Tender For Repair / Maintenance Of Mafi Afls At Af Station Nal Under Ge Af Nal
Tender Overview
Project Description
Tender For Repair / Maintenance Of Mafi Afls At Af Station Nal Under Ge Af Nal- 1 M & L For Repair To Lt Panel Board Indoor / Outdoor Type Of Any Capacity Having 1 No Incomer & Out Going MccbS Up To 6 Nos (Max) By Carrying Out The Following Works:-(I) Cleaning Incomer Switches, Bus Bar & Out Going Switches Etc Thoroughly By Using Blower. (Ii) Replacement Of Rusted Bolts & Nuts, Screws, Thimble Etc As Per Existing.(Iii) Replacement Of Indicator Lamps, Volt Meter, Amps Meter, Vss, Ass As Required As Per Existing.(Iv)Replacement Of Incoming / Out Going Switches As Per Existing Make & Model.(V) Replacement Of Control Wiring With Suitable Size As Per Existing Copper Wire(Vi) Making The Locking Arrangement Functional Including Welding If Required (Vii) Replacement Of Mv Danger Board(Viii) Making Proper Connections For Out Going / Incoming Cable By Providing Suitable Thimble As Required. 2 S & F In Repair Mccb, 25Ka, 4 Pole, 250A With Complete All As Specified And Directed 3 S & F In Repair Mccb, 25Ka, 4 Pole, 200A With Complete All As Specified And Directed 4 S & F In Repair Mccb, 16Ka, 4 Pole, 160A With Complete All As Specified And Directed 5 S & F In Repair Mccb, 16Ka, 4 Pole, 100A With Complete All As Specified And Directed 6 S & F In Repair Mccb, 10/16Ka, 4 Pole, 63A With Complete All As Specified And Directed 7 S & F In Repair Change Over Switch 4 Pole 415 Volt 200 Amps With Complete All As Specified And Directed 8 S & F In Repair Digital Volt Meter 0-500 Volt, With Selector Switch Of Size 96X 96 Mm Square Flush Type With Complete All As Specified And Directed. 9 S & F In Repair Digital Ammeter 0-100 Amp Including Ct 100/5 Amps And Selector Switch With Complete All As Specified And Directed . 10 S & F In Repair 4 Pole Power Contactors, Aux. Contacts 1 No And 1 Nc Of Rating 60/63 Amps, For Mafi Panel As Per Existing Make-C & S, Model No. Tc1-D40004 Or Suitable For Existing Panel Complete All As Specified And Directed. 11 S & F In Repair 4 Pole Power Contactors, Aux. Contacts 1 No And 1 Nc Of Rating 40 Amps, For Mafi Panel As Per Existing Make And Model Complete All As Specified And Directed. 12 S & F In Repair 4 Pole Power Contactors, Aux. Contacts 1 No And 1 Nc Of Rating 25 Amps, For Mafi Panel As Per Existing Make And Model Complete All As Specified And Directed. 13 S & F In Repair 4 Pole Power Contactors, Aux. Contacts 1 No And 1 Nc Of Rating 18 Amps, For Mafi Panel As Per Existing Make And Model Complete All As Specified And Directed. 14 S & F In Repair Mcb Tpn/Tp Capacity Of 32 Amps, 10Ka, Wintrip2, C Curve Type, Make-C&S Or Existing Model As Per Site Requirement Complete All As Specified And Directed 15 S & F In Repair Mcb Tpn/Tp Capacity Of 40 Amps, 10Ka, Wintrip2, C Curve Type, Make-C&S Or Existing Model As Per Site Requirement Complete All As Specified And Directed 16 S & F In Repair Mcb Tpn / Tp Capacity Of 63 Amps, 10Ka, Wintrip2, C Curve Type, Make-C&S Or Existing Model As Per Site Requirement Complete All As Specified And Directed 17 S & F In Repair Elcb/Rccb, Spn 32/40 Amps 240Volts, Rated Residential Current-30Ma Complete All As Specified And Directed. 18 Supply And Laying In Repair Single Core 2.5 Sqmm Fire Retardant Low Smoke And Halogen (Frlsh) Pvc Insulated Copper Conductor Cable Multistranded And Sheathed Lt 1100 V Grade Complete All As Specified And Directed 19 Supply And Laying In Repair Single Core 4 Sqmm Fire Retardant Low Smoke And Halogen (Frlsh) Pvc Insulated Copper Conductor Cable Multistranded And Sheathed Lt 1100 V Grade Complete All As Specified And Directed 20 M&L For Disconnecting From The Transformer /Panel Board, Cutting Off Worn Out Aluminium Cable End And Supply, Laying And Testing In Replacement Cable Xlpe Insulated ,Screened, Pvc Bedded,Galvanized Steel Strip Or Wire Armoured,Electric Power Cables (Heavy Duty) 11000 Volts Grade With Stranded Aluminium Conductor Of Size 95 Sq Mm 3 Core Including Taking Out Existing Cable Complete All As Specified And Directed 21 S&F In Replacement Outdoor Type Heat Shrinkable End Joint For Ht Cable With Aluminum Conductor 11000 Volts Grade Size 95 Sqmm, 3 Core Including Jointing, Commissioning And Testing Complete All As Specified & Directed. 22 S&F Straight Through Type Heat Shrinkable Joint For Ht Cable With Aluminum Conductor 11 Kv Grade Size 95 Sqmm, 3 Core Including Jointing, Commissioning And Testing Complete All As Specified & Directed. 23 S&F Straight Through Type Heat Shrinkable Joint For Lt Cable With Aluminum Conductor 1100V Grade Size 50 Sqmm To 95 Sqmm, 3.5/4 Core Including Jointing, Commissioning And Testing Complete All As Specified & Directed. 24 Finding Of Fault To 11 Kv Ug Cable With Suitable Fault Locator Equipment & Pin Point The Fault In The Faulty Cable Including Necessary Excavation And Earth Work For Exposing The Faulty Portion Of The Ug Cable Complete All As Specified And Directed. 25 Excavation In Any Type Of Soil In Trenches Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre In Depth For Cable Trenches For Laying Of Cable / Pipes Etc.And Getting Out In Hard / Dense Soil Including Taking Out Old Bricks Complete All As Specified And Directed By Engineer-In-Charge. 26 Returning, Filling In Trenches Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In-Charge 27 Removing Excavated Materials To A Distance Not Exceeding 50 Metre And Depositing Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Point All As Specified And Directed By Engineer-In-Charge 28 Material And Labour Sand Cushioning Using Dry Clean Sand (Tibba Sand) For Protection Of Underground Cable, Consolidated And Compacted Complete All As Specified And Directed By Engineer-In-Charge 29 Material And Labour For Well Burnt Old Size Sub Class ‘B’ Bricks, Laid Flat, In Trenches For Cable Protection Complete All As Specified And Directed By Engineer-In-Charge 30 Supply Fixing In Repair Indoor Unit Of Split Ac Capacity 1.5Tr Of Existing Make Including Testing Commissioning With Complete All As Specified And Directed
BOQ
| Sl. No. | Item Description |
| 1 | M & L for repair to LT Panel board indoor / outdoor type of any capacity having 1 No Incomer & out going MCCB's up to 6 Nos (Max) by carrying out the following works:-(i) Cleaning incomer switches, bus bar & out going switches etc thoroughly by using blower. (ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing.(iii) Replacement of Indicator lamps, Volt meter, Amps meter, VSS, ASS as required as per existing.(iv)Replacement of Incoming / out going switches as per existing make & model.(v) Replacement of control wiring with suitable size as per existing copper wire(vi) Making the locking arrangement functional including welding if required (vii) Replacement of MV danger board(viii) Making proper connections for out going / incoming cable by providing suitable thimble as required. |
| 2 | S & F in repair MCCB, 25KA, 4 pole, 250A with complete all as specified and directed |
| 3 | S & F in repair MCCB, 25KA, 4 pole, 200A with complete all as specified and directed |
| 4 | S & F in repair MCCB, 16KA, 4 pole, 160A with complete all as specified and directed |
| 5 | S & F in repair MCCB, 16KA, 4 pole, 100A with complete all as specified and directed |
| 6 | S & F in repair MCCB, 10/16KA, 4 pole, 63A with complete all as specified and directed |
| 7 | S & F in repair Change over switch 4 pole 415 Volt 200 Amps with complete all as specified and directed |
| 8 | S & F in repair Digital volt meter 0-500 Volt, with selector switch of size 96X 96 mm Square flush type with complete all as specified and directed. |
| 9 | S & F in repair Digital ammeter 0-100 amp including CT 100/5 amps and selector switch with complete all as specified and directed . |
| 10 | S & F in repair 4 Pole Power Contactors, Aux. Contacts 1 NO and 1 NC of rating 60/63 Amps, for MAFI Panel as per existing make-C & S, Model No. TC1-D40004 or suitable for existing panel complete all as specified and directed. |
| 11 | S & F in repair 4 Pole Power Contactors, Aux. Contacts 1 NO and 1 NC of rating 40 Amps, for MAFI Panel as per existing make and model complete all as specified and directed. |
| 12 | S & F in repair 4 Pole Power Contactors, Aux. Contacts 1 NO and 1 NC of rating 25 Amps, for MAFI Panel as per existing make and model complete all as specified and directed. |
| 13 | S & F in repair 4 Pole Power Contactors, Aux. Contacts 1 NO and 1 NC of rating 18 Amps, for MAFI Panel as per existing make and model complete all as specified and directed. |
| 14 | S & F in repair MCB TPN/TP capacity of 32 Amps, 10KA, wintrip2, C Curve type, Make-C&S or existing model as per site requirement complete all as specified and directed |
| 15 | S & F in repair MCB TPN/TP capacity of 40 Amps, 10KA, wintrip2, C Curve type, Make-C&S or existing model as per site requirement complete all as specified and directed |
| 16 | S & F in repair MCB TPN / TP capacity of 63 Amps, 10KA, wintrip2, C Curve type, Make-C&S or existing model as per site requirement complete all as specified and directed |
| 17 | S & F in repair ELCB/RCCB, SPN 32/40 Amps 240Volts, rated residential current-30mA complete all as specified and directed. |
| 18 | Supply and laying in repair single core 2.5 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade complete all as specified and directed |
| 19 | Supply and laying in repair single core 4 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade complete all as specified and directed |
| 20 | M&L for disconnecting from the transformer /panel board, cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sq mm 3 core including taking out existing cable complete all as specified and directed |
| 21 | S&F in replacement outdoor type heat shrinkable end joint for HT cable with aluminum conductor 11000 volts grade size 95 sqmm, 3 core including jointing, commissioning and testing complete all as specified & directed. |
| 22 | S&F straight through type heat shrinkable joint for HT cable with aluminum conductor 11 KV grade size 95 sqmm, 3 core including jointing, commissioning and testing complete all as specified & directed. |
| 23 | S&F straight through type heat shrinkable joint for LT cable with aluminum conductor 1100V grade size 50 Sqmm to 95 Sqmm, 3.5/4 core including jointing, commissioning and testing complete all as specified & directed. |
| 24 | Finding of fault to 11 KV UG cable with suitable fault locator equipment & pin point the fault in the faulty cable including necessary excavation and earth work for exposing the faulty portion of the UG cable complete all as specified and directed. |
| 25 | Excavation in any type of soil in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches for laying of cable / pipes etc.and getting out in hard / dense soil including taking out old bricks complete all as specified and directed by Engineer-in-charge. |
| 26 | Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed by Engineer-in-charge |
| 27 | Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed by Engineer-in-charge |
| 28 | Material and labour sand cushioning using dry clean sand (Tibba Sand) for protection of underground cable, consolidated and compacted complete all as specified and directed by Engineer-in-charge |
| 29 | Material and labour for well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and directed by Engineer-in-charge |
| 30 | Supply fixing in repair indoor unit of split AC capacity 1.5TR of existing make including testing commissioning with complete all as specified and directed |
| 31 | Supply fixing in repair complete outdoor unit of split AC, capacity 1.5TR including compressor, condensor etc of existing make including testing, commissioning with complete all as specified and directed Please Enable Macros to View BoQ information |
| 32 | Supply fixing in repair complete outdoor unit of split AC, capacity 1.5TR including compressor, condensor etc of existing make including testing, commissioning with complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender