Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #58201630

Tender For Repair/Maintenance Of External Electrification Of 33 Kv Network At Mil Stn Kanasar Under Ge (N) Bikaner

Issued by Statutory Bodies & Commissions/Committees · Bikaner, Rajasthan
Tender Value
26 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
2 days left
EMD
52000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance Of External Electrification Of 33 Kv Network At Mil Stn Kanasar Under Ge (N) Bikaner

BOQ

Name of Work:- REPAIR/MAINTENANCE OF EXTERNAL ELECTRIFICATION OF 33 KV NETWORK AT MIL STN KANASAR UNDER GE (N) BIKANER
Sl. No. Item Description
1M&L for preventive maintenance / repairing by opening and taking out the Vacuum Circuit Breaker (VCB) /33 KV 800/1250 Amp and carry out the general maintenance such as oiling & greasing the mechanical parts, motor, gear, lever spring, operating rod, cleaning the female contacts, tightening of nuts and bolts, cleaning the male and female contact of panel, oiling the bus bar shutter, checking the AC/DC wiring, circuit including control fuses and circuit jack, on/off push button, indicating lamp, voltmeter, ammeter, PF meter, replacement of minor parts (where required) and testing after re-inserting the VCB in panel complete all as specified and as directed. The new replaced parts shall be measured and paid separately under appropriate item(i.e. 2 to 5) of Sch 'A' as supply only.
2Supply only Anti Pumping Relay should not be plug in type & should have suffcient number of contact as per existing installed on site complete all as specified and as directed.
3Supply only Tripping coil having copper material through actuating device rated for Substation DC voltage 12/ 24 /110 V ,burden value < 200 watt , Min operating Voltage of 70% for tripping and 85% for closing operation as per existing installed on site complete all as specified and as directed.
4Supply only Closing coil having copper material through actuating device rated for Substation DC voltage 12/ 24 /110 V ,burden value < 200 watt,, Min operating Voltage of 70% for tripping and 85% for closing operation as per existing installed on site complete all as specified and as directed.
5Supply only Spring charging motor operated on Power 150-250 Watts ,220 V AC/DC supply having insulation Class B type as per existing installed on site complete all as specified and as directed.
6M&L for replacing unserviceable parts of 33 KV transformer control panel and Vacuum Circuit Breaker (VCB) 33 KV include testing all parts after replacing and changing faulty wiring complete all as specified and as directed. The new replaced parts shall be measured and paid separately under appropriate item(i.e. 7 to 18) of Sch 'A' as supply only.
7Supply only Electromechanical Master trip relay Hand reset type Suitable for flush mounting and auxiliary DC supply of 24V as existing Make complete all as specified and as directed.
8Supply only Over current and earth fault relay with 50/51 and earth fault protection 50N/51N) , 1A & 5A CT input and auxiliary AC/DC supply 18 to 265V as per existing installed on site complete all as specified and as directed.
9Supply only Under voltage relay Suitable for flush mounting, in temp 0 to 55°C, RH 50% to 100%, 1A & 5A CT input and auxuliary DC supply of 30/110/220V complete all as specified and as directed.
10Supply only Trip Circuit supervision Relay operating on DC supply of 24V as per existing installed on site complete all as specified and as directed.
11Supply only Auxiliary Relay for operating on DC supply of 24V as per existing installed on site complete all as specified and as directed.
12Supply only Over voltage and under voltage relay with 5A CT input and auxiliary AC/DC supply 110V to 265V as per existing installed on site complete all as specified and as directed.
13Supply only PT/VT HRC fuse link with L shape enganging hook in existing clips for 36 KV, rating 2 Amp,breaking capacity 25 kA, as per existing installed on site complete all as specified and as directed.
14Supply only Resin cast/Dry type Potential transformer having 3 phase,Ratio 33000/√3 / 110√3V, burden/class: 100VA/1.0, Fixed type with HRC fuse protection, with IS: 3156-1992 as per existing installed on site complete all as specified and as directed.
15Supply only Resin cast, Dual ratio,Indoor type Current Transformer for breakers having ratio 200-100/5-5A, Burden value 15VA both for protection & metering core, Short-time circuting rating 18.4 kA for 3 sec , Protection Core-2 VA/Class 15/ 5P10 as per existing installed on site complete all as specified and as directed.
16Supply only HRC fuse link type NSD type rating 02 Amps to 10 Amps, Rated voltage 550 V,breaking capacity 80kA as per IS 13703 latest complete all as specified and as directed.
17Supply only HRC fuse link type NSD type rating 16 Amps to 32 Amps, Rated voltage 550 V,breaking capacity 80kA as per IS 13703 latest complete all as specified and as directed.
18Supply only Fuse fitting( front+back+busbar) for LV BS(NSD) type of Fuse FA 20 Amps, Rated voltage 500 V as per IS 13703 latest complete all as specified and as directed.
19M & L for testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 33 KV VCB panel including 33 KV VCB-02 Nos complete all as specified and as directed:-(a)Trip circuit supervision Relay(Auxiliary relay)-02 No(b) Master Trip Relay, 110V DC - 02 No(c) Over current & earth fault relay- 02 No(d) Auxiliary relay for transformer-04 No. (e) Undervoltage relay -02 No. (f) Intelligent Panel Meter- 02 No. (g) Annunciator -01 No. (h) Ammeter & VoltmeterNote: - (I) The tripping system of relays are to be calibrated with MRS,kanasar(II) The tripping timing of the relay to be adjusted less than 33KV system at MRS Kanasar (III) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost(IV) The test shall be provided from authorized agency. Please Enable Macros to View BoQ information
20M & L for testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 33 KV VCB panel including 33 KV VCB-02 Nos complete all as specified and as directed:-(a)Trip circuit supervision Relay(Auxiliary relay)-02 No(b) Master Trip Relay, 110V DC - 02 No(c) Over current & earth fault relay- 02 No(d) Auxiliary relay for transformer-04 No. (e) Undervoltage relay -02 No. (f) Intelligent Panel Meter- 02 No. (g) Annunciator -01 No. (h) Ammeter & VoltmeterNote: - (I) The tripping system of relays are to be calibrated with MRS,kanasar(II) The tripping timing of the relay to be adjusted less than 33KV system at MRS Kanasar (III) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost(IV) The test shall be provided from authorized agency. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58201630
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 26 Lakhs
LAST DATE 14-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of External Electrification Of 33 Kv Network At Mil Stn Kanasar Under Ge (N) Bikaner
Basic Detail
Tender No CA No CWE BKN-Token No 73/2026-2027
Bidding Type Tender
Location
City Bikaner
State Rajasthan
Key Dates
Publish Date 24 Oct 2026
Submission Date 14 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 26 Lakhs
Tender Fee 500
EMD 52000
Exemption Available
Document List
834c9ceb-1f08-48ca-b49d-879858ed6cab.html
BOQ_892231.xls
Tender73.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

834c9ceb-1f08-48ca-b49d-879858ed6cab.html

xls

BOQ_892231.xls

pdf

Tender73.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender