Project Description

Tender for Repair/ Maintenance Of Apfc Capacitor Bank, Fault Finding Lt Cables And Lt Panel Works At Tech Area Af Stn Tughlakabad

BOQ

Name of Work:- REPAIR/ MAINT OF APFC CAPACITOR BANK, FAULT FINDING LT CABLES AND LT PANEL WORKS AT TECH AREA AF STN TUGHLAKABAD
Sl. No. Item Description
1Material and Labour for under ground low tension cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed.Note :- The rate quoted by the contractor shall include the rate for excavating the cable at the fault location & pinpoint the fault, repairing the cable using cable jointing kits and by adding extra LT cable if required at site for jointing the cables as before to the panel and testing complete all as earth work and necessary T&P etc.
2Material and Labour for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set / Pole / feeder pillar lean concrete etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
3Supply and fix in replacement of cable route indicator made out of 15x15x6mm GI plate welded with 8 mm x 45cm long GI rod grouted in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the words 'HT cable' as directed with synthetic enamel paint of two coats over a coat of primer including excavation and earth work all as directed.
4Material and Labour Replacement of LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for 60 to 400 KVA transformer of any make /type/capacity all as specified and directed.
5Material and Labour Top gasket sheet made out of 2 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity complete all as specified and directed.
6Material and Labour Dehydrating breather assembly Aluminium/CI body of standard size filled with silica-gel for transformer of any capacity complete all as specified and directed
7Material and Labour Temperature gauge circular dia type of standard size for transformer of any complete all as specified and directed
8Material and Labour in replacement of HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity all as specified and directed.
9Supply and Fix in replacement digital type electronic voltmeter, size 96 mm x 96 mm, measuring range 0 to 500 V, flush pattern square type, suitable to be mounted on LT panel complete with and including suitable size of selector switch complete all as specified and as directed.
10Supply and Fix in replacement digital electronic ammeter range upto 400 A, size 96x96mm, flush pattern square type,suitable to be mounted on LT panel complete with and including suitable size of selector switch and CTs complete all as specified and as directed.
11Taking out hanging doors from LT Panels/ DG set/HT VCB panel welding the doors in position by using new hinges and scrapping old surface and cleaning smoothly, removing all dust and rust and relace the door closure if required including preparation of surfaces with synthatic enameled grey paint by using spray gun machine and writing capacity and location with black synthetic enamel paint complete all as directed.
12Cutting removing the vegetation growth and surface dressing, trimming of branches of trees coming on the sub stn or all around the installation yard including two pole structure areas, around power house, substation (external only) to keep always installation clean and tidy including white wash at plinth/ foundation of transformer if required complete all as specified and as directed.
13Supply and fixing of Straight through joints (Heat Shrink Kits) for LT underground cable complete for Armoured ,PVC sheathed Aluminium conductor cables by excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth all as specified and as directed for the following sizes:-
143.5 core cable 16 to 35 Sq mm.
153.5 core cable 50 to 95 Sq mm
163.5 core cable 120 to 185 Sq mm
173.5 core cable 240 to 300 Sq mm
18Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure all as directed.
19Material and Labour for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core. The fault located equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete all as specified and as directed.Notes : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 5 hours of receipt of intimation from Engineer-in-charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 02 hours duration.(ii) For the purpose of payment one unit of “each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch , irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii) Joints, jointing materials and cable required shall be measured and paid for separately.
20Material and Labour for painting of VCB panel any size of the panel including connected duct in the transformer room with synthatic enameled grey paint by using spray gun machine after removing all dust and rust. inside and out side and writing the location as per existing of paint with black synthetic enamel paint complete all as directed.
21Material and Labour for cement concrete in foundations, filling and mass comcrete type D2 1:4:8 with 40 mm graded stone aggrigate for foundation of pole etc complete all as specified.
22Supply and fix in repair hot moulded FRP looping /Junction box size 280 mmx200 mm for street light poles with locking arrangement and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock froof safe IP-65, weather,vermin proof,dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified and as directed.
23Dimantling and taking out Exhaust fan 230 volts 300 to 450mm sweep any make cutting the old burnt winding rewinding with new super enamelled copper wire as existing guage including insertion of insulating papers threading and insulating with insulating warnish, lathe work, replacement of capacitor, replacement of gun metal bushes/ bearing and painting after completion of rewinding process complete all as specified and as directed.
24Material and Labour for painting of LT panel (in both side) any size of the panel including connected LT bus duct in the transformer room with synthatic enameled grey paint by using spray gun machine after removing all dust and rust. inside and out side and writing the location as per existing of paint with black synthetic enamel paint complete all as directed.
25Supply and fixing in replacement of LED Bulb two pin/thired type suitable for fixing in lamp holder of capacity 5 Watt complete all as specified and as directed.
26Material and Labour in replacement of Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizees Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed.
27Material and Labour preparation of old painted steel surfaces or wire mess fencing around the out door transformer over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. Please Enable Macros to View BoQ information
28Material and Labour preparation of old painted steel surfaces or wire mess fencing around the out door transformer over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58192949
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 14-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Apfc Capacitor Bank, Fault Finding Lt Cables And Lt Panel Works At Tech Area Af Stn Tughlakabad
Basic Detail
Tender No CWE/TKD/TOKEN-82 OF 2026-2027
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 24 Oct 2026
Submission Date 14 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
BOQ_892296.xls
CompleteTender82.pdf
f47a8d09-4038-46ff-80e6-372d2ee96885.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_892296.xls

pdf

CompleteTender82.pdf

html

f47a8d09-4038-46ff-80e6-372d2ee96885.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender