Tender For Special Repair To Building No T-180, 181 And 199 At Cbs Bhalra Under Age (I) Bhalra
Tender Value
20.53 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
16 days left
EMD
41100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Doda → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No T-180, 181 And 199 At Cbs Bhalra Under Age (I) Bhalra
BOQ
| Sl. No. | Item Description |
| 1 | BUILDING WORK INCLUDING INTERNAL WATER SUPPLY |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and directed. |
| 3 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 Sqm each and not exc 4 Sqm each complete all as specified and directed. |
| 4 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed. |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 6 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including or similar pattern roof coverings complete all as specified and directed. |
| 7 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 8 | Taking up or down GI tubing and connection 15 mm bore, including cleaning for refixing, complete all as specified and directed. |
| 9 | All as per item Srl No-1.07 here-in-before but for 20 mm bore complete all as specified and directed. |
| 10 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 11 | Excavating in post holes each not exc 0.5 Cum, getting out, in any type of soil, ramming earth filling or borken rubble mixed with earth around in layers not exc 25 cm watering and removing surfaces soil to distance not exc 50 m and making good surfaces complete all as specified and directed. |
| 12 | Plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in sub-base of floor, 100mm thick etc., complete all as specified and directed. |
| 13 | Plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed. |
| 14 | PCC 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in plinth protection (75mm thick) finished over and smooth without using extra cement etc., complete all as specified and directed. |
| 15 | Machine kota stone slab flooring 20mm to 25mm thick over 20 mm thick screed bed in cement mortar 1:3 with cement slurry @ 3kg/sqm jointed and pointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 16 | Glazed, coloured, ceramic, tiles of size (350mm x 250mm x 7mm/ 300mmx450mmx7mm thick), on vertical surfaces, such as skirting, dadoes, etc set and jointed in neat cement slurry and pointed in coloured cement to match with the surface over and including 15mm thick screed in CM 1:4 complete all as specified and directed. |
| 17 | 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with providing 15mm thick screed bed in cement mortar 1:4, complete all as specified and as directed. |
| 18 | Brick work with sub class “B” bricks straight or curved on plan exc 6m mean radius built in CM 1:6 using old size brick, complete all as specified and directed. |
| 19 | Brickwork with sub class 'B' bricks, strainght or curved on plan to any radius in half brick thick walls build in cement mortar 1:4 complete all as specified and directed. |
| 20 | Rotational moulded polyethylene water storage tank 1000 ltr capacity three layer white in colour hoisted and fixed in position including PVC float valve 20 mm bore and including dismantling of existing water storage tank, complete all as specified and directed. |
| 21 | Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. |
| 22 | Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. |
| 23 | Pressed steel frames of size 165mm x 60mm x 1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 24 | 30mm thick flush shutters solid core construction with block board core and two face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed. |
| 25 | 35mm thick 2nd class hard wood glazed and skelton shutter open rebated and prepared to receive glass ,gauge etc (with sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8 clause 8.24(a), supplied and fitted to chowkats, complete all as specified and directed. |
| 26 | All as per item srl No-1.24 here-in-before but for 30 mm thick complete all as specified and directed. |
| 27 | 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 28 | Stainless steel wire cloth of 0.36 mm dia wire and average width of aperature 1.40 mm and fixed with stainless steel staples fixing in doors and windows, complete all as specified and directed. |
| 29 | 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 30 | All as per srl item No-1.28 here-in-beore but for 150mm long complete all as specified and directed. |
| 31 | 150mm extruded aluminium alloy handles, cast type, anodized complete all as specified and directed. |
| 32 | 300mm long aluminium alloy, anodized sliding door bolt with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and directed. |
| 33 | 15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs etc complete all as specified and directed. |
| 34 | All as per srl item No-1.32 here-in-before but for 20mm bore complete all as specified and directed. |
| 35 | 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 36 | All as per srl item No-1.34 here-in-before but for 20mm bore complete all as specified and directed. |
| 37 | 15mm bore fancy type bib tap brass CP (Long body) with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs complete all as specified and as directed. |
| 38 | Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 grade E-165, complete all as specified and directed. |
| 39 | TMT bars 10mm dia and over cut to lengths bent to shape required including cranking bending and spirally hoping for columns hooking ends and binding with MS wire annealed not less then 0.90mm dia, complete all as specified and directed. |
| 40 | RCC 1:1.5:3 type A-1 using 20mm graded crushed stone aggreagates as in slab supported on walls, beam and column landing, roof, balcony, canopy, deck slabs, shelves and similar work for water retaining structure complete all as specified and directed. |
| 41 | Formwork to soffits of rough finished flat suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (Horizontal or sloping) complete all as specified. |
| 42 | Plain Cement Concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneelers, apex stones etc water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed. |
| 43 | Steel work in trusses, purlins, posts and the like using tubular/square/rectangular hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161-2014 / IS.4923-1997 grade St-240 complete all as specified and directed. |
| 44 | Mil steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 complete all as specified and directed. |
| 45 | Machine made mild steel screw bolts of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 10 cm but not exceeding 15 cm complete all as specified and directed. |
| 46 | Soap dish of cast copper alloy, chromium plated (CP), fixed as in repair complete all as specified and directed. |
| 47 | Grating doom 125mm dia with waste hole of PTMT (Minimum weight 40gms), fixed in repairs complete all as specified and directed. |
| 48 | Taking down cement plaster of any description on brick or stone walls, ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 49 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed. |
| 50 | 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair with using of WPC complete all as specified. Note: WPC shall be measured and paid separately. |
| 51 | Supply only integral liquid water proofing compound complete all as specified and directed. |
| 52 | Preparing new plastered surfaces of walls and applying acrylic smooth exterior paint of required shade (two or more coat applied @ 1.67ltr/10Sqm over and including priming coat of exterior primer applied @ 2.2 Kg/10 Sqm), complete all as specified and directed. |
| 53 | Writing letters or figures (block, roman, italic or indian) not exc 30cm high with spots, commas, short lines, dashes, hyphens, bracket, etc for mention of bldg No complete all as specified and directed. |
| 54 | 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including dismantling, fixed in repairs complete all as specifed and directed. |
| 55 | 110mm bore PVC (SWR) bends any radius, complete all as specified and directed. |
| 56 | 110mm bore PVC (SWR) pipe reducer complete all as specified and directed. |
| 57 | preparation of old distempered surface of walls including brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, stopping of distempered surface and applying two coat of oil bound distemper on walls of approved shade complete all as specified and directed. |
| 58 | Preparation of old decorated plastered or un plastered surfaces including brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots, removal of vegetation and applying two coat of cement base paint of approved shade complete all as specified and directed. |
| 59 | Preparing of new steel surfaces of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 60 | Preparation of new or previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 61 | Preparation on new steel surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 62 | Ball valves 15mm high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms /20mm-210gms/ 25mm-455gms/ 40mm- 690 gms), fixed in repairs complete all as specified and directed. |
| 63 | INTERNAL ELECTRIC SUPPLY |
| 64 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets, MCBs, DB etc., to be measured separately), removing materials to store for kepping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc., complete all as specified and directed. |
| 65 | Point wiring with and including 1.5 Sqmm (nominal area) PVC insulated multistranded copper conductor FRLS in and including PVC casing and caping not less then 20 mm dia with all accessories as required at site incl with its fittings and fixture such as ties, bends, elbows and juction boxes etc with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal, one light point controlled by one way switch all as specified and directed. |
| 66 | All as per srl item No-2.02 here-in-before but one 3/5 pin socket otutlet, 5 amps, on same board, with cables 1.5 Sqmm size with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing complete all as specified and directed. |
| 67 | All as per srl item No-2.02 here-in-before but one 3/5 pin socket outlet, 5 amps, on independent board, with cables 1.5 Sqmm size with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing complete all as specified and directed. |
| 68 | All as per srl item No-2.02 here-in-before but One 5 pin socket out let, 15 Amps, on independent board, with cables 4 Sqmm size with 2.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing complete all as specified and directed. |
| 69 | LED tube light fittings 1 x 20 watts with LED tube complete, fixing on recess/surfaces etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible cable of 0.75 Sqmm 3 core copper conductor from ceiling rose to light fittings complete all as specified and as directed. |
| 70 | LED light fitting 1 x 9W/ 1 x 10 Watt bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size 230V, 50 HZ complete all as specified and directed. |
| 71 | Switch piano type 5 Amp flush button single pole one way, fixed in repairs complete all as specified and directed. |
| 72 | Socket 2 in 1, 5 Pin, 5 Amp, fixed in repairs complete all as specified and directed. |
| 73 | Switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal, fixed in repairs complete all as specified and directed. |
| 74 | Switch socket combination 5 in 1, 3 pin, 5 and 15 amp flush type universal, fixed in repairs complete all as specified and directed. |
| 75 | Ceiling rose 3 terminal complete PVC/Polycarbonate insulated body, fixed in repairs complete all as specified and directed. |
| 76 | MCB 6Amps to 32 Amps SP 'C' series 240 V, 50 Hz, breaking capacity 10 KA suitable for lighting and other domestic loads, fixed in repairs complete all as specified and directed. |
| 77 | MCB 32 Amps SPN 'C' series 240 V, 50 Hz, breaking capacity 10 KA, fixed in repairs complete all as specified and directed. |
| 78 | Sheet metal enclosure for DBs double door when MCBs to be used single pole and neutral with 200 Amps rated bus bar 240 Volts 8 way, fixed in repairs complete all as specified and directed. |
| 79 | 1100 Volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire one twin core 16 Sqmm solid conductor complete all as specified and directed. |
| 80 | Exhaust fan, steel body AC single Phase 230V of size 380mm sweep with, blades, and frame & louvers, making connections with three core PVC insulated and sheathed flexible copper conductor cable from exhaust rose including taking down of old unserviceable exhaust fans from site and deposited in MES store yard, complete all as specified and directed. |
| 81 | Earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300mm x 300mm x 300mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, Jalli pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete, all excavation and earth work and connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete all as specified and directed. |
| 82 | AREA DRAINAGE |
| 83 | PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundations and walls complete all as specified and directed. |
| 84 | Plain cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in surface channels and drains complete all as specified and directed. |
| 85 | Use and waste of formwork to faces of walls, abutments, parapets and stair case railing including attached pillasters, butteresses for fair finish surfaces of concrete all as specified and directed. |
| 86 | RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) precast drain cover slabs including necessary form work set in CM 1:4. Exposed surface of concrete shall be finished even and smooth without using extra cement complete all as specified and directed.Note: Reinforcement shall be measured and paid seperately. |
| 87 | 110mm bore PVC (SWR) pipe single socketed in any length as in weep holes complete all as specified and as directed. |
| 88 | FENCING |
| 89 | Demolition of stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 90 | Walling of random rubble stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:6, brought up to courses, complete all as specified and directed. |
| 91 | Precast cement concrete, 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in bond stones set in cement mortar 1:6 and finishing exposed surfaces including necessary form work, complete all as specified and directed. |
| 92 | Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified and directed. |
| 93 | Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete, all as specified and as directed. Please Enable Macros to View BoQ information |
| 94 | Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete, all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender