Tender For Provn Of 100 Kva Transformer With Connected Cable Works At Urc At Clement Town Dehradun
Tender Value
9.64 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
6 days left
EMD
19288
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of 100 Kva Transformer With Connected Cable Works At Urc At Clement Town Dehradun
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying, testing and commisioning HT underground cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire aromoured electric power cables (heavy duty) with aluminium stranded condutor served with an inner sheathing of PVC tape armoured with galvanized steel strip and overall PVC sheathed 11000 volts grade (earthed) of cross sectional area of size 95 sq mm 3 core complete all as specified and directed. |
| 2 | Supply & erecting in truely vertical position steel tubular swaged poles 410 SP-55 (11.00 mtrs long) complete with 300 x300x 6 mm thick MS base plate continuously welded at bottom of pole and MS sheet 2 mm thick plug welded at top, bolts, nuts & screws including one shop coat of red oxide primer and internally bituminous painted including painting with two coats of aluminium paint and black and white strips 30 cm upto 1.5mtr height from top of coping in strips and anti climbing device complete all as specified and directed. (Earth work & PCC shall be measured & paid for separately). |
| 3 | Supply and fixing lightning arresters HT 11 KV, 10 KA station class complete all as specified and directed. |
| 4 | M&L for danger notice board/plate of 1.6mm thick mild steel sheet , vitreous enamelled white with letters, figures , and conventional skull and bone in signal red colour and fixed with MS clamps bolts and nuts of approved size of HT 25cmx20 cm complete all as specified and directed. |
| 5 | M&L anti climbing device, spikes type, fabricated out of MS bars (round, square or flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the poles, spike welded to flat iron, including one primer coat, one under coat and two finishing coats of silver aluminium paint including preparation of surfaces, complete all as specified and as directed. |
| 6 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron earth lead 4mm dia size by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with RCC cover in cement concrete 1:2:4 Type B1 (20mm graded aggregate), funnel, wire mesh, charcoal dust, salt layers each layer thickness should be 15 cm (layer start from below the electrode plate to above plate) etc, including testing complete all as specified and as directed. |
| 7 | M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by charcoal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth strip of 32x6 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 15mm dia GI pipe for protection of GI earth strip including 20mm dia GI pipe for watering GI funnel , PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing complete all as specified and directed. |
| 8 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm.complete all as specified and directed. |
| 9 | M&L for Cross arms, bracing ,supports clamps and back plates fabrication from structural steel sections including nuts, bolts, washers ,welding, bending cold or hot drilling holes for bolts, in any shape including one primer coat ,one under coat and one finishing coat complete all as specified and directed. |
| 10 | Supply and fix HT 11 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complete with drop out fuse having 12 insulators of rating upto 200 Amps complete all as specified and directed. |
| 11 | Supply, installation, testing and commissioning of transformer step down outdoor type copper wound , oil cooled IP-43 plinth mounted powder coated capacity 100 KVA CL-I with latest feature complete with standard fitted HT 11 KV 3 Phase LT 433 V 3 phase 4 wire, 50 C/S oil immersed naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433 V with tapping at +/- 2.5% to +/- 5% & +/- 7.5% on HV side and to be charged by means of hand operated off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with all fiiting and accessories such as LT box at LT side,silica gel,brather, oil level indicator, conservator tank with oil level indicator,drain out valve (oil tank), exhaust vent,air release valve, temp gauge and cast iron wheel etc complete Level-2 as per IS-1180(Part-1):2014, complete all as specified and directed. |
| 12 | M & L for contruction of foundation for transformer as per OEM standard of size 2.50 M X 2.50 M X 1.20M height including necessary brick work, filling and mass concrete of type B2 1:2:4 (using 40mm graded stone aggregate) filling on top surface 60 mm thick complete all as specified and as directed. |
| 13 | M&L for LT panel box size (1.5X1.2X0.6 mtr) outdoor type having thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 complete all as specified and directed. |
| 14 | Incoming :- (a) MCCB , 200 Amps, 4P, 415V,25KA - 01 Each, Al busbar of capacity 315 Amps - Set of three. |
| 15 | Outgoing :- (a) MCCB , 100 Amps, 4P, 415V,25KA - 03 Each, |
| 16 | a) Multi Functional digital meter (A/V/PF/F) , CT Coils of suitable ratioas suitable size-01 Set. |
| 17 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed. |
| 18 | All as per Description Srl Item No 14 above but size 70 sqmm 3.5 core complete all as specified and directed. |
| 19 | All as per Description Srl Item No 14 above but size 35 sqmm 3.5 core complete all as specified and directed. |
| 20 | Excavating in trenches n'exc 1.5 m width and n'exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 21 | Description all as per srl item No -17 above but depth exceeding 1.5 m but not exc 3.0 m complete all as specified and directed. |
| 22 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 23 | Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point complete all as specified and directed. |
| 24 | Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak size 300 mm x 180 mm x 40 mm complete all as specified and directed. |
| 25 | Supply, laying and fixing HDPE pipe for protection for power cable of size 63 mm dia complete with joint fittings and including cutting, jointing and clamping complete all as specified and directed. |
| 26 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose. |
| 27 | M&L cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for coping of pole etc complete all as specified and directed. |
| 28 | M&L cement concrete 1:3:6 type C2 using 40mm graded stone aggregate complete all as specified and directed. |
| 29 | M&L cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for pole foundation complete all as directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender