Tender For Construction Of Library Building At High School Bandiyo Under Chandrapura Block Bokaro.
Tender Value
99.74 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
10 days left
EMD
1.99 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bokaro → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Library Building At High School Bandiyo Under Chandrapura Block Bokaro.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 3 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 4 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 6 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 7 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 8 | Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 10 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 20 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 24 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 27 | Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle thresholdof mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge |
| 28 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 29 | Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 30 | Providing TMT steel reinforcement 8mm dia rods to 12mm dia as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I. |
| 31 | 8mm dia--20% |
| 32 | 10mm --15% |
| 33 | 12 mm--40% |
| 34 | 16mm--25% |
| 35 | supplying, fitting and fixing 250X20X6mm L-type M.S clamp properly fishtailed, including maiking holes and setting as same in 250X125X75mm. Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I. |
| 36 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 37 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 38 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 39 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 40 | Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 41 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matchingpigments etc., complete. |
| 42 | Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. |
| 43 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 44 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 45 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 46 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 48 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 49 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 50 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 51 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 52 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 53 | Providing and laying vitrified Paring / Industrial tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 4457:2007, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 300x300 x 10 mm sizes. |
| 54 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : |
| 55 | For fixed portion--Powder coated aluminium (minimumthickness of powder coating 50 micron) |
| 56 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : |
| 57 | For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately)Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : |
| 58 | Providing and fixing glazing in aluminium door, window,ventilatOR shutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 59 | Providing and fixing 12 mm thick prelaminated particle board flatpressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screwsetc. complete as per architectural drawings and directions of engineerin-charge. |
| 60 | Providing and fixing glazing in aluminium door, window,ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item): |
| 61 | With float glass panes of 8 mm thickness (weight notless than 20 kg/sqm) |
| 62 | Carriage of materials |
| 63 | Bricks Lead = 1 k+7 P(8km) |
| 64 | Sand lead = 20 km |
| 65 | Stone chips lead = 20 km |
| 66 | Stone metal lead = 20 km |
| 67 | Fly Ash (8km) |
| 68 | Earthwork in excavation(As per I.S. 3114/1965 for laying of different types and sizes of pipe so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. |
| 69 | (a) For classification of soil item - A (60 x 0.6 x 0.6 ) |
| 70 | Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification for soil item-A& B |
| 71 | Supplying and fixing male ended 15 mm dia brass bib cock of approved quality (wt. not less than 350 grms) with extra socket all complete as per specification and direction of E/I. |
| 72 | Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. |
| 73 | (A) BRASS STOP COCK |
| 74 | (a) 15 mm dia |
| 75 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I. |
| 76 | 32 mm and weight not less than 700 gms. |
| 77 | 40 mm and weight not less than 1.0 kg. |
| 78 | Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. |
| 79 | (A) 580mm long width (C) With 10 lit low level P.V.C. cisterns |
| 80 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. |
| 81 | Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I. |
| 82 | (i)125mm thick wall |
| 83 | (ii)250mm thick wall |
| 84 | Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING |
| 85 | piller Cock (Long Neck) (for basin) |
| 86 | Angular Stop Cock (Long Thread) |
| 87 | Towel Rail 24\\" |
| 88 | Tumbler Holder |
| 89 | Toilet Paper Holder |
| 90 | Glass shelf 22' |
| 91 | Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. |
| 92 | (for classification of soil items A) = 2 X60.00 X 0.60 X 0.45 |
| 93 | Labour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I. |
| 94 | (a) 150 mm dia pipe |
| 95 | Supplying labours, tools and tackles for testing of laid, R.C.C. spun pipes upto specified lead water all complete as per specification and direction of E/I. (water to be supplied free of cost departmentally). (iii) 225mm dia |
| 96 | Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I. |
| 97 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of |
| 98 | 20 mm nominal outer dia |
| 99 | 25 mm nominal outer dia |
| 100 | 32 mm nominal outer dia |
| 101 | Providing and fixing PTMT grating of approved quality and colour. Circular type - 100 mm nominal dia |
| 102 | 125 mm nominal dia with 25 mm waste hole |
| 103 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. |
| 104 | Mirrors of 6mm thick glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror |
| 105 | 600mm x 450mm size |
| 106 | Polythene water storage tank of ISI mark (eg Sintex /Sinter /himgiri/gangotri etc with cover & locking system |
| 107 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes |
| 108 | 110 mm Rain water pipe--waste pipe |
| 109 | Coupler 110 mm |
| 110 | Bend - 110mm |
| 111 | Shoe - 110 |
| 112 | Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exaust fan point / callbellpoint with 1.5sq.mm FRPVC insulated copper conductor single core cable in surface/recrssed PVC conduit,with modular type switch, modular plate, suitable size G.I. box etc.as required. |
| 113 | Group B |
| 114 | Group C |
| 115 | Twin Control Point wiring in PVC conduit, with modular type switch:-Wiring for Twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch,modular plate, sutiable size G.I box etc as requried. |
| 116 | G.F + F.F |
| 117 | Circuit /sub main wiring in PVC conduit :-Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried. |
| 118 | 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 119 | 2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
| 120 | 2x4.0 sq.mm + 1x4.5 sq.mm earth wire |
| 121 | 2x10 sq.mm + 1x10 sq.mm earth wire |
| 122 | M.S.BOARD |
| 123 | S/V PVC/ G.I. boxes :- Supplying and fixing PVC/G.I box of following sizes on surface or in recessed with sutiable size of phenolic laminated sheet cover infront including painting etc as requried. |
| 124 | 75 mm x 75 mm x 50 mm deep / (4\\" x 4\\" ) |
| 125 | 72 mm x 146 mm x 48 mm deep / (4\\" x 7\\" ) |
| 126 | 210 mm x 206 mm x 48 mm deep / (10\\" x 12\\" ) |
| 127 | 9W, High efficient recess mounted COB LED downlighter with extruded aluminium housing. High efficiency 38 Deg beam reflector optics for effictive thernmal management using aluminium casting. CRI>80, CCT - 4000K,50,000 hrs @ L70 life. IP20, Ambient temp- 0 to 45 DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Cutout Dia-ø90mm. Luminaire lumen ≥ 900 lm. (100 lm/W). Similar to Wipro Make LD98-131-038-40-XXor Equivalent Philips make. |
| 128 | Gound Floor |
| 129 | Maximum 12W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP40, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 1320 lm with Minimum 110 lm/W system efficacy. Cutout Dia-ø110mm. Similar to Wipro Make LD06-151-XXX-40-XX or Equivalent Philips make. |
| 130 | Ground Floor |
| 131 | 9\\" (230mm) metal exaust fan |
| 132 | Bulk head fitting with 9/10 Watt CFL/LED |
| 133 | S/F celling rose :- Supplying and fixing 2 pin 5 amp. Celling rose on the existing junction box/ wooen block including connection etc. as requried. |
| 134 | Ground Floor |
| 135 | S/F Batten holder :-Supplying and fixing battrn / angle holder including connection etc as requried. |
| 136 | G.F+F.F |
| 137 | ITC fluorescent fitting directly on surface :-Intallation testing and commissioning of pre wired fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on celling / wall including connection with 1.5 sq. mm. FR PVC insulated copper conduit as requried. |
| 138 | Ground Floor |
| 139 | ITC celling fan :- Installation, testing and commissioning of celling fan, including wiring the down rods of standerd leanth (upto 30 mm) with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as requried. |
| 140 | Ground Floor |
| 141 | ITC Exhaust fan upto 450 mm. sweep:-Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the holeto suit the size of the above fan, making good the damage, connection, testing, commissioning etc as required. |
| 142 | Same as exhaust fan quantity |
| 143 | Socket |
| 144 | S/F Modular type switch / socket :-Supplying and fixing following modular type switch /socket on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 145 | 5/6 amps, 3 pin socket outlet |
| 146 | S/F power plug point with modular type accessories :- Supplying and fixing sutiable size G.I. box with modular plate cover in front on surface or in recessed including providing and fixing 6 pin , 15/16 amps modular socket outlet and 15/16 amps modular switch connection , painting etc, as requried. |
| 147 | Ground Floor |
| 148 | S/F Modular type switch / socket :-Supplying and fixing following modular type switch /socket on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 149 | 5/6 amps, one way switch |
| 150 | S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried. |
| 151 | 32 amps, double pole |
| 152 | 63 amps, double pole |
| 153 | 32 amps, TP&N |
| 154 | S/F 'C' serise, MCB:-Suppling and fixing ,240 volts \\"C\\"serise miniature circuit breaker suitable for inductive loads of follong poles in the existing MCB DB complete with connections, testing and commisioning etc. as required . |
| 155 | 6/32 amps, Single pole |
| 156 | 40 amps, DP |
| 157 | S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) |
| 158 | 8 way , single door |
| 159 | 6way,single door |
| 160 | S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) |
| 161 | 4way, Double door |
| 162 | 16way,Double door |
| 163 | S/F Modular type Electronic Fan Regulator-Supplying and fixing following modular type lectronic Fan Regulator- on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 164 | S/F Modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate and switch box exculiding modular plate etc.as requried. |
| 165 | S/F SP MCB blanking plate :-Suppling and fixing Single pole blanking plate inexisting MCB DB complete etc. as required . |
| 166 | S/F HRC fuse type TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc as requried. |
| 167 | 400 amps, TP&N, HRC |
| 168 | S/F Panel montude change over:-Providing and fixing following capacity 4 pole panel mounted change over switches in existing cubcile panel board, making connection earthing the body etc as requried. |
| 169 | 400 amps, 4 pole |
| 170 | S/F Busbar chamber :-Providing and fixing following capacity busbar chamber with 4 strips of sutiable size made of copper, heavy duty, complete with all accessories including connections, earthing the body, etc as requried. |
| 171 | 400 amps |
| 172 | S/F HRC fuse type TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc as requried. |
| 173 | 200 amps, TP&N, HRC |
| 174 | S/F S.P. MCB DB :-Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphatize and powder painted inculiding earthing etc.as required.(But without MCB/RCCB/Isolator) |
| 175 | 4way (4+12), Single door,Horizontal type |
| 176 | S/F 'C' serise, MCB:-Suppling and fixing ,240 volts \\"C\\"serise miniature circuit breaker suitable for inductive loads of follong poles in the existing MCB DB complete with connections, testing and commisioning etc. as required . |
| 177 | 50/63 amps TPN |
| 178 | S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried. |
| 179 | 16 amps, double pole |
| 180 | Copper earth plate electrode:-Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclours with cover plate having locking arrangrment and watering pipe etc .as requried .(But with out charcoal or coke and salt). |
| 181 | S/L 8 SWG copper wire in ground:-Suppling and laying 8SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldring as requried. |
| 182 | S/L 25mm x6mm G.I. earth strip in ground :-Supplying and laying 25mm x6mm G.I. strip at 0.50 metre below ground as strip earth eletrode, incoluding soldering etc .as requried. |
| 183 | P/F G.I lighting conductor finial :-Providing and fixing of lighting conductor finial, made of 25 mm dia 300mm long, G.I tube, having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc as rqquried. |
| 184 | Reverting sweating and soldring lighting conductor tape:-Reverting sweating and soldring of copper / G.I tape (with another copper/ G.I tape, base of the final or any another metalic object) as requried. |
| 185 | P/F G.I lighting conductor tape in vertical run :-Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as requried.( for horizontal run ). |
| 186 | P/F coppre earth tape for lighting conductor :-Providing and laying copper tape 32 mm x 6 mm from earth electrode directly in ground as requried. |
| 187 | CABLE |
| 188 | 70 sq. mm, 3.5 core |
| 189 | 35 sq. mm, 3.5 core |
| 190 | MV cable laying up to 35 sq.mm in ground :-Laying of 1 number PVC insulated and PVC sheathed / XLPE power cable of 1.1 K V grade of size not exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requried. |
| 191 | MV Cable Laying upto 95 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required. |
| 192 | Supply of 48\\" (1200mm) AC ceiling fan |
| 193 | 20/22 watt LED tube light |
| 194 | 15/16 watt LED bulb |
| 195 | 30W LED Flood light |
| 196 | Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. |
| 197 | (a) From 0.00 M to 50.00 M below G.L. |
| 198 | (b) From 51.0 M to125.00 M |
| 199 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 200 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 201 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 202 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 203 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages(2 HP) |
| 204 | FR PVC insulated 3 core 4 sq.mm copper wire |
| 205 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 206 | Add 18 % GST (in Basic Rate must fill 12) |
| 207 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender