Water Resources and Irrigation Government Departments Closing in 13 days TDR #58200074

Tender For Lis Bindala Mang - Providing, Fitting, Commissioning, Installation Of Fasd Starter Cum Panel For 02 No. 3 Phase 20 Hp Motors Consisting Of 80 . Contractors Including Lt Cables, Main Switch, Thimbles And Other Allied Works.

Issued by Government Departments · Rajouri, Jammu and Kashmir
Tender Value
3.50 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
13 days left
EMD
7000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Lis Bindala Mang - Providing, Fitting, Commissioning, Installation Of Fasd Starter Cum Panel For 02 No. 3 Phase 20 Hp Motors Consisting Of 80 . Contractors Including Lt Cables, Main Switch, Thimbles And Other Allied Works.

BOQ

Name of Work:- LIS Bindala Mang – Providing, Fitting, Commissioning, Installation of FASD Starter cum Panel for 02 No. 3 Phase 20 HP Motors consisting of 80 . Contractors including LT Cables, Main Switch, Thimbles and other allied works.
Sl. No. Item Description
1Providing/Fitting, Installation, Testing and Commissioning of protection panel cum FASD star delta starters at LIS Bindala Mang with the following specifications:Description of PanelDesigning, fabrication, installation, testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. For unit no. 1 and 2, with one incoming and two no outgoing for 20 HP Induction motors at LIS Bindala Mang. The panel shall be dust and vermin proof fabricated out of 16 SWG CR Sheet supported on M.S. angle of suitable size and having provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangements. The structure should be provided with suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of antirust primer and two coats of steel grey enamel paint. The panel should have equipped with following components/features: - 1. M.C.C.B:- The panel incomer should be fitted with a main incomer M.C.C.B. of 100 Ampere capacity (1 No.) and Outgoer MCCBs of 63 amp. Capacity (2 No.) for the two three phase motors, 1 no. voltmeter, 1 no ammeter along with a set of CTs, 1 No. V.S.S, 1 No. A.S.S. and a set of RYB indicators at incoming side. 2. Star delta Starter: - Fully automatic star delta starter cum panel for unit no I and unit no 2 should comprises of 2 Nos (for unit I & II) Main contactor of 80 Amp capacity each, 2 Nos. (for unit I & II) Delta contactor of 40 Amp capacity each, 2 Nos (for unit I & II) Star contactor of 40 Amp capacity each. 2 Nos (for unit I & II) star delta timer with timing range from 3 to 120 seconds, 4 Nos. push buttons for start and stop operation of both motor, 2 No. indicator 2 No. MCB 6 Amp for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables to complete the star delta circuit of outgoing supply for pumping unit no. 1 and pumping unit no 2. 3. Protection relay device cum Fault analyser: A protection relay device cum fault analyser shall be fitted with the panel with capability to protect the motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings: A. Voltage related protection: Single phasing, under voltage, over voltage, unbalance voltage. B. Current related protection: Over current/load, dry running, unbalance current /load, earth leakage, short circuiting. C. Mechanical fault related protection: Locked rotor etc.a. Display line current of RYB Phase and also line voltage of RY and YB phase.b. Display and indicate trip status for over load, under load, single phase, unbalance, earth fault, over voltage, under voltage respectively.4. Thermal overload relay: A thermal over load relay of suitable range should be fitted with in the starter as an extra protection to protect the motor in case of failure of fault analyser with an isolation/bye pass switch to bye pass the fault analyser.Complete job includes cost of providing/ Fitting, Transportation Charges, Testing and commissioning charges, tool and tackles charges, hire charges of skilled and unskilled labour, To and fro transportation charges at site of LIS and all other kind of Charges.
2P/f of Aluminium single core PVC insulated LT cable of 35 mm2 capacity of reputed make as per IS 7098 (Part 1) 1988 with up to date amendments of approximately 36m in combined length from the FASD starter cum panel to the two individual motor units. The job also includes p/f of 24 No. thimbles of requisite specifications by preparing all the ends of the LT cables and then making proper connections from the motor to the FASD starter cum panel. Complete job includes cost of providing/ Fitting, Transportation Charges, tool and tackles charges, hire charges of skilled and unskilled labour, To and fro transportation charges at site of LIS and all kinds of Charges.
3P/f of 100 Amp. HRC fuse based main switch in place of damaged worn out existing one. The job includes disconnecting the old LT cable connections from the worn-out main switch and extracting it by way of tools and tackles. Installation of new 100 Amp. Main switch main switch onto the wall by drilling holes onto the pump room wall at requisite area and finally installing the main switch by using nut-bolt or fasteners. The job further includes making back the old LT cable connections from both the transformer side and the panel side. Complete job includes cost of providing/ Fitting, Transportation Charges, tool and tackles charges, hire charges of skilled and unskilled labour, To and fro transportation charges at site of LIS and all kinds of Charges. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58200074
AUTHORITY Government Departments
TENDER VALUE 3.50 Lakhs
LAST DATE 13-11-2026
Authority
Authority Name Irrigation And Flood Control Department
Work Description Tender for Lis Bindala Mang - Providing, Fitting, Commissioning, Installation Of Fasd Starter Cum Panel For 02 No. 3 Phase 20 Hp Motors Consisting Of 80 . Contractors Including Lt Cables, Main Switch, Thimbles And Other Allied Works.
Basic Detail
Tender No MICD/J/30 of 2026-27
Bidding Type Tender
Location
City Rajouri
State Jammu and Kashmir
Key Dates
Publish Date 24 Oct 2026
Submission Date 13 Nov 2026
Open Date 14 Nov 2026
Finance
Tender Value 3.50 Lakhs
Tender Fee 500
EMD 7000
Exemption Not Available
Document List
7cd0a4a6-e12e-49e4-9280-061c610d28cf.html
BOQ_1116017.xls
SBD30.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

7cd0a4a6-e12e-49e4-9280-061c610d28cf.html

xls

BOQ_1116017.xls

pdf

SBD30.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender