Defence Government Departments Closing in 16 days TDR #58202593

Tender For Repair / Maintenance And Replacement Of Defective Bfl Ug Cables And Mfp Installed In Aor Of Bfl Source Bop Bajarang Of 85 Bn Under Bsf Shq Bhuj

Issued by Government Departments · Kachchh, Gujarat
Tender Value
49.79 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
16 days left
EMD
99598
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance And Replacement Of Defective Bfl Ug Cables And Mfp Installed In Aor Of Bfl Source Bop Bajarang Of 85 Bn Under Bsf Shq Bhuj

BOQ

Name of Work:- REPAIR / MAINTENANCE AND REPLACEMENT OF DEFECTIVE BFL UG CABLES AND MFP INSTALLED IN AOR OF BFL SOURCE BOP BAJARANG OF 85 BN UNDER BSF SHQ BHUJ
Sl. No. Item Description
1Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
33½ X 25 sq. mm (28mm)
43½ X 35 sq. mm (32mm)
53½ X 70 sq. mm (38mm)
63½ X 95 sq. mm (45mm)
73½ X 120 sq. mm (45mm)
83½ X 185 sq. mm (57mm)
9Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
103½ X 35 sq. mm
113½ X 95 sq. mm
123½ X 120 sq. mm
13Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench/foundation/Surface complete as required.
1463 mm dia (OD-63 mm & ID-51 mm nominal)
1590 mm dia (OD-90 mm & ID-76 mm nominal)
16120 mm dia (OD-120 mm & ID-103 mm nominal)
17Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
18Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
19Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
20Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
21Earthing with G.I. earthing Electrodes 2 metre long, 25 mm dia including accessories, and providing connection with GI/MS pole by existing 25mm X 6 mm GI strip as required.
22Supplying and laying of 3.5 X 25 Sqmm one number PVC insulated and PVC sheathed / XLPE armoured Aluminium cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering etc. as required.
23Supplying and laying of 3.5 X 25 Sqmm one number PVC insulated and PVC sheathed / XLPE armoured Aluminium cable of 1.1 KV grade as per IS 7098 (Part 1) 1988 in the existing RCC/ HUME/ METAL/ pipe,surface as required.
24Supplying and laying of 3.5 X 70 Sqmm one number PVC insulated and PVC sheathed / XLPE armoured Aluminium cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering etc. as required.
25Supplying and laying of 3.5 X 70 Sqmm one number PVC insulated and PVC sheathed / XLPE armoured Aluminium cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, direct in the existing RCC/ HUME/ METAL/ pipe,surface as required
26Supplying and laying of 3.5 X 95 Sqmm one number PVC insulated and PVC sheathed / XLPE armoured Aluminium cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering etc. as required
27Supplying and laying of 3.5 X 95 Sqmm one number PVC insulated and PVC sheathed / XLPE armoured Aluminium cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, direct in the existing RCC/ HUME/ METAL/ pipe,surface as required.
28Supplying and laying of 3.5 X 120 Sqmm one number PVC insulated and PVC sheathed / XLPE armoured Aluminium cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering etc. as required
29Supplying and laying of 3.5 X 120 Sqmm one number PVC insulated and PVC sheathed / XLPE armoured Aluminium cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, direct in the existing RCC/ HUME/ METAL/ pipe,surface as required.
30Fabrication, supplying , installation and testing of outdoor type front & back openable electrical feeder pillar of size 1400 mm x 1100 mm x 550 mm deep (>0.847cum) fabricated out of 2.0 mm CRCA sheet with intermediate membes of same material and guage as required. The box should be supported by 500 mm long legs and frame made by 50 mm x 50 mm x 6 mm thick MS angle iron at the base and almirah type single leaf hinged door with locking arrangement, detachable gland plate made of 3 mm thick MS sheet at the bottom suitable for inlet & outlet of PVC / XLPE UG cable & bolts, water drip proofing arrangement at the top, air ventilation grooves at sides dust and vermin proof design, earthing studs, 200 Amp 4 Nos. aluminium strip bus bar having base connector insulation, and having (A) 01 Nos 125 Amp, 36 KA, 415V 4P MCCB (B) 01 Nos 80 Amp, 36 KA, 415V MCCB (C) 02 Nos 63 Amp, 36 KA, 415V MCCB (D) 02 nos 40 Amp 4P MCB and painted with power coated paint etc. as required. (CPRI approved)
31Fabrication, Supplying ,installation, testing and commissioning of cubical type padestal mounted outdoor Junction Feeder Pillar of size 550mmX550mmX450mm made out of 1.6 mm. thick CRCA sheet complete and mounted on 35mm x 35mm x 5mm thick angle iron frame i/c same size of angle 04 nos. legs 500mm length erected in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation (min 0.099cum) including excavation & refilling, hinged front & back doors with latch locking arrangements, with provision of fixing of glands at the bottom, antirust design, air ventilation grooves, water drop proofing arrangement ,insulators, earthing studs & connection with 25mm x 5 mm 2 mtr GI strip, nuts bolts etc.as required including connections, interconnections , painting with primer & finish paint with synthetic enamel paint , 04 nos aluminium bus bar strip suitable for 250 A,415 V capacity with suitable insulated support for aluminium bus bar complete as required . CG box/panel should be made CPRI approved from authorized fabricators. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58202593
AUTHORITY Government Departments
TENDER VALUE 49.79 Lakhs
LAST DATE 12-11-2026
Authority
Authority Name Border Security Force
Work Description Tender for Repair / Maintenance And Replacement Of Defective Bfl Ug Cables And Mfp Installed In Aor Of Bfl Source Bop Bajarang Of 85 Bn Under Bsf Shq Bhuj
Basic Detail
Tender No 21/2IC(E)/FTR GUJ/ENGG/SHQ-BHUJ/2026-27
Bidding Type Tender
Location
City Kachchh
State Gujarat
Key Dates
Publish Date 24 Oct 2026
Submission Date 12 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 49.79 Lakhs
Tender Fee Ref. Documents
EMD 99598
Exemption Available
Document List
44dbdc09-c48a-438c-8cd1-c964cbf6d36e.html
BOQ_979008.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

44dbdc09-c48a-438c-8cd1-c964cbf6d36e.html

xls

BOQ_979008.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender