Tender For Addition/Alteration & Allied Works In Children School Chandimandir
Tender Value
11.76 Crore
Estimated cost
Bid Submission
28 Nov 2026
24 days left
EMD
9.14 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition/Alteration & Allied Works In Children School Chandimandir
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-Oct-2026 | CORRIGENDUM01 | BOQ | 28-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Total amount of Sch 'A' Sec-I (BUILDING WORKS) Lump sum price worked out by the contractor for \\" BUILDING WORKS \\" as listed in Schedule 'A' Section-I |
| 2 | Total amount of Sch 'A' Sec-II (SITE CLEARANCE, SITE DEVELOPEMENT & MISC. EARTH WORKS) Lump sum price worked out by the contractor for \\" SITE CLEARANCE, SITE DEVELOPEMENT & MISC. EARTH WORKS \\" as listed in Schedule 'A' Section-II |
| 3 | Total amount of Sch 'A' Sec-III ( INTERNAL WATER SUPPLY) Lump sum price worked out by the contractor for \\" INTERNAL WATER SUPPLY \\" as listed inSchedule 'A' Section-III |
| 4 | Total amount of Sch 'A' Sec-IV (INTERNAL ELECTRIFICATION WORKS) Lump sum price worked out by the contractor for \\" INTERNAL ELECTRIC SUPPLY \\" as listed in Schedule 'A' Section-IV. |
| 5 | Total amount of Sch 'A' Sec-V (SEWAGE DISPOSAL) Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL \\" as listed in Schedule 'A' Section-V |
| 6 | Total amount of Sch 'A' Sec-VI (AREA DRAINAGE WORKS) Lump sum price worked out by the contractor for \\"AREA DRAINAGE WORKS \\" as listed in Schedule 'A' Section-VI. |
| 7 | Total amount of Sch 'A' Sec-VII (ROAD/PATH AND HARDSTANDING ) Lump sum price worked out by the contractor for \\" ROAD/PATH AND HARDSTANDING \\" as listed in Schedule 'A' Section-VII. |
| 8 | Total amount of Sch 'A' Sec-VIII (RETAINING WALL WORKS ) Lump sum price worked out by the contractor for \\" RETAINING WALL WORKS \\" as listed in Schedule 'A' Section-VIII. |
| 9 | Total amount of Sch 'A' Sec-IX ( CHAIN LINK FENCING & GATE WORKS ) Lump sum price worked out by the contractor for \\"CHAIN LINK FENCING & GATE WORKS \\" as listed in Schedule 'A' Section-IX |
| 10 | Total amount of Sch 'A' Sec-X (FIRE FIGHTING ) Lump Sum price worked out by the contractor for \\"FIRE FIGHTING \\" as listed in Schedule 'A' Section-X.`` |
| 11 | Total amount of Sch 'A' Sec-XI (DEMOLITION WORKS ) Lump Sum price worked out by the contractor for \\"DEMOLITION WORKS \\" as listed in Schedule 'A' Section-XI. |
| 12 | Total amount of Sch 'A' Sec-XII ( SOLAR POWERED STREET LIGHTS) Lump sum price worked out by the contractor for \\" SOLAR POWERED STREET LIGHTS\\" as listed in Schedule 'A' Section-XII. |
| 13 | Schedule 'A' Section-XIII (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only. |
| 14 | INTERNAL WATER SUPPLY |
| 15 | CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings,20 mm outer diameter with and including all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 16 | CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings,25 mm outer diameter with and including all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed.NOTE: (a)CPVC pipes SDR 11& plain CPVC SDR 11 fittings shall be fixed concealed inside the building and shall be fixed on the surface of wall outside the building complete all as directed by Engineer-in-Charge. (b)Cost of cutting/chases shall be included in the rates above |
| 17 | CPVC Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball screwed for CPVC pipe and fixed. (Minimum weight -690gms) for 25 mm bore CPVC pipe or for unions complete all as specified and directed. |
| 18 | Extra over srl item 17 and 18 above for provision of brass elbow 20X15mm fittings for CPVC pipe for 20 mm bore CPVC pipe or for unions complete all as specified and directed. |
| 19 | Extra over item 16 and 17 above for provision of brass TEE fittings for CPVC pipe for 20 mm bore CPVC pipe or for unions complete all as specified and directed. |
| 20 | Bib taps, cast copper alloy, fancy type, chromium plated, with capstan head, screwed for 20X15mm bore CPVC pipe or for brass ferrule complete all as specified and directed. |
| 21 | WATER TANK STAGING |
| 22 | Design,supply,fabrication,erection,testing and commissioning of a complete fire fighting water tank system of 10,000 litre capacity of Sintex or equivalent approved make,mounted on 12 metre high MS steel staging ,complete with all structural steel work,foundations,bolts, nuts, anchor, bracings, staircase, top raling,piping arrangement, overflow connection,domestic water flow arrangement through the tank, anti-corrosive painting, testing, vetting of structural design by NIT/IIT, SBC testing through contractor and all other accessories, material, labours,tools,plants,transport,and incidentals required for complete execution as per departmentals requirements and relevant IS codes. |
| 23 | Design,supply,fabrication,erection,testing and commissioning of a complete fire fighting water tank system of 10,000 litre capacity of Sintex or equivalent approved make,mounted on 8 metre high MS steel staging ,complete with all structural steel work,foundations,bolts, nuts, anchor, bracings, staircase, top raling,piping arrangement, overflow connection,domestic water flow arrangement through the tank, anti-corrosive painting, testing, vetting of structural design by NIT/IIT, SBC testing through contractor and all other accessories, material, labours,tools,plants,transport,and incidentals required for complete execution as per departmentals requirements and relevant IS codes. |
| 24 | DEMOLITION WORKS |
| 25 | Disconnecting the power supply and taking down carefully by unscrewing from boards fitting and fixture such as DBs, junction Box, panel of any size complete with all MCCBs, MCBs,etc and removing from site complete all as specified and directed. |
| 26 | Taking down old unserviceble sub main wiring any size complete all as specified and directed. |
| 27 | Taking down of Old LT XLPE insulated, galvanized steel strip armourred cable of any type/size complete all as specified and directed. |
| 28 | Dismantling of existing GI pipe of size 25 or 32 mm bore including valve stop complete all as specified and directed. |
| 29 | INTERNAL ELECTRIFICATIONS & F 7 W LED lamp, retrofit type suitable for B-22 holder base with polycarbonate diffuser complete all as specified and directed. |
| 30 | M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, 60 mm deep with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed for the following points:- |
| 31 | One light / exhaust fan / ceiling fan/ bell point controlled by one switch |
| 32 | One 6A socket point controlled by one switch on independent board |
| 33 | One 6A socket point controlled by one switch on same board |
| 34 | All as per srl item no. 31 here-in-above but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board complete all as specified and directed. Please Enable Macros to View BoQ information SCHEDULE OF CREDIT Notes:-(a) The items and quantities given under in the respective columns are provisional; however, the rates inserted for credit are firm. The recovery for the credit shall be made for the actual quantities ordered and retrieved from the demolition/dismantling /taking down under respective items of BOQ. Contractor shall be permitted to remove the materials indicated in this credit schedule only after affecting the recovery for the same from the RAR/Final bill asapplicable and after written permission is obtained by the contractor from the Engineer-in-Charge. (b) Tenderers are advised to visit the site to ascertain the worth value, prevailing conditions of the existing materials for which credit is to be afforded. No claim whatsoever on account of above shall however be entertained at any stage whether the contractor (s) inspected the site or not. (c) The old materials obtained will not be allowed to be re-used in the work unless it is specifically mentioned in the description of relevant items of BOQ. All other serviceable/ salvage value materials obtained from the site other than those considered in this schedule shall be Govt. property and contrator’s quoted rates shall be deemed inclusive of removing such material to MES store yard of the Engineer-in-Charge, who will take such material on charge. In case of the dispute related to the interpretation of the provision with regard to the credit schedule, the decision of the Accepting Officer shall be final & binding. Sl No DESCRIPTION OF ITEM A/U QTY RATE AMOUNT REMARKS |
| 35 | All as per srl item no. 31 here-in-above but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board complete all as specified and directed. Please Enable Macros to View BoQ information SCHEDULE OF CREDIT Notes:-(a) The items and quantities given under in the respective columns are provisional; however, the rates inserted for credit are firm. The recovery for the credit shall be made for the actual quantities ordered and retrieved from the demolition/dismantling /taking down under respective items of BOQ. Contractor shall be permitted to remove the materials indicated in this credit schedule only after affecting the recovery for the same from the RAR/Final bill asapplicable and after written permission is obtained by the contractor from the Engineer-in-Charge. (b) Tenderers are advised to visit the site to ascertain the worth value, prevailing conditions of the existing materials for which credit is to be afforded. No claim whatsoever on account of above shall however be entertained at any stage whether the contractor (s) inspected the site or not. (c) The old materials obtained will not be allowed to be re-used in the work unless it is specifically mentioned in the description of relevant items of BOQ. All other serviceable/ salvage value materials obtained from the site other than those considered in this schedule shall be Govt. property and contrator’s quoted rates shall be deemed inclusive of removing such material to MES store yard of the Engineer-in-Charge, who will take such material on charge. In case of the dispute related to the interpretation of the provision with regard to the credit schedule, the decision of the Accepting Officer shall be final & binding. Sl No DESCRIPTION OF ITEM A/U QTY RATE AMOUNT REMARKS |
| 36 | Old Terracing tiles and bats with mortar |
| 37 | Old unserviceable chowkhats or frame exc 1.50 sqm each but n exc 4 sqm each with shutters (without taking off shutters from the frame) |
| 38 | Old unserviceable chowkhats or frame n.exc 1.50 sqm each complete all as Specified and directed. |
| 39 | Old unserviceable chowkhats or frame 4.0 sqm each complete all as Specified and directed. |
| 40 | Old Retrieved brick |
| 41 | Old Retrieved galvalume Corrugated sheets |
| 42 | Old Retrieved MS Scrap |
| 43 | Old Retrieved brick |
| 44 | Old Retrieved GI Pipe 15mm bore |
| 45 | Old Retrieved GI Pipe 20mm bore |
| 46 | Old Retrieved PTMT bib tap/ stop cock/ pillar tap/ 15mm |
| 47 | Old Retrieved PVC connections 15mm dia with PTMT nuts |
| 48 | Old Retrieved PVC flushing cistern with fittings, 10 ltrs |
| 49 | Old U/S water tanks 1000 litre capacity |
| 50 | Old Retrieved Brass ball valve 20mm |
| 51 | Steel tubing & connections of the following sizes including all accessories and fittings complete 25 mm bore RM 100.0 40.0 4000.0 |
| 52 | valve stop , screwed of the following sizes 25 mm dia pipe Each 4.0 40.0 160.0 |
| 53 | Old XLPE LT cable of any type/size |
| 54 | Old Unserviceable point wiring |
| 55 | Old Unserviceable switches socket,bell,ceilling rose,batten holder and fan regulator |
| 56 | Old unserviceble light fitting of any watt and make |
| 57 | Old unserviceble DBs of any type |
| 58 | Old unserviceble MCCB/MCBs of any type |
| 59 | Old unserviceble submain wiring any type |
| 60 | Old earthings Total Amount of Sch of Credit Rs 1251925.9 Signature of Contractor For Accepting officer |
AI Tender Summary
Tender Timeline
Oct 30, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Nov 28, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 24 daysNov 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender