Tender For Comprehensive Repair/Replacement And Misc Works At 39 Fad Area Under Age B/R-Ii Bharatpur At Bharatpur Mil Stn
Tender Value
49 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
18 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Repair/Replacement And Misc Works At 39 Fad Area Under Age B/R-Ii Bharatpur At Bharatpur Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of Asbestos sheet in roofing corrugated, or semi-corrugated sheets in roof covering of any thickness and description complete all as specified. |
| 2 | Pre- painted galvalume aluminum zinc coating GI based corrugated, semi corrugated or trapezoidal profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. |
| 3 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 5 | S&F hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165. |
| 6 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W (Gde-E-250) quality A complete all as specified. |
| 7 | S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified. |
| 8 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets complete all as specified. |
| 9 | M&L 4 mm thick high pressure steam cured non asbestos fibre cement designer building boards fixed or laid/inserted to Aluminium frame work with screws in ceiling flat or sloping complete. (Frame work for ceiling shall be measured and paid separately) complete all as specified. |
| 10 | S&F anodised aluminium snap grid frame work for false ceiling size of grid 605x605mm complete all as specified. |
| 11 | S&F for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. |
| 12 | S&F for PVC wall panelling in repair with panel of 300 mm x 6 mm Hollow section of Sintex pattern SPUF- 146 or equivalent , fixed with PVC plug and screw and inserted to next panel groove, edges and corners of all door/ window/openings etc to be covered with PVC angle fixed with solvent cement complete all as specified as manufacturer's instructions complete all as specified. |
| 13 | Demolition of brickwork or stone boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified. |
| 14 | M & L Brick work with sub-class 'B' bricks, straight or curved on plan exc 6 metre mean radius as wall built in cement & sand mortar 1:6 complete all as specified. |
| 15 | Taking down cement or cement lime plaster of any description from bricks or stone massonary walls includings raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 16 | M&L for Rendering 10 mm thick cement plaster in cement mortar (1:6) on fair faces of brick works or concrete surfaces , finished even and smooth without using extra cement,complete all as specified. |
| 17 | M&L for Rendering 5 mm thick cement plaster in cement mortar (1:3) on fair faces of concrete surfaces as in ceilling upto 6mtr height,including finishing the surface even and smooth without using extra cement, complete all as specified. |
| 18 | M&L for rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces including finishing the surface even and smooth, complete all as specified. |
| 19 | M&L for preparation of newly plastered or un plastered surfaces of walls and applying two coats of oil emulsion distempering white or tinted (copolymer based resin glue to be added for longer durability and better finish) using hand roller over one coat of water based white pigmented alkali resistant priming paint conforming to IS:109-1968, over wall Surface including all necessary arrangement for execution of work complete all as specified. |
| 20 | M&L for preparation of newly plastered surfaces of ceilling and applying two coats of oil emulsion distempering white or tinted over a coat of alkali resistant primer complete all as specified. |
| 21 | M&L for preparation of new plastered surface of wall including cornices, pilasters etc and applying two coat of cement based paint using hand roller, over one coat of water based white pigmented alkali resistant priming paint conforming to IS:109-1968, of approved colour/camouflaging pattern complete all as specified. |
| 22 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the remises complete all as specified. |
| 23 | M & L for non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exc 0.18sqm but not exc. 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or colour cement to match the floor, laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified. |
| 24 | M & L for non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exc 0.06sqm but not exc. 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or colour cement to match the floor, laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified. |
| 25 | M&L for glazed ceramic tiles, coloured/printed tiles in vertical surface of size 450x300x7 mm thick, laid over and including 15 mm thick rendering in cement mortar (1:3) and set and jointed in neat cement slurry & pointed in white cement with pigment to match the colour of tiles, complete all as specified. |
| 26 | Dismantling water tanks of capacity exceeding 500 and not exceeding 1000 liters including taking down old ball valves complete all as specified. |
| 27 | Dismantling water tanks of capacity exceeding 250 and not exceeding 500 liters including taking down old ball valves complete all as specified. |
| 28 | S&F tripple layer rotational moulded polyethylene water storage tanks, white with treaded type cover lid of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified. |
| 29 | All as item No 28 above but capacity 1000 Litres complete all as specified. |
| 30 | S & F in replacement Ball valves 20 mm bore, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified. |
| 31 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified. |
| 32 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified. |
| 33 | Taking down shutters of any description, area exceeding 1.00 sqm and n.exc 2.00 sqm each complete all as specified. |
| 34 | Taking down shutters of any description, area exceeding 2.00 sqm each complete all as specified. |
| 35 | S & F for powder coated anodised aluminium framed for doors, windows, ventilators with one or more rebates including joiniing cleats for fixing etc complete all as specified. |
| 36 | S & F powder coated anodised Aluminium window/ ventilator shutters side hungs type with sash, aluminium section weight not less than 0.55 kg/m including necessary joining cleats, rubber neoprene packing as per peg stay 150 mm long (1 No) suitable , type B-21 hinge 100mm long (2 No), handle (1 No) etc each leaf complete all as specified. |
| 37 | S&F powder coated anodised Aluminium door shutters with aluminium section weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, 02 Nos aluminium handle each door, hinges, beading clips etc complete all as specified. |
| 38 | S&F for 4.80 mm thick sheet glass with solar control film 25 micron reflective type sticked to glass pane ,odinary qulity and glazing with neosprene beading exc 0.5 Sqm in each pane complete all as specified. |
| 39 | S&F for 0.56 mm thick aluminium alloy sheeting fixed with screw on door shutter complete all as specified. |
| 40 | S & F factory made solid PVC moulded door shutter 28 to 30 mm thick (style) with 2 raised panel design with 2 mm thick moulded prelam PVC sheet on the front face and 2 mm prelam PVC sheet on back face in the frame at site, as per specifications and drawing. |
| 41 | S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm prelam PVC sheet & edges will be painted to match with prelam sheet, reinforced with MS Square tube etc complete all as specified. |
| 42 | S&F aluminium, anodised, 150mm long barrel tower bolts of extruded section and fixed complete all as specified. |
| 43 | Door closer hydraulically regulated designation No 3, univeral type, of aluminium (extruded section body) suitable for door shutters of 851 to 1000 mm in width and of weght between 61 to 80 kg and fixed complete all as specified. |
| 44 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or from metal frame or stone or concrete or bricks surrounds glazesd with putty, taking out old pins punching or drilling out, complete all as specified. |
| 45 | S & F Sheet glass 4 mm thick, ordinary quality & glazing with oil putty in squares n.exc 0.5 sqm in each pane including provision of glazing pins/spring clips, complete all as specified. |
| 46 | S&F Butt hinges medium weight cold rolled mild steel of 100 mm size and fixed ,complete all as specified. |
| 47 | S&F Aluminium handles , cast type anodised of 150 mm size , complete all as specified. |
| 48 | Painting to new steel or steel based surfaces of any description, not otherwise described over 10cm width or girth including preparation of surfaces, priming with red oxide zinc chrome primer (one coat) & finishing with two coats of synthetic enamel paint complete all as specified. |
| 49 | Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc complete all as specified. |
| 50 | S&F GI tubing medium grade ISI marked with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified. |
| 51 | Cutting or uprooting grass incl removing old mud phuska/ roof treatment of 80mm thick (avarage) and description, removing rubbish off the premises, cleaning surface and preparing to receive new treatment complete all as specified. |
| 52 | M&L for screed bed or bedding layer of cement mortar 1:4, 20 mm thick finished even and smooth without using extra cement complete all as specified. |
| 53 | M&L for preparing surfaces for roof treatment by removing all loose gravel, dirt, oil, grease and foreign matter by jet of dry air and clean the surfaces mechanically or by grinding to make it smooth before application, provide 75 mm x 75 mm covering made out of PMC mortar as above on all joints of vertical upstands to ensure does not exceed 5% immediately before application of liquid membrane. Material incorporation & Protection be provided, applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having sun reflectivity index (SRI) of 105 on top of concrete roof in three coats @ 10.76 ltr/10Sqm with 1st coat applied in water ratio (ratioi elastomeric liquid water proofing membrane water will be 3:1) on primer, after athe 1st coat is completely dry become slightly darker than apply 2nd coat with undiluted elastomeric water proofing liquied in criss-cross direction with roller.Spread glass fibre mesh reinforcement of 1mm thickness with overlap of 50mm in both direction when the surface is still tacky. After the drying of 2nd coat completely applying the final coat of undiluted elastomeric water proofing liquid in direction perpendicular to privious coat. The min thickness of dry film of complete application should not be less than the as recommended by manufacture the overall dry thickness should not be in any case less than 1.5mm complete all as specified. |
| 54 | Taking down carefully copper/aluminium point wiring (light, fan, bell,same board, independent or power) complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials and making good disturbed surfaces of wall, floor & ceiling etc complete all as specified. |
| 55 | Dismantling of old U/S sub main wiring and service wire of any size & make complete all as specified. |
| 56 | Dismantling of old U/S rusted main switch/DB of any size capacity and make complete all as specified. |
| 57 | M&L concealed point wiring complete with 1.5 Sqmm 02 x single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in PVC conduit pipe size not less than 20 mm dia with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the concealed surface and making good the disturbed surfaces of wall/ceiling by means of Wall putty and matching colour of existing wall, PVCsleeve/dash fastners with cadmium plated screws including suitable size of PVC boards/ sunken box for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm PVC insulated but FRLS unsheathed copper earth continuity conductor to common earth and connected to earth dolly complete all as specified for the following :- |
| 58 | (a) One light point controlled by one way switch complete all as specified. |
| 59 | (b) One fan point controlled by one way switch complete all as specified. |
| 60 | (c) One 3 pin 6 Amp socket point outlet on the same board with other switches complete all as specified. |
| 61 | (d) One 3 pin 6 Amp socket point outlet on the independent board complete all as specified. |
| 62 | (e) One bell/buzzer point controlled by one push button complete all as specified. |
| 63 | All as item No 57 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps socket point outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified. |
| 64 | M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleeved/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated FRLS unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly for the following :- |
| 65 | (a) One light point controlled by one way switch complete all as specified. |
| 66 | (b) One fan point controlled by one way switch complete all as specified. |
| 67 | (c) One 3 pin 6 Amp socket point outlet on the same board with other switches complete all as specified. |
| 68 | (d) One 3 pin 6 Amp socket point outlet on the independent board complete all as specified. |
| 69 | (e) One bell/buzzer point controlled by one push button complete all as specified. |
| 70 | All as item No 59 above but with multi stranded copper conductor cable 2.5 Sqmm size for 3 pin 16 Amps switch socket outlet on independent board including 2.5 Sqmm copper cable PVC insulated FRLS unsheathed copper continuous earth wire including connecting to common earth dolly complete all as specified. |
| 71 | S&F ceiling rose surface bakelite three terminal ISI marked including suitable size of PVC board complete all as specified. |
| 72 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type multi purpose flush type 230 volt complete all as specified. |
| 73 | S&F switch piano flush button single pole one way 6 Amps 230 volt grade complete all as specified. |
| 74 | S&F switch piano flush button single pole one way 16 Amps 230 volt grade complete all as specified. |
| 75 | S&F socket 3 pin 16A, flush type complete all as specified. |
| 76 | S&F bell push flush type 5 Amps 230 volts grade complete all as specified. |
| 77 | M&L bell multi musical type 230 volts grade complete all as specified. |
| 78 | S&F in repair step type electronic fan regulator EME type 100 watt complete all as specified. |
| 79 | M&L concealed submain wiring complete with 10 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 10 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 25 mm dia with all PVC accessories complete all as specified.Note: Two runs of 10 sqmm and one run of 10sqmm earth conductor and PVC conduit pipe shall be measured as one length only. |
| 80 | M&L concealed submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories complete all as specified.Note: Two runs of 6 sqmm and one run of 6 sqmm earth conductor and PVC conduit pipe shall be measured as one length only. |
| 81 | M&L concealed submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories complete all as specified.Note: Three runs of 4 sqmm and PVC conduit pipe shall be measured as one length only. |
| 82 | Supply and fix in repair of distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt, 415V of the following DBs:- |
| 83 | (a) 4 way TPN with busbar 415 volts (double door) complete all as specified. |
| 84 | (b) 8 way SPN with 200 amps rated busbar 240 volts (double door type) complete all as specified. |
| 85 | (c) 4 Way SPN with 200Amp rated busbar 240V (Double door type) complete all as specified. |
| 86 | S&F in repair MCCB's, MCB's of following capacity :- |
| 87 | (a) MCB TPN 63 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified. |
| 88 | (b) MCB TPN 32 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified. |
| 89 | (c) MCB SP 6-32 Amps, 240 volts,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified. |
| 90 | (d) MCB SPN 40-63 Amps, 240 volt,Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified. |
| 91 | Supply and fixing in replacement of 20 watt LED tubelight fitting retro fit type 4Xfeet long with replacable rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified. |
| 92 | Supply and fixing sensor based 20 watt LED tubelight fitting batten type 4 X feet long with rod complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified. |
| 93 | S&F in repair lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all incl 9 watt LED lamp complete all as specified. |
| 94 | S & F in repair street light GI bracket of 0.6 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole complete all as specified. |
| 95 | S&F in repair 35/36 watts LED street light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source connecting with 2.5 sq mm solid aluminium conductor PVC insulated twin core weather proof cable from fittings to jucntion box and fixing to complete all as specified. |
| 96 | S&F in repair LED light fitting 14 W,230V decorative wall mounting type with multicolour ABS housing with poly carbonate rings and glass shade with lamp holders & Bulb with connector block,etc complete with all accessaries pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified. |
| 97 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified. |
| 98 | Supply and fixing in repair LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified. |
| 99 | Supply and fixing round/square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified. |
| 100 | S&F sheet metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of SP 20 Amps, 240 volts complete all as specified. |
| 101 | Supply & fix in repair 4 way VTPN Distribution Board (with provision for MCCB as incomer & MCB as outgoing) for suitable ofb MCCB with suitable bus bar & Prewired complete all as specified. |
| 102 | S&F in repair on existing location including taking out of existing MCCBs of following capacity complete all as specified. |
| 103 | (a) MCCB 415 volts 100 Amps 04 pole 16 KA Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified. |
| 104 | S & F or laying galvanised steel tubing Medium grade (ISI marked) of size 40mm bore grounting in wall for hanging of ceiling fan with proper fixing of hanging clip & finishing of wall complete all as specified. |
| 105 | S & F in replacement 4 sqmm solid conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular from over head ACSR conductor to fitting complete all as specified. |
| 106 | M & L in repair for Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.50 Mtr below the ground level connected to GI earth wire 4mm dia by means of bolts, nuts and washers protected by GI tubing light grade 15 mm dia uptoTest point, 20 mm dia GI watering pipe medium grade with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates with 8 mm reinforcement bors @ 15 cm c/c bothway complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in soft/loose soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm complete all as specified.(Note:- Up to7.5Mtr length of pipe of 15 mm dia and GI wire shall be deemed tobe included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5) will be measured separately under respective item |
| 107 | Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified. |
| 108 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified. |
| 109 | Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified. |
| 110 | Supply & spread unwashed dry river sand for sand cushioning for covering the under ground cable in trenches complete all as specified.. (Note :- Punning thickness shall be measured.) |
| 111 | M&L for cable protection cover with sub Class`B` bricks old size laid dry, flat perpendicular across the cable in trenches complete all as specified. |
| 112 | Supply, laying, testing & commissioning of LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- |
| 113 | (a) 16 Sqmm 4 core complete all as specified. |
| 114 | (b) 10 Sqmm 2 core complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender