Environment and Forests Government Departments Closing in 29 days TDR #58209577

Tender For Procurement Of Civil Works For New Micro Flood Shelters At Different Locations Of Assam Under Assam Integrated River Bank Management Project (Airbmp)

Issued by Government Departments · Kamrup Metro, Assam
Tender Value
15.50 Crore
Estimated cost
Bid Submission
25 Nov 2026
29 days left
EMD
31 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Procurement Of Civil Works For New Micro Flood Shelters At Different Locations Of Assam Under Assam Integrated River Bank Management Project (Airbmp)

BOQ

Name of Work:- Procurement of Civil Works for New Micro Flood Shelters at different locations of Assam under Assam Integrated River Bank Management Project (AIRBMP)
Sl. No. Item Description
1BARNAGAR
2CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
3Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
4Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
5Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
6Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
7Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
9Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
10Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (per bag of cement of 50 kg)
11Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
12Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
13Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
14Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
16Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
17MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
18Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
19Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
20STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
21Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
22PUF Roof Panel, Thickness: 60 mm
23Deck Sheet of 1mm gavanised sheet
24STUD Connector 19MM DIA 100MM LONG
25Door with Frame
26Aluminium Grill
27Ventilator
28Accessories ( U channel+ L Channel+ Covering)
29Galvanised Ridge Cover
30PPGI/PPGL Sheet of 0.50mm thickness
31FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
32Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
33FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
346 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
35Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
36Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
37Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
38Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
39Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
40Melamine polishing on wood work (one or more coat).
41Boundary wall 1:4 (1 cement: 4 fine sand)
42Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
43Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
44Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
45Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
46Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
47Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
48Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
49Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
50Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
51Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
52Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
53Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
54Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
5525 mm nominal dia Pipes
5632 mm nominal dia Pipes
57Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
58Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
59Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
60providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
61Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
6220mm nominal bore
6332mm nominal bore
64Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
65Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
66Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
67PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
68(iii) 75mm dia.
69Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
70Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
71Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
72Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
73Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
74Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
75FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
76ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
77GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
78Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
79Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
80Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
81Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
82Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
83Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
84Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
85ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
86Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
872 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
882 X 4 sq. mm + 1 X 4 sq. mm earth wire
89Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
9115/16 A switch
923 pin 5/6 A socket outlet
936 pin 15/16 A socket outlet
94Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
95Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
96Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
976 Module (200mmX75mm)
98Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
996 Module
100Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
101Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
102Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
103Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
104Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
105MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
106Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
107Double pole
108Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
109Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
110EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
111Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
112Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
113LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
114Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
115Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
116LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
117Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
118N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
11918W LED Tube Light
120LED Bulb with holder/ceiling light
121Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
122Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
1233-Phase New Power Supply Connection Charges
124BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
125Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
126Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
127Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
128Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
129Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
130Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
131Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
132Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
133Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
134ESMP (Exact Amount to be quoted as per Bid
135GOLAGHAT
136CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
137Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
138Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
139Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
140Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
141Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
142Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
143Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
144Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (per bag of cement of 50 kg)
145Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
146Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
147Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
148Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
149Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
150Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
151MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
152Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
153Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
154STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
155Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
156PUF Roof Panel, Thickness: 60 mm
157Deck Sheet of 1mm gavanised sheet
158STUD Connector 19MM DIA 100MM LONG
159Door with Frame
160Aluminium Grill
161Ventilator
162Accessories ( U channel+ L Channel+ Covering)
163Galvanised Ridge Cover
164PPGI/PPGL Sheet of 0.50mm thickness
165FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
166Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
167FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
1686 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
169Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
170Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
171Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
172Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
173Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
174Melamine polishing on wood work (one or more coat).
175Boundary wall 1:4 (1 cement: 4 fine sand)
176Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
177Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
178Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
179Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
180Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
181Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
182Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
183Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
184Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
185Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
186Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
187Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
188Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
18925 mm nominal dia Pipes
19032 mm nominal dia Pipes
191Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
192Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
193Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
194providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
195Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
19620mm nominal bore
19732mm nominal bore
198Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
199Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
200Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
201PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
202(iii) 75mm dia.
203Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
204Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
205Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
206Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
207Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
208Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
209FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
210ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
211GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
212Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
213Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
214Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
215Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
216Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
217Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
218Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
219ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
220Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2212 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2222 X 4 sq. mm + 1 X 4 sq. mm earth wire
223Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
224Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
22515/16 A switch
2263 pin 5/6 A socket outlet
2276 pin 15/16 A socket outlet
228Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
229Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
230Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
2316 Module (200mmX75mm)
232Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
2336 Module
234Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
235Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
236Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
237Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
238Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
239MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
240Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
241Double pole
242Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
243Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
244EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
245Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
246Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
247LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
248Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
249Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
250LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
251Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
252N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
25318W LED Tube Light
254LED Bulb with holder/ceiling light
255Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
256Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
2573-Phase New Power Supply Connection Charges
258BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
259Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
260Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
261Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
262Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
263Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
264Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
265Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
266Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
267Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
268ESMP (Exact Amount to be quoted as per Bid
269UJONI MAJULI
270CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
271Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
272Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
273Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
274Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
275Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
276Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
277Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
278Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (per bag of cement of 50 kg)
279Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
280Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
281Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
282Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
283Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
284Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
285MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
286Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
287Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
288STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
289Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
290PUF Roof Panel, Thickness: 60 mm
291Deck Sheet of 1mm gavanised sheet
292STUD Connector 19MM DIA 100MM LONG
293Door with Frame
294Aluminium Grill
295Ventilator
296Accessories ( U channel+ L Channel+ Covering)
297Galvanised Ridge Cover
298PPGI/PPGL Sheet of 0.50mm thickness
299FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
300Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
301FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
3026 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
303Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
304Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
305Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
306Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
307Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
308Melamine polishing on wood work (one or more coat).
309Boundary wall 1:4 (1 cement: 4 fine sand)
310Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
311Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
312Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
313Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
314Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
315Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
316Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
317Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
318Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
319Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
320Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
321Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
322Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
32325 mm nominal dia Pipes
32432 mm nominal dia Pipes
325Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
326Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
327Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
328providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
329Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
33020mm nominal bore
33132mm nominal bore
332Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
333Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
334Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
335PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
336(iii) 75mm dia.
337Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
338Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
339Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
340Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
341Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
342Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
343FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
344ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
345GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
346Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
347Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
348Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
349Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
350Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
351Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
352Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
353ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
354Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3552 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3562 X 4 sq. mm + 1 X 4 sq. mm earth wire
357Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
358Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
35915/16 A switch
3603 pin 5/6 A socket outlet
3616 pin 15/16 A socket outlet
362Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
363Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
364Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
3656 Module (200mmX75mm)
366Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
3676 Module
368Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
369Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
370Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
371Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
372Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
373MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
374Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
375Double pole
376Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
377Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
378EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
379Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
380Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
381LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
382Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
383Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
384LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
385Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
386N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
38718W LED Tube Light
388LED Bulb with holder/ceiling light
389Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
390Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
3913-Phase New Power Supply Connection Charges
392BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
393Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
394Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
395Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
396Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
397Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
398Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
399Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
400Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
401Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
402ESMP (Exact Amount to be quoted as per Bid
403DHAKUAKHANA
404CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
405Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
406Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
407Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
408Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
409Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
410Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
411Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
412Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
413Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
414Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
415Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
416Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
417Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
418Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
419MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
420Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
421Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
422STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
423Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
424PUF Roof Panel, Thickness: 60 mm
425Deck Sheet of 1mm gavanised sheet
426STUD Connector 19MM DIA 100MM LONG
427Door with Frame
428Aluminium Grill
429Ventilator
430Accessories ( U channel+ L Channel+ Covering)
431Galvanised Ridge Cover
432PPGI/PPGL Sheet of 0.50mm thickness
433FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
434Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
435FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
4366 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
437Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
438Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
439Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
440Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
441Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
442Melamine polishing on wood work (one or more coat).
443Boundary wall 1:4 (1 cement: 4 fine sand)
444Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
445Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
446Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
447Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
448Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
449Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
450Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
451Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
452Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
453Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
454Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
455Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
456Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
45725 mm nominal dia Pipes
45832 mm nominal dia Pipes
459Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
460Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
461Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
462providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
463Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
46420mm nominal bore
46532mm nominal bore
466Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
467Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
468Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
469PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
470(iii) 75mm dia.
471Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
472Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
473Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
474Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
475Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
476Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
477FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
478ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
479GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
480Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
481Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
482Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
483Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
484Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
485Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
486Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
487ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
488Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4892 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4902 X 4 sq. mm + 1 X 4 sq. mm earth wire
491Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
492Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
49315/16 A switch
4943 pin 5/6 A socket outlet
4956 pin 15/16 A socket outlet
496Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
497Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
498Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
4996 Module (200mmX75mm)
500Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
5016 Module
502Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
503Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
504Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
505Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
506Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
507MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
508Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
509Double pole
510Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
511Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
512EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
513Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
514Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
515LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
516Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
517Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
518LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
519Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
520N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
52118W LED Tube Light
522LED Bulb with holder/ceiling light
523Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
524Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
5253-Phase New Power Supply Connection Charges
526BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
527Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
528Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
529Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
530Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
531Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
532Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
533Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
534Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
535Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
536ESMP (Exact Amount to be quoted as per Bid
537NOWBOICHA
538CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
539Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
540Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
541Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
542Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
543Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
544Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
545Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
546Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
547Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
548Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
549Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
550Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
551Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
552Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
553MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
554Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
555Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
556STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
557Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
558PUF Roof Panel, Thickness: 60 mm
559Deck Sheet of 1mm gavanised sheet
560STUD Connector 19MM DIA 100MM LONG
561Door with Frame
562Aluminium Grill
563Ventilator
564Accessories ( U channel+ L Channel+ Covering)
565Galvanised Ridge Cover
566PPGI/PPGL Sheet of 0.50mm thickness
567FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
568Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
569FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
5706 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
571Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
572Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
573Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
574Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
575Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
576Melamine polishing on wood work (one or more coat).
577Boundary wall 1:4 (1 cement: 4 fine sand)
578Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
579Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
580Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
581Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
582Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
583Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
584Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
585Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
586Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
587Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
588Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
589Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
590Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
59125 mm nominal dia Pipes
59232 mm nominal dia Pipes
593Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
594Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
595Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
596providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
597Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
59820mm nominal bore
59932mm nominal bore
600Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
601Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
602Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
603PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
604(iii) 75mm dia.
605Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
606Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
607Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
608Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
609Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
610Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
611FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
612ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
613GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
614Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
615Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
616Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
617Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
618Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
619Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
620Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
621ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
622Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
6232 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
6242 X 4 sq. mm + 1 X 4 sq. mm earth wire
625Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
626Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
62715/16 A switch
6283 pin 5/6 A socket outlet
6296 pin 15/16 A socket outlet
630Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
631Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
632Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
6336 Module (200mmX75mm)
634Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
6356 Module
636Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
637Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
638Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
639Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
640Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
641MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
642Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
643Double pole
644Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
645Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
646EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
647Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
648Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
649LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
650Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
651Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
652LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
653Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
654N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
65518W LED Tube Light
656LED Bulb with holder/ceiling light
657Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
658Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
6593-Phase New Power Supply Connection Charges
660BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
661Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
662Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
663Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
664Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
665Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
666Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
667Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
668Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
669Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
670ESMP (Exact Amount to be quoted as per Bid
671NAZIRA
672CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
673Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
674Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
675Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
676Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
677Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
678Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
679Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
680Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
681Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
682Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
683Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
684Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
685Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
686Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
687MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
688Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
689Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
690STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
691Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
692PUF Roof Panel, Thickness: 60 mm
693Deck Sheet of 1mm gavanised sheet
694STUD Connector 19MM DIA 100MM LONG
695Door with Frame
696Aluminium Grill
697Ventilator
698Accessories ( U channel+ L Channel+ Covering)
699Galvanised Ridge Cover
700PPGI/PPGL Sheet of 0.50mm thickness
701FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
702Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
703FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
7046 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
705Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
706Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
707Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
708Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
709Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
710Melamine polishing on wood work (one or more coat).
711Boundary wall 1:4 (1 cement: 4 fine sand)
712Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
713Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
714Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
715Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
716Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
717Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
718Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
719Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
720Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
721Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
722Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
723Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
724Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
72525 mm nominal dia Pipes
72632 mm nominal dia Pipes
727Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
728Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
729Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
730providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
731Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
73220mm nominal bore
73332mm nominal bore
734Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
735Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
736Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
737PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
738(iii) 75mm dia.
739Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
740Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
741Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
742Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
743Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
744Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
745FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
746ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
747GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
748Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
749Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
750Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
751Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
752Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
753Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
754Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
755ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
756Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
7572 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
7582 X 4 sq. mm + 1 X 4 sq. mm earth wire
759Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
760Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
76115/16 A switch
7623 pin 5/6 A socket outlet
7636 pin 15/16 A socket outlet
764Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
765Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
766Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
7676 Module (200mmX75mm)
768Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
7696 Module
770Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
771Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
772Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
773Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
774Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
775MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
776Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
777Double pole
778Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
779Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
780EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
781Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
782Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
783LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
784Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
785Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
786LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
787Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
788N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
78918W LED Tube Light
790LED Bulb with holder/ceiling light
791Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
792Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
7933-Phase New Power Supply Connection Charges
794BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
795Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
796Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
797Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
798Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
799Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
800Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
801Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
802Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
803Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
804ESMP (Exact Amount to be quoted as per Bid
805SIVASAGAR
806CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
807Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
808Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
809Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
810Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
811Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
812Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
813Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
814Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
815Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
816Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
817Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
818Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
819Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
820Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
821MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
822Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
823Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
824STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
825Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
826PUF Roof Panel, Thickness: 60 mm
827Deck Sheet of 1mm gavanised sheet
828STUD Connector 19MM DIA 100MM LONG
829Door with Frame
830Aluminium Grill
831Ventilator
832Accessories ( U channel+ L Channel+ Covering)
833Galvanised Ridge Cover
834PPGI/PPGL Sheet of 0.50mm thickness
835FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
836Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
837FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
8386 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
839Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
840Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
841Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
842Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
843Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
844Melamine polishing on wood work (one or more coat).
845Boundary wall 1:4 (1 cement: 4 fine sand)
846Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
847Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
848Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
849Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
850Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
851Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
852Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
853Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
854Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
855Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
856Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
857Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
858Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
85925 mm nominal dia Pipes
86032 mm nominal dia Pipes
861Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
862Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
863Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
864providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
865Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
86620mm nominal bore
86732mm nominal bore
868Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
869Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
870Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
871PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
872(iii) 75mm dia.
873Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
874Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
875Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
876Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
877Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
878Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
879FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
880ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
881GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
882Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
883Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
884Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
885Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
886Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
887Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
888Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
889ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
890Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
8912 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
8922 X 4 sq. mm + 1 X 4 sq. mm earth wire
893Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
894Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
89515/16 A switch
8963 pin 5/6 A socket outlet
8976 pin 15/16 A socket outlet
898Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
899Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
900Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
9016 Module (200mmX75mm)
902Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
9036 Module
904Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
905Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
906Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
907Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
908Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
909MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
910Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
911Double pole
912Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
913Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
914EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
915Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
916Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
917LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
918Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
919Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
920LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
921Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
922N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
92318W LED Tube Light
924LED Bulb with holder/ceiling light
925Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
926Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
9273-Phase New Power Supply Connection Charges
928BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
929Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
930Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
931Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
932Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
933Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
934Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
935Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
936Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
937Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
938ESMP (Exact Amount to be quoted as per Bid
939KATIGORAH
940CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
941Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
942Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
943Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
944Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
945Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
946Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
947Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
948Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
949Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
950Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
951Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
952Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
953Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
954Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
955MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
956Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
957Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
958STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
959Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
960PUF Roof Panel, Thickness: 60 mm
961Deck Sheet of 1mm gavanised sheet
962STUD Connector 19MM DIA 100MM LONG
963Door with Frame
964Aluminium Grill
965Ventilator
966Accessories ( U channel+ L Channel+ Covering)
967Galvanised Ridge Cover
968PPGI/PPGL Sheet of 0.50mm thickness
969FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
970Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
971FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
9726 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
973Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
974Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
975Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
976Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
977Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
978Melamine polishing on wood work (one or more coat).
979Boundary wall 1:4 (1 cement: 4 fine sand)
980Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
981Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
982Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
983Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
984Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
985Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
986Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
987Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
988Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
989Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
990Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
991Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
992Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
99325 mm nominal dia Pipes
99432 mm nominal dia Pipes
995Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
996Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
997Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
998providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
999Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
100020mm nominal bore
100132mm nominal bore
1002Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
1003Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
1004Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
1005PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
1006(iii) 75mm dia.
1007Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
1008Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
1009Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
1010Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
1011Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
1012Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
1013FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
1014ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
1015GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
1016Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
1017Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
1018Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
1019Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
1020Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
1021Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
1022Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
1023ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1024Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
10252 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
10262 X 4 sq. mm + 1 X 4 sq. mm earth wire
1027Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1028Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
102915/16 A switch
10303 pin 5/6 A socket outlet
10316 pin 15/16 A socket outlet
1032Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1033Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1034Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
10356 Module (200mmX75mm)
1036Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
10376 Module
1038Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
1039Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1040Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
1041Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
1042Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
1043MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
1044Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1045Double pole
1046Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1047Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
1048EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1049Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1050Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1051LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
1052Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
1053Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
1054LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
1055Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
1056N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
105718W LED Tube Light
1058LED Bulb with holder/ceiling light
1059Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
1060Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
10613-Phase New Power Supply Connection Charges
1062BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
1063Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
1064Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
1065Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
1066Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
1067Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
1068Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
1069Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
1070Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
1071Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
1072ESMP (Exact Amount to be quoted as per Bid
1073MAIBONG
1074CONSTRUCTION OF P.E.B MATERIAL BANKExcavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
1075Earth work in excavation over areas (exceeding 30cm In depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed.All kinds of soil
1076Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
1077Supplying and filling in plinth with 100 mm thick Fine sand or stone dust under floors including, watering, ramming consolidating and dressing complete.
1078Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
1079Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
1080Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
1081Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate
1082Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
1083Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
1084Centering and shuttering including strutting, propping, etc. and removal of form for:Foundations, footings, bases of columns for mass concrete.
1085Centering and shuttering including strutting, propping, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers.
1086Centering and shuttering including strutting, propping, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
1087Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
1088Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum
1089MASONRY WORKBrick work with F.P.S. bricks of class designation 7.5 In foundation and plinth inCement mortar 1:4 (1cement: 4 coarse sand)
1090Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
1091Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1092STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
1093Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel membersshall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
1094PUF Roof Panel, Thickness: 60 mm
1095Deck Sheet of 1mm gavanised sheet
1096STUD Connector 19MM DIA 100MM LONG
1097Door with Frame
1098Aluminium Grill
1099Ventilator
1100Accessories ( U channel+ L Channel+ Covering)
1101Galvanised Ridge Cover
1102PPGI/PPGL Sheet of 0.50mm thickness
1103FLOORINGKota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1 : 4 ( 1cement :4 coarse sand):25 mm thick.
1104Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laidon 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including groutingthe joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
1105FINISHING12 mm cement plaster of mix1:4 (1Cement : 4 Coarse sand)
11066 mm cement plaster to ceiling of mix:1:3 (1 Cement : 3 Fine Sand)
1107Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
1108Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
1109Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
1110Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work
1111Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
1112Melamine polishing on wood work (one or more coat).
1113Boundary wall 1:4 (1 cement: 4 fine sand)
1114Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
1115Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
1116Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
1117Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
1118Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
1119Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
1120Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge
1121Plumbing and Sewerage WorksProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
1122Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated typefoot rests
1123Providing and fixing PVC low level flushing cistern with manually control device(Handle lever) confirming to IS-7231,with all fittings and fixtures complete 10 Ltr Capacity White
1124Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
1125Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
1126Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
112725 mm nominal dia Pipes
112832 mm nominal dia Pipes
1129Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
1130Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115mm nominal bore
1131Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
1132providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.32mm nominal bore, weighting not less than 62 grms
1133Providing & Fixing Metal gate valve with CI wheel of Approved Quality(Screwed end):25mm nominal bore
113420mm nominal bore
113532mm nominal bore
1136Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
1137Providing and fixing ball valve (brass) of approved quality , High or low pressure, with plastic floats complete 32 mm nominal bore
1138Supplying & fixing of approved make 15mm CP health faucet with one no, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.
1139PVC PIPES,BENDS,JUNCTIONS,TEES ETC.Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. External Drainagea) In exposed surfaces or in trenches. (i) 110mm dia.
1140(iii) 75mm dia.
1141Supplying, laying, jointing, testing and comissioning of approved make PVC floor trap with C P grating with required concrete encasing all around, complete.a) 110 x 75 mm dia (20 mm water seal)
1142Providing & Fixing in position Domestic Water storage Tank 6x1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
1143Providing and Instaling (Fibre-reinforced plastic) FRP Sewage Tanks having multiple chambers and instalation as per NBC guideleines. Storage Capacity: 500 Ltr
1144Providing and Instaling 500 LPH RO Plant with 304 SS Storage tank with other accessories complete
1145Providing & Fixing in position HDPE wheeled plastic dustbin of capacity 1100 ltr
1146Fire Fighting WorksProviding & Fixing in position Domestic Water storage Tank 4X1500 ltr capacity. 4 Layer Tank of Approved Make, with cover and suitable locking arrangement including 50 mm dia. Pvc pipe
1147FIRE EXTINGUISHERSSupplying, installing and commissioning Portable Fire extinguishers of following type & capacity.ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
1148ABC powder type fire extinguisher of 5Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, floor trolley type / wall mounting bracket etc. complete, confirming to IS:13849.
1149GI Propeller FansSupplying, installing, testing and commissioning of direct driven PROPELLER FANS .No. fan shall be complete with permanent split capacitor or shaded pole motor, mounting plate with light weight type GI impellers with aerofoil contours for high efficiency & low noise & gravity louvers for weather protection as required. Fan selection arrangement and Electrical characteristics shall be as follows :c) Air Quantity : 450 mm Dia, 3 mm St. Pr., 900 RPM or as per OEM, fan suitable for 220± 5% volts 50 cycles, 1 phase AC Power supply as Required
1150Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)450 lpm at 35 m Head
1151Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100m Dia
1152Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
1153Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
1154Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)
1155Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
1156Providing & Installation of Fire Hydrant 80 mm Bronze Landing Fire Hydrant Valve Flanged 1093
1157ELECTRICAL WORKWIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1158Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
11592 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
11602 X 4 sq. mm + 1 X 4 sq. mm earth wire
1161Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1162Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
116315/16 A switch
11643 pin 5/6 A socket outlet
11656 pin 15/16 A socket outlet
1166Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1167Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1168Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
11696 Module (200mmX75mm)
1170Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
11716 Module
1172Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
1173Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1174Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
1175Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
1176Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
1177MCCB, MCB & DB'SSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
1178Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1179Double pole
1180Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1181Supplying and fixing following rating, double pole, (single phase and neutral),240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections,testing and commissioning etc as required.240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A
1182EARTHINGEarthing with G.I. earth pipe 4.5m long 40mm dia, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1183Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1184Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1185LIGHTING CONDUCTOR Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required
1186Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
1187Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
1188LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P -I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 2 X 10sq.mm
1189Solar System Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
1190N.S.ITEMS:-Supplying, installation, testing and Commission of following luminaries complete with all accessories such as ballast,drivers, starter etc. mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the consultant 36W LED Tube Light
119118W LED Tube Light
1192LED Bulb with holder/ceiling light
1193Supply and insatallation of 300 mm sweep metalic ventilating/exhaust fan 900 RPM heavy duty Usha or equivalent make
1194Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
11953-Phase New Power Supply Connection Charges
1196BORE WELLLabour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.Bore hole of 150mm diameter
1197Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent110mm diameter
1198Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.G.I. pipe (TATA / SAIL (Medium) socket should be welded to the pipes.)65mm diameter
1199Supplying fitting and fixing GI filter of 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
1200Supplying fitting and fixing brass Tezfilter 2.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
1201Supplying fitting and fixing ISI approved PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
1202Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.100mm diameter
1203Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department.65mm diameter
1204Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineerin-charge
1205Supply, installation testing & commissioning of submersible pumping set suitable to operate on 410 volts 3 phase 50 HZ A.C. power supply including water proof joint free cable, motor control panel, 50 mm dia, G.I. pipe (medium class) column with fittings, clamps etc. complete in all respect as per details given below : (For Borewell)Discharge 50 LPM.Head 65 mHP/Load 2 (Approx)
1206ESMP (Exact Amount to be quoted as per Bid Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58209577
AUTHORITY Government Departments
TENDER VALUE 15.50 Crore
LAST DATE 25-11-2026
Authority
Authority Name Assam State Disaster Management Authority
Work Description Tender for Procurement Of Civil Works For New Micro Flood Shelters At Different Locations Of Assam Under Assam Integrated River Bank Management Project (Airbmp)
Basic Detail
Tender No IN-ASDMA-577965-CW-RFB
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 26 Oct 2026
Submission Date 25 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 15.50 Crore
Tender Fee Ref. Documents
EMD 31 Lakhs
Exemption Not Available
Document List
404279d5-7ee0-4e7b-8a7c-99a6b8657866.html
BOQ_85632.xls
RFBASDMAPrefabMB.pdf
TenderDrawingsPrefabMB.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 29 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
html

404279d5-7ee0-4e7b-8a7c-99a6b8657866.html

xls

BOQ_85632.xls

pdf

RFBASDMAPrefabMB.pdf

pdf

TenderDrawingsPrefabMB.pdf

pdf

Tendernotice_1.pdf

Disclaimer