Public Administrative Department Government Departments Closing in 4 days TDR #58207077

Tender For Annual Plan-Velloor Gp Project No 236/26-27-Parayippadi Anganwadi Electrification-General Electrical Work

Issued by Government Departments · Kottayam, Kerala
Tender Value
78201
Estimated cost
Bid Submission
03 Nov 2026
4 days left
EMD
1955
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Plan-Velloor Gp Project No 236/26-27-Parayippadi Anganwadi Electrification-General Electrical Work

BOQ

Name of Work:- Annual Plan-Velloor Gp Project NO 236/26-27-Parayippadi Anganwadi Electrification-General Electrical Work
Sl. No. Item Description
1Velloor GP Anganwadi Electrification Works-( Materials used for the work shall be as per list of materials approved by the District level technical committees and attached as separate document)
290.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
390.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
490.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
590.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
6OD230314/2026-2027:SUPPLY AND FIXING ANGLE / STRAIGHT BRASS LINED SKIRT TYPE, BAKELITEBATTEN HOLDER WITH 200MM POLISHED SHADE WITH 9W LED AND GIVINGCONNECTION ETC AS REQUIRED
7OD230313/2026-2027:SUPPLY AND INSTALLATION OF 150 MM MEDIUM DUTY 2300 RPM ,4 LEAFEXHAUST FAN IN PLASTIC FRAME (ALMONARD/CROMPTON MAKE) INTHE EXISTING OPENING, FIXING NECESSARY BOLT AND NUTS, MAKINGGOOD THE DAMAGES ETC. AS REQUIRED INCLUDING GIVINGCONNECTIONS WITH REQUIRED LENGTH OF 24/0.20M 3CORE ROUNDCOPPER CONDUCTOR FLEXIBLE CHORD ETC AS REQUIRED
890.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
990.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
1090.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
11OD230311/2026-2027:SUPPLY AND FIXING CAST ALUMINIUM STOVE ENAMELED BULK HEAD FITTINGWITH DEEP DRAWN ANODISED ALUMINIUM BODY, EPOXY POWDER COATED,HEAT RESISTANT PRISMATIC GLASS COVER WITH 9 W LED TO WALL / CEILINGINCLUDING GIVING CONNECTIONS WITH REQUIRED LENGTH OF 16/0.20MM PVCINSULATED AND PVC SHEATHED 3 CORE ROUND COPPER CONDUCTOR FLE XWIRE CONFORMING TO RELEVANT ISS OR EXTENDING THE ORIGINAL WIRINGAND MAKING GOOD THE SURFACE ASREQUIRED.(MEPRO/PHILIPS/CROMPTON/BAJAJ MAKE)
1290.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1390.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
1490.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1590.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
161.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
171.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
181.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
192.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
202.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
212.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
222.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
23OD230316/2026-2027:SUPPLY AND PROVIDING 12X3 MM BRASS BOLT AND NUT WITH WASHERS ONTHE EXISTING MS BOX / EARTH BUS ETC. AS REQUIRED INCLUDING DRILLINGNECESSARY HOLES AS REQUIRED
24OD230312/2026-2027:SUPPLY AND PROVIDING 25X6 MM BRASS BOLT AND NUT WITH WASHERS ONTHE EXISTING MS BOX / EARTH BUS ETC. AS REQUIRED INCLUDING DRILLINGNECESSARY HOLES AS REQUIRED
255.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
2690.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
271.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
281.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
291.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
301.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
3190.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
321.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
331.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
341.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
3590.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
3690.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
37OD230315/2026-2027:Supply and fixing dust and vermin proof 300 x 300 x 170 mm single phase meter box with base plate, one set of 32 A fuse unit, 32/25 A HRC fuse link, 32 A 2 way neutral link32 A, 2 Way neutral links mounted on DMC/SMC base, giving connection as required.
38OD230317/2026-2027:SUPPLY AND PROVIDING ANCHOR BOLT HOOK TYPE ON WALL /PARAPET FORBINDING KSEB SERVICE CONNECTION CAPABLE AS REQUIRED
39OD230310/2026-2027:CHARGES FOR PREPARING DRAWING OF THE COMPLETE ELECTRICALINSTALLATION AFTER COMPLETION OF THE PRESENT WORK AND PREPARINGCOMPLETION REPORT WITH KSEB SERVICE CONNECTION APPLICATION FORMAND SUBMITTING TO THE CONSUMER FOR AVAILNG 1 PHASE SERVICECONNECTION/LOAD REGULARIZATION Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58207077
AUTHORITY Government Departments
TENDER VALUE 78201
LAST DATE 03-11-2026
Authority
Authority Name Local Self Government Department
Work Description Tender for Annual Plan-Velloor Gp Project No 236/26-27-Parayippadi Anganwadi Electrification-General Electrical Work
Basic Detail
Tender No ET4/AE/LIDEW/VLR/2026-27
Bidding Type Tender
Location
City Kottayam
State Kerala
Key Dates
Publish Date 26 Oct 2026
Submission Date 03 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value 78201
Tender Fee 555
EMD 1955
Exemption Not Available
Document List
8d427fae-3fda-4ad4-9300-b1407fd43e4a.html
BOQ_1501978.xls
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

8d427fae-3fda-4ad4-9300-b1407fd43e4a.html

xls

BOQ_1501978.xls

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender