Tender For Replacement Of Iei And Allied Electrical Works At Atal Adarsh Prathamik Vidyalaya, R K Ashram Marg And Atal Adarsh Vidyalaya, Balmiki Basti School, Navyug School Peshwa Road, Under Polyclinic Enquiry, Bm-I
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Nov 2026
3 days left
EMD
74564
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Iei And Allied Electrical Works At Atal Adarsh Prathamik Vidyalaya, R K Ashram Marg And Atal Adarsh Vidyalaya, Balmiki Basti School, Navyug School Peshwa Road, Under Polyclinic Enquiry, Bm-I
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group - C (LIGHT POINT-71,FAN POINT-27,EXHAUST POINT-14 ,CALL BELL POINT-4) |
| 2 | Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing asrequired. |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS / HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 4 | (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 5 | (c) 2x10 sq. mm. + 1x6 sq. mm earth wire. |
| 6 | (d)4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 7 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 1 x 1.5 sq. mm |
| 8 | (b) 2 x 1.5 sq. mm |
| 9 | [c] 3 x 2.5 sq. mm |
| 10 | (d) 3 x 4 sq. mm |
| 11 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a)25 mm |
| 12 | S&F metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in Front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as reqd. |
| 13 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 14 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 16 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 17 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. Make:- Schneider Electric /Legrand /Anchor /Havells (A) 5/6 amps switch |
| 18 | (B) 3 pin 5/6 A socket outlet |
| 19 | [c] 15/16 A switch |
| 20 | (D) 15/16 A switch |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make:-Schneider Electric/Legrand/Anchor /Havells (a) 5/6 A switch |
| 22 | (b) 3 pin 5/6 A socket outlet |
| 23 | [c] 15/16 A switch |
| 24 | (d) 6 pin 15/16 A socket outlet |
| 25 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. Make:-Havells/Anchor/Legrand/Schneider(a) 6 Module |
| 26 | (b) 12 Module |
| 27 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (a) 6 Module (200mmX75mm) |
| 28 | (b) 12 Module (200mmX150mm) |
| 29 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 30 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 31 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as required(a) upto 450 mm sweep |
| 32 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 33 | Earthing with G.I. Earth pipe 4.5 mtr. Long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as reqd |
| 34 | Supplying and laying 6 SWG GI wire at 0.50 meter below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required |
| 35 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. Make:-Havells/Legrand/Schneider Electric/L&T Electrical & Automation (a) 200 A,36KA,FPMCCB |
| 36 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). (Note - The DB shall include proper ferruling for all incoming and outgoing wires, including MCB numbering using printed PVC ferrules, DB number marking on the front door, and circuit schedule sheet pasted inside the DB with corresponding MCB circuit details All wires shall be tagged appropriately with ferrule numbers matching the circui designation for easy identification and maintenance. Neutral and earth link bars shall be clearly differentiated using colored ferrules e.g., black for neutral, green for earth for each connected wire to ensure easy identification and compliance with standards.) Note: i) Surface or flush mounted DB's shall be provided with suitable size frame work and neatly grouted on to wall and DB shall be fixed on to the frame work using bolts & nuts and other fixing accessories.ii) DB's concealed in wall shall include cut of necessary civil works and other fixing accessories. iii) The DB's shall be horizontal / vertical type as per configuration of incoming/outgoing feeders. iv) The DB's shall be factory made of approved makeand necessary available higher size configured DB's shall be used using approved makes such as Havells, Schneider, Legrand or L&T. (a) 12 way Double Door |
| 37 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole, makes such as Havells, Schneider, Legrand , |
| 38 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. makes such as Havells, Schneider, Legrand (a) 63 Amps |
| 39 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. makes such as Havells, Schneider, Legrand (a) 63 Amp |
| 40 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (Note : Vertica type MCB TPDB is normally used where 3 phase outlets are required.), makes suchas Havells, Schneider, Legrand(a) 4 way (4 + 12), Double door |
| 41 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a)Double pole |
| 42 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 43 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum), make-BAJAJ/ORIENT/CROMPTON/HAVELLS/USHA |
| 44 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying Installation, Testing & Commissioning of LED surface mounted Batten light o following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3 Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm), 18-22 Watt. Make:- Philips / Havells / Bajaj / Crompton |
| 45 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cas aluminium body with driver as per the requirement with Driver efficiency >85% Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70,under voltage and over voltage protection, EMI EMC As per CISPR -15 lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initia Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as pe requirement. (Thermal management: heat sink of aluminium housing such tha LED junction temperature shall not rise above 90°C). Make:-Philips/Crompton/Havells/Bajaj (A) 90 watt |
| 46 | Supply and fixing of 2x20 watt LED batten type luminari of 4 ft length with tube The luminari shall be weather proof IP 65 (minimum) protected. The housing shal be UV resistant poly carbonate diffuser shall be open polycarbonate for clear free illumination CCT 6000-6500 K, Intensity> 100 Lumens CR>100 PF > 0.9 with 02 years warranty. Complete as required. Make :Crompton, Havells, Phillips |
| 47 | Supply & fixing of cubical board made out of CRCA sheet 16 SWG, powder coated, of size 750 × 450 × 300 mm (nominal), suitable for installation of 100 A,30KA, 4P MCCB as incomer. The cubical board should be Providing and fixing with 1 No. 100 Amps, 30 kA breaking capacity, 4 Pole MCCB as incomer with thermomagnetic release and terminal spreaders the cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operationa Voltage 690V etc. as required, including all internal connections, mounting, and termination and The panel should be provided with copper bus-bar chamber having 4 Nos. copper bus bars of suitable size (25 mm x 5 mm x 200 mm or as required for 200 A rating) with proper supports, insulation, and terminations. The cubical board should be provided with adequate neutral link and a separate earth link (earth bar) of suitable capacity with multiple termination points. The panel shall include Ammeter, Voltmeter with selector switch, RYB indicating lamps, and complete internal wiring using suitable size copper conductors of 16 sqmm wire, thimbles and accessories. Proper ferruling, numbering, dressing of wiring with cable ties, and colour coding as per IS standards shall be ensured. The work includes grouting in the wall, complete connection, testing, commissioning, painting, and providing locking arrangement with 65 mm size lock, ventilation louvers, door handle, and danger plate. All masonry and whitewashing work required for installation shall be included. The scope also includes dismantling and safe removal of the existing electrical panel, proper disconnection of old cables, and installation of the new panel either flush or surface mounted as per site requirement, ensuring proper alignment. All incoming and outgoing cables shall be terminated using ISI-marked copper thimbles and secured with appropriate machine screws, nuts, bolts, and washers. Proper ferruling and numbering shall be done for all wires. Internal wiring shall be neatly arranged using insulated bus bar links and sleeves. Wiring shall be properly dressed with cable ties for a clean and professional finish. Colour coding shall be strictly followed as per IS standards: red, yellow, and blue for phases, black for neutral, and green for earthing. Clear and permanent printed labels shall be provided for the incomer and each outgoing circuit, along with a proper panenameplate. All internal connections shall be carried out using insulated copper conductors of adequate capacity, ensuring safety and reliability with no loose connections. Make of MCCB :-Havells/Legrand/Schneider Electric/L&T Electrical & Automation |
| 48 | Supply & fixing of cubical board made out of CRCA sheet 16 SWG, powder coated, of size 750 × 450 × 300 mm (nominal), suitable for installation of 125 A,36KA, 4P MCCB as incomer. The cubical board should be Providing and fixing with 1 No. 125 A,36KA, 4P breaking capacity, 4 Pole MCCB as incomer with thermomagnetic release and terminal spreaders the cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operationa Voltage 690V etc. as required, including all internal connections, mounting, and termination and The panel should be provided with copper bus-bar chamber having 4 Nos. copper bus bars of suitable size (25 mm x 5 mm x 200 mm or as required for 125 A rating) with proper supports, insulation, and terminations. The cubical board should be provided with adequate neutral link and a separate earth link (earth bar) of suitable capacity with multiple termination points. The panel shall include Ammeter, Voltmeter with selector switch, RYB indicating lamps, and complete internal wiring using suitable size copper conductors of 16 sqmm wire, thimbles and accessories. Proper ferruling, numbering, dressing of wiring with cable ties, and colour coding as per IS standards shall be ensured. The work includes grouting in the wall, complete connection, testing, commissioning, painting, and providing locking arrangement with 65 mm size lock, ventilation louvers, door handle, and danger plate. All masonry and whitewashing work required for installation shall be included. The scope also includes dismantling and safe removal of the existing electrical panel, proper disconnection of old cables, and installation of the new panel either flush or surface mounted as per site requirement, ensuring proper alignment. All incoming and outgoing cables shall be terminated using ISI-marked copper thimbles and secured with appropriate machine screws, nuts, bolts, and washers. Proper ferruling and numbering shall be done for all wires. Internal wiring shall be neatly arranged using insulated bus bar links and sleeves. Wiring shall be properly dressed with cable ties for a clean and professional finish. Colour coding shall be strictly followed as per IS standards: red, yellow, and blue for phases, black for neutral, and green for earthing. Clear and permanent printed labels shall be provided for the incomer and each outgoing circuit, along with a proper pane nameplate. All internal connections shall be carried out using insulated copper conductors of adequate capacity, ensuring safety and reliability with no loose connections. Make of MCCB :-Havells/Legrand/Schneider Electric/L&T Electrical & Automation |
| 49 | Supply, installation, testing, and commissioning of a heavy-duty exhaust fan suitable for continuous ventilation (size as mentioned below). The fan shall operate on 230V AC, 50 Hz, equipped with a copper-wound motor having therma overload protection and sealed ball bearings for long life. The fan shall deliver a minimum air delivery of 900–1350 m³/hr with low noise operation. The body and front guard shall be made of powder-coated metal or high-strength ABS polymer depending on the model, with three aerodynamically balanced blades ensuring smooth, vibration-free running. The exhaust fan shall also include a factory-fitted louvers/shutter mechanism for preventing reverse airflow, insects, and dust ingress Installation includes fixing of fan frame using anchor fasteners, providing necessary supports, and sealing gaps around the fan with cement mortar/PU sealant for dust-free installation. The fan shall be of approved make such as Crompton / Havells Usha / Orient / Bajaj or equivalent, complete with all accessories with 02 years warranty. (b) 380 mm (15 inch) |
| 50 | Supply & laying of 4 Core 25 Sq.mm Aluminium Conductor, XLPE Insulated Armoured, 0.6/1kV Grade LT Power Cable. The cable shall be suitable for 415 V 3-phase, 4-wire system with stranded aluminium conductor as per IS 8130.Installation shall include laying, dressing, termination with bi-metallic lugs,double compression glands, and proper earthing. make;- havells/Polycab /RR Kabel |
| 51 | Supply and laying of 1.1 kV grade, XLPE insulated, PVC sheathed, armoured aluminium conductor cable of size 3.5 core × 50 sq.mm, conforming to Bureau of Indian Standards and IS 7098 Part 1.The cable shall be suitable for 415 V, 3-phase 4-wire system with stranded aluminium conductor as per IS 8130.Installation shalinclude laying, dressing, termination with bi-metallic lugs, double compression glands, and proper earthing. make;-havells/Polycab /RRKabel |
| 52 | Dismantling of existing ceiling fans etc including depositing in the JEE store at Polyclinic wiring enquiry complete as required to the satisfaction of the engineer in charge |
| 53 | Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysNov 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender