Defence Statutory Bodies & Commissions/Committees Closing in 25 days TDR #58205245

Tender For Special Repair To Building No Np-37 (Grc Main Office) At Grc K Tee.

Issued by Statutory Bodies & Commissions/Committees · Nagpur, Maharashtra
Tender Value
1.45 Crore
Estimated cost
Bid Submission
21 Nov 2026
25 days left
EMD
2.20 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Building No Np-37 (Grc Main Office) At Grc K Tee.

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG NO NP-37 (GRC MAIN OFFICE) AT GRC K TEE.
Sl. No. Item Description
1Dismantling floor hearth or wall tiling including cement mortar bedding and disposal of rubbish outside of MD land complete all as directed.
2M&L light shade vitrified ceramic tiles 10mm thick (square/rectangular ) polished area each tiles n.exc 0.36 Sqm in floor/wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed of cement mortar (1:6) complete.
3M & L for coloured non skid mat finished ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding. 0.38 sqm, in floors/wall etc. set and jointed in neat cement slurry and pointed with white or coloured cement to match over and including 15 mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed.
4All as item No 3 above but as in skirting/dado etc with 10mm backing in cement mortar 1:4 complete.
5M & L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed of cement mortar (1:6) etc complete all as specified and as directed.
6M&L coloured/printed glazed ceramic tiles 300x600x6 to 7mm thick, or 600x1200x7 to 8 mm thick in floors/walls skirting/dado etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles including rendering 10mm thick in CM 1:4 complete all as specified and directed.
7Demolition of cement concrete in any description and in any position not otherwise specifically provided for and disposal of rubbish outside of MD land complete all as specified and directed.
8M & L PCC 1:4:8 , type D2, (40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed.
9M&L for providing RCC 1:1 1/2:3 type A-1 (nominal mix) as in footing, foundation, beams, plinth beams,lintel beams base for columns and mass concrete etc complete all as specified and directed.
10S&F milt steel TMT bars 10 mm dia & over cut to length, bent to shape required, including cranking bending and binding with mild steel (anneal) wire not less than 0.90mm dia complete, all as specified and directed.
11Demolition stone slabs and tiles of any description or thickness in floors, aprons etc and disposal of rubbish outside of MD land complete all as specified and directed.
12S&F pre-polished granite 20mm thick fixed on platform/shelves floor/dado over 20mm thick screed bed in cement mortar 1:6 including necessary moulding etc complete all as directed.
13M & L for rendering 15mm thick in CM 1:6 on brick work or concrete surfaces including finished fair and even complete all as specified and directed.
14M & L for rendering 5mm thick CM 1:3 on brick or concrete surfaces of ceiling /chajja's finished even & smooth without using extra cement complete all as specified and directed for taking down plaster portion.
15M & L Preparing New plaster surfaces of wall applying two coats of oil bound distemper over a coat of cement Primer/chalk whiting complete all as specified and directed.
16S & F in repair white Vitreous china wash down water closet pan (pedestal pattern) including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including flush pipe and fixing bolts (excluding flushing cistern) etc complete all as specified and directed .
17S&F in repair PVC valve less symphonic action type flushing cistern 10ltr capacity low level, white/coloured with inlet ball valve float and handle including bracket(incl. Taking down old cistern ) and fixing of PVC flush pipe 32 mm dia and PVC connection pipes complete all as specified and directed.
18Supply & fixed in repairs Wash Hand basin table top ( flat back or angle back )of size 550 X 400 MM white including , waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed pipe, chain and plug, porcelain stopper including for & pinning in ends of brackets including supply & fixing of waste pipe complete all as specified and directed.
19S&F in repair PVC Waste Pipe 32/40 mm dia complete all as specified & directed
20S&F in repair 600 x 1200mm bevelled edge mirror 5.5mm to 6mm thick selected quality glass flaw less, firmly mounted S/S stud/plug with chromium plated brass screw and cup washer complete all as specified and directed.
21S&F as in repair corner sheet glass shelf assemble consisting of 5.5mm thick sheet glass shelf with chromium plated bracket guard and railing complete all as specified and directed.
22S&F in repair tubular towel rail, 20mm dia, D type, 60cm long between flanges chromium plated.
23S & F in repairs bib tap 15 mm dia cast copper alloy chromium plated fancy type with crutch or butter fly handle screwed for iron pipe or for brass ferrule complete all as specified
24S&F pillar cock swan neck 15 mm bore brass CP screwed for iron pipe including taking down existing one complete all as specified and directed.
25S&F in repair15mm Stop valves/angle cock, cast copper alloy, screwed down , high pressure, with crutch or butterfly handles , screwed both ends for iron pipe or for unions and fixed fancy type chromium plated complete all as specified and directed.
26S&F in repair two way angle /bib cock , cast copper alloy, screwed down , high pressure, with crutch or butterfly handles , screwed both ends for iron pipe or for unions and fixed fancy type chromium plated complete all as specified and directed.
27S&f in repair Vitreous China Urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe)
28S&F in repairs Urinal spreader of brass chromium plated for fixing with 15mm dia pipe complete all as specified and directed
29S&F in repair toilet paper holder complete all as specified and directed.
30S & F in repair health faucet of 15 mm bore brass chromium plated including PVC pipe to connection GI tubing 15 mm bore all complete all as specified and directed.
31S&F grating doom with/without waste hole 125mm dia of chromium plated complete all as specified and directed.
32S&F in repairs Waste fittings, 32/40 mm brass, chromium plated for sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
33S&F in repairs Soap dish, CP 125mm size fixed to plugs with chromium plated brass screws complete all as specified and directed.
34S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed .
35S&F in repairs 32mm bore of pipe low density polyethylene pipe (LDPE) including necessary elbow, tee, socket, etc of pressure rating 6kg/cm fixed complete all as specified and directed.
36S&F in repairs flush pipe of polythene of low or high density 32 mm PVC for low level flushing cistern complete all as specified and directed.
37S&F in repairs Plastic water closet seat, back, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
38Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or offering credit as per schedule of credit all as directed.
39All as per item No. 38 above, but 20mm bore
40S&F GI tubing 15 mm bore medium grade with all fittings and fixed to wall with clamps including taking up or down existing GI tubing and cutting chases for concealed and making good cutting not exec 10 cm girth in cement mortar 1:3 complete all as specified and as directed.
41S&F GI tubing 20 mm bore medium grade with all fittings and fixed to wall with clamps including taking up or down existing GI tubing complete all as specified and as directed.
42S&F in repairs PVC(SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall with necessary clamps complete all as specified and directed.
43S&F in repairs PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to wall with necessary clamps complete all as specified and directed.
44S&F in repair PVC (SWR) Bends any radius for 110 mm bore complete all as specified and directed
45-ditto- but for 75 mm bore complete all as specified and directed
46S&F in repair PVC (SWR) branch piece single Y equal or unequal for 110 mm bore complete all as specified and directed
47-ditto- but for 75 mm bore complete all as specified and directed
48S&F in repair PVC (SWR) branch piece, double Y equal or unequal for 110 dia bore complete all as specified and directed
49-ditto- but for 75 mm bore complete all as specified and directed
50S&F in repair PVC (SWR) vent cowl 75mm bore complete all as specified and directed
51Taking down door / window frame with shutter (without taking off shutter from the frame) area not exc 1.5 sqm complete all as specified and directed.
52S&F solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges will be painted to match with the prelam sheet reinforced with MS square tube in opening incl necessary fixing arrangements as per specification and drawing complete all as specified and directed
53S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet for top rail, lock rail and bottom rail on either side as gap insert for top rails, bottom rail, panelling of both side prelam PVC sheet to be fitting in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement in the frame at site as per specification and drawing
54S & F For WPC door frame browm 100 MM X 65 MM for WPC doors complete all as specified and directed by Engr in Charge.
55Supply and fix WPC Doors water proof materials 30 mm thick both side laminated 650 density hard for all wether resistance complete all as specified and directed by Engr in Charge.
56S&F 150mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt
57S&F 100mm size mild steel butt hinges medium weight, cold rolled
58S&F 125mm size mild steel pressed handles, oval type, stove enameled black
59S&F 250 mm Aluminium sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate
60Supply and fix colour powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
61Supply and fix colour powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). Hinges type B-21100mm long (2 no.) suitable handle (1no.) complete all as specified and as directed.
62Dismantling water tank of capacity exc 500 ltr & not exc 1000 ltrs and removing to store of any description complete all as specified and directed
63S & F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000ltr hoisted and fixed in position complete all as specified and directed
64S&F in repair 20mm bore gun matel globe or gate valve with iron wheel, screwed both ends for iron pipes complete all as specified
65S&F in repair 20mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule
66M&L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over coat of primer and 2-3mm thick wall care putty complete all as specified and directed. Note -Applied by Roller Only, Brush Not Allowd For Painting ( Rate also includes preparing surface and scarping walls and making surface good
67Dismantling of Plain or corrugated steel sheeting sheet (corrugated, semi-corrugated etc) sheets in roof coverings complete all as specified and directed.
68S& F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
69S& F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
70Dismantling of ceiling boards (fibre, pulp, insulation etc) or insulation boards/blankets any thickness, including cover fillets/GI SNAP GRID/POP ceiling etc all as specified and as directed.
71M&L for non-asbestos designer fibre cement building boards of size 595x595x6mm Grid in black/ decorative colour fixed or laid/inserted to GI frame work with screws/clips as in ceiling laid flat or sloping as directed. (Note : GI frame work will be measured and paid for separately)
72S&F GI framework for seamless ceiling of size 600mm x 600mm comprising of hot deep galvanized powder coated perimeter angle 0.43mm thick of size 24x24mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre, main runner Tee section 0.4mm thick with height 38mm and cross approx 1200mm centre to centre with GI cleat and steel expansion fasteners, including drilling holes for 4-6mm dia GI wire suspender and clips etc complete as per manufacturer's recommendations complete all as directed (i) Ceiling boards shall be measured separately. (ii) The grid system shall be as per specification of make as specified and directed.
73Excavation in Post holes each , not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm , watering, and removing surplus soil to a dist n. exc 50 m and making good surface.in Soft/Disintegrated rock.
74M&L, PCC (1:3:6) graded stone aggregate as in foundation,using 40 mm graded stone aggregates filling and mass concrete all as specified and directed
75S & F Rolled Mild Steel sections confirming to Fe 290 Gde E-165 as in fencing pole or water staging other similar work all as directed by Engineer-in-Charge
76M&L preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified.
77Roughening surfaces of old concrete floor/terrace by picking incl. taking down existing detoriated / decayed tar felt or any treatment including loose surface, scraping with scraper, chiselling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials debris to a distance as directed by Engr-in-Charge.
78M&L 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof padding finish surface even and smooth without using extra cement including mixed with water proofing compound @ 3% by wt of cement incl demolition of PCC in any description complete all as specified and directed (Note : Water proofing compound will be measured and paid separately)
79M&L for rendering 10 mm thick in cm 1:4 in horizontal / vertical surface of brick or concrete surfaces using water proofing liquid compound and finishing surfaces even & fair without using extra cement. complete all as specified and directed. Note: water proofing liquid will be measured and paid separately.
80Material & labour for provision of water proofing treatment by using APP torch on mineral/plain finished membrane over roof and vertical surfaces including preparation of surfaces and applying oil based bituminous primer coat @ 0.30 ltr per sq m on clean and dry surface and then providing APP membrane having non woven. polyester film reinforcement with 3 mm thick and weight not less than 3 .00 kg/sq m and finished on top with mineral/slate finished torch on system laid with 100 mm & 150 mm over lap on side & end laps respectably complete all as per manufacturers compound complete all as specified and directed.
81M&L for brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete incl demolition of brick work built in cement mortar all as specified
82S&F Mild steel work in Tubular/square hollow trusses, purlins, rafter and tubular posts including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to IS 1161-1979 Grade St-240 with one shop coat of zinc chromate primer paint etc complete all as specified and directed.
83M & L for 5mm thick Solid plain colour PVCsheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site including taking down old panelling all as specified and directed by Engr in Charge.
84Providing and fixing factory made uPVC white colour Sliding window Three track of area not exc 2 Sqmmade of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connectedaccessories. Net Opening will be measured lor payment purpose.)
85Supply and fix framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed.
86Material and labour for rendering 15 mm thick on brick or concrete surfaces in CM 1:4 using water proofing liquid compound as per manufacturer instructions, and finished fair and even complete all specified and directed.Note: WPC shall be measured and paid separately.
87Supply only liquid water proofing compound complete all as specified and directed.
88Material and Labour for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including preparation of surfaces complete all as specified and directedNote:- Painting to be executed by mechanical means through authorized applicator of approved make.
89M&L post construction anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same
90M & L for 75 mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and rough to receive tile etc incl demolition of cement conc 75 mm thick as in plinth complete all as specified and directed .
91Dismantling boarding, any description, fixed in any position with screw, complete all as specified and directed.
92Supply and fixing 18 mm thick UV High gloss MDF board duly edge banded with 0.8 mm thick PVC taping fitting of shutters shall be done with auto closing hydraulic hinges and modular handles, design and colour as approved by GE suitable for kitchen cabinet etc complete all as specified and directed Note : - hinges, handles and locked shall be measured and paid separately under relevant items here-in before.
93Demolitions of cement concrete any description and in any position not otherwise specifically provided for complete all as specified and directed.
94Material and labour for 100 mm thick plain cement concrete type B1, (1:2:4) (using 20mm graded stone aggregate) as in floor/ hard standing, etc finished surface even and smooth without using extra cement, complete all as specified and directed.
95Material and labour for pre-polished chequered tiles rubber pressed glossy finish (any colour) 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 20mm screed bedding in cement mortar (1:4) complete all as specified and directed.
96M & L sand cousining 25mm thick filling under interlocking paver block ,floorings/pavement spread and levelled in layers n.exc 15cm thick complete including watering and consolidation complete all as specified and as directed.
97M & L of Machine pressed precast concrete interlocking paver block colour glossy finished rubber pressed any shape and size confirming to IS 15658-2006 of 80 mm thickness M-35 Grade with Grey cement and pigment complete all as specified and as directed.
98M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cills, steps, seismic and other similar bands, plinth courses, lacing courses parapets and railing upto 60cm height, copings, kneelers, bed plates, hold fasts block, filling on pressed steel door/ frame etc complete all as specified and as directed.
99Taking down point wiring with aluminium conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/colour washing/ distempering to match with existing wall/floor/ceiling finishes, complete all as specified and directed.
100Taking down sheet metal enclosure, DB & MCBs main switch etc and making good distrubed sufaces to match with exisiting surfaces, complete all as specified and directed.
101Taking down sub main wiring of any size/ capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces, complete all as specified and directed.
102Material and labour for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm modular boxes sunk on wall for mounting of any type modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, complete all as specifed and directed.Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
103Ditto all as per item no 102 but one light point controlled by two, two way switch complete all as specified and directed.
104Ditto all as per item Sl No 102 above but One ceiling/exhaust fan point controlled by oneway switch and regulator, complete all as specified and directed.
105Ditto all as per item Sl No 102 above but One 3 pin 6 amp socket outlet point on the same board with other switches, complete all as specified and directed.
106Ditto all as per item Sl No 102 above but One 3 pin 6 amps socket out let point on independent board, with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm complete all as specified and directed.
107Ditto all as per item Sl No 102 above but One bell/buzzer point controlled by one bell push, complete all as specified and directed.
108Ditto all as per item Sl No 102 above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point, complete all as specified and directed.
109Material and labour for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the size 2x4.0 Sqmm with earth wire of 1x4.0 Sqmm, complete all as specified and directed.PVC Conduit.Note:- one run of 3 x 4.0 sqmm and conduit will be measured as one unit.
110Material and labour for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the size 2x1.5 Sqmm with earth wire of 1x1.5 Sqmm, complete all as specified and directed.PVC Conduit.Note:- one run of 3 x 1.5 sqmm and conduit will be measured as one unit.
111Material and labour for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the size 2x6.0 Sqmm with earth wire of 1x6.0 Sqmm, complete all as specified and directed.PVC Conduit.Note:- one run of 3 x 6.0 sqmm and conduit will be measured as one unit.
112Material and labour for sub main wiring with five single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 25 mm medium grade concealed in wall of the size 4x6.0 Sqmm with earth wire of 1x6.0 Sqmm, complete all as specified and directed.PVC Conduit.Note:- one run of 5 x 6.0 sqmm and conduit will be measured as one unit.
113Material and labour for sub main wiring with five single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 25 mm medium grade concealed in wall of the size 4x10.0 Sqmm with earth wire of 1x10.0 Sqmm, complete all as specified and directed.PVC Conduit.Note:- one run of 5 x 10.0 sqmm and conduit will be measured as one unit.
114Supply and fixing for switch modular type single pole one way 6 amp 1 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed.
115S & F switch modular 2 way single pole 6 Amp 1 module complete all as specified and directed.
116Supply and fixing for socket modular type single pole one way 6 amp 2 module 3 pin 250 volts AC suitable for modular switchboxes, complete all as specified and directed.
117Supply and fixing for switch modular type single pole one way 6/16 amp 3 pin 250 volts AC suitable for modular switch boxes, complete all as specified and directed.
118Supply and fixing for socket modular type single pole one way 6/16 amp 2/3 pin 2 module, 250 volts AC suitable for modular switch boxes, complete all as specified and directed
119Supply and fixing ceiling rose, surface type, three terminals 6 amps, complete all as specified and directed.
120Supply and fixing Electric Bell Ding dong AC 230 volts, single phase, complete all as specified and directed.
121Supply and fixing bell push switch modular type single pole one way 6 amp 240 volts, complete all as specified and directed.
122Supply and fixing 0-5 step -2 module modular type electronic regulators for ceiling fan 1200/1400 mm sweep, 240 volts, 120 watts single pole complete all as specified and directed.
123Supply & Fix modular motor starter 25A , 2 module for AC complete all as specified and directed.
124Supplying and fixing 20 Watt LED Tube light fittings complete with PVC body including tube rod, driver with not less than 2000 Lumen O/P and I/p rated voltage 220 to 240 V , 50 Hz, CCT 6500K, THD<10% connecting with 3 core 1 sqmm copper conductor cable complete all as specified and directed.
125Supply and fix lamp holder insulated body with back plate for angle/ batten fitting complete all as specified and directed.
126Supply and fixing LED light fitting 10W bulk head luminaries made of PVC housing with lamp holders etc complete with all accessories and including connecting upto with twin core twisted flexible cable suitable size of 220 to 240V, 50Hz, THD<10%, lumen 100 lm /watt, 6500 K complete all as specified and directed.
127Supplying and fixing 10 Watt LED Tube light fittings complete with pvc body including tube rod, driver with not less than 1000 Lumen O/P and I/p rated voltage 220 to 240 V , 50 Hz, CCT 6500K, THD<10% connecting with 3 core 1 sqmm copper conductor cable complete all as specified and directed.
128Supply and fix building security light LED 35 W with Lumen O/P 3500 with driver with rated voltage 220 to 240 V, 50Hz, IP 66 including mounting GI (made out of light grade GI pipe of suitable dia) 0.8 m bent two shape including clamps nut bolts etc. complete all as specified and directed.
129Supply and fix Energy efficient recess/surface mounted 2'X2' grid Ceiling LED fitting 36/40 W rated voltage 240 V, 50Hz white /warm white combination with profiled and flat diffuse complete all as directed by the Engineer-in-Charge.
130S & F Solar street light fitting 30 W alongwith 18AH Battery with high efficiency mono crystalline solar PV module, battery with inbuilt BMS technology, MPPT charge controller, aluminium extruded body IP65 with serviceable battery compartment, high efficacy LED >150LPW with fixed & PIR based dimming provided for optimizing battery autonomy. Hybrid charger ready to install on buildings including mounting facilities as required all as specified and as directed by Engineer-in-Charge.
131Supply and Fix ceiling fan 1200 mm sweep complete with 3 blades controllable by regulator min 225 CFM air delivery BEE 5 star rated copper wound Brushless Direct Current(BLDC) motor including all accessories like down rod, electronic circuit board
132Supply and fixing Exhaust fan metallic body 300 mm sweep, 1400 RPM single phase, 3 blades 230 Volts, 50Hz, with nut and bolts, washers etc., and connecting up with twin core twisted flexible copper conductor cable of suitable size from fitting to ceiling rose, and making holes for exhaust fan in wall complete all as specified and directed.Note :- Wire mesh shall be fixed outside the opening to prevent insect/flies at no extra cost
133Supply and fixing Wall mounted Fan 400mm sweep including all fixing arrangement as required at site all as specified and as directed.
134S & F sheet metal enclosure vertical MCCB DB TPN 6 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete all as specified
135Supply and fix sheet metal enclosure Triple pole & neutral for 240 volts 6 way with 200 Amp rated bus bar flush /surface mounting, double door, complete all as specified and directed.
136Supply and fix sheet metal enclosure single pole & neutral for 240 volts 4/6 way with 200 Amp rated bus bar flush /surface mounting, double door, complete all as specified and directed.
137Supply and fix sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting, double door, complete all as specified and directed.
138Supply and fix sheet metal enclosure single pole & neutral for 240 volts 12 way with 200 Amp rated bus bar flush /surface mounting, double door, complete all as specified and directed.
139S & F MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA complete all as specified and as directed.
140Supply and fix MCB TPN pole & neutral 240 volt 63 amps 10 KA, \\"C\\" curve complete all as specified and directed.
141Supply and fix MCB TP 240 volt 63 amps 10 KA, \\"C\\" curve complete all as specified and directed.
142Supply and fix MCB single pole & neutral 240 volt 32-63 amps 10 KA, \\"C\\" curve complete all as specified and directed.
143Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA, \\"C\\" curve complete all as specified and directed.
144Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 15mm bore in wall/floor/and GI Pipe 20 mm bore medium grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes for srl Item No. 3.06 & 3.07.(a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made. (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (c) If the testing result of earthing work is not found satisfactory then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative.
145Supply, fixing & testing or on walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 120 Sqmm 3.5 core including testing after laid and jointed all as specified and as directed Note:- Excavation and earth work, cable protection shall be measured and paid separetely.
146All as per item No. 145 but cable size 95 Sqmm 3.5 core all as specified and as directed.
147Excavation in trenches for laying of cable trench, pole and stay foundation in any type of soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out.
148Returning filling in,including spreading,leveling watering and well ramming in layers not exceeding 25 cms thick. Complete all as specified and directed
149Removing excavated materials to a distance not exceeding 50 Mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point.
150M&L for drilling suitable dia horizontal bore holes for insertion/ laying of upto 110mm bore HDPE pipe/GI pipe of any description below/under existing road surfaces/apron /floors etc with using mechanical and / or manual devices as required at site including making good the disturbed surfaces to match with the existing strata after laying pipes complete all as specified and directed. (NOTE : (i) Pipes shall be laid minimum 60 cm below/under existing road surfaces/ apron /floors etc). (ii) Equipment, tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor without any extra cost to the Govt.
151Supplying and laying of 90 mm DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
152Supply, installation, test and commissioning of LT Distribution Panel (CPRI Approved) for Bldg No. 208 cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired, outdoor cubicle type, vermin proof, dust proof, fixed on 50x50x5mm MS angle iron frame fixed 600mm above ground level and 400mm below the ground level grouted in and including PCC 1:3:6 type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm thick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy RAL 7032 siemen grey colour after seven tank phosphating treatment from inside and outside with locking arrangement, front and back opening type and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, all control cables shall be of 2.5 Sqmm copper multi stranded conductors and shall be properly bunched with suitable size binding materials , ferruled for proper identification of colour codes and crimped with adequate size of lugs also to accommodate, fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and consisting of the following items, including taking down the old unserviceable LT Panel/feeder pillar of any size/ any type, all as specified and as directed. Please Enable Macros to View BoQ information
153Supply, installation, test and commissioning of LT Distribution Panel (CPRI Approved) for Bldg No. 208 cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired, outdoor cubicle type, vermin proof, dust proof, fixed on 50x50x5mm MS angle iron frame fixed 600mm above ground level and 400mm below the ground level grouted in and including PCC 1:3:6 type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm thick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy RAL 7032 siemen grey colour after seven tank phosphating treatment from inside and outside with locking arrangement, front and back opening type and fixing arrangement i.e nuts, bolts, washers, clamps etc, with naturally air cooled epoxy insulated aluminium busbar TPN with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, all control cables shall be of 2.5 Sqmm copper multi stranded conductors and shall be properly bunched with suitable size binding materials , ferruled for proper identification of colour codes and crimped with adequate size of lugs also to accommodate, fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and consisting of the following items, including taking down the old unserviceable LT Panel/feeder pillar of any size/ any type, all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58205245
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.45 Crore
LAST DATE 21-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Building No Np-37 (Grc Main Office) At Grc K Tee.
Basic Detail
Tender No 84951/E8
Bidding Type Tender
Location
City Nagpur
State Maharashtra
Key Dates
Publish Date 24 Oct 2026
Submission Date 21 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 1.45 Crore
Tender Fee 1000
EMD 2.20 Lakhs
Exemption Available
Document List
2e9218ba-62b8-40d4-b3e8-9162115010a1.html
BOQ_892329.xls
Tender51.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

2e9218ba-62b8-40d4-b3e8-9162115010a1.html

xls

BOQ_892329.xls

pdf

Tender51.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender