Tender For B.O.Q For Construction Of 10 Roomed Double Storey Building Along With Allied Works At Hs Badroo B.W.O Electric Work
Tender Value
26.13 Lakhs
Estimated cost
Bid Submission
06 Nov 2026
5 days left
EMD
52280
Bank guarantee accepted
Document Fee
1100
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kulgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Construction Of 10 Roomed Double Storey Building Along With Allied Works At Hs Badroo B.W.O Electric Work
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) incl. cost of conduit. |
| 2 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent ) incl. cost of conduit |
| 3 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent) as approved by EIC |
| 4 | Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.) as approved by EIC |
| 5 | Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent) |
| 6 | i.3 pin 5A - 10A socket. |
| 7 | ii. indicator. |
| 8 | Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) incl. cost of conduit. Sample approved by EIC |
| 9 | Supply, installation, testing and commissioning of 12 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature - 10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series. |
| 10 | Supply, installation, testing and commissioning of 400mm sweep wall fans, incl. cost of ceiling rose and making of and necessary connections. (Havells/ Philips/ Crompton/ Anchor). |
| 11 | Supply, installation, testing and commissioning of 3 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of necessary connections. |
| 12 | Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd. |
| 13 | Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton). |
| 14 | Supply, installation, testing and commissioning of 100Watt LED Flood lighting luminaries having aluminum body, minimum 100lm/w, the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature -10`C to +45`C. LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). |
| 15 | Supplying and fixing of modular blanking plates on existing modular plate and switch box ,excluding modular plate as required. |
| 16 | Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, incl. cost of conduits(Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). |
| 17 | 2 x 1.5 sq.mm + 1x 1.5 sq. mm earth wire (Inverter/ solar circuit) |
| 18 | 2 x 2.5 sq.mm + 1x 2.5 sq. mm earth wire (Lighting circuit) |
| 19 | 2 x 6 sq.mm + 1x 6 sq. mm earth wire ( AC wiring) |
| 20 | 4x 4 sq.mm + 2x 4 sq. mm earth wire (Lighting sub main ) |
| 21 | 4 x 10 sq.mm + 2x 6 sq. mm earth wire (Heating sub main) |
| 22 | Supply and installation of 32A Industrial/modular plug/socket with 32A DPMCB for ACs |
| 23 | Supply and fixing of 4 way (4 + 12) Double door surface/ recess mounting , Vertical/ Horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. . |
| 24 | Supply and fixing of 16 way Double door surface/ recess mounting , Horizontal type, 240 V, SPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. . |
| 25 | Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 26 | Supply, installation, testing and commissioning of 32 A DP rating 240V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 27 | Supply, installation, testing and commissioning of 32/40A TP&N rating 240/ 415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 28 | Supply, installation, testing and commissioning of 63A TP&N rating 240/ 415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 29 | Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick. |
| 30 | Supply and fixing of ceiling rose , incl. cost of base block and necessary connections. |
| 31 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick , including accessories and providing masonry enclosure with cover plate having locking arrangements and watering pipe, trenching and filling with charcoal/coke and salt. |
| 32 | Providing and fixing of 25mmx5mm GI strip on surface or in recess for extending the earthing from earth electrode to controlling panel in one rim to be laid through required dia. of PVC conduit. |
| 33 | Supply, installation , testing and commissioning of 30 KVA, 3-Phase, 415V,LT, Unbalanced AVR of AE, ALBA, Chinar make, operating from input voltage of L-L=155-460V & L-N=90-265V, thereby producing the output voltage of 415V +_2% Phase to Phase and 230V +_2% Phase to Neutral. The AVR should have inbuilt Over voltage protection, Under voltage protection & Over loading with TDR. The stabilizer shall be servo controlled automatic, ONAN cooled and provided with first filling of fresh filtered transformer oil having required di-electric strength. The stabilizer shall be capable of smooth operation up to 10% un-balanced in the load currents complete with servo bye pass system consisting of 100A four pole manual type change over switch, 100A four pole MCCB 01 no. and required bus bar. The supplier has to give guarantee for any manufacturing defect with three servicing of the equipment for two years reckoned from commissioning. The job also includes all applicable taxes, carriages , loading and unloading. |
| 34 | SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point(a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgearc) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125).(d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificatesto be submitted) All as per pre approved by Engineer in charge. |
| 35 | Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type) |
| 36 | Normal Incoming |
| 37 | 250 Amp, 50 KA, FP MCCB |
| 38 | Aluminum Bus Bar 500 Amp set of 4 strips |
| 39 | ON Load Change Over Switch FP 200 amp. (Front operated) |
| 40 | Aluminum Bus Bar 400 Amp set of 4 strips |
| 41 | Digital Metering devices, comprising of Voltmeter, Ammeter, SelectorSwitch, Indicating Lamp, etc. |
| 42 | Outgoing |
| 43 | 63 Amp, TPN MCB 10KA |
| 44 | 40 Amp, 10 KA, TPN MCB |
| 45 | 32/40 Amp, 10 KA, DP MCB |
| 46 | Space for 16 way MCBs |
| 47 | Supply, laying, connecting and commissioning of 150 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped. ( under ground). |
| 48 | Supplying and laying of DWC HDPE (Double Wall Corrugated High Density Polyethylene) pipe, 200 mm dia.(OD – 200 mm & ID – 175 mm) ISI marked along with all accessories like sockets, bends, couplers, etc. with fitting and cutting, jointing, etc. (under ground), including excavation and refilling thetrench after laying the pipes.(complete job) |
| 49 | Supply and fixing of fan deep made of heavy gauge sheet in RCC slabs. |
| 50 | Supply and fixing of 4”/5’ deep junction boxes in RCC slabs. |
| 51 | Supply, installation , testing and commissioning of 3 star rating 1.5 Ton Inverter type split Air Conditioners suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector internal unit with one indoor and one outdoor unit. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle iron stand fitted with nut/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrile foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC insulated copper cable and a battery operated wireless remote unit. The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. (Daikin/ Blue Star/ LG/ IFB). |
| 52 | Supply, installation , testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90-260Volt thereby producing output voltage of 230volts +_ 3%. (4 KVA) |
| 53 | Supply, installation, testing and commissioning of 1625VA Power Inverter (Pure Sine Wave type) having generator compatible & provided and fitted with 2 no. 12V, 180 Ah, tall tubular batteries of Exide make and PVC trolley for resting/ housing of batteries. The job also includes terminal connections of batteries, input/ output leads of required size and length, carriage and applicable taxes. |
| 54 | Providing of ISI marked Dry type Co2 type Fire Extinguishers of 4.5 Kg capacity fitted with High Pressure Hose , Squeeze Grip type control valve with self indicating Pressure Gauge .(To be got approved before installation from EIC) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer