Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #58201540

Tender For Special Repair To 16 Rolling Shutter Of Sheds Including Electrification And Masonry Work At Patiala Under Ge(S) Patiala.

Issued by Statutory Bodies & Commissions/Committees · Patiala, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Nov 2026
11 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To 16 Rolling Shutter Of Sheds Including Electrification And Masonry Work At Patiala Under Ge(S) Patiala.

BOQ

Name of Work:- SPECIAL REPAIR TO 16 ROLLING SHUTTER OF SHEDS INCLUDING ELECTRIFICATION AND MASONRY WORK AT PATIALA UNDER GE(S) PATIALA.
Sl. No. Item Description
1'Notes: (i) Please refer Schedule 'A' Notes of tender documents.
2Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good to disturbed surfaces complete incl ventilators including reqd shape for hold fast block for new frame complete all as specified and directed.
3Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed
4S&F door frames made of PPGI sheet of 1.20 mm thickness for doors and windows with one or more rebates including necessary fixing lugs, lock strike plate, hold fast etc., complete all as specified, size 125 x 60mm and incl cutting holes and making good reqd shape for hold fast block for new frame incl complete all as specified and directed.Note : Mullions and Transom will be measured and paid for each side separately.
5M&L for cement concrete (1:2:4) using 12.50 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats, hold fasts etc., complete all as specified and directed.
6S&F 35mm thick glazed and skelton shutters of 2nd class hard wood as in windows/ventilators open rebated and divided to receive glass, gauze etc divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part I, Section 8, clause 8.24 (b);, kiln seasoned and chemically pressure treated complete all as specified and directed.Note : Glass or wire cloth, etc. in panels or sash squares shall be measured separately.
7S&F window grill of stainless steel 304 Grade of hollow sections as approved fixed to window/ door frames complete all as specified and directed.
8Preparing new wooden surfaces and applying two coats of synthetic enamal paint over one coat of pink wood primer complete all as specified and directed.
9S&F 5 mm thick clear toughened glass for glazing works etc fixed with aluminium beads/uPVC windows any size of pane complete all as specified and directed
10Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
11S&F stainless steel finished 202 Grade butt hinges 100mm long complete all as specified and directed.
12S&F stainless steel finished 100mm long tower bolts in square shaped with minimum 10mm dia rod complete all as specified and directed.
13S&F Stainless Steel finished curved/square/ any other shape as approved Handles 150 mm long complete all as specified and directed.
14Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed.
15M&L Brick work with Fly ash bricks minimum class designation 100 straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 complete all as specified and directed.
16Taking down cement plaster of any description, any thickness from external/Internal surfaces of walls/soffits/ceilings etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed.
17M&L for Cement plastering 15mm thick in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair without using extra cement complete all as specified and directed.Note : WPC will be measured and paid separately.
18Supply only integral liquid water proofing compound complete all as specified and directed.
19M&L for 10mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
20M&L for 5 mm thick cement plastering in cement mortar 1:3 on fair faces of concrete ceiling surfaces finished fair & even without using extra cement complete all as specified and directed.
21M&L for demolition of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, benching,coping and similar work complete all as specified and directed
22Repair to RCC ceiling, sunshades, Chajjas, Balconies, Columns, bands, beams, roof slab and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
23Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder complete all as specified and directed.
24M&L for preparing new plastered surfaces of walls and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and directed.
25M&L for preparing new plastered surfaces of ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and directed.
26M&L for preparing existing treated surfaces of walls including cornices and applying two coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed.
27M&L for preparing existing treated surfaces of ceilings including cornices and applying two coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed.
28M&L for preparation of surfaces of external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc and applying two coat of cement base paint with highlighter of any approved shade @ 5 sq.m/kg/1 coat or as recommended by the manufacturer of cement based paint by using following brands of cement based paint using brush or roller complete all as specified & as directed.
29M&L for Applying two coats of oll bound distamper white or tinted, over and including a coat of primer including preparation of plastered Surfaces of wall complete all specified and directed.
30Dismantling carefully MS or wrought iron work as in rolling shutters or of any description and in any position not otherwise specifically provided for complete all as specified and directed
31S&F Steel rolling shutters with 20 Gauge thickness of laths/curtain of GI sheet with flat profile and 22 Gauge thickness of laths/curtain with perforated profile GI rolling sheet upto 600 mm hight as per approved section/design/patterns, with ball bearing, Gear operated type with bevel gear box and crank handle and pipe of class 'B' and side rails minimum 100mm wide of minimum 3.15mm thick MS sheet, lock rail minimum of 3.15mm thick MS sheet as specified including top cover of 1.0mm thick GI sheet, anchoring rod, hasp and staple and erected in position as indicated, including complete all accessories etc required complete all as specified and directed.
32M&L for preparing new steel and iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
33M&L for preparing old steel and iron surfaces of any description and applying two coats of synthetic enamel paint complete all as specified and directed.
34M&L for Demolition of cement concrete un -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified and directed.
35M&L for RMC M-25 using 20mm garded stone aggregates as in base of floors/aprons/pavements/hardstandings etc, finishing surface even and smooth including necessary use and waste of form works required at site complete all as specified and directed.
36M&L for grade A Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound complete all as specified and directed.
37Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. any type complete all as specified and directed.
38Taking down unservesiable sub main wiring with conduits/battens etc complete all as specified and as directed.
39Taking down unservesiable MCCB DBs, MCB DBs including MCCBs/TPN/SPN/SP etc complete all as specified and as directed.
40M & L for Point wiring with single core PVC insulated but unsheathed 1.5 Sqmm FRLS multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVC concealed conduit, medium grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories including modular metal flush box with modular plate for mounting switches, sockets, fan regulators, etc and earth wire singlle core PVC insulated but unsheathed multistrand copper conductor cable 1100 volts grade IS-694 marked 1.5 Sqmm FRLS cable as continuous earth wire connecting to common earth dolly in concealed wiring system including making good the disturbed surface of wall complete all as specified and directed.
41One light point controlled by one switch one way
42One ceiling fan/exhaust fan point controlled by one switch.
43One socket outlet 5 Amp controlled by one switch on independent board
44One 3 pin 5Amps socket out let point on the same board controlled by one switch complete
45All as per Srl item No 40 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete, all as specified and directed.
46Supply and fixing in replacement of ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete all as specified and as directed.
47Supply and fixing white finished single mounting modular plates suitable for modular accessories of following sizes:-
48SuItable for 2 modules
49SuItable for 3 modules
50SuItable for 8 modules
51Supply and fixing of modular switch 1 way 6 Amps one module complete all as specified and directed.
52Supply and fixing in replacement of modular socket 6 Amps 2/3 Pin combined 02 module complete, all as specified and directed.
53Supply and fixing of modular switch one way 16 Amps, one module complete, all as specified and as directed.
54Supply and fixing of socket modular type 6 amp/16 amps, 2/3 pin combined 02 Module complete all as specified and as directed.
55Supply and fixing of Indoor decorative LED battens- integrated Box type 20 watt 4 feet white fixture with extruded aluminium body, suitable for LED tube 20 watt , bipin holder, connector block, LED rod 20 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete all as specified and directed.
56Supply and fix of LED bldg light 45 watt IP66 with internally prewired incl electronic driver and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and directed.
57S&F 100 W High Bay light Hanging type with white LEDs single phase complete with electronic controls and accessories 230 V complete all as specified and directed.
58Supply and fixing for sheet metal enclosure for distribution board SPN (when MCBs to be used ) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed.
59Supply and fixing in repalcement of vertical type load line distribution board, double door ,4 way , IP 43 IK08 AC, 3 phase, 415 volts, TPN bus bar and earth bar & din rail complete all as specified and as directed.
60Supply and fixing for MCCB, 4 pole 40 A, 16KA, 415Volts complete all as specified and directed.
61Supply and fixing in replacement of MCB, SP, 6-32A ,10KA complete all as specified and directed.
62Supply and fixing in replacement of MCB, SPN, 40A ,10KA complete all as specified and directed.
63Supply and fixing for sub main wiring with undermentioned run of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 V grade IS-694 drawing into and including rigid non metallic PVC conduit, medium grade ISI marked ( not less than 20 mm) with all conduit fittings & fixing accessories for concealed in wall/ ceiling or surface incl the specified run of specified size earth continuity conductor of similar type of cable complete all as specified and directed.Note- The undermentioned runs of single core cable and specified earth continuity conductor and revelent conduit with fitting acessories will be measured as one run.
64All as per Srl item No 63 here-in-before but 2 run of 2.5 sq mm and one run of 2.5 sq mm
65All as per Srl item No 63 here-in-before but 2 run of 4 sq mm and one run of 4 sq mm
66Supply & Laying XLPE insulated screened bedded galvanied steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor 1100 V grade cross sectional area 25 sq mm 4 core complete all as specified and directed.
67Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of Pipes, cables, poles,Stay and strips etc and getting out in Soft/Loose soil complete all as specified and directed.
68Returning, filling-in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed
69Removing excavated material not exceeding 50m and depositing where directed at a level of not exceeding 1.5m above the starting point complete all as specified and directed.
70Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
71M&L for Sand cushioning for cables 8 cm below the cable and 15 cm above the cable all as specified and directed .Note: Only Punned sand shall be measured.
72M&L for Earthing complete with galvanised steel earth plate electrode 600 mm x 600 cm x 6.00 mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including GI earth lead of GI wire 4.00 mmthick by means of steel bolts, nuts, check nuts and washers test points by GI pipe 40X8 mm 10 cm long,PCC 1:2:4 type B-1 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4type B-1 cover reinforced with 8 mm dia TMT bars @ 150 mm C /C both ways and 12 mm dia MS fabricated handle, mediam grade GI water pipe 20 mm bore with funnel, wire mesh and light gradeGI protection pipe 40 mm bore upto 5 M length for drawing in earth lead , salt charcol etc including excavation in earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 m complete , all as shown in Electric plate No 3 of MES schedule 2009 Part-I and connected complete including testing and complete all as specified and directed.
73Taking down ceiling fans & Exhaust of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades and deposit in MES store yard.complete all as specified and directed.
74S&F BLDC Ceiling fans AC single phase complete with electronic regulator and accessories 230 v 1200mm sweep, BEE 5 star rated and complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58201540
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 14-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To 16 Rolling Shutter Of Sheds Including Electrification And Masonry Work At Patiala Under Ge(S) Patiala.
Basic Detail
Tender No GE(S)/PAT/T-83/2026-27
Bidding Type Tender
Location
City Patiala
State Punjab
Key Dates
Publish Date 24 Oct 2026
Submission Date 14 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 96000
Exemption Available
Document List
22e66658-0cd7-41d4-a597-d0600ad82ad3.html
BOQ_892244.xls
T-83.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

22e66658-0cd7-41d4-a597-d0600ad82ad3.html

xls

BOQ_892244.xls

pdf

T-83.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender