Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #58201552

Tender For Repair / Maintenance Of Internal Electrification , Maintenance Of Acs, Water Cooler, Geyzer Etc And Repair/ Maintenance Of External Electric Supply At Icgae Porbandar Under Ge (I) Cg Porbandar

Issued by Statutory Bodies & Commissions/Committees · Porbandar, Gujarat
Tender Value
21 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
12 days left
EMD
42000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Porbandar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Internal Electrification , Maintenance Of Acs, Water Cooler, Geyzer Etc And Repair/ Maintenance Of External Electric Supply At Icgae Porbandar Under Ge (I) Cg Porbandar

BOQ

Name of Work:- REPAIR / MAINTENANCE OF INTERNAL ELECTRIFICATION , MAINT OF Acs, WATER COOLER, GEYZER ETC AND REPAIR/ MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY AT ICGAE PORBANDAR UNDER GE (I) CG PORBANDAR
Sl. No. Item Description
1Schedule 'A'
2Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc to be measured and paid for seprately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc complete all as spd and as directed.
3Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces inclduing painting , complete all as spd and as directed
4Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire Excluding modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc complete all as spd and as directed for the following:-
5One light/ Bulb Holder /fan/exhaust point one way switch
6One light point controlled by 2, Two way switch
7One 5 pin socket outlet 5/6 amps on the same board.
8One 5 pin socket oulet 5/6 amps on independent board..
9One bell point controlled by one, one way switch
10Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire excluding modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
11One 16 A socket outlet, independent, with cables 2.5 mm² size
12Supply and fixing of in replacement of modular type 6 A one-way SP switch, conforming to IS: 3854-2023 with finger proof terminal complete as specified and directed.
13Supply and fixing of replacement of modular type 16 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete as specified and directed .
14Supply and fixing of replacement of modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293- 2008 complete as specified and directed.
15Supply and fixing of replacement of modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293- 2008 complete as specified and directed.
16Supply and fixing of replacement of modular type 6 A bell-push conforming to IS: 3854-2023 with finger proof terminal complete all as specified and directed.
17Supply and fixing of replacement of Bell multi music type 230 Volt complete as specified and directed.
18Supply and fixing of in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984 complete as specified and directed.
19Supply and fixing of in replacement of 6 A, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm complete all as specified and directed.
20Supply and fixing of in replacement of Modular switch 2 way 6A, 1 module complete all as specified and as drirected
21Supply and fixing in replacement of Modular Flush boxes of following size complete all as specified and as directed
221 or 2 Module Metal flush box complete all as specified.
233 Module Metal flush box complete all as specified.
244 Module Metal flush box complete all as specified.
256 Module Metal flush box complete all as specified.
26Supply and fixing in replacment of Modular cover plate with frame of following size complete all as specified and as directed
271 or 2 Module Modular cover plate with frame of size 85x 85 mm
283 Module Modular cover plate with frame of size 85x 115 mm
294 Module Modular cover plate with frame of size 85x 145 MM
306 Module Modular cover plate with frame of size 132x 135 mm
31Supply and fix in replacement of following items for maintenance of Internal Electrification , complete all as specified and directed by Engr-in-Charge.
32Switch piano, flush type single pole, one way 5 Amp
33Socket Outlet 2 in 1, 3 pin, 6A
34Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type
35Switch piano, flush type single pole, one way 15 Amp
36Switch socket combination, 6 Amps flush type.
37Switch socket combination, 16 Amps flush type.
38Lamp holder plug for Batten fitting.
39Bell push, flush type 5 Amp.
402.5 mfd Capacitor
41Stepped type electronic fan regulator
42Top plug 5 Amp complete all as specified and directed.
43Top plug 15 Amp complete all as specified and directed.
44Supply and fixing of in replacement of MCB DB sheet enclosure double door type flush type/surface mounted, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, complete all as specified and directed by Engr-in-Charge.
45Supply and fixing of in replacement of MCB DB sheet enclosure double door type flush type/surface mounted, triple pole and neutral 415V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 6 way type, complete all as specified and directed by Engr-in-Charge.
46Supply and fixing in replacement of MCB of following size complete all as specified and as directed
47MCB 'C' curve 6 to 32Amps single pole, 240V of rupturing capacity 10KA
48MCB 'C' curve 32Amps double pole / SPN, 240 V of rupturing capacity 10KA
49MCB 'C' curve 40 -63 Amps double pole / SPN, 240 V of rupturing capacity 10KA
50Supply and fixing in replacement of 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed by Engr-in-Charge.
51MCB, TP 25 to 63Amps
52MCB, TPN/FP 16 to 32Amps
53M & L for submain wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size in exsisting conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, all complete as specified and directed. Make: RR Kabel, Polycab, Havells, Finolex (HR-FR flexible cable) & Precision, Prince, Supreme NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length.
542 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire
552 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire
56Supply and fixing in replacement of of casing capping of 25x 12 mm size complete all as specified and as directed.
57Supply and fixing in replacement of of casing capping of 32x16 mm size complete all as specified and as directed.
58Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engr-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
59Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding and same nos of turns with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge.
60Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire and same nos of turns with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge.
61Dismantling of BLDC fan (1200mm sweep) motor, taking out unserviceable PCB and replace with new PCB as per existing make and reassembling , complete all as specified and directed by Engr-in-Charge..
62Dismantling of Exhaust fan Plastic Body 250/300mm motor, and replace with new motor and reassembling , complete all as specified and directed by Engr-in-Charge.
63Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engr-in-Charge.
64Supply and fix exhaust fan made of steel body, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm, complete all as specified and directed by Engr-in-Charge.
65Supply & fix Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting including mounting accessories complete.
66Supply and fixing of in replacement of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed.
67Supply and fixing of in replacement of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed.
68Supply and fixing of in replacement of LED Luminaires recessed mounted square/round down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires complete all as specified and as directed by Engineer-in-Charge.
69Supply and fixing of in replacement of RGB/Multicolour fountain light LED 9W, IP 68, Aluminium die cast housing with purity lense for spot lightning with glare free light distrubition enhancing accent lighting, including fixing arrangements, S Connector & T Connectors etc complete all as specified and directed.
70Supply and fixing of in replacement of square shape slim recessed mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating complete all accessories as specified and directed .
71Supply and fixing of in replacement of LED wall light 2x 6 Watts (2700K) and including connected with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fitting in position at site all as specified and directed.
72Supply and fixing of in replacement of LED decorative Wall mounted fancy Light, Lamp base 1 x E27 type, 7.5 Watts LED Lamp with matt gold finish with borosil glasstype and with high illumination indoor wall light LED, including fixing arrangements etc complete all as specified and directed.
73Supply and fixing of in replacement of warm white LED picture light fitting Bronze body finish with flexible neck for adjustment beam, 12 Watt and including connected with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site all as specified and directed.
74Supply and fixing of in replacement of LED Bollard Light Cool White of wattage 11 Watt 6500 K with with integrated mounting base plate and driver complete with housing dark grey RAL 7043 IP 65 protection, Resistant to corrosion and Better optics for uniform distribution including PCC (1:2:4) foundation of suitable size for mounting of light fitting complete all as specified and directed.
75Supply and fixing in replacement of post top lantern LED type 40 watt 230 volts AC outdoor type(Warm/Cool White) with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
76Supply and fixing of in replacement of wall/surface mounted LED Bulk head of capacity 10 Watt IP 65 Protection complete all accessories as specified and directed .
77Supply and fixing of in replacement of surface mounted LED hanging light 20 W 4000K with die cast housing finished in white powder coating complete all accessories as specified and directed .
78Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ , complete all as specified and directed by Engr-in-Charge. Note- worn out parts shall be measured as separately.
79Supply & Fixing of spare parts for Geyser
80Heating element 1.5 KW with rubber gasket.
81Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
82Hot/Cold water connection pipe 450 mm length.
83Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia
84Indication lamp red and green suitable for geyser as required
85M & L for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush , refixing the front cover of indoor unit . Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressureized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection Complete all as specified and directed by Engr-in-Charge.Note - Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule. Please Enable Macros to View BoQ information
86M & L for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush , refixing the front cover of indoor unit . Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressureized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection Complete all as specified and directed by Engr-in-Charge.Note - Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58201552
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 21 Lakhs
LAST DATE 14-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Internal Electrification , Maintenance Of Acs, Water Cooler, Geyzer Etc And Repair/ Maintenance Of External Electric Supply At Icgae Porbandar Under Ge (I) Cg Porbandar
Basic Detail
Tender No 8240A/E8
Bidding Type Tender
Location
City Porbandar
State Gujarat
Key Dates
Publish Date 24 Oct 2026
Submission Date 14 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 21 Lakhs
Tender Fee 500
EMD 42000
Exemption Available
Document List
8240AT.pdf
BOQ_892321.xls
c136c537-5f30-431d-918f-c93ddbb2f722.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

8240AT.pdf

xls

BOQ_892321.xls

html

c136c537-5f30-431d-918f-c93ddbb2f722.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender