Tender For Provision Of Certain Miscellaneous Sanctioned E/M Works At Gtre, Cabs, Cemilac, Stir And Debel Under Ge(I) R&D East Bangalore.
Tender Value
44.50 Lakhs
Estimated cost
Bid Submission
11 Nov 2026
17 days left
EMD
89000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Certain Miscellaneous Sanctioned E/M Works At Gtre, Cabs, Cemilac, Stir And Debel Under Ge(I) R&D East Bangalore.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 sq.mm making all connections complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Material and labour for cable jointing kit for 11 KV (earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq.mm complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 240 sq.mm 3.5 core with all accessories including making connection complete all as specified and as directed by Engineer-in-Charge |
| 4 | Supplying and fixing cable route marker HT and LT with 100 x 100 x 5 mm thick GI plate with inscription there on, bolted /welded to 35 mm x 35 mm x 6 mm angle iron, 600 mm long and fixing the same in ground complete all as specified and as directed. |
| 5 | Excavation in trenches n. exc. 1.5m wide and n exc. 1.5m in depth for taking out/laying cables in soft / loose soil complete all as specified and as directed. |
| 6 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers n exc. 25 cm thick complete all as specified and as directed. |
| 7 | Removing excavated material to a distance n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Material and labour for sand filling (pulverized stone dust) for cable cushioning including spreading and levelling complete all as specified and as directed by Engineer-in-Charge..NOTE :- Punned thickness only will be measured and paid. |
| 9 | Material and labour for precast concrete cable cover class HV, type I flat, size 300 x 180 x 40mm complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Material and labour for well burnt bricks, laid flat (old size) sub class B designation 75 for cable protection complete all as specified and as directed by Engineer-in-Charge |
| 11 | Supply and laying of GI pipe galvanised medium grade of size 80 mm dia for protection of cable across road including taking down of old unserviceable complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling with approvedmaterial, watering, well ramming / compacting and making good with PCC (1:2:4), type B-1, 100mm thick complete all as specified and as directed by Engineer-in-Charge. NOTE :- PCC shall be measured and paid separately. |
| 13 | Material and labour for Plain Cement Concret, (1:2:4) type B-1 using 20mm graded stone aggregate for making good the disturbed portion of road / floor / platform etc including form work compaction etc complete all as specified and as directed by Engineer-in-Charge |
| 14 | Disconnecting and taking out existing HT cable from VCBs after taking shut down and connecting the HT cable to the existing VCB including servicing and arrangement of all T&P required including testing the cable and VCB complete all as specified and as directed by Engineer-in-Charge |
| 15 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 KV (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed by Engineer-in-Charge |
| 16 | Supply and fixing on load Changover switch disconnectors with SS Enclosure 400 Amps 415V, 4 pole on walls with necessary accessories including all connections complete and testing after fixing of all connections complete all as specified and as directed by Engineer-in-Charge |
| 17 | Material and labour for dismantling of old unserviceable RCC two pole structure including all T&P required making good the surface as it is complete all as specified and as directed by Engineer-in-Charge |
| 18 | Material and labour for taking out old UG unserviceable existing HT cable of size 185 sq.mm with complete earth work involved and making good the surface as it is complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Material and labour for Earthing complete with copper earth plate electrode 600 x 600 x 3 mm thick copper earthing lead buried directly in ground vertically to a depth not less than 2.25 m deep below GL with the top edge of the plate at a depth not less than 1.5m from below normal GL connected to and including copper strip 25 x 5 mm as earthing lead by means of nuts, bolts, washers, check nuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part-I of 2010 and as specified or indicated and testing on completion including excavation / earthwork in any type of strata , including copper strip with GI protection pipe of 40mm medium grade 7.5 mtr long etc complete all as specified including testing and submission of test reports within permissible limit earth resistance not exceeding 1.0 ohm complete all as specified and as directed. |
| 20 | NOTE :- Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50 metre distance, PCC Pit, funnel and heavy duty PVC earthing pit cover,GI pipe etc. |
| 21 | Material and labour for test point terminal block made of Gun Metal or phosphorous Bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwes and test register with details of result complete all as specified and as directed of Engineer-in-Charge |
| 22 | Taking down ceiling fan of any size / type, sealing cable and dismantling blades and removing fan and blade to store complete all as specified and as directed.NOTE :- After disconnectioning the existing ceiling fan with electric connections and the same shall be shifted to AGE E/M store yard with out damage to ceiling fan all as directed. |
| 23 | Supply, installation, testing and commissioning of ceiling fan 5 star rating , BLDC capacity 30 Watt Max with regulator,BLDC Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm to 90 cm long down rod, 2 nos. canopies, shackle kit, safety rope, 100 % pure copper winding, aluminium body. air delivery ≥ 215 CFM at 5 -speed, boost mode, summer/ winter, Power Factor not less than 0.9, Service Value ≥7.2, BEE 5 -Star, (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, Warranty 2 yrs on fan , 3 yrs on PCB including safety pin, nut, bolts, washers, temperature rise=75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply ceiling fan compliant to IS 374:2019, external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Taking down exhaust fan of any size / type, sealing cable and dismantling blades and removing fan and blade to store complete all as specified and as directed.NOTE :- After disconnectioning the existing exhaust fan with electric connections including making good the disturbed surfaces to match with existing surface and shifting the same to AGE E/M store yard with out damage to exhaust fan all as directed. |
| 25 | Supply and fix exhaust fan, steel body, AC single phase. 230V of size 300mm sweep with shutter 900 RPM with, blades, frame and louvers including cutting the wall of stone/ brick masonry as per the size of exhaust fan including grouting the bolts, nuts etc for fixing necessary connection with three core flexible wire from exhaust fan to ceiling rose and making good the disturbed surface as the existing one, complete all as specified and as directed. |
| 26 | Supply and fix exhaust fan, steel body AC single phase. 230V of size 450mm sweep with shutter 1400 RPM with, blades, and frame and louvers including cutting the wall of stone / brick masonry as per the size of exhaust fan including grouting the bolts, nuts etc for fixing necessary connection with three core flexible wire from exhaust fan to ceiling rose and making good the disturbed surface as the existing one, complete all as specified and as directed. |
| 27 | Supply and fix exhaust fan, steel body AC single phase. 230V of size 600mm sweep with shutter 900 RPM with, blades, and frame and louvers including cutting the wall of stone/ brick masonry as per the size of exhaust fan including grouting the bolts, nuts etc for fixing necessary connection with three core flexible wire from exhaust fan to ceiling rose and making good the disturbed surface as the existing one, complete all as specified and as directed. |
| 28 | Supply, install, testing and commissioning of minimum 1 star rated floor mounted vertical type split tower Air conditioner complete with cordless LCD display remote control unit, HEPA filter, energy efficiency dual rotary compressor, turbo cool, silent indoor operation (equal or less than 50.5 dB ), wide angle power full air flow with 2 way swing, cooling capacity of 48000 Btu/hr, Rated SEER 1, three phase, 415 Volts, 50 Hz,having eco friendly R 32 refrigerant gas, 100% copper evaporator/condenser coil of capacity 4 TR with all fixing arrangements including copper pipe and refrigerant gas all as per requirement at site complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Material and labour for wiring for circuit/ submain wiring along with earth wire with the 4 x 4 sq.mm + 2 x 4 sq.mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required complete all as specified and as directed. |
| 30 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required complete all as specified and as directed. |
| 31 | Material and labour for 25 mm Low density polyethylene pipes (LDPE) of pressure 6kgf/sqcm as in drain pipe fixed complete on walls, ceilings including all accessories complete all as specified and as directed. |
| 32 | Supply and fix MCB TP 5-32 Amps rating 415 V,10 KA 'C' curve miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc., as required complete all as specified and as directed. |
| 33 | Supply and laying of extra copper pipe of size 1/2\\" with nitrile rubber insulation,thermo rexin tape and 4 Core x 2.5 sq.mm copper cable using necessary supports and fasteners complete all as specified and as directed. |
| 34 | Supply and laying of extra copper pipe of size 1/4\\" with nitrile rubber insulation and thermo rexine tape using necessary supports and fasteners complete all as specified and as directed. |
| 35 | Making opening / drilling of size 65 mm dia, using heavy duty stone driller/cutter machine in the stone machinery wall for installing split type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface complete all as specified and as directed. |
| 36 | Material and labour for sub main wiring single core, PVC Insulated, unsheathed, multi stranded copper conductor cable, 1100 Volts of size 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, FRLS Grade, ISI Marked, drawn through and including suitable PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including One run of Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, green in colour, 1100 Volts, FRLS Grade as earth continuity conductor complete all as specified and as directed. NOTE :-: Two runs of 1.5 sq.mm copper cable,one run earth wire of 1.5 sq.mm copper cable and PVC conduit shall be measured and paid as one RM. |
| 37 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Amps modular socket outlet and 5/6 A modular switch, connections etc as required. |
| 38 | Supply and fixing Pedestal fan PVC body with AC single phase 150-265 Volts of size 450 mm sweep 100% copper motor, double ball bearings complete all as specified and as directed. |
| 39 | Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 120 sq.mm 3.5 core with all accessories including making connection complete all as specified and as directed. |
| 40 | Material and labour for earthing complete with galvanised iron earth plate electrode 600x600x6 MM as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts and connected to earthing test point all as shown in elecrical plate No-5 of SSR part -1 of 2009 specified or indicated and testing on completion including excavation /earth work in any type of starta PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1 : 2 : 4 ) type B1 , Reinforced with welded steel wire fabric (XPM) weight not less than 4 KG /sqm cast iron frame ,funnel with wire mesh GI watering pipe of 20 mm bore medioum grade and lugs with and including GI earth wire 4 mm dia with GI proction pipe of 15 mm medium grade 7.5 meter grade 7.5 meter long etc complete all as specified and as directed. |
| 41 | Material and labour fo for boring holes under pavement, hard standing by trenchlesss technology using ultra sound technique and necessary machine including provision of HDPE/GI pipe of 150 mm dia suitable for 0.4 MPa working pressure complete all as specified and directed by Engr-in-charge |
| 42 | Supply and fixing MCCB 250 Amps with enclosure 4 pole 36 KA with thermal magnetic release DRX type fixing on wall including complete cable connections and testing for smooth functioning of the electric suplly complete all as specified and as directed by Engr-in-charge. |
| 43 | Material and labour fo CPRI approved LT Panel, indoor type totally enclosed vermin proof of size 1200x1000x400 mm double door both front and back side with locking arrangement, pre wired made out of 2.00 mm thick CRCA sheet with 04 Nos legs MS angle iron 40x40x6mm size 0.6mtr long suitably grouted in ground with PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) and cement plaster 1:4 including two coats of synthetic enamel paint over a coat of rid oxide primer and S&F aluminimum busbar 400 Amps rated, duly colour coded 04 Nos and connected through copper wire of appropriate size to connect the various accessories like MCCB MCB conductor etc to be accommodated in it and connecting incoming and outgoing cable by means of necessary lugs gland PVC tape including testing on complete all as specified and directed by Engr-in-Charge including the following :- (i) MCCB 250 Amps 4 pole 36 KA -01 No (ii) MCCB 125 Amps 4 pole 25 KA -03 No's(iii) Digital voltmeter and Amp meter, indicating lamps, trip indicators, auxiliary switches etc including all accesories required for fixing complete all as specified and as directed. |
| 44 | Material and labour for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I, ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed surface/ concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for One Light / Fan Point controlled by One Switch complete all as specified. |
| 45 | Supply and fix ceiling rose surface backelite two to three terminal complete all as directed. |
| 46 | Supply and fixing exhaust fan, steel body AC single phase 230 volt of size 300 mm sweep with blades and frame with louvres including making of suitable hole in the wall complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysNov 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓