Tender For Provn Of Shifting Of Transformer And Lt Panels At Echs At Jaipur Mil Stn
Tender Value
6.96 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
2 days left
EMD
13920
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Shifting Of Transformer And Lt Panels At Echs At Jaipur Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ 82608/E8 BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE JAIPUR Name of Work: PROVN OF SHIFTING OF TRANSFORMER AND LT PANELS AT ECHS AT JAIPUR MIL STN CA NO: CWE/JPR(S)- OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # SNo Item Description Item Code / Make Qty Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figure Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes Rate in Words Total Amount |
| 2 | M&L for shifting of 200 KVA transformer from one location to another location within the ECHS area of disconnecting of all connection and connecting with HT 11 KV incomer from existing source and LT outgoing cables complete as directed by Engineer-in-Charge. |
| 3 | M&L for shifting of LT Panel from one location to another location ECHS area including making all electrical connections as well as PCC foundation complete all as specified and directed by Engr-in-Charge.Note:- Excavation & related earth work shall deemed to be inclusive of quoted rates. |
| 4 | Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing complete all as specified and directed of size 95 Sqmm, 3 core cable including taking down/dismantling old item complete all as specified and directed. |
| 5 | Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanized steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc size 185 Sqmm 3.5 core complete all as specified and directed. |
| 6 | Description all as per Item No 4.00 above but size 95 Sqmm. |
| 7 | Description all as per Item No 4.00 above but size 50 Sqmm. |
| 8 | Description all as per Item No 4.00 above but size 35 Sqmm. |
| 9 | Description all as per Item No 4.00 above but size 25 Sqmm 4 core. |
| 10 | M&L for cable end termination, jointing kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade complete all as specified and directed of size 95 Sqmm x 3 core complete all as specified and directed. |
| 11 | Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm, Indoor / Outdoor type complete all as specified and directed. |
| 12 | Description all as per Item No 10.00 above but size 70 to 95 Sqmm. |
| 13 | Description all as per Item No 10.00 above but size 120 to 150 Sqmm. |
| 14 | Supply and fixing heat shrinkable end jointing kit complete with accessories suitable for XLPE armoured aluminium conductor cable 1.1 KV grade of size 10 - 35 Sqmm 3.5 Core complete all as specified and directed. |
| 15 | Description all as per Item No 13.00 above but size 50 - 70 Sqmm 3.5 Core. |
| 16 | Description all as per Item No 13.00 above but size 95 - 150 Sqmm 3.5 Core. |
| 17 | Disconnecting and dismantling of existing 2/4 pole structure and connecting all cable in RMU complete all as specified and directed. |
| 18 | Supply & fixing Air break switch 200 amp, for HT 11 KV, 50 Hz AC, Gang Operated, triple pole, outdoor, horizontal / vertical mounting type (ISI marked), mounted on insulators and MS frame work, with fuse carriers & HT fuses, manually operated from ground level with locking arrangement including 65 mm pad lock with two keys, necessary electric connections, taking down old item complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fixing lightening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 11000 volts complete all as specified and directed. |
| 20 | S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 21 | M&L for earthing with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanized iron or steel earth strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanized iron or steel. Earthing strip shall be protected by galvanized iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cove with handle complete all as specified & tested complete as per electrical plate No. 3 of MES SSR Part-I complete all as specified and directed. |
| 22 | M&L earthing with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanized iron or steel earth wire 4 mm by means of bolts, nuts check nuts and washers of galvanized iron or steel. Earthing strip shall be protected by galvanized iron or steel pipe 15mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cove with handle complete all as specified & tested complete as per electrical plate No. 3 of MES SSR Part-I complete all as specified and directed. |
| 23 | Supply & fixing LT/HT cable route indicator cast iron of suitable size along LT/HT cable trench including painting and grouted in ground in PCC complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for VTPN DB 6 way, Double door type, 415 volts, wall mounting vertical three phase pre wired distribution boards made out of CRCA steel sheets. Phosphatised powder coated, with copper bus bar, earth stud , DIN rail , poly made terminal blocks for incoming and outgoing circuits, inbuilt loose wire box , ground terminal blocks, duly pre wired with thimbled flame retardant copper conductors and poly layer for protection of MCCB and MCBs complete. Sheet metal enclosure IP 43, 200 amps rated busbar including all connections complete all as specified and directed. |
| 25 | S&F MCCB from panel and S&F new MCCB 160 amp, 36 KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase, adjustable type including extension terminals and Ics=100%Icu connecting using suitable fasteners, modification/fabrication if any complete all as required at site, complete all as specified and directed. |
| 26 | Description all as per Item No 24.00 above but 200 amp, 36 KA. |
| 27 | Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning TPN/FP 40 to 100 AMP complete all as specified and directed. |
| 28 | Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil complete all as specified and directed. |
| 29 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth complete all as specified and directed. |
| 30 | Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point complete all as specified and directed. |
| 31 | M & L for Sand cushioning to under ground cable with stone crushed sand and punning to provide a required cover complete all as specified and directed. |
| 32 | Supply and laying un-reinforced precast cable covers class LV, type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 33 | Supply and laying tube GI light grade of 50 mm bore in trenches/ road crossings/ floor/poles/walls etc. with all fittings for protection of cable complete all as specified and directed. |
| 34 | Description all as per Item No 33.00 above but size 100 mm bore. |
| 35 | Supply, install, commissioning and testing factory made and tested CPRI type test certified) LT Panel out door type, floor mounted, compartmentalized suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :-(a) MCCB 320 amps, 4 pole, 50 KA with adjustable thermal release, 50 Hz, 415 volts grade - 01 No.(b) Bus bar electrolytic grade copper of rating 1.5 times of MCCB/ACB and supported on Non-hygroscopic, non carbonizing, corrosion resistance SMC insulators 4 pole - 01 set.(c) Digital volt and ammeter with selector switch and CT's set - 01Set. (d) LED indicating lamps (R, Y & B) -01 Set.Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level.(iii) Outgoing Cables shall be fed with solid busbar connectors.(iv) Cables shall be terminated using gun metal /SS glands. |
| 36 | Schedule of Credit Total in Figures 0.0 0.0 -8000.0 Quoted Rate in Figures Select 0.0 0.0 Zero Only 0.0 Quoted Rate in Words INR Minus Eight Thousand Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender