Tender For Construction Of Dak Bungalow At Kupwara
Tender Value
6.08 Crore
Estimated cost
Bid Submission
11 Nov 2026
10 days left
EMD
12.17 Lakhs
Bank guarantee accepted
Document Fee
8500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kupwara → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Dak Bungalow At Kupwara
BOQ
| Sl. No. | Item Description |
| 1 | (A) Civil Items |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m Sq. on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 3 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : |
| 4 | Providing and laying Stone soling hand packed incl ramming, watering etc cjob |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. (Back filling) |
| 7 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete. |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level |
| 9 | All works above plinth level upto floor V level |
| 10 | Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein |
| 11 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for : a. Foundations: footings, bases of columns etc. for mass concrete. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for : b. Suspended floors, roofs, landings, balconies and access platform. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for : c. Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : d.Columns, pillars, piers, abutments, posts and struts |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for : e. Stairs (excluding landings) except spiral staircases. |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation/ plinth & superstructure above plinth level upto floor five level including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 20 | Half brick masonry with common burnt clay (non-modular) bricks of class designation7.5 in superstructure above plinth level upto floor V level Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 21 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Imported (KD Wood) |
| 22 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 23 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Imported (KD Wood) (35mm Thick) |
| 24 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick Imported (KD Wood) |
| 25 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Imported (KD Wood) 35 mm thick |
| 26 | Providing and fixing 35mm thick wire guaze shutter using galvanized M.S wire gauze of average width for aperture 1.4m in both directions of wire dia 0.63mm for door,windows and clerestory windows with ISI marked M.S pressed butt hinges bright finish of required size mecessary screws as per directions of EIC Imported (KD Wood) |
| 27 | Providing and fixing 3.5mm including cost and fixing wooden fillets/ beeding of required size and shape with nail incl all carriage complete |
| 28 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 29 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete a..200x10mm |
| 30 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete b. 100 x 10mm |
| 31 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. a. 150mm |
| 32 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. b. 100mm |
| 33 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Single rubber stopper |
| 34 | Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive and other allied fixing material to fix it properly on base complete job |
| 35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600 mm x 600 mm |
| 36 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes reparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 37 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600 mm x 600 mm |
| 38 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 39 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (18mm Thick) |
| 40 | Providing edge moulding to 18 mm marble stone /granite stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge (Granite Work) Double moulding |
| 41 | 6 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 42 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 43 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand). Complete job |
| 44 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ( 2mm Thick) |
| 45 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 46 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (Two Coats) |
| 47 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 48 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 49 | Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade. Two or more coats on new work. |
| 50 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 51 | Making plinth protection with common burnt clay bricks of class designation 7.5 laid on edge in cement mortar 1:6 (1 cement : 6 coarse sand) with 12 mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) over 75 mm bed of dry brick aggregate 40mm nominal size rammed, consolidated and grouted with fine sand. The top of bricks pointed with cement mortar 1:3 (1cement: 3 fine sand) and curing complete |
| 52 | Carriage of materials by mechanical transport from source upto site of work including loading, unloading and stacking Stone aggregate 25mm below for an average lead of 35Km |
| 53 | Carrage of fine aggregate for avg lead of 85 kms |
| 54 | Carrage of bricks for avg lead of 100 kms |
| 55 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position including welding etc and applying a priming coat of approved steel primer all complete. |
| 56 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 57 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including all lifts,leads and carriages complete job a. Plinth area |
| 58 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 59 | Providing valleys of 90cm wide overall in plains G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G I. limpet and bitumen washers complete.1.25mm thick with zinc coating not less than 350gm/m2 |
| 60 | Providing and fixing plained eaves boarding. wood 2nd class Deodar wood 300x40 mm (nominal size) complete job |
| 61 | P/F 12mm thick imported wood as soffit including cost of frame work of KD wood underneath of required size as per directions of EIC including cost of primer and paint one or more coats involving all cost of labour,carriage, material , scraffolding cjob (Item to be executed as per directions of EIC) |
| 62 | Construction of Sokage pit of dry stone Masonery /Quarry Stone Incl. 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone agg 20 mm nominal size) Crusher (including all carriages of material from source to site of work complete ) |
| 63 | (B) Electric Works |
| 64 | Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Anchor/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider/ Havells/ Legrand/Anchor roma plus/ABB/Eq.Make & along with 2.5 Sqmm (P+N+E) Circuit Wire of same make as mentinoned above & items shall be approved before execution of work by SDO. |
| 65 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells/ Legrand/Anchor/Schneider /ABB/Eq Make & shall be approved before execution of work by SDO. |
| 66 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq Make) |
| 67 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified /Legran/Anchor roma plus/Schneider/ABB/Eq Make & shall be approved before execution of work by SDO. |
| 68 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq. Make) |
| 69 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Anchor roma plus/Schneider/ABB/Eq.Make & shall be approved before execution of work. |
| 70 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Anchor/ Eq.Make) & shall be approved before execution of work (Including Cost of Conduit/Channel) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 71 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 72 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 73 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 74 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240V,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq. Make) |
| 75 | Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Havells/ABB/Eq Make) 63 Amp. |
| 76 | 40 Amp. |
| 77 | 32 Amp. |
| 78 | Supplying and Fixing of MCB way 8 way (4 + 24), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make) |
| 79 | Supply/Installation/Testing and Commissioning of 18W + LED Conceal/Surface (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Jaquar/Wipro/Halonix/Eq Make. |
| 80 | Supply/Installation/Testing and Commissioning of 12W + LED Conceal/Surface (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Jaquar/Wipro/Halonix/Eq Make. |
| 81 | Supply/Installation/Testing & Commissioning of 10W LED Mirror Light of Jaquar/Wipro/Jaguar/ Eq.Make as duly fitted on walls including making of necessary Connections & sample shall be approved by EIC. |
| 82 | Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 lm of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 83 | Supply installation testing and commissioning of 36 W + LED Surface/recess Mounted square ( 2x2) light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Jaquar /Wipro make / sample to be approved before installation.. |
| 84 | Supply, Installation, Testing and Commissioning of decorative 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA Striker/Havells Oyster matalic/CromptonAura/ equivalent make as directed by engineer incharge. |
| 85 | Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Crompton/Eq. Make.(Min 1-Star) |
| 86 | Supply/Laying/Connecting and Commissioning of 120 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution) |
| 87 | Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel,fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint ,dust protected ,earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(I) Normal Incomer:a) 250 Amp-4-Pole ,35kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved=01 No.b) 500 Amps TPN Al. Bus Bar Set = 01 Set,Digital Voltmeter ,Ammeter ,C.T Coils with Selector Switch & Phase indicator Set.250 Amp. 4-pole changeover tp bypass between main supply and generator supply.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 63-Amp DP MCB = 06 No. for Heating Sub-main.(b) 40-Amp DP MCB = 06 No. for Lighting/Machine Sub-main(c) 32-Amp DP MCB = 16 No. for inverter Sub-main and AC Points |
| 88 | SITC of 32A Industrial type metal clad/Modular AC Box socket outlet with inter connections in heavy gauge powder coated duly fitted on wall with 32 Amp D.P MCB and 40 A 3 pin plug top complete with connections |
| 89 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job |
| 90 | Public Addressing System SITC of chairman microphone for the PA system should be a condenser gooseneck mic with a cardioid polar pattern, 50 Hz – 16 kHz frequency response, high signal-to-noise ratio (>60 dB), and XLR output for balanced audio. It should feature a priority override function, LED indicator, and adjustable gooseneck design for flexibility. The system should include supply, installation, testing, and commissioning, ensuring seamless integration with the existing PA setup, proper wiring, and audio calibration for optimal performance and with all accessories and mic holding stands. The installation should comply with industry standards, with testing conducted to verify clarity, range, and reliability before final handover Ahuja/Bosch/Eq. Make |
| 91 | SITC delegate microphone for the PA system should be a condenser gooseneck mic with a cardioid polar pattern, 50 Hz – 16 kHz frequency response, high signal-to-noise ratio (>60 dB), and XLR output for clear and balanced audio. It should feature a push-to-talk button, LED indicator, and adjustable gooseneck design for user convenience. The system should include supply, installation, testing, and commissioning, ensuring seamless integration with the chairman microphone and PA setup, proper wiring, and audio calibration for optimal clarity and along with mic holding stands. Installation should follow industry standards, with thorough testing to verify speech intelligibility, feedback rejection, and overall performance before final handover Ahuja/Bosch/Eq. Make |
| 92 | SITC of central amplifier for the PA system should be a high-power, rack-mountable unit with a Max. output of 300W,250W RMS at 10% THD ,220W RMS at 5% THD, 200W RMS at 2% THD , supporting 70V/100V line and low-impedance (4Ω/8Ω) speaker outputs. It should feature multiple balanced/unbalanced inputs (XLR, RCA, and ¼-inch jack), built-in DSP for equalization and feedback suppression, and automatic gain control (AGC) for consistent audio levels. Protection circuits for overload, short circuit, and thermal safety should be included, along with fan cooling for heat dissipation. The system should include supply, installation, testing, and commissioning, ensuring proper integration with microphones and speakers, impedance matching, and sound calibration and with all accessories. Installation should follow industry standards, with thorough testing for clarity, power handling, and reliability before final handover of Ahuja/Bosch/Eq. Make |
| 93 | SITC of Column type speakers for the PA system should be high-quality, full-range units with a power rating of 45W–30W RMS, supporting 70V/100V line and low-impedance (4Ω/8Ω) operation. Wide frequency response (150 Hz – 10 kHz), high sensitivity (95 dB SPL), dispersion angle ≥ 90° x 60°. Weather-resistant ABS/metal enclosure (IP-rated). Includes supply, installation, testing, and commissioning.Make: Ahuja / Bosch / Equivalent |
| 94 | SITC of cordless microphone for the PA system (VHF system, 500–900 MHz, 50–100m transmission range). Frequency response 50 Hz – 16 kHz, low latency, auto frequency selection, cardioid/supercardioid pattern. Rechargeable/AA battery (6–10 hrs operation). Receiver with balanced XLR & unbalanced 1/4-inch outputs, LED/LCD display, dual antennas. Includes supply, installation, testing, and calibration. |
| 95 | Supply, installation, mechanical erection, testing and commissioning of three phase 160 KVA diesel generator set (KIRLOSKAR / Cummins / Mahindra make). Turbo charged developing required BHP 1500 RPM under NTP with 10% overloading factor, six cylinder engine with 175 HP, microprocessor based digital display genset engine controller. Conforming to CPCB-IV norms. Complete job with suitable canopy.Make: Mahindra / Ashoka Leyland / Kirloskar / Eq. make |
| 96 | Carrying out foundation of PCC type, cement concrete to be carried in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of DG set etc. including frame work / Canopy etc. as required. Job includes supply and carriage of requisite material up to site. |
| 97 | Supply ,installation ,testing , &commissioning of 160 KVA 3 -Phase SERVO controlled VOLTAGE Stabilizer of Approved brand with following SPECIFICATIONS:(1). INPUT VOLTAGE: 156 Volt -450 Volts P-P (90V-260V N-P)(2) OUT PUT VOLTAGE : 400Volts+- 1%(230VAC)(3) Winding Material Insulation : 99.97% PURE COPPER WOUND FIBER GLASS(4). IN DOOR TYPE(5). COOLING :OIL 1S 335(6).MICRO CONTROLLED TRUE RMS Based LCD display(7). Protections are Over LoadCOPPER wound of Electric Field /Alba /AE /Cosco/Eq.make etc ISI/ISO certified for smooth functioning/ constant voltage supply having Technical Specifications:Input voltage= 90-260 volts & output voltage=220 volts+ - 2%Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL ,High cut/Low Cut /Time delay / Over Cut through Micro Control and Spike Protection including ,Carriages ,installation charges , testing & taxes complete job alongwith servo bypass switch of adequate rating. |
| 98 | Supply/Installation/Testing and Commissioning of 160 Amp Four Pole manual bypass changeover switch of Havells / Siemens/ ABB /Schinder /L&T/Eq make |
| 99 | 160 KVA Sub-Station SITC of 11/0.433kV, 160KVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al.wound upto 200kVA, Cu wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable.( X-mer without OCTC (Off Ckt Tap) |
| 100 | SITC 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 101 | SITC of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 102 | SITC of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 103 | SITC of 300sqmm single core Cable,1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type |
| 104 | SITC of 9 Mtr. Long Pole,(ST-410 SP33) |
| 105 | SITC of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kVNegative, creepage distance 320mm with fitting |
| 106 | SITC of GI Channel/Angle/Flat of sizes including clamps |
| 107 | SITC of Galvanized Nuts and Bolts. |
| 108 | SITC of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earthenhancement materials and Earth Chamber made of brick masonary with RCC slab cover. |
| 109 | SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm |
| 110 | SITC of 11KV Polymeric composite Pin Insulator 12KV, 5KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 111 | SITC of LT Distribution Box for 160 kVA DTR with 400 Amp MCCB 3P 25 kA |
| 112 | GI Barbed Wire for Anti Climbing |
| 113 | SITC of 3-Ø, HT Trivector Meter with CT ratio 15/5, PT 11KV/110V rated burden 15 VA per phase with all related accessories and standards as approved by KPDCL |
| 114 | Cement bottoming 1:2:4 mix as per Standards 0.48 cum/pole |
| 115 | Painting of Poles Red Oxide |
| 116 | Painting of Poles Aluminium Paint |
| 117 | Sundry items like Aluminium lugs, Jumpers, Binding Tape, |
| 118 | P/f of 0.05 ACSR Conductor |
| 119 | (C) PLUMBING WORKS SUB HEAD -I :SANITARY FIXTURES |
| 120 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. W.C. pan with ISI marked white solid plastic seat and lid |
| 121 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 122 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 123 | Providing and fixing kitchen/Lab sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required. White glazed fire clay kitchen/Lab sink of size 600x450x250 m |
| 124 | providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer-in-charg 32 mm dia |
| 125 | 40 mm dia |
| 126 | Providing Sink mixer (wall mounted) with 170mm long swivel spout connecting legs and wall flanges((CERA Cat. No. OCEAN F3002501 or approved equivalent) . |
| 127 | Providing and fixing Braided Hoses with Two 15mm CP Brass Nuts & Rubber Washers Without Nipple (Suitable for Geysers and basins) of approved make : 45 cm length a. 15 mm nominal bore |
| 128 | Providing and fixing toilet paper holder : CP Brass |
| 129 | Providing,Fixing,testing and commissioning of CP brass twin coat hook with concealed screws. |
| 130 | Providing and Fixing Health Faucet 15mmdia with CP flush pipe, CP nozzel hook complete including CP flange etc. |
| 131 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. . |
| 132 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 133 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 134 | Providing and fixing horzontal/vertical Hot water geyser made of MS body with copper jacket inside with necessary inlet, outlet, drain, overflow, vent and all safety accessories etc. complete including cutting and making good the walls, wherever required. a. 25 lit |
| 135 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 136 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms |
| 137 | SUB HEAD -II :SOIL, WASTE, VENT & RAIN WATER PIPES Providing and fixing UV stabilised UPVC pipes, Type B as per IS:13592 for soil, waste, rain water and vent, including all fittings with or without access i.e Clean out plug,bends, junctions, cowls, offsets, couplers, connectors, heavy duty Metal pipe clamps with rubber seal/clips//holders etc. and jointing with heavy duty solvent cement, complete as per manufacturer's specifications and making good the same, complete as directed by the Engineer-in-Charge. (vertical pipes can be jointed through rubber O rings) Inclouding cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm in bed and all around soil and waste pipes under floor, including shuttering and centering for: 75mm outer dia. |
| 138 | 110mm outer dia. |
| 139 | Insulation on pipe is use over all length of pipe as per requirement. Providing and fixing thermal insulation over pipes/fitting/Trap Etc as req. in exposed/chase with 32 mm thick approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 Kg/m3 over pipes of following sizes including all required accessories complete as per manufacturer's specifications and finishing it with 6mm thick rough plaster of 1:3 mix (1 Portland Cement : 3 hard settling cement compound)(Make-K-Flex,Eurobatex,Vidoflex.) 75mm outer dia. |
| 140 | 110mm outer dia. |
| 141 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 100mm dia pipe |
| 142 | Providing and fixing multi inlet uPVC floor trap with minimum 50mm water seal of self cleaning design with 110 mm outlet consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etc, complete including cost of cutting and making good the walls and floors wherever required and as directed by Engineer in charge. (The inlet diameter shall be 32mm, 40mm or 50mm as per site requirements) |
| 143 | Providing and fixing uPVC pipe as per IS 4985, Class-3, 6Kg/cm2 with cement solvent joint, complete with all fittings and clamps etc including cutting and making good the walls and floors for waste pipes from wash basins, urinals, sinks & balcony drainage, as directed by the Engineer-in-charge. 32 mm OD |
| 144 | 40 mm OD |
| 145 | 50 mm OD |
| 146 | Providing and fixing SS grating with frame including fixing to the floor with cement mortar. 100mm dia |
| 147 | Providing and fixing 110mmx50mm outlet. UPVC floor drain consisting of all necessary fittings and provding strainer of 150 x 150 mm square stainless steel 2 mm thk frame with slotted lockable grating on top of the trap level matching the level of floor finish etc all complete as per specifications and direction of Engineer-In-Charge. |
| 148 | Providing & fixing of cast brass clean out plug(floor/ceilling) with suitable insert keys for opening in: brass cap, male threaded joint with threaded G.I socket fixed to HCI soil pipe or C.I.(LA) pipe joints as required complete in all respects 110mm outer dia. |
| 149 | SUB HEAD -III :INTERNAL WATER SUPPLY PP-R should be a complete installation system consisting of pipes and fittings of a thermoplastic polopropylene PP-R 3-layer glass fibre compound (type 3/ type 4) of PN20 (SDR 6)/PN16 (SDR 7.4) and PP-RCT (SDR9 and SDR11) within a range of diameters 20-200 mm in Green/Grey colour of pipe dimension series in accordance with EN ISO 4065 having linear expansion of 0.05 mm/mK with DVGW and QB/CSTB certification as per EN ISO 15874-2:2013-06E, EN ISO 15874-3:2013-06E standard. System elements are connected by muff-welding (thermal polyfusion) or electrofusions welding with the use of electric welders. The welding technology i.e. uniform connections, guarantees an exceptional leak-tightness and mechanical strenth of a system and use for internal and external water supply, cooling systems (hot and cold water), production process industrial systems and use in shafts, basements, terrace with insulation. : MAKE : KAN-therm, Aquatherm, Poloplast Concealed work including cutting chases and making good the wall. 16x2 mm outer dia pipe |
| 150 | 20x2 mm pipe |
| 151 | 25x2.5 mm outer dia pipe |
| 152 | 32x3 mm outer dia pipe |
| 153 | PP-R should be a complete installation system consisting of pipes and fittings of a thermoplastic polopropylene PP-R 3-layer glass fibre compound (type 3/ type 4) of PN20 (SDR 6)/PN16 (SDR 7.4) and PP-RCT (SDR9 and SDR11) within a range of diameters 20-200 mm in Green/Grey colour of pipe dimension series in accordance with EN ISO 4065 having linear expansion of 0.05 mm/mK with DVGW and QB/CSTB certification as per EN ISO 15874-2:2013-06E, EN ISO 15874-3:2013-06E standard. System elements are connected by muff-welding (thermal polyfusion) or electrofusions welding with the use of electric welders. The welding technology i.e. uniform connections, guarantees an exceptional leak-tightness and mechanical strenth of a system and use for internal and external water supply, cooling systems (hot and cold water), production process industrial systems and use in shafts, basements, terrace with insulation. : MAKE : KAN-therm, Aquatherm, Poloplast Exposed on wall/terrace 16x2 mm outer dia pipe |
| 154 | 20x2 mm outer dia pipe |
| 155 | 25x2.5 mm outer dia pipe |
| 156 | 32x3 mm outer dia pipe |
| 157 | Insulation on pipe is use over all length of pipe as per requirement. Providing and fixing thermal insulation overr pipes in exposed/chase with 32 mm thick approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 Kg/m3 over pipes of following sizes including all required accessories complete as per manufacturer's specifications and finishing it with 6mm thick rough plaster of 1:3 mix (1 Portland Cement : 3 hard settling cement compound)(Make-K-Flex,Eurobatex,Vidoflex.) 25 mm dia |
| 158 | 32 mm dia |
| 159 | SUB HEAD -IV :EXTERNAL WATER SUPPLY Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work PN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 160 | PN - 10 Pipe, 50 mm OD (SDR-11) |
| 161 | Providing and fixing thermal insulation over pipes/fitting/Trap Etc as req. in exposed/chase with 32 mm thick approved equivalent thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber having density of 60-90 Kg/m3 over pipes of following sizes including all required accessories complete as per manufacturer's specifications and finishing it with 6mm thick rough plaster of 1:3 mix (1 Portland Cement : 3 hard settling cement compound) (Make-K-Flex,Eurobatex,Vidoflex.) 32x5.5 mm outer dia pipe |
| 162 | 50x6.9 mm outer dia pipe |
| 163 | Constructing masonry Chamber 60x60x75cm, inside with cement Brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size) and inside plastering with cement mortat 1:3 ( 1cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design. Cement Brick masonry, Size (Inches): 24 x 8 x 4 |
| 164 | Constructing masonry Chamber 60x45x50 cm inside, in cement Brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common Cement Brick masonry, Size (Inches): 24 x 8 x 4 |
| 165 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore |
| 166 | Effecting connection from Existing/ Municipal Water Supply line including necessary excavation & making good the same including cutting, boring and tapping the Existing line by providing and installing ferrule / Tee connections with necessary fittings as required and making good the same. The rate for this item also includes complete services from the contractor for liasoning works such as filing necessary applications, submission of forms for approval to the municipal authorities, depositing the fees / other amounts as required for getting the premises / installations, inspected and approved and all other formalities required till the water connection is obtained. All the expenses incurred in this regard shall be borne by the Contractor except for the official payments to be made for any security deposit etc. which will be reimbursed on production of original voucher. |
| 167 | SUB HEAD-V: EXTERNAL SEWAGE AND STORM WATER Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. Metre |
| 168 | Providing, laying, jointing and commissioning of PVC pipe As/IS:15328 with pussfit joint with solvent including testing of joints etc. complete as directed by Engineer in charge.(inclouding allround cement concrete). 150 mm dia. |
| 169 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating cement Brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type (With Sewer cement Brick conforming to IS : 4885 ) |
| 170 | Constructing cement Brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cms and 45 cms deep including CI cover with frame (Light duty) 610x455mm internal diamesions total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg) With common Cement Brick masonry, Size (Inches): 24 x 8 x 4 |
| 171 | Extra for depth for manholes (Size 90x80 cm) With common Cement Brick masonry, Size (Inches): 24 x 8 x 4 |
| 172 | Constructing cement Brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 20.9.10.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common Cement Brick masonry, Size (Inches): 24 x 8 x 4 |
| 173 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated asper IS: 10910 on 12mm dia steel bar conforming to IS :1786 having minimun cross section as 23 mm x 25 mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and heaving manufacture\\"s permanent identification mark to be visible even after fixing \\" incluting fixing in manholes with 30x20x15 cm cement concrete block 1:3:6: (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size )complete as per design. |
| 174 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc complete. For pipes 250 to 300 mm diameter |
| 175 | Constructing cement Brick masonry road gully chamber 50x45x60 cm with cement Brick in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common Cement Brick masonry, Size (Inches): 24 x 8 x 4 |
| 176 | Constructing cement Brick masonry road gully chamber 110x50x77.5 cm with cement Brick masonry in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : With common Cement Brick masonry, Size (Inches): 24 x 8 x 4 |
| 177 | SUB HEAD -VI : PVC OHT WATER TANK Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 178 | (D) BWO SITC OF FIRE ALARM SYSTEM |
| 179 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/LCD display with touch screen or other keypad and minimum 4000 events history logged in non-volatile memory (EPROM), power supply unit (230 ± 5% V, 50 Hz), 48 hrs back-up with 24 volt sealed maintenance-free batteries with automatic charger. Panel shall have facility to connect printer to printout log and facility for seamless integration with analog/digital voice evacuation system (part of schedule under SH: PA System), complete with accessories and compatible for IBMS with open protocol BACnet/Modbus over IP, as per specifications (Honeywell Notifier/Bosch/Siemens/equivalent standard make as desired by SDO). Sub-item 1.1: Single Loop Panel. |
| 180 | Supply, installation, testing and commissioning of intelligent addressable optical smoke detector with LED indication, detector base, dust protection cover and complete mounting accessories. Honeywell Notifier/Bosch/Siemens/equivalent standard make, to be approved by SDO. |
| 181 | Supply, installation, testing and commissioning of intelligent addressable heat detector complete with detector base and mounting accessories. Honeywell Notifier/Bosch/Siemens/equivalent standard make, to be approved by SDO. |
| 182 | Supply, installation, testing and commissioning of addressable Manual Call Point with resettable element, weather-resistant housing and complete accessories. Honeywell Notifier/Bosch/Siemens/equivalent make, to be approved by SDO. |
| 183 | Supply, installation, testing and commissioning of addressable electronic hooter/sounder suitable for 24V DC operation with minimum sound output of 90 dB at 1 metre, complete with mounting accessories. Honeywell Notifier/Bosch/Siemens/equivalent standard make, to be approved by SDO. |
| 184 | Supply, installation, testing and commissioning of LED response indicator for concealed detector locations complete with wiring and accessories. Honeywell Notifier/Bosch/Siemens/equivalent standard make, to be approved by SDO. |
| 185 | Supply, laying, testing and commissioning of 2 Core x 1.5 Sq.mm FRLSH shielded fire survival cable in conduit/tray including termination, ferruling and dressing complete. Havells/Polycab/Anchor/equivalent standard make. |
| 186 | Supply, laying, testing and commissioning of 3 Core x 1.5 Sq.mm FRLSH shielded fire survival cable in conduit/tray including termination, ferruling and dressing complete. Havells/Polycab/Anchor/equivalent standard make. |
| 187 | Supply and laying of heavy-duty ISI-marked PVC conduit of suitable size including bends, couplers, junction boxes, saddles and accessories complete. Anchor/Ravindra/Finolex/equivalent standard make. |
| 188 | Supply, installation, testing and commissioning of sealed maintenance-free batteries suitable for minimum 24-hour standby and 30-minute alarm operation complete with interconnections. |
| 189 | Providing proper earthing of Fire Alarm Control Panel complete with earth electrode, earth wire and accessories as required (GI pipe earthing, 40 mm dia, 3 m long). |
| 190 | Supplying, installation, testing and commissioning of ABC type fire extinguisher, 4 kg capacity, ISI Mark (IS:15683) and duly certified. |
| 191 | Supplying, installation, testing and commissioning of CO2 type fire extinguisher, 4.5 kg capacity, ISI Mark (IS:15683), suitable for B and C class fires including inflammable liquids, gaseous fires such as LPG and acetylene, and electrical fires. |
| 192 | (D) : HVAC WORKS (VRV/VRF SYSTEM, PIPING, CONTROLS, DRAINAGE AND LOUVERS |
| 193 | Supply, Installation,Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building) For Cooling or Heating or Both I. 10 HP to 12 HP (Ground Floor) |
| 194 | 14 HP to 22 HP (Ground Floor) |
| 195 | 10 HP to 12 HP (First Floor) |
| 196 | 14 HP to 22 HP (First Floor) |
| 197 | INDOOR UNIT Indoor units: supply, installation, testing and commissioning of double way VRV/VRF cassette type indoor ceiling mounted unit with filter, fan section, coil, electronic expansion valve, drain pump, grill, supports, vibration isolation and corded remote control, complete as required (make same as outdoor). 1.2 TR (530 CFM) |
| 198 | 2.6 TR TR (740 CFM) |
| 199 | 3.3 TR (1130 CFM) |
| 200 | Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make a. Indoor Units |
| 201 | Outdoor Multi Joint |
| 202 | COPPER REFRIGERANT PIPING COPPER REFRIGERANT PIPING for VRV/VRF system: supply, installation, testing and commissioning including vacuumization and nitrogen testing, with fittings, hanger supports, jointing/brazing, Class-O insulation and all accessories as per specifications. a. 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 203 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 204 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 205 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 206 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 207 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 208 | 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 209 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 210 | Centralized controller supply, installation, testing and commissioning of main intelligent touch screen central controller system, including all accessories, suitable to operate, monitor, on/off and set temperature of all the indoor units individually, complete as required and as Centralized controller |
| 211 | Control & Transmission Wiring Providing & fixing control cum transmission wiring of copper in Heavy Duty conduits PVC conduits between indoor and out door unit. 2 core x 1.5 sqmm |
| 212 | Providing fixing in position UPVC drain pipe or antisyphonge as per IS-4985 (working pressure 6 Kg/ Sqcm) including cutting, jointing with approved solvent cement compound as per IS 14735, wastage etc complete as per manufacturer's specification and as per direction of the Engineer Incharge. 40 mm dia |
| 213 | 32 mm dia |
| 214 | 25 mm dia |
| 215 | Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh birdscreen & volume conrtol dampers as per specifications. Fresh air louvers |
| 216 | Exhaust air louvers(without volume control dampers) |
| 217 | ELECTRICAL SYSTEM: HVAC PANEL's FOR (G+1) |
| 218 | Supplying, installation, testing & commissioning of Totally Type Tested Panels complying IEC 61439-1/2, cubicle type, with internal arc withstand and impact resistance IK10 as per IEC 62262. The panel shall be tested for an internal arc of 50kA for minimum 0.4 seconds. The degree of protection shall be minimum IP 42 for indoor and IP 65 for outdoor use. Suitable for 415V, 3 Phase, 4 Wire, 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of minimum 2 mm thickness for load bearing member and 1.6 mm for non-load bearing member, 3 mm thick for gland plates, including cleaning & finishing complete, having extensible type aluminium bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 50kA for 1 sec., bottom frame shall be 100 mm height as per OEM standard. Fabrication shall be done in transportable sections. Entire panel shall have a common aluminium earth bar of size 32 mm x 6 mm or as specified below at the rear with 2 Nos. earth studs, solid connections from main bus bar to switch gears with required size of Al with Form-4B construction. Bus bars and control wiring with suitable size of PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two halves, including providing following switch gears:- |
| 219 | The bus bars will be copper of purity 99.9% / electrolytic grade E91 aluminium. Panels will be powder coated (60-80 micron as per IS:13871 for indoor and 90-100 micron for outdoor), including one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB. All bus-bar alley and relay compartments shall be provided with fully automatic control thermostat with strip heater. |
| 220 | Also, refer to General Notes and Specifications for Panels/Boards. Contractor to submit manufacturer's total discrimination curves to prove the same, insulation material & corners cover on bus-bars for approval. Feeders should be totally bolted structure with interchangeable feeders. |
| 221 | All live accessible parts shall be shrouded and all equipment shall be finger touch proof. SMC shrouds for bus bar supports shall be used. Padlocking facility shall be provided on all MCCB feeder doors and switch handles shall be lockable in OFF position |
| 222 | Sealing Arrangement: PE foam rubber gasketBus Bar Supports: Non-hygroscopic, non-carbonising, corrosion resistant, SMC supports1 Set of connector (Phase + Neutral) shall be provided in cable alley for all outgoing with interconnection wires between MCB and connector.Minimum air clearances between bus bars shall be as per IEC 61439 Clause 8.2.5; |
| 223 | Panel Power and Control Wiring: all ZHLS PVC insulatedAC voltage circuit: 1.5 sqmm Red, Yellow, Blue & BlackCurrent circuit: 1.5 sqmm Red, Yellow, Blue & BlackAC control circuit: 1.5 sqmm White for Phase & Black for NeutralDC control circuit: 2.5 sqmm GreyPower circuit: Red, Yellow, Blue for Phase & Black for Neutral |
| 224 | Labeling: Computerised laminated aluminium name plate with white letters on blue/black background for each feeder and panel itself. |
| 225 | Note:1) If mentioned fault and automatic transfer switch rating is unavailable, consider nearby upside rating for outgoings.2) A separate compartment for minimum 20% spare space of panel shall be provided for future outgoings and busbars shall be drilled accordingly.3) Total discrimination of system shall be checked and required setting shall be made. If any component is required to change, it will be changed free of cost. The switch-gear & panel manufacturer (jointly) will submit discrimination check report duly checked and signed on company letter head. |
| 226 | GENERAL NOTES FOR ACB's:a. ACB shall be with 4 NO + 4 NC auxiliary contacts.b. Safety shutter.c. Door sealing frame.d. Inbuilt Ethernet port.e. Inbuilt TRIP LED indication.f. ON/OFF/TRIP status on Ethernet.g. Ics = Icu = Icw for 1 sec. for the breakers.h. With built-in micro-processor based releases (digitally upgradable).i. Adjustable over current with time setting.j. Adjustable short circuit with time setting.k. Instantaneous short circuit.l. Adjustable earth fault with time setting.m. Power wiring with one size higher terminals / bus bars for termination of cables as specified.n. There shall be no deration up to 50 degree Celsius.o. ACBs shall be provided with both side terminal adaptors (preferably Hr Vr).p. All the ACBs must be equipped with features like ZSI, thermal memory, last 10 trip histories, current & voltage metering, % loading bar graph, LED fault differentiation, display of per phase energy & Total Harmonics Distortion. |
| 227 | GENERAL NOTES FOR MCCB's:a. MCCB's shall be of TPN (3P with solid neutral link) or 4P as called for in the BOQ.b. Ics = Icu = 100% or more for the breakers.c. All thermal magnetic MCCB's shall have adjustable over current and fixed short circuit if used as outgoing and when used as incomer, short circuit rating shall be adjustable.d. All micro-processor based MCCB's shall have adjustable over current with time setting, adjustable short circuit and adjustable earth fault with indication due to earth fault.e. MCCB's shall be with extended rotary handle with phase spreaders & phase barriers at both sides.f. MCCB's shall have auxiliary contacts for BMS compatibility.g. All MCCBs above 250A shall be microprocessor based. Thermal magnetic MCCBs shall have modular external earth fault protection.h. All the MCCBs in main panel to communicate ON/OFF/TRIP status on Ethernet. |
| 228 | GENERAL NOTES FOR MCB's:a. MCB's shall be of minimum 10kA breaking capacity for 1 sec.b. Use 'B' curve MCB's for lighting & small power circuits, 'C' curve for motor duty i.e. for pumps, AC motors, AHU motors, window and split AC's etc. &'D' curve for UPS DB's i.e. for computers/PC's circuit. Main incomer & outgoing circuit MCB's shall be selected accordingly i.e. type B, C & D as per the nature of the circuit/load.c. Exact MCB rating & category is to be calculated by the electrical contractor based on the final load of the circuit, its nature and fault current. |
| 229 | SDB-1 (HVAC PANEL) TERRACE FLOOR (INDOOR PANEL-IP:42)INCOMER-1 From Existing Sub-Station1 No. 160A 4P MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35kA (Ics = Icu = 100%) up to 415V, manually operated with extended rotary handle with castle lock for door interlock with phase spreader & phase barriers at both sides. MCCB shall conform to IS 13947 (Part 2): 1993 as amended. |
| 230 | Metering, INDICATOR and RELAYsProvide 3 Nos. resin cast CTs, Class-1.0 and MFM True RMS type digital with minimum features of measurements covering A, V, Hz, PF, kW, kVAr, VA, kVA, kVAR, kWH, kVAH, kVARH, MDI, harmonics, run hours, RS-485 port, LCD display with class-0.5 accuracy for all incomer feeders. Refer to Cat. no. Enersol PQMR82.E-Series R, Y, B phase indication lamps with 4 Nos. SP HRC fuses as per fault requirement for each incomer.Provide 3 Nos. indicating lamps for status indication \\"ON\\", \\"OFF\\", \\"Tripped due to earth fault\\" on each incomer and outgoing MCCB. |
| 231 | TVSS AND BUS BARS FOR EACH SECTION250 Amps 4P, 50kA, 500 volts grade busbar chamber of suitable length with aluminium busbars mounted on SMC supports. All interconnections shall be as follows: a) Up to 63A, FRLS PVC insulated copper flexible colour coded wires. b) 64A to 200A copper bus-bars and above aluminium; current density of bus-bars shall not be less than 0.8 A/sq.mm for aluminium and 1.6 A/sq.mm for copper cross sectional area of bus bar.1 No. surge protection device Type 2 (Class C), 4 Mode, MOV type suitable for 8/20 µs surge, voltage protection level Up < 1.8kV, operating temperature -40 deg C to +80 deg C, connected between 3 Nos. phase to neutral and 1 No. neutral to earth with discharge current Imax. ≥ 40kA per mode & In ≥ 20kA per mode. Make & Model: Argos-AG-230-40T2-E or equivalent. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10 sqmm copper wire must be used & length of connecting leads shall not be more than 500 mm for per mode connection with each busbar including all necessary accessories. The SPD shall comply with IEC 61643-11 and be certified by TUV, CE, RoHS, UL94V-0. |
| 232 | OUTGOINGS CONNECTED AS SHOWN IN SLD:3 Nos. 63A 4P MCB3 Nos. 40A 4P MCB |
| 233 | SDB-1 (HVAC PANEL) TERRACE FLOOR (INDOOR PANEL-IP:42) as described above. |
| 234 | 1.1 KV L.T. CABLE SUPPLY, LAYING & TERMINATIONS Supply, laying, jointing, terminating, testing and commissioning of 1100 V grade, armoured, FRLSZH, XLPE, aluminium(AL) / Copper (CU) conductor cables on existing trays/walls/columns/ indoor/ trenches including the cost of supports with suitable clamps, saddles, hooks, bolts etc. and including the cost of proper dressing of cables, markers providing identification tags,earthing of glands armouring etc. complete as per specifications, as required and as below. 3.5C x 95 sq.mm. Al Armoured XLPE cable |
| 235 | 4C x 10 sq.mm. Cu Armoured XLPE cable |
| 236 | 4C x 6 sq.mm. Cu Armoured XLPE cable |
| 237 | MV CABLE JOINTING & END TERMINATION Cable jointing and termination of cable as per item 1.1 -including cost of supplying and fixing, crimping lugs, double compression brass glands, insulation tape etc. complete as per specifications and as required. 3½ X 95 sq. mm (45mm) |
| 238 | 4 X 10 sq. mm (25mm) |
| 239 | 4C x 6 sq.mm. Cu Armoured XLPE cable |
| 240 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 241 | AMC of VRV/VRF system for a period of three (3) years (total outdoor capacity 58 HP) |
| 242 | The above items ate Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender