Tender For Repair/Maintenance Of External Electrification Of 33 Kv Network At Mil Stn Kanasar Under Ge (N) Bikaner
Tender Value
26 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
2 days left
EMD
52000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of External Electrification Of 33 Kv Network At Mil Stn Kanasar Under Ge (N) Bikaner
BOQ
| Sl. No. | Item Description |
| 1 | M&L for preventive maintenance / repairing by opening and taking out the Vacuum Circuit Breaker (VCB) /33 KV 800/1250 Amp and carry out the general maintenance such as oiling & greasing the mechanical parts, motor, gear, lever spring, operating rod, cleaning the female contacts, tightening of nuts and bolts, cleaning the male and female contact of panel, oiling the bus bar shutter, checking the AC/DC wiring, circuit including control fuses and circuit jack, on/off push button, indicating lamp, voltmeter, ammeter, PF meter, replacement of minor parts (where required) and testing after re-inserting the VCB in panel complete all as specified and as directed. The new replaced parts shall be measured and paid separately under appropriate item(i.e. 2 to 5) of Sch 'A' as supply only. |
| 2 | Supply only Anti Pumping Relay should not be plug in type & should have suffcient number of contact as per existing installed on site complete all as specified and as directed. |
| 3 | Supply only Tripping coil having copper material through actuating device rated for Substation DC voltage 12/ 24 /110 V ,burden value < 200 watt , Min operating Voltage of 70% for tripping and 85% for closing operation as per existing installed on site complete all as specified and as directed. |
| 4 | Supply only Closing coil having copper material through actuating device rated for Substation DC voltage 12/ 24 /110 V ,burden value < 200 watt,, Min operating Voltage of 70% for tripping and 85% for closing operation as per existing installed on site complete all as specified and as directed. |
| 5 | Supply only Spring charging motor operated on Power 150-250 Watts ,220 V AC/DC supply having insulation Class B type as per existing installed on site complete all as specified and as directed. |
| 6 | M&L for replacing unserviceable parts of 33 KV transformer control panel and Vacuum Circuit Breaker (VCB) 33 KV include testing all parts after replacing and changing faulty wiring complete all as specified and as directed. The new replaced parts shall be measured and paid separately under appropriate item(i.e. 7 to 18) of Sch 'A' as supply only. |
| 7 | Supply only Electromechanical Master trip relay Hand reset type Suitable for flush mounting and auxiliary DC supply of 24V as existing Make complete all as specified and as directed. |
| 8 | Supply only Over current and earth fault relay with 50/51 and earth fault protection 50N/51N) , 1A & 5A CT input and auxiliary AC/DC supply 18 to 265V as per existing installed on site complete all as specified and as directed. |
| 9 | Supply only Under voltage relay Suitable for flush mounting, in temp 0 to 55°C, RH 50% to 100%, 1A & 5A CT input and auxuliary DC supply of 30/110/220V complete all as specified and as directed. |
| 10 | Supply only Trip Circuit supervision Relay operating on DC supply of 24V as per existing installed on site complete all as specified and as directed. |
| 11 | Supply only Auxiliary Relay for operating on DC supply of 24V as per existing installed on site complete all as specified and as directed. |
| 12 | Supply only Over voltage and under voltage relay with 5A CT input and auxiliary AC/DC supply 110V to 265V as per existing installed on site complete all as specified and as directed. |
| 13 | Supply only PT/VT HRC fuse link with L shape enganging hook in existing clips for 36 KV, rating 2 Amp,breaking capacity 25 kA, as per existing installed on site complete all as specified and as directed. |
| 14 | Supply only Resin cast/Dry type Potential transformer having 3 phase,Ratio 33000/√3 / 110√3V, burden/class: 100VA/1.0, Fixed type with HRC fuse protection, with IS: 3156-1992 as per existing installed on site complete all as specified and as directed. |
| 15 | Supply only Resin cast, Dual ratio,Indoor type Current Transformer for breakers having ratio 200-100/5-5A, Burden value 15VA both for protection & metering core, Short-time circuting rating 18.4 kA for 3 sec , Protection Core-2 VA/Class 15/ 5P10 as per existing installed on site complete all as specified and as directed. |
| 16 | Supply only HRC fuse link type NSD type rating 02 Amps to 10 Amps, Rated voltage 550 V,breaking capacity 80kA as per IS 13703 latest complete all as specified and as directed. |
| 17 | Supply only HRC fuse link type NSD type rating 16 Amps to 32 Amps, Rated voltage 550 V,breaking capacity 80kA as per IS 13703 latest complete all as specified and as directed. |
| 18 | Supply only Fuse fitting( front+back+busbar) for LV BS(NSD) type of Fuse FA 20 Amps, Rated voltage 500 V as per IS 13703 latest complete all as specified and as directed. |
| 19 | M & L for testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 33 KV VCB panel including 33 KV VCB-02 Nos complete all as specified and as directed:-(a)Trip circuit supervision Relay(Auxiliary relay)-02 No(b) Master Trip Relay, 110V DC - 02 No(c) Over current & earth fault relay- 02 No(d) Auxiliary relay for transformer-04 No. (e) Undervoltage relay -02 No. (f) Intelligent Panel Meter- 02 No. (g) Annunciator -01 No. (h) Ammeter & VoltmeterNote: - (I) The tripping system of relays are to be calibrated with MRS,kanasar(II) The tripping timing of the relay to be adjusted less than 33KV system at MRS Kanasar (III) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost(IV) The test shall be provided from authorized agency. Please Enable Macros to View BoQ information |
| 20 | M & L for testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 33 KV VCB panel including 33 KV VCB-02 Nos complete all as specified and as directed:-(a)Trip circuit supervision Relay(Auxiliary relay)-02 No(b) Master Trip Relay, 110V DC - 02 No(c) Over current & earth fault relay- 02 No(d) Auxiliary relay for transformer-04 No. (e) Undervoltage relay -02 No. (f) Intelligent Panel Meter- 02 No. (g) Annunciator -01 No. (h) Ammeter & VoltmeterNote: - (I) The tripping system of relays are to be calibrated with MRS,kanasar(II) The tripping timing of the relay to be adjusted less than 33KV system at MRS Kanasar (III) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost(IV) The test shall be provided from authorized agency. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender