Tender For Supply And Installation Of Safety Equipment Of 33/0.440 Kv Sub Station Of Gulab Sagar Dam Mahan Project Distt. Sidhi (M.P.)
Tender Overview
Project Description
Tender For Supply And Installation Of Safety Equipment Of 33/0.440 Kv Sub Station Of Gulab Sagar Dam Mahan Project Distt. Sidhi (M.P.)-1. Supplying, Installation, Testing And Commissioning Of Triple Pole Outdoor Type 11Kv/33Kv Vacuum Circuit Breaker With Outdoor Control & Relay Panel With Numerical Static Relay For Feeder Protection (1F). The Installation Of Vcb Shall Be Carried Out In Accordance With Is: 3072. The Vcb Shall Be Mounted On Suitable Size Duly Painted Ms Channel/Angle Iron Structure With Nut Bolts And Washer. The Structure Shall Be Fixed On Existing Cement Concrete Foundation. The Complete Work Should Be Done As Per Is Specification. 33 Kv, 1250A Vcb Each 01 319644.00 319644.00 Three Lakh Ninteen Thousand Six Hundred Forty Four Only 2 Supplying, Installation, Testing And Commissioning Of Single Phase C.T./P.T. Outdoor Type 11Kv/33Kv With Terminal Box. The C.T./P.T. Shall Be Mounted On Existing Structure Fabricated With Suitable Size Ms Channel/Angle Iron Structure With Nut Bolts And Washer Duly Painted. The Structure Shall Be Fixed On Existing Cement Concrete Foundation As Per Is Specification As Mentioned Below. 33 Kv/110V Single Phase Pts Oil Immersed Each. 03 20488.00 61464.00 Sixty One Thousand Four Hundred Sixty Four Only 3 Supplying, Installation, Testing And Commissioning Of Indoor Control Relay Panel Shall Consisting Of Ammeter,Voltmeter, Selector Switch, Auxiliary Relays For Anti-Pumping Device, Trip And Alarm Of Buchholz Relay, Oil And Winding Temperature Circuit, Electronic Hooter, 230V Ac To 110 V Dc Power Pack With Charging Equipment For Closing, Tripping And Indication, Triple Pole Idmtl Two O/C And One E/F Delay With Current Setting Range 50-200% And 10-50%, Push Button High Speed Trip Relay Etc. Complete As Per Is Specification Each. 01 129039.00 129039.00 One Lakh Twenty Nine Thousand Thirty Nine Only 4 Supplying Installing, Testing & Commissioning Of Outdoor H.T., Ab Switch Assembly Set Gang Operated With Brass Contact Parts, Including Required Gi Pipe Operating Rod, Handle & Locking Arrangement On On-Off Position Conforming To Is Complete With Required Material And Installing On Existing Dp Structure To Complete The Job As Required As Per Specification.(Set Of 3 Nos.) A 33Kv, 600Amp Set 01 31525.00 31525.00 Thirty One Thousand Five Hundred Twenty Five Only 5 Supply, Fabrication And Erection Of Angle/Channel/Flat Iron Fitting For Overhead Line & Sub-Station Etc Such As D Bracket, Cross Arms, Top Clamp, V Cross Arms,Back/Support Clamp Or Other Similar Work Etc. Including Nut Bolts Of Required Size, Making Holes, Fabrication, Welding, Cutting, Etc. And Painting With One Coat Of Red Oxide Paint & Two Coat Of Aluminium Paint As Required As Per Specification. Kg 150.0 105.00 15750.00 Fifteen Thousand Seven Hundred Fifty Only 6 Supplying And Erection Of Single Piece Nonlinear Resistor Polymer Type Lightning Arrestor (Set Of 3 Nos) For 3 Wire, 33Kv Overhead Lines/ Sub-Station With Rated Voltage Of 27Kv (Rms) With A Nominal Discharge Current Rating Of 10 Ka And Complete With Galvanized Clamping Arrangement, G.I. Bolts, Nuts, Washer Etc. As Required. 7 Supply Of Is1 Marked And Approved Make Of Air Circuit Breaker (Acb) With Microprocesor Release With Overload, Short Circuit, Neutral Protection, Instantaneous, Ground Fault Protection (Lsing) Les-Leu-Lew For Isee For Total Selectivity, Ambient Temperature 50Deg.C. Breaking Capacity Of 50 Ka/60Ka/75Ka, 4 Pole, 415Volts Conforming To I5/Iec 60947-2 1000Amp, Manual, Fixed 8 Supplying Of Is1 Marked And Approved Make Of Moulded Case Cucuit Breaker (Mccb) Suitable For 3 Phase & N, 4 Pole, 50 Hz, 415 Volts, (Les 100%Leu) Ac Supply With Thermal-Magnetic Release Having Respective Breaking Capacity (Ka) At 415 Volts Cited Against Their Nange Standard Conforming To Is/Iec 60947-2 Mccb 36&A Cunent Rating 400Amp & Adjustable Overload Setting 80%-100% Of In, Adjustable Short Circuit Setting 6-10 In 4 Pole 9 30 Volts 100 Ah Lead Acid Battery With San Container 10 Battery Charger 230 V Ac Input 20 Amp, 30 V Dc Output Solid State Type 11 Marshelling Box With 10 No. Connectors 12 Heat Shrinkable Insulation Sleeve For 33 Kv Dog Conductor 13 Copper Control Cable 4 Core 2.5 Sqmm Pvc Unarmour 14 Copper Control Cable & Core 2.5 Sqmm Pvc Unarmored 15 Copper Control Cable 12 Core, 2.5 Somm Pvc Unarmored 16 Strip Providing And Fixing 25Mm X 5Mm Copper On Surface Or In Recessed For Connection Etc. As Required 17 T Clamp Aluminum For Bus Bar Panther Run Panther Tap
BOQ
| Sl. No. | Item Description |
| 1 | Supply & installation of safety equipment of 33/0.440 KV sub station of gulab sagar Dam mahan project distt. sidhi (M.P.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender