Tender For Construction Work Of Wells At Different Places In Between Km. 51.000 To Km. 62.106 Of C Ierganj Branch In District Maharajganj.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Nov 2026
10 days left
EMD
7.83 Lakhs
Bank guarantee accepted
Document Fee
7327
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Maharajganj → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Work Of Wells At Different Places In Between Km. 51.000 To Km. 62.106 Of C Ierganj Branch In District Maharajganj.
BOQ
| Sl. No. | Item Description |
| 1 | E/W in Making coffer dam etc in all types of soil with all leads & lifts and dressing including cost of all T&P,Labour etc required for proper completion of work. |
| 2 | E/W in excavation of foundation in all type of soil including lead up to 30m lift up to 1.50m and its proper disposal and back filling as per direction by engineer in charge required for proper complection of work including cost of all T&P,Labour etc. |
| 3 | Laying C.C- A 40 M-10 in foundation of all structures with Cement O.P.C.,43 grade coarse sand of F.M. not less than 2.0 and hard stone ballest (20-40mm size) including lead up to 60.0 m.lift up to 3.0 m. mechanical mixing & mechanical vibration but excluding cost of Centering and shuttering required for proper completion of work including cost of all material T&P. etc. |
| 4 | Laying R.C.C, A-20, M-25 with cement coarse sand of F.M not less than 2.5 and crushed hard stone grit of size 4.75 to 20mm, including lead up to 60m lift up to 3m, mechnical mixing & mechnical vibration but excluding cost of centering and shuttering required for proper completion of work including cost of all meterial, T&P, Labour etc. |
| 5 | Centering & Shuttering for C.C & R.C.C work with all lead & lift reqired for proper completion of work including cost of all material and scafolding labour, T&P etc. |
| 6 | Cutting bending binding and placing TMT steel bar for reinforcement with cost of binding wire with required for proper compltion of work including cost of all material, labour, T&P etc |
| 7 | Dewatering with all cost of power POL machine pump, well point system & operator with assembling & dismantling of equipment etc/kwh. |
| 8 | Filling of local sand with all lead lift, including excavation, loading, unloading, with all cost of labour T&P etc. complete in all respects. |
| 9 | Providing & Supplying of I.S.I. Marked H.D.P.E. Pipe confirming to I.S. 4984:2016 or its latest HDPE Pipe dia 200mm/PN-6. |
| 10 | Brick work in sub-structure with cement 1:4 including cost of material labour T&P etc. |
| 11 | Providing & Fixing Steel angles and m.s. plate square bars for door, windows& asbestus sheet including cost of all material T&P etc. |
| 12 | 12 mm thick cement plaster 1:6 including cost of material T&P etc. |
| 13 | Distempering first coat with oil bound distemper of approved brand and manufacture of required shade on undercoat wall surface to give an even shade over an including a priming coat cement primer of aproved brand and manufacture such as berger with material proper smooth including cost off all material. |
| 14 | Supply and installation of 5 HP pumping plant including pump with motar starter panel cable complete in all respect with all requred material t&p etc. |
| 15 | Site solar power plant(complete plant) including solar panel structure inverter etc. complete in all respect with required material t&p etc. |
| 16 | S/L 150mm dia thick m.s. pipe including with spigot collar i/c cost of all material, labour T&P etc. complete for proper completion of works. |
| 17 | Gunmetal valve 80 mm dia-As per DSR code no 3300 |
| 18 | PVC water stop seal 10mm thick for proper completion of work including cost of all material, labour, T&P etc |
| 19 | Providing & fixing 80 mm to 100 mm nominal bore gun metal non- return valve of approved quality for proper completion of work including cost of all materials, labour, T&P etc. |
| 20 | Supply and fixing and concealing of 25mm dia. 16 SWG (1.5 mm.) thick rigid steel conduit pipe in the wall including cutting of brick work, laying of conduit and fixing it with M.S. hooks and then plastering with cement, sand mortar finished to the level, with matching colour wash including cost of proper threading of the conduit & providing necessary socket, bends and chuck nuts and as directed by the Engineer in charge with the supply of all material labour and T&P required for proper completion of work. |
| 21 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 22 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 23 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate formodular switches in recess etc.as required.8 Module (125mmX125mm) |
| 24 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required. 4 Module (125mmX75mm) |
| 25 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, inter connections, powder painted including earthing etc. asrequired.(But without MCB / RCCB / Isolator) 8 way , Double door. |
| 26 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (DB to SB). |
| 27 | Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (DB to Power). |
| 28 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required. |
| 29 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular witches in recess etc.as required. 1 or 2 Module (75mmX75mm) BOX |
| 30 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet. |
| 31 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 32 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
| 33 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. |
| 34 | Unbranded tungesten halogen flood light 50 watt on surface complete in all respect. |
| 35 | LUMINOUS LCD on grid solar inverter 4 kw. |
| 36 | LUMINOUS Polypropylene Co-polymenr (PPCP) stationary Value Regulated Lead Acid Batteries 12 Volt 150 Ah HSN CODE 8507 |
| 37 | Providing and fixing G.I. chain link fabric fencing of Required width in mesh size 50x50 mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 38 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 66 m) heaving 50 nos round per 6 metre length upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.40 m or 3.00 metre apart and with 9 horizantal R.B.T. reinforced barbed wire ,stud tied with G.I. staples and G.I. clips to retain horizontal ,including neccessary bolts or G.I. barbed wire tied to angle iron ,all complete as per direction of Engineer-in charge |
| 39 | Priming and painting of steel surfaces including all cost of all materials T&P etc. required for proper completion of work. |
| 40 | Brick on Edge Soling on road diversion with preparation of subgrade and filling joints with local earth with proper completion of work including cost of all material, labour and T.& P. etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender