 | (iii) 75mm dia. |
| 471 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 472 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 473 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 474 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 475 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 476 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 477 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 478 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 479 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 480 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 481 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 482 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 483 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 484 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 485 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 486 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 487 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 488 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 489 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 490 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 491 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 492 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 493 | 15/16 A switch |
| 494 | 3 pin 5/6 A socket outlet |
| 495 | 6 pin 15/16 A socket outlet |
| 496 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 497 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 498 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 499 | 6 Module (200mmX75mm) |
| 500 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 501 | 6 Module |
| 502 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 503 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 504 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 505 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 506 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 507 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 508 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 509 | Double pole |
| 510 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 511 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 512 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 513 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 514 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 515 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 516 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 517 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 518 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 519 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 520 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 521 | 18W LED Tube Light |
| 522 | LED Bulb with holder/ceiling light |
| 523 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 524 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 525 | 3-Phase New Power Supply Connection Charges |
| 526 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 527 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 528 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 529 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 530 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 531 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 532 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 533 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 534 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 535 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 536 | ESMP (Exact Amount to be quoted as per Bid |
| 537 | NOWBOICHA |
| 538 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 539 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 540 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 541 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 542 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 543 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 544 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 545 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 546 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 547 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 548 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 549 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 550 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 551 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 552 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 553 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 554 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 555 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 556 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 557 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 558 | PUF Roof Panel, Thickness: 60 mm |
| 559 | Deck Sheet of 1mm gavanised sheet |
| 560 | STUD Connector 19MM DIA 100MM LONG |
| 561 | Door with Frame |
| 562 | Aluminium Grill |
| 563 | Ventilator |
| 564 | Accessories ( U channel+ L Channel+ Covering) |
| 565 | Galvanised Ridge Cover |
| 566 | PPGI/PPGL Sheet of 0.50mm thickness |
| 567 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 568 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 569 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 570 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 571 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 572 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 573 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 574 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 575 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 576 | Melamine polishing on wood work (one or more coat). |
| 577 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 578 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 579 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 580 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 581 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 582 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 583 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 584 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 585 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 586 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 587 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 588 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 589 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 590 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 591 | 25 mm nominal dia Pipes |
| 592 | 32 mm nominal dia Pipes |
| 593 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 594 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 595 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 596 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 597 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 598 | 20mm nominal bore |
| 599 | 32mm nominal bore |
| 600 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 601 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 602 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 603 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 604 | (iii) 75mm dia. |
| 605 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 606 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 607 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 608 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 609 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 610 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 611 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 612 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 613 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 614 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 615 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 616 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 617 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 618 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 619 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 620 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 621 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 622 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 623 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 624 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 625 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 626 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 627 | 15/16 A switch |
| 628 | 3 pin 5/6 A socket outlet |
| 629 | 6 pin 15/16 A socket outlet |
| 630 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 631 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 632 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 633 | 6 Module (200mmX75mm) |
| 634 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 635 | 6 Module |
| 636 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 637 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 638 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 639 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 640 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 641 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 642 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 643 | Double pole |
| 644 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 645 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 646 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 647 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 648 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 649 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 650 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 651 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 652 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 653 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 654 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 655 | 18W LED Tube Light |
| 656 | LED Bulb with holder/ceiling light |
| 657 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 658 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 659 | 3-Phase New Power Supply Connection Charges |
| 660 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 661 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 662 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 663 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 664 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 665 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 666 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 667 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 668 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 669 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 670 | ESMP (Exact Amount to be quoted as per Bid |
| 671 | NAZIRA |
| 672 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 673 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 674 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 675 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 676 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 677 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 678 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 679 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 680 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 681 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 682 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 683 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 684 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 685 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 686 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 687 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 688 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 689 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 690 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 691 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 692 | PUF Roof Panel, Thickness: 60 mm |
| 693 | Deck Sheet of 1mm gavanised sheet |
| 694 | STUD Connector 19MM DIA 100MM LONG |
| 695 | Door with Frame |
| 696 | Aluminium Grill |
| 697 | Ventilator |
| 698 | Accessories ( U channel+ L Channel+ Covering) |
| 699 | Galvanised Ridge Cover |
| 700 | PPGI/PPGL Sheet of 0.50mm thickness |
| 701 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 702 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 703 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 704 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 705 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 706 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 707 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 708 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 709 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 710 | Melamine polishing on wood work (one or more coat). |
| 711 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 712 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 713 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 714 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 715 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 716 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 717 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 718 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 719 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 720 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 721 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 722 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 723 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 724 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 725 | 25 mm nominal dia Pipes |
| 726 | 32 mm nominal dia Pipes |
| 727 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 728 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 729 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 730 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 731 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 732 | 20mm nominal bore |
| 733 | 32mm nominal bore |
| 734 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 735 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 736 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 737 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 738 | (iii) 75mm dia. |
| 739 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 740 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 741 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 742 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 743 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 744 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 745 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 746 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 747 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 748 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 749 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 750 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 751 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 752 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 753 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 754 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 755 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 756 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 757 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 758 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 759 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 760 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 761 | 15/16 A switch |
| 762 | 3 pin 5/6 A socket outlet |
| 763 | 6 pin 15/16 A socket outlet |
| 764 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 765 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 766 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 767 | 6 Module (200mmX75mm) |
| 768 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 769 | 6 Module |
| 770 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 771 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 772 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 773 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 774 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 775 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 776 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 777 | Double pole |
| 778 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 779 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 780 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 781 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 782 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 783 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 784 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 785 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 786 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 787 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 788 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 789 | 18W LED Tube Light |
| 790 | LED Bulb with holder/ceiling light |
| 791 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 792 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 793 | 3-Phase New Power Supply Connection Charges |
| 794 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 795 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 796 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 797 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 798 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 799 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 800 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 801 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 802 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 803 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 804 | ESMP (Exact Amount to be quoted as per Bid |
| 805 | SIVASAGAR |
| 806 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 807 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 808 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 809 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 810 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 811 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 812 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 813 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 814 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 815 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 816 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 817 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 818 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 819 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 820 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 821 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 822 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 823 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 824 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 825 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 826 | PUF Roof Panel, Thickness: 60 mm |
| 827 | Deck Sheet of 1mm gavanised sheet |
| 828 | STUD Connector 19MM DIA 100MM LONG |
| 829 | Door with Frame |
| 830 | Aluminium Grill |
| 831 | Ventilator |
| 832 | Accessories ( U channel+ L Channel+ Covering) |
| 833 | Galvanised Ridge Cover |
| 834 | PPGI/PPGL Sheet of 0.50mm thickness |
| 835 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 836 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 837 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 838 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 839 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 840 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 841 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 842 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 843 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 844 | Melamine polishing on wood work (one or more coat). |
| 845 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 846 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 847 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 848 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 849 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 850 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 851 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 852 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 853 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 854 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 855 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 856 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 857 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 858 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 859 | 25 mm nominal dia Pipes |
| 860 | 32 mm nominal dia Pipes |
| 861 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 862 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 863 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 864 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 865 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 866 | 20mm nominal bore |
| 867 | 32mm nominal bore |
| 868 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 869 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 870 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 871 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 872 | (iii) 75mm dia. |
| 873 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 874 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 875 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 876 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 877 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 878 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 879 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 880 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 881 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 882 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 883 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 884 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 885 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 886 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 887 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 888 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 889 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 890 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 891 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 892 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 893 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 894 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 895 | 15/16 A switch |
| 896 | 3 pin 5/6 A socket outlet |
| 897 | 6 pin 15/16 A socket outlet |
| 898 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 899 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 900 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 901 | 6 Module (200mmX75mm) |
| 902 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 903 | 6 Module |
| 904 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 905 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 906 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 907 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 908 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 909 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 910 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 911 | Double pole |
| 912 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 913 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 914 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 915 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 916 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 917 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 918 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 919 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 920 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 921 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 922 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 923 | 18W LED Tube Light |
| 924 | LED Bulb with holder/ceiling light |
| 925 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 926 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 927 | 3-Phase New Power Supply Connection Charges |
| 928 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 929 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 930 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 931 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 932 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 933 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 934 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 935 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 936 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 937 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 938 | ESMP (Exact Amount to be quoted as per Bid |
| 939 | KATIGORAH |
| 940 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 941 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 942 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 943 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 944 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 945 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 946 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 947 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 948 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 949 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 950 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 951 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 952 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 953 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 954 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 955 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 956 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 957 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 958 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 959 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 960 | PUF Roof Panel, Thickness: 60 mm |
| 961 | Deck Sheet of 1mm gavanised sheet |
| 962 | STUD Connector 19MM DIA 100MM LONG |
| 963 | Door with Frame |
| 964 | Aluminium Grill |
| 965 | Ventilator |
| 966 | Accessories ( U channel+ L Channel+ Covering) |
| 967 | Galvanised Ridge Cover |
| 968 | PPGI/PPGL Sheet of 0.50mm thickness |
| 969 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 970 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 971 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 972 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 973 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 974 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 975 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 976 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 977 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 978 | Melamine polishing on wood work (one or more coat). |
| 979 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 980 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 981 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 982 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 983 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 984 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 985 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 986 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 987 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 988 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 989 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 990 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 991 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 992 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 993 | 25 mm nominal dia Pipes |
| 994 | 32 mm nominal dia Pipes |
| 995 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 996 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 997 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 998 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 999 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 1000 | 20mm nominal bore |
| 1001 | 32mm nominal bore |
| 1002 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 1003 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 1004 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 1005 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 1006 | (iii) 75mm dia. |
| 1007 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 1008 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 1009 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 1010 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 1011 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 1012 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 1013 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 1014 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 1015 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 1016 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 1017 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 1018 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 1019 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 1020 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 1021 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 1022 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 1023 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 1024 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1025 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1026 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1027 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 1028 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 1029 | 15/16 A switch |
| 1030 | 3 pin 5/6 A socket outlet |
| 1031 | 6 pin 15/16 A socket outlet |
| 1032 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 1033 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1034 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 1035 | 6 Module (200mmX75mm) |
| 1036 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 1037 | 6 Module |
| 1038 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1039 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 1040 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 1041 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 1042 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 1043 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 1044 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 1045 | Double pole |
| 1046 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 1047 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 1048 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 1049 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 1050 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 1051 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 1052 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 1053 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 1054 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 1055 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 1056 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 1057 | 18W LED Tube Light |
| 1058 | LED Bulb with holder/ceiling light |
| 1059 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 1060 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 1061 | 3-Phase New Power Supply Connection Charges |
| 1062 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 1063 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 1064 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 1065 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 1066 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 1067 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 1068 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 1069 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 1070 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 1071 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 1072 | ESMP (Exact Amount to be quoted as per Bid |
| 1073 | MAIBONG |
| 1074 | CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 1075 | Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil |
| 1076 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 1077 | Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete. |
| 1078 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 1079 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 1080 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 1081 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate |
| 1082 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 1083 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 1084 | Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete. |
| 1085 | Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1086 | Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1087 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1088 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 1089 | MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand) |
| 1090 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 1091 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1092 | STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 1093 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 1094 | PUF Roof Panel, Thickness: 60 mm |
| 1095 | Deck Sheet of 1mm gavanised sheet |
| 1096 | STUD Connector 19MM DIA 100MM LONG |
| 1097 | Door with Frame |
| 1098 | Aluminium Grill |
| 1099 | Ventilator |
| 1100 | Accessories ( U channel+ L Channel+ Covering) |
| 1101 | Galvanised Ridge Cover |
| 1102 | PPGI/PPGL Sheet of 0.50mm thickness |
| 1103 | FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick. |
| 1104 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 1105 | FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand) |
| 1106 | 6 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand) |
| 1107 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 1108 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 1109 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 1110 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work |
| 1111 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 1112 | Melamine polishing on wood work (one or more coat). |
| 1113 | Boundary wall 1:4 (1 cement: 4 fine sand) |
| 1114 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 1115 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 1116 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 1117 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 1118 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 1119 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 1120 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge |
| 1121 | Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid |
| 1122 | Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests |
| 1123 | Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White |
| 1124 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 1125 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 1126 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes |
| 1127 | 25 mm nominal dia Pipes |
| 1128 | 32 mm nominal dia Pipes |
| 1129 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 1130 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore |
| 1131 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 1132 | providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms |
| 1133 | Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore |
| 1134 | 20mm nominal bore |
| 1135 | 32mm nominal bore |
| 1136 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 1137 | Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore |
| 1138 | Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete. |
| 1139 | PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia. |
| 1140 | (iii) 75mm dia. |
| 1141 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal) |
| 1142 | Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 1143 | Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr |
| 1144 | Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete |
| 1145 | Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr |
| 1146 | Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe |
| 1147 | FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. |
| 1148 | ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849. |
| 1149 | GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required |
| 1150 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head |
| 1151 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia |
| 1152 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia |
| 1153 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 1154 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) |
| 1155 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 1156 | Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093 |
| 1157 | ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 1158 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1159 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1160 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1161 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 1162 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 1163 | 15/16 A switch |
| 1164 | 3 pin 5/6 A socket outlet |
| 1165 | 6 pin 15/16 A socket outlet |
| 1166 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 1167 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 1168 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) |
| 1169 | 6 Module (200mmX75mm) |
| 1170 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 1171 | 6 Module |
| 1172 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1173 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 1174 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 1175 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 1176 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 1177 | MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 1178 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 1179 | Double pole |
| 1180 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 1181 | Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A |
| 1182 | EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 1183 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 1184 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 1185 | LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required |
| 1186 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 1187 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 1188 | LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm |
| 1189 | Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. |
| 1190 | N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light |
| 1191 | 18W LED Tube Light |
| 1192 | LED Bulb with holder/ceiling light |
| 1193 | Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make |
| 1194 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 1195 | 3-Phase New Power Supply Connection Charges |
| 1196 | BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter |
| 1197 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter |
| 1198 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter |
| 1199 | Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 1200 | Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 1201 | Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. |
| 1202 | Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter |
| 1203 | Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter |
| 1204 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge |
| 1205 | Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx) |
| 1206 | ESMP (Exact Amount to be quoted as per Bid Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 29 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender