Tender for Providing New Borewell, Spectic Tank And Pathway Arrangemnets For Animal Shelter @ Vellakkal Kalkulam In Ward No - 92.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum |
| 2 | Supplying and filling in foundation and basement with filling Quarry Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification. |
| 3 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete |
| 4 | Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 5 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) |
| 6 | Reinforced Cement concrete 1:1.5 :3 (one cement, one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete. |
| 7 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. |
| 8 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9\\"X43/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 9 | Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 10 | Supplying and fixing in position C.I.Manhole covers (light or heavy duty) of 60 X 60cm in size in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), of best approved quality and as per standard specifications etc.,complete. |
| 11 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit. Upto 60 m Depth ending below ground level |
| 12 | From 60 m upto 90 m Depth ending from ground level |
| 13 | From 90 m upto 120 m Depth ending from ground level |
| 14 | Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by TWAD Officers and conducting yield test by ‘V’ notch method. |
| 15 | Supply and Delivery of PVC CASING PIPE AS PER IS 12818 / 2010 150 mm Dia |
| 16 | Labour charges for inserting casing pipes assembly (With slot or without slot) in the drilled hole including welding the joint etc., complete and supplying and packing the annular space with pebbles of size and quality as approved by the Executive Engineer |
| 17 | Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % |
| 18 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ (± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). |
| 19 | Supply and Delivery of PVC Insulated and Sheathed 3 Core Flat Type Copper Cable 4.0 sq.mm Conforming To Is 694/1990 And As Amended Thereafter |
| 20 | Supply and Delivery of UPVC and PVC Pipe and Specials 40mm UPVC Pipe |
| 21 | Nylon Rope (PWD Data 25 - 26) |
| 22 | 32mm GM non return Valve |
| 23 | 32mm GI Elbow |
| 24 | 32mm PVC Pipe (PWD Data 25 - 26) |
| 25 | 32mm PVC Coupling (PWD Data 25 - 26) |
| 26 | 32mm PVC Tee (PWD Data 25 - 26) |
| 27 | 32mm PVC Elbow (PWD Data 25 - 26) |
| 28 | 40mm Clamp set |
| 29 | 150mm borewell cover |
| 30 | Labour charges for the erection of submersible pumpset in borewell/ openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. |
| 31 | Construction of Borewell chambers of following sizes with earth work excavation for foundation with Dust Filling 10mm thick and Plain cement concrete bed in C.M. 1:5:10 using 40mm HBG jelly 10mm thick for foundation, 23cm thick brick wall work in C.M. 1:5 for chambers, Inner and Outer Plastering with C.M. 1:3 12mm thick, benching, channelling, 75mm thick RCC loose slab covering in C.M. 1:2:4 mix using 20mm blue granite jelly including necessary reinforcement, etc., complete |
| 32 | Providing and laying ,spreading and compacting 0.396 m3 of 45-22.40mm & 0.528 m3 of 22.40-2.36mm & 0.396m3 of 2.36mm and below metal graded stone aggregate to wet mix macadam (WMM ) soecification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications. |
| 33 | Supply and Installation of Air-Conditioner with Copper Coil 1.5 TR Split Type AC Unit - 5 Star Rated |
| 34 | Supply and Installation of Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay |
| 35 | Supply and Installation of Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 36 | Supply and fixing of MS stand for fixing outdoor unit |
| 37 | Add GST 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender