Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #58204126

Tender For Special Repair To Conversion Of Overhead Lines Into Underground Cable With Connected Accessories At Narendra Nagar Area Under Ge 871 Ews.

Issued by Statutory Bodies & Commissions/Committees · Tehri Garhwal, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Nov 2026
6 days left
EMD
78000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tehri Garhwal → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Conversion Of Overhead Lines Into Underground Cable With Connected Accessories At Narendra Nagar Area Under Ge 871 Ews.

BOQ

Name of Work:- SPECIAL REPAIR TO CONVERSION OF OVERHEAD LINES INTO UNDERGROUND CABLE WITH CONNECTED ACCESSORIES AT NARENDRA NAGAR AREA UNDER GE 871 EWS.
Sl. No. Item Description
1SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS.
2XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 150.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
3Description all as per serial item No- 1.01 here-in-before but for cable of size 120 Sqmm 3.5 core
4Description all as per serial item No- 1.01 here-in-before but for cable of size 95 Sqmm 3.5 core
5Description all as per serial item No- 1.01 here-in-before but for cable of size 70 Sqmm 3.5 core
6Description all as per serial item No- 1.01 here-in-before but for cable of size 50 Sqmm 3.5 core
7Description all as per serial item No- 1.01 here-in-before but for cable of size 35 Sqmm 3.5 core
8Description all as per serial item No- 1.01 here-in-before but for cable of size 25 Sqmm 3.50.0 core
9Description all as per serial item No- 1.01 here-in-before but for cable of size 16 Sqmm 4.0 core
10Description all as per serial item No- 1.01 here-in-before but for cable of size 10 Sqmm 4.0 core
11Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for shafts, wells, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for laying of cable or pipe line or in foundation of poles, complete all as specified and as directed.
12Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed.
13Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed.
14Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed.Note: Punned thickness shall be measured.
15Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed.
16Tubes, 'light grade' galvanised, 80mm bore, ISI marked including all fitting such as bends, socket, connectors, back nuts, etc, laid in trenches or under floors, complete all as specified and as directed.
17Description all as per serial item No- 1.15 here-in-before but of size 50 mm bore
18Description all as serial item No- 1.15 here-in-before but of size 40 mm bore
19Factory made junction box, made with thermo polycarbonate/ Fiber Reinforced Polymer, weather, water and vermin proof, dust proof, for outdoor use, having internal dimensions 240mmx150mmx100mm, suitable for road/ street lighting for 3-phase/ 4-core high wattage LED based lighting system for industrial applications, suitable for pole mounting, including 01 No. MCB single pole, 6 Amps and 03 Nos. aluminium bus bars of 100 Amps rating duly drilled holes for connections, cable glands, clamps etc for making necessary connections along with locking arrangement, including mild steel iron flat size 25x4mm having holes, nuts, bolts, washers, for fixing/ mounting on poles, painted with two coats of synthetic enamel paint over one coat of primer on internal and external surfaces, fixing in repairs, complete all as specified and directed.
20PVC insulated and PVC round Sheathed, cross-sectional area, 2.50 Sqmm, 3.0-core, multi-stranded, annealed bare copper conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694:2010, complete all as specified and directed.
21Supply installation, commissioning, new LT feeder pillar box/ panel, in-replacement of old unserviceable LT panel/ feeder pillar box, complete all as specified and as directed by Engineer-In-Charge.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 21 of tender (CA) here-in-after.
22Supply installation, commissioning, new LT feeder pillar box/ panel, in-replacement of old unserviceable LT panel/ feeder pillar box, complete all as specified and as directed by Engineer-In-Charge.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 21 of tender (CA) here-in-after.
23Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 25x4mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed.Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
24Supply installation, commissioning, new LT feeder pillar box/ panel, in-replacement of old unserviceable LT panel/ feeder pillar box, complete all as specified and as directed by Engineer-In-Charge.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 22 of tender (CA) here-in-after.
25Replacement of old unserviceable/ damaged cable jointing kit with new cable jointing kit for Cable jointing kit for 1.1 KV (Earthed) grade cable for for straight through heat shrink type joint, complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm, 3.5-core/4.0-core, complete all as specified and as directed.
26Description all as per serial item No- 1.24 here-in-before but for cable of size 25 Sqmm to 50 sqmm
27Description all as per serial item No- 1.24 here-in-before but for cable of size 70 Sqmm to 150 sqmm
28Dismantling cross-arms of Mild Steel channel or angle sections etc. complete and setting aside for re-use, complete all as specified and as directed.
29Dismantling insulators any type, any size, complete all as specified and as directed.
30Dismantling stay assembly complete demolition of concrete, etc. and excavation, complete all as specified and as directed.
31Dismantling earth wire or copper conductor, service feeder or distributor span, complete all as specified and as directed.
32Dismantling of ACSR or AAC conductors, complete all as specified and as directed.
33Amount of Schedule of credit as mentioned here-in-after shall be deducted from quoted amount. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58204126
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 16-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Conversion Of Overhead Lines Into Underground Cable With Connected Accessories At Narendra Nagar Area Under Ge 871 Ews.
Basic Detail
Tender No 8189/E8
Bidding Type Tender
Location
City Tehri Garhwal
State Uttarakhand
Key Dates
Publish Date 26 Oct 2026
Submission Date 16 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 78000
Exemption Available
Document List
adf37617-e2e3-4e64-a953-44ef8fa12b32.html
BOQ_892401.xls
E-Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

adf37617-e2e3-4e64-a953-44ef8fa12b32.html

xls

BOQ_892401.xls

pdf

E-Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender