Housing Urban and Rular Development Government Departments Closing in 10 days TDR #58207272

Tender For Construction Of Library Building At High School Bandiyo Under Chandrapura Block Bokaro.

Issued by Government Departments · Bokaro, Jharkhand
Tender Value
99.74 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
10 days left
EMD
1.99 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bokaro → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Library Building At High School Bandiyo Under Chandrapura Block Bokaro.

BOQ

Name of Work:- Construction of Library Building at High School Bandiyo under Chandrapura Block Bokaro.
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
2Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
3Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
4Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
5Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
6Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
7Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
8Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
10Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
11Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
12Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
13Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
14Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
15Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
16Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
17Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
18Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
19Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
20Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
21Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
22Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
23Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
24Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
25Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
26Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
27Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle thresholdof mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge
28Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
29Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
30Providing TMT steel reinforcement 8mm dia rods to 12mm dia as per approved design and drawing excluding carriage of M.S. roads (Straight or in coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
318mm dia--20%
3210mm --15%
3312 mm--40%
3416mm--25%
35supplying, fitting and fixing 250X20X6mm L-type M.S clamp properly fishtailed, including maiking holes and setting as same in 250X125X75mm. Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I.
36Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
37Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
38Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.
39Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
40Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
41Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matchingpigments etc., complete.
42Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete.
43Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
44Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
45Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
46Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
47Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
48Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
49Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
50Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
51Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
52Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
53Providing and laying vitrified Paring / Industrial tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 4457:2007, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 300x300 x 10 mm sizes.
54Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :
55For fixed portion--Powder coated aluminium (minimumthickness of powder coating 50 micron)
56Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :
57For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately)Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :
58Providing and fixing glazing in aluminium door, window,ventilatOR shutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
59Providing and fixing 12 mm thick prelaminated particle board flatpressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screwsetc. complete as per architectural drawings and directions of engineerin-charge.
60Providing and fixing glazing in aluminium door, window,ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item):
61With float glass panes of 8 mm thickness (weight notless than 20 kg/sqm)
62Carriage of materials
63Bricks Lead = 1 k+7 P(8km)
64Sand lead = 20 km
65Stone chips lead = 20 km
66Stone metal lead = 20 km
67Fly Ash (8km)
68Earthwork in excavation(As per I.S. 3114/1965 for laying of different types and sizes of pipe so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.
69(a) For classification of soil item - A (60 x 0.6 x 0.6 )
70Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification for soil item-A& B
71Supplying and fixing male ended 15 mm dia brass bib cock of approved quality (wt. not less than 350 grms) with extra socket all complete as per specification and direction of E/I.
72Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I.
73(A) BRASS STOP COCK
74(a) 15 mm dia
75Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.
7632 mm and weight not less than 700 gms.
7740 mm and weight not less than 1.0 kg.
78Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.
79(A) 580mm long width (C) With 10 lit low level P.V.C. cisterns
80Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
81Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I.
82(i)125mm thick wall
83(ii)250mm thick wall
84Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit) ALL JAGUAR FITTING
85piller Cock (Long Neck) (for basin)
86Angular Stop Cock (Long Thread)
87Towel Rail 24\\"
88Tumbler Holder
89Toilet Paper Holder
90Glass shelf 22'
91Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.
92(for classification of soil items A) = 2 X60.00 X 0.60 X 0.45
93Labour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.
94(a) 150 mm dia pipe
95Supplying labours, tools and tackles for testing of laid, R.C.C. spun pipes upto specified lead water all complete as per specification and direction of E/I. (water to be supplied free of cost departmentally). (iii) 225mm dia
96Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
97Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of
9820 mm nominal outer dia
9925 mm nominal outer dia
10032 mm nominal outer dia
101Providing and fixing PTMT grating of approved quality and colour. Circular type - 100 mm nominal dia
102125 mm nominal dia with 25 mm waste hole
103Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
104Mirrors of 6mm thick glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror
105600mm x 450mm size
106Polythene water storage tank of ISI mark (eg Sintex /Sinter /himgiri/gangotri etc with cover & locking system
107Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes
108110 mm Rain water pipe--waste pipe
109Coupler 110 mm
110Bend - 110mm
111Shoe - 110
112Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exaust fan point / callbellpoint with 1.5sq.mm FRPVC insulated copper conductor single core cable in surface/recrssed PVC conduit,with modular type switch, modular plate, suitable size G.I. box etc.as required.
113Group B
114Group C
115Twin Control Point wiring in PVC conduit, with modular type switch:-Wiring for Twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch,modular plate, sutiable size G.I box etc as requried.
116G.F + F.F
117Circuit /sub main wiring in PVC conduit :-Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried.
1182x1.5 sq.mm + 1x1.5 sq.mm earth wire
1192x2.5 sq.mm + 1x2.5 sq.mm earth wire
1202x4.0 sq.mm + 1x4.5 sq.mm earth wire
1212x10 sq.mm + 1x10 sq.mm earth wire
122M.S.BOARD
123S/V PVC/ G.I. boxes :- Supplying and fixing PVC/G.I box of following sizes on surface or in recessed with sutiable size of phenolic laminated sheet cover infront including painting etc as requried.
12475 mm x 75 mm x 50 mm deep / (4\\" x 4\\" )
12572 mm x 146 mm x 48 mm deep / (4\\" x 7\\" )
126210 mm x 206 mm x 48 mm deep / (10\\" x 12\\" )
1279W, High efficient recess mounted COB LED downlighter with extruded aluminium housing. High efficiency 38 Deg beam reflector optics for effictive thernmal management using aluminium casting. CRI>80, CCT - 4000K,50,000 hrs @ L70 life. IP20, Ambient temp- 0 to 45 DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Cutout Dia-ø90mm. Luminaire lumen ≥ 900 lm. (100 lm/W). Similar to Wipro Make LD98-131-038-40-XXor Equivalent Philips make.
128Gound Floor
129Maximum 12W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP40, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<10%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 1320 lm with Minimum 110 lm/W system efficacy. Cutout Dia-ø110mm. Similar to Wipro Make LD06-151-XXX-40-XX or Equivalent Philips make.
130Ground Floor
1319\\" (230mm) metal exaust fan
132Bulk head fitting with 9/10 Watt CFL/LED
133S/F celling rose :- Supplying and fixing 2 pin 5 amp. Celling rose on the existing junction box/ wooen block including connection etc. as requried.
134Ground Floor
135S/F Batten holder :-Supplying and fixing battrn / angle holder including connection etc as requried.
136G.F+F.F
137ITC fluorescent fitting directly on surface :-Intallation testing and commissioning of pre wired fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on celling / wall including connection with 1.5 sq. mm. FR PVC insulated copper conduit as requried.
138Ground Floor
139ITC celling fan :- Installation, testing and commissioning of celling fan, including wiring the down rods of standerd leanth (upto 30 mm) with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as requried.
140Ground Floor
141ITC Exhaust fan upto 450 mm. sweep:-Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the holeto suit the size of the above fan, making good the damage, connection, testing, commissioning etc as required.
142Same as exhaust fan quantity
143Socket
144S/F Modular type switch / socket :-Supplying and fixing following modular type switch /socket on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried.
1455/6 amps, 3 pin socket outlet
146S/F power plug point with modular type accessories :- Supplying and fixing sutiable size G.I. box with modular plate cover in front on surface or in recessed including providing and fixing 6 pin , 15/16 amps modular socket outlet and 15/16 amps modular switch connection , painting etc, as requried.
147Ground Floor
148S/F Modular type switch / socket :-Supplying and fixing following modular type switch /socket on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried.
1495/6 amps, one way switch
150S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried.
15132 amps, double pole
15263 amps, double pole
15332 amps, TP&N
154S/F 'C' serise, MCB:-Suppling and fixing ,240 volts \\"C\\"serise miniature circuit breaker suitable for inductive loads of follong poles in the existing MCB DB complete with connections, testing and commisioning etc. as required .
1556/32 amps, Single pole
15640 amps, DP
157S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator)
1588 way , single door
1596way,single door
160S/F S.P. MCB DB :Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphate and powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator)
1614way, Double door
16216way,Double door
163S/F Modular type Electronic Fan Regulator-Supplying and fixing following modular type lectronic Fan Regulator- on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried.
164S/F Modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate and switch box exculiding modular plate etc.as requried.
165S/F SP MCB blanking plate :-Suppling and fixing Single pole blanking plate inexisting MCB DB complete etc. as required .
166S/F HRC fuse type TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc as requried.
167400 amps, TP&N, HRC
168S/F Panel montude change over:-Providing and fixing following capacity 4 pole panel mounted change over switches in existing cubcile panel board, making connection earthing the body etc as requried.
169400 amps, 4 pole
170S/F Busbar chamber :-Providing and fixing following capacity busbar chamber with 4 strips of sutiable size made of copper, heavy duty, complete with all accessories including connections, earthing the body, etc as requried.
171400 amps
172S/F HRC fuse type TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board, with ISI marked HRC fuses, including drilling holes in metal board, making connections, etc as requried.
173200 amps, TP&N, HRC
174S/F S.P. MCB DB :-Supplying and fixing following way single pole nutral , sheet, MCB dstribution board , 240 volts ,on surface/recess, complete with tinned copper busbar,nutralbusbar, earth bar,din bar, detachable gland plate,interconnection, phosphatize and powder painted inculiding earthing etc.as required.(But without MCB/RCCB/Isolator)
1754way (4+12), Single door,Horizontal type
176S/F 'C' serise, MCB:-Suppling and fixing ,240 volts \\"C\\"serise miniature circuit breaker suitable for inductive loads of follong poles in the existing MCB DB complete with connections, testing and commisioning etc. as required .
17750/63 amps TPN
178S/F rewireable double pole / TP&N switch disconnector:-Providing and fixing following capacity doble pole / TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as requried.
17916 amps, double pole
180Copper earth plate electrode:-Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclours with cover plate having locking arrangrment and watering pipe etc .as requried .(But with out charcoal or coke and salt).
181S/L 8 SWG copper wire in ground:-Suppling and laying 8SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldring as requried.
182S/L 25mm x6mm G.I. earth strip in ground :-Supplying and laying 25mm x6mm G.I. strip at 0.50 metre below ground as strip earth eletrode, incoluding soldering etc .as requried.
183P/F G.I lighting conductor finial :-Providing and fixing of lighting conductor finial, made of 25 mm dia 300mm long, G.I tube, having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc as rqquried.
184Reverting sweating and soldring lighting conductor tape:-Reverting sweating and soldring of copper / G.I tape (with another copper/ G.I tape, base of the final or any another metalic object) as requried.
185P/F G.I lighting conductor tape in vertical run :-Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as requried.( for horizontal run ).
186P/F coppre earth tape for lighting conductor :-Providing and laying copper tape 32 mm x 6 mm from earth electrode directly in ground as requried.
187CABLE
18870 sq. mm, 3.5 core
18935 sq. mm, 3.5 core
190MV cable laying up to 35 sq.mm in ground :-Laying of 1 number PVC insulated and PVC sheathed / XLPE power cable of 1.1 K V grade of size not exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requried.
191MV Cable Laying upto 95 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required.
192Supply of 48\\" (1200mm) AC ceiling fan
19320/22 watt LED tube light
19415/16 watt LED bulb
19530W LED Flood light
196Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
197(a) From 0.00 M to 50.00 M below G.L.
198(b) From 51.0 M to125.00 M
199Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
200Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
201Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
202Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
203Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages(2 HP)
204FR PVC insulated 3 core 4 sq.mm copper wire
205Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
206Add 18 % GST (in Basic Rate must fill 12)
207Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58207272
AUTHORITY Government Departments
TENDER VALUE 99.74 Lakhs
LAST DATE 06-11-2026
Authority
Authority Name Building Construction Department
Work Description Tender for Construction Of Library Building At High School Bandiyo Under Chandrapura Block Bokaro.
Basic Detail
Tender No 05/2026-27/EE/BCD/BOKARO
Bidding Type Tender
Location
City Bokaro
State Jharkhand
Key Dates
Publish Date 26 Oct 2026
Submission Date 06 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 99.74 Lakhs
Tender Fee 10000
EMD 1.99 Lakhs
Exemption Not Available
Document List
b449d99a-5fc0-4625-8a3f-ab26e1fd4619.html
BOQ_162669.xls
Corrigendum.pdf
F-2-Group-01.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

b449d99a-5fc0-4625-8a3f-ab26e1fd4619.html

xls

BOQ_162669.xls

pdf

Corrigendum.pdf

pdf

F-2-Group-01.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender