Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58201549

Tender For Repair/Maint/Replacement Of Lt And Ht Electric Distribution System,Panels,Cables All Type Of Lt Switchgears,Street Lights And Other Allied Works At Cqa (A) & Sqae Of Age E/M Ii Under Ge (C) Khadki.

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
45.77 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
20 days left
EMD
91540
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint/Replacement Of Lt And Ht Electric Distribution System,Panels,Cables All Type Of Lt Switchgears,Street Lights And Other Allied Works At Cqa (A) & Sqae Of Age E/M Ii Under Ge (C) Khadki.

BOQ

Name of Work:- REPAIR/MAINT/REPLACEMENT OF LT AND HT ELECTRIC DISTRIBUTION SYSTEM,PANELS,CABLES ALL TYPE OF LT SWITCHGEARS,STREET LIGHTS AND OTHER ALLIED WORKS AT CQA (A) & SQAE OF AGE E/M II UNDER GE (C) KHADKI.
Sl. No. Item Description
1Dismantling and taking down old unserviceable any type of street light/flood light/post top/bollard light of any capacity complete all as specified & directed by Engineer-in-Charge.
2Dismantling and taking down old unserviceable MCB/MCCB/change over switch and switchgears of any type and capacity complete all as specified & directed by Engineer-in-Charge.
3Dismantling and taking down of old unserviceable driver of light fitting of any type and capacity complete all as specified & directed by Engineer-in-Charge.
4Taking down old unserviceable service wire of any size and any type complete all as specified & directed by Engineer-in-Charge.
5S&F LED Street light 45W With inbuilt Driver with surge protection with 5kV internal and 10kv external having Pressure die cast Aluminium housing with toughned glass primary optics with lens, IP-66 Having Efficiency of ≥ 120 Lumens/Watt, Operating voltage – 140 – 280 Volts, P.F ≥ 0.95, T.H.D < 10 % including making electrical connection to the fitting with Suitable size of service wire complete all as specified & directed by Engineer-in-Charge.
6S&F LED Street light 60W With inbuilt Driver with surge protection with 5kV internal and 10kv external having Pressure die cast Aluminium housing with toughned glass primary optics with lens, IP-66 Having Efficiency of ≥ 120 Lumens/Watt, Operating voltage – 140 – 280 Volts, P.F ≥ 0.95, T.H.D < 10 % including making electrical connection to the fitting with Suitable size of service wire complete all as specified & directed by Engineer-in-Charge.
7S&F LED Street light 90W With inbuilt Driver with surge protection with 5kV internal and 10kv external having Pressure die cast Aluminium housing with toughned glass primary optics with lens, IP-66 Having Efficiency of ≥ 120 Lumens/Watt, Operating voltage – 140 – 280 Volts, P.F ≥ 0.95, T.H.D < 10 % including making electrical connection to the fitting with Suitable size of service wire complete all as specified & directed by Engineer-in-Charge.
8S&F LED Flood light 100W IP-66, LUMEN EFFICACY >= 110lm/W , OPERATING VOLTAGE RANGE 140 – 280, P.F > 0.95 , CCT – 5700K, SURGE PROTECTOR 5kV inbuilt and 10 KV external having Pressure die cast Aluminium housing with toughned glass primary optics with lens, fitting including making electrical connection to the fitting with Suitable size of service wire complete all as specified & directed by Engineer-in-Charge.
9S&F LED Flood light 120W IP-66, LUMEN EFFICACY >= 110lm/W , OPERATING VOLTAGE RANGE 140 – 280, P.F > 0.95 , CCT – 5700K, SURGE PROTECTOR 5kV inbuilt and 10 KV external having Pressure die cast Aluminium housing with toughned glass primary optics with lens, fitting including making electrical connection to the fitting with Suitable size of service wire complete all as specified & directed by Engineer-in-Charge.
10S&F LED Post top luminaries 40w decorative post top for 360 degree indirect light fixing on existing pole with all necessary fixing arrangement and all accessories prewired including connecting up with twin core copper conductor cable with suitable size complete all as specified & directed by Engineer-in-Charge.
11S&F LED bollard light fittings, LED 10Watt, all including fixing material and earth work complete and connected to nearest electric pole complete all as specified & directed by Engineer-in-Charge.
12S&F in replacement of street light mounting bracket, made out of Light grade GI Tubing 32 mm bore , bend into shape inner angle not less than 120° and over all length not less tan 1.0 Mtr including suitable size clamps made from not less than 25x3 mm ms strip , Nut, bolts 12 mm dia with washers complete fixing arrangement complete all as specified & directed by Engineer-in-Charge.
13Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surface & sides to required slope/size complete all as specified & directed by Engineer-in-Charge.
14M&L for sand/fine dust cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified & directed by Engineer-in-Charge. Note : punning thickness of 18 cm will be measured for payment
15Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified & directed by Engineer-in-Charge.
16Supply & laying un-reinforced precast concret cable cover class HV type 1, flat size 300mm x 180mm x 40 mm complete all as specified & directed by Engineer-in-Charge.
17Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil complete all as specified & directed by Engineer-in-Charge.
18Removal of surplus soil to a distance not exceeding 50 m and depositing where complete all as specified & directed by Engineer-in-Charge.
19Taking up/down old unserviceable HT/LT cable PVC/XLPE insulated any type any size complete all as specified & directed by Engineer-in-Charge.
20Supply and Lay of LT underground cable XLPE insulated armoured heavy duty 1100 Volts grade with aluminium conductor multistranded including centre glands/lugs/jointing materials etc..laid in trench or fixed it to wall connecting testing and commissioning complete for the following sizes:
21All as per item No. 20 above for 10 Sqmm 4 core
22All as per item No. 20 above for 16 Sqmm 4 core
23All as per item No. 20 above for 25 Sqmm 3.5 core
24All as per item No. 20 above for 35 Sqmm 3.5 core
25All as per item No. 20 above for 50 Sqmm 3.5 core
26All as per item No. 20 above for 70 Sqmm 3.5 core
27All as per item No. 20 above for 95 Sqmm 3.5 core
28All as per item No. 20 above for 120 Sqmm 3.5 core
29Supply,laying ,testing & commissioning of XLPE insulated , screened, PVC bedded , galvanised steel strip or wire armoured , electric power cable (Heavy duty) with alluminium conductor, cross sectional area 95 sqmm 3 core 11000 Volts HT grade complete all as specified & directed by Engineer-in-Charge.
30S&F PVC sheathed 1100V grade flat three core stranded aluminium conductor of size 2.5 sqmm including conduit pipe connecting from SMC box to street light fitting complete all as specified & directed by Engineer-in-Charge
31M&L for earthing in replacement complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick electrode and 32 mm x 6 mm GI strip as earthing lead buried directly in ground (earth pit not less than 2.25 meters deep below ground level )with top edge of the plate not less than 1.5 meters below normal ground level ,connected to galavanised GI strip 32 mm x 6 mm by means of bolts,nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate no 03 connected to earthing test point all as specified or indicated includind testing on completion including testing complete all as specified & directed by Engineer-in-Charge. NOTE: IF the desired result not obtained after testing the contractor should do re-eathing without any extra cost.
32S&F in replacement 40 mm bore GI tubing light grade in trenches or on pole for cable protection complete all as specified & directed by Engineer-in-Charge.
33M & L Aluminum lugs eye lid or barrel type complete with cripping/soldering etc including removing the wornout lugs suitable for aluminium cables/copper cables of sizes from 16 Sqmm to 95 Sqmm complete all as specified & directed by Engineer-in-Charge complete all as specified & directed by Engineer-in-Charge
34M & L Aluminum lugs eye lid or barrel type complete with cripping/soldering etc including removing the wornout lugs suitable for aluminium cables/copper cables of sizes from 95 Sqmm to 150 Sqmm complete all as specified & directed by Engineer-in-Charge Please Enable Macros to View BoQ information
35M & L Aluminum lugs eye lid or barrel type complete with cripping/soldering etc including removing the wornout lugs suitable for aluminium cables/copper cables of sizes from 95 Sqmm to 150 Sqmm complete all as specified & directed by Engineer-in-Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58201549
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45.77 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint/Replacement Of Lt And Ht Electric Distribution System,Panels,Cables All Type Of Lt Switchgears,Street Lights And Other Allied Works At Cqa (A) & Sqae Of Age E/M Ii Under Ge (C) Khadki.
Basic Detail
Tender No CWE/KKE/TOKEN- 52 OF 2026-27
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 24 Oct 2026
Submission Date 18 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 45.77 Lakhs
Tender Fee 500
EMD 91540
Exemption Not Available
Document List
aac6dfc5-0604-4ccf-99c5-4e5346b3e8df.html
BOQ_892332.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

aac6dfc5-0604-4ccf-99c5-4e5346b3e8df.html

xls

BOQ_892332.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer