Tender For Construction Of The Joint District Divisional Home Guard Office In District Azamgarh
Tender Value
5 Crore
Estimated cost
Bid Submission
30 Oct 2026
3 days left
EMD
10.01 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Azamgarh → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of The Joint District Divisional Home Guard Office In District Azamgarh
BOQ
| Sl. No. | Item Description |
| 1 | 1- Main Building District Commandant Office (G+1) |
| 2 | i- Civil Work |
| 3 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All Kind of Soil |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 5 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 7 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 8 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Footing) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Column upto plinth) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Column |
| 12 | Ground Floor |
| 13 | First floor |
| 14 | Second floor |
| 15 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Plinth Band) |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Lintel Band) |
| 17 | Ground Floor |
| 18 | First floor |
| 19 | Second floor |
| 20 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Projection) |
| 21 | Ground Floor |
| 22 | First floor |
| 23 | Second floor |
| 24 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Beam) |
| 25 | Ground Floor |
| 26 | First floor |
| 27 | Second floor |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) |
| 29 | Ground Floor |
| 30 | First floor |
| 31 | Second floor |
| 32 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 33 | Ground Floor |
| 34 | First floor |
| 35 | Second floor |
| 36 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 37 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 38 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 39 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :(1 cement : 6 coarse sand) (230mm wall) |
| 40 | Ground Floor |
| 41 | First floor |
| 42 | Second floor |
| 43 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
| 44 | Ground Floor |
| 45 | First floor |
| 46 | Second floor |
| 47 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing toframe with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 48 | Ground Floor |
| 49 | First floor |
| 50 | Second floor |
| 51 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 52 | Second class teak wood |
| 53 | Ground Floor |
| 54 | First floor |
| 55 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 56 | Ground Floor |
| 57 | First floor |
| 58 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 |
| 59 | Ground Floor |
| 60 | First floor |
| 61 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.1 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 62 | First floor |
| 63 | Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge. |
| 64 | Ground Floor |
| 65 | First floor |
| 66 | Providing and fixing factory made PVC door shutter made of solid foam PVC profiles of thikness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top/ bottom/ lock) rails of minimum cross section of 70mmx 28mm, of shape and design as per manufacturer's specifications having homogenous fine cellular structure and smooth integral outer skin, inserted with G.I. 'C' section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stiffeners as per manufacturer's specifications Mitred cut joints for styles and rails provided with telescopic polymeric 'L' corners are |
| 67 | jointed together using solvent adhesive and strenghtened with fully threaded stainless steel screws (of required size) through reinforced stiffener with paneling of specified solid foam PVC board/ high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam PVC moulded beadings of required size using PVC solvent adhesive/ cement. The finished door shutter including SS hardware, 1 no. ss sliding bolt 200 x 10mm, 1 no. SS tower bolt 200 x 10 mm and 2 nos. SS handles 125mm, shall be fixed to frame with 3 nos, stainless steel hinges of minimum size 100x58x1.9 mm and stainless steel screws of required size complete as per direction of the Engineer-in-Charge. (Cost of above hardware is inclusive in rates |
| 68 | 5 mm thick solid foam PVC panel of required size with moulded/ extruded beading of appropriate design shape and size as per manufacturer's specifications (to secure the panel insert tight in place within the style and rails of shutter) matching the colour and shade of shutter frame. Non decorative type. |
| 69 | Ground Floor |
| 70 | First floor |
| 71 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 72 | Casement Window with Double Rebate Frame with one Side Hung Glazed Panel and one Side Hung wire mesh Panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles on both glazed and fly screen panel |
| 73 | Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & metal grill (if required to be paid separately). (Height upto 1.8 metre) |
| 74 | Ground Floor |
| 75 | First floor |
| 76 | Second floor |
| 77 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 78 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading |
| 79 | Ground Floor |
| 80 | First floor |
| 81 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 82 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 83 | Ground Floor |
| 84 | First floor |
| 85 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) |
| 86 | Ground Floor |
| 87 | First floor |
| 88 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 89 | Ground Floor |
| 90 | First floor |
| 91 | Second floor |
| 92 | Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS : 14842, including top cover of 6 mm coir veneer board, nickle plated M.S. Pipe 20 mm dia. (heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. Flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. |
| 93 | Ground Floor |
| 94 | First floor |
| 95 | Second floor |
| 96 | Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Marine plywood conforming to IS: 710 |
| 97 | Ground Floor |
| 98 | First floor |
| 99 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
| 100 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm |
| 101 | Ground Floor |
| 102 | First floor |
| 103 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x16 mm |
| 104 | Ground Floor |
| 105 | First floor |
| 106 | Second floor |
| 107 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 108 | Ground Floor |
| 109 | First floor |
| 110 | Second floor |
| 111 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper |
| 112 | Ground Floor |
| 113 | First floor |
| 114 | Second floor |
| 115 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 116 | Ground Floor |
| 117 | First floor |
| 118 | Second floor |
| 119 | 12mm thick plaster proportion of 1:6 cement & approved coarse sand |
| 120 | Ground Floor |
| 121 | First floor |
| 122 | Second floor |
| 123 | 15mm thick plaster with proportion of 1:6 cement & approved coarse sand |
| 124 | Ground Floor |
| 125 | First floor |
| 126 | Second floor |
| 127 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 128 | Ground Floor |
| 129 | First floor |
| 130 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.. (Size of Tile 600x600 mm)(Kajaria. Somany or Equivalent) |
| 131 | Ground Floor |
| 132 | First floor |
| 133 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 134 | Ground Floor |
| 135 | First floor |
| 136 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 137 | Ground Floor |
| 138 | First floor |
| 139 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 140 | Ground Floor |
| 141 | First floor |
| 142 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : |
| 143 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent |
| 144 | Ground Floor |
| 145 | First floor |
| 146 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: |
| 147 | First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
| 148 | Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 149 | (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 150 | Ground floor to First Floor |
| 151 | Supply & filling of cinder in sunken portion of building including breaking into required sizes including supply of all material, labour, T&P required for proper completion of work. |
| 152 | First floor |
| 153 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 154 | Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 155 | Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 156 | After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. |
| 157 | Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 158 | The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 159 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm.. |
| 160 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase |
| 161 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 162 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 163 | Ground Floor |
| 164 | First floor |
| 165 | Second floor |
| 166 | One priming coat & one coat oil distemper on new work including supply of material, labour T&P etc. required for proper completion of the work. (Two Coat) |
| 167 | Ground Floor |
| 168 | First floor |
| 169 | Second floor |
| 170 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 171 | Ground Floor |
| 172 | First floor |
| 173 | Second floor |
| 174 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufactur. |
| 175 | Ground Floor |
| 176 | First floor |
| 177 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 178 | Terrace Floor |
| 179 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 180 | Centering and shuttering including strutting, propping etc. and removal of form for Footing |
| 181 | Centering and shuttering including strutting, propping etc. and removal of form for Column upto plinth |
| 182 | Centering and shuttering including strutting, propping etc. and removal of form for Column |
| 183 | Ground Floor |
| 184 | First floor |
| 185 | Second floor |
| 186 | Centering and shuttering including strutting, propping etc. and removal of form for Plinth Band |
| 187 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel Band |
| 188 | Ground Floor |
| 189 | First floor |
| 190 | Second floor |
| 191 | Centering and shuttering including strutting, propping etc. and removal of form for Projection |
| 192 | Ground Floor |
| 193 | First floor |
| 194 | Second floor |
| 195 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel Band |
| 196 | Ground Floor |
| 197 | First floor |
| 198 | Second floor |
| 199 | Centering and shuttering including strutting, propping etc. and removal of form for Slab |
| 200 | Ground Floor |
| 201 | First floor |
| 202 | Second floor |
| 203 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 204 | Making Apron along with Drain (600mm wide apron and 250x300mm drain with 100 thick base (1 cement 4 coarse sand 8 aggregate) 20mm plaster in drain inner side with finish with cement slurry and 25mm cement flooring under apron, including necessary excavation, levelling & dressing & finishing the top smooth |
| 205 | ii- Internal Water Supply & Sanitation Work |
| 206 | SANITARY INSTALLATIONS & C.P FITTINGS |
| 207 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: :Parryware /Hindware /Seabird /Orient (Coral)or equivalent |
| 208 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 209 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 210 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 211 | Providing and fixing Stainless steel A lsl 304 ('18/B) kitchen sink as per lS:13983 with Cl brackets and stainless steel pug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever rquiaed. Kitchen sink with drain board |
| 212 | 510x1040mm bowl depth 250mm |
| 213 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 214 | Flexible Pipe |
| 215 | 32 mm dia |
| 216 | 40 mm dia |
| 217 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 218 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 219 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 220 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 221 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1.00 meter long with S.S. triangular plate for European type W.C. of quality and make as approved by engineer-in-charge. |
| 222 | 15 mm nominal bore |
| 223 | Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 224 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 225 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 226 | CP Brass fittings |
| 227 | Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 228 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100mm |
| 229 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 230 | a) 15 mm nominal bore |
| 231 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 232 | a) 15 mm nominal bore |
| 233 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 234 | a) 15 mm nominal bore |
| 235 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 |
| 236 | a) 15 mm nominal bore |
| 237 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: |
| 238 | 20mm nominal bore |
| 239 | PVC PIPES & FITTINGS AND RAIN WATER PIPES |
| 240 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 241 | 110mm |
| 242 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 243 | 110 mm |
| 244 | 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 245 | Coupler |
| 246 | 110 mm bend |
| 247 | Bend 87.5° |
| 248 | 110 mm bend |
| 249 | Shoe (Plain) |
| 250 | 110 mm bend |
| 251 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 252 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 253 | Provlding & fixing soil, waste and vent pipes |
| 254 | a) 110 mm dia Unplasticised PVC pipe |
| 255 | a) 75 mm dia Unplasticised PVC pipe |
| 256 | Providing & fixing UPVC pipe clip |
| 257 | a) for 110 mm dia pipe |
| 258 | a) for 75mm dia pipe |
| 259 | Providing & fixing rubber seal |
| 260 | a) 110mm dia |
| 261 | b) 75mm dia. |
| 262 | Providing and fixing plain sanitary bend. |
| 263 | a) 110mm |
| 264 | b) 75mm |
| 265 | Providing and fixing U pvc single equal tee (without door) |
| 266 | a) 75x75x75 mm |
| 267 | a) 110x110x110 mm |
| 268 | Providing and fixing U pvc single equal tee (with door) |
| 269 | a) 75x75x75 mm |
| 270 | a) 110x110x110 mm |
| 271 | Providing and fixing U pvc Shoe |
| 272 | a) 75 mm |
| 273 | a) 110 mm |
| 274 | INTERNAL & EXTERNAL WATER SUPPLY WORKS |
| 275 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. |
| 276 | 15mm dia nominal outer dia pipes |
| 277 | 20mm dia nominal outer dia pipes |
| 278 | 25mm dia nominal outer dia pipes |
| 279 | 32mm dia nominal outer dia pipes |
| 280 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 281 | Internal work-Exposed on wall |
| 282 | 20mm dia nominal bore |
| 283 | 25mm dia nominal bore |
| 284 | 32mm dia nominal bore |
| 285 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 286 | 25mm dia nominal bore |
| 287 | 32mm dia nominal bore |
| 288 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Capcity in Per Liters |
| 289 | SEWERAGE SYSTEM |
| 290 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 291 | Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 292 | 200 mm diameter |
| 293 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design |
| 294 | 200 mm diameter |
| 295 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 296 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 Fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 297 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 298 | iii- Internal Electrical Work |
| 299 | Point Wiring : |
| 300 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 301 | Group C |
| 302 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 303 | Power plug wiring in PVC conduit (2 x 4 Sq.Mm.):- |
| 304 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 305 | Power plug wiring in PVC conduit (4 x 4 Sq.Mm.):- |
| 306 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 307 | Circuit/ Sub main wiring in PVC conduit:- |
| 308 | Submains : |
| 309 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 310 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 311 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 312 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 313 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 314 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 315 | 5/6 A switch |
| 316 | 3 pin 5/6 A socket outlet |
| 317 | Telephone socket outlet |
| 318 | TV antenna socket outlet |
| 319 | Bell Bush |
| 320 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 321 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 322 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (for A.C. Point/MCB Point) |
| 323 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 324 | 6 way (4 + 12), Double door |
| 325 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 326 | 4 way (4 + 12), Double door |
| 327 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 328 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 329 | 100 A,30KA,FPMCCB |
| 330 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 331 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 332 | 25 mm |
| 333 | 32 mm |
| 334 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A |
| 335 | Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A |
| 336 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 337 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. |
| 338 | 63 amps. |
| 339 | Supplying and fixing following rating, four pole, (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensivity current upto 300 miliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required: |
| 340 | 63 amps. |
| 341 | Earthing Work : |
| 342 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 343 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 344 | Lighting Fixtures (Lights/Fans) : |
| 345 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA |
| 346 | Supply & fixing of IP 20, Frount Mid Power SMD type LED Light Recess mounting round 12 to 15 Watt Cut out Min 125 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA1440-1800 system lumens >120 Lm/W, PF>0.95, THD< 10% at full load CRI >80, > 300 V over voltage Protection 2.5 KV internal Surge Protection with (5 Year Warrenty) |
| 347 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. 4320-5520 system lumens with fully covered diffuser type >120 Lm/W, PF>0.95, THD< 10% at full load CRI >80, > 300 V over voltage Protection 4 KV internal Surge Protection with (5 Year Warrenty) |
| 348 | Supply and fixing of water tight oblong 10 Watt LED bulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. |
| 349 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required- |
| 350 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 351 | Supply and fixing of Profile light Fitting for false Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. 320-520 system lumens with fully covered diffuser type >120 Lm/W, PF>0.95, THD< 10% at full load CRI >80, > 300 V over voltage Protection 4 KV internal Surge Protection with (5 Year Warrenty) |
| 352 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 353 | 35 sqmm 3.5 core |
| 354 | 10 sqmm 2 core |
| 355 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire |
| 356 | 35 sqmm 3.5 core |
| 357 | 10 sqmm 2 core |
| 358 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. |
| 359 | 35 Sq.mm |
| 360 | 10 sqmm |
| 361 | Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules. |
| 362 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. |
| 363 | Supply and installation of Kitchen Chimney (suction-1250 m³/ hr) of make-Faber/KAFF/ sleek/Glen with smoke PVC pipe 150mm or as per Manufacturer specifications as per instructions, complete. |
| 364 | Supply Installation, testing, and commissioning of Orient Electric Wall- 49 Wall Fan with Remote & Automatic Speed Control | Wall Fan with Tilt & Oscillation mechanism | Remote with Display Panel & Timer |
| 365 | Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.0mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and |
| 366 | All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. |
| 367 | The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. |
| 368 | The minimum clearances between bus bars shall be as follows : |
| 369 | Phase to phase - minimum 20mm |
| 370 | Phase to neutral-minimum 15mm |
| 371 | Meter Panel Board |
| 372 | Incoming : |
| 373 | One (1) No 200 Amp. 4P MCCB of 30 KA Breaking capacity |
| 374 | Metering : |
| 375 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 376 | One (1) No. (0-63A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 377 | One (1) Set of Phase Indication Lamp. |
| 378 | Bus Bar : |
| 379 | One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length. |
| 380 | Outgoing : |
| 381 | Phase indication lamps on each outgoing to be provided. |
| 382 | 63 Amps DP MCB of 10KA (Ics=Icu) Breaking Capacity- 6 No |
| 383 | 40 Amps DP MCB of 10KA (Ics=Icu) Breaking Capacity-19 No |
| 384 | 63 Amps DP MCB of 10KA (Ics=Icu) Breaking Capacity- 3 No Spare |
| 385 | 40 Amps DP MCB of 10KA (Ics=Icu) Breaking Capacity- 3 No Spare |
| 386 | iv- Rainwater Harvesting |
| 387 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 388 | In all kind of soil upto 1.5m depth |
| 389 | In all kind of soil upto 1.5m to 3.0m. depth |
| 390 | In all kind of soil upto 3.0m to 4.5m. depth |
| 391 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 392 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 4 coarse sand) |
| 393 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Beam) |
| 394 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) |
| 395 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 396 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 397 | With 20x20mm square bar |
| 398 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 399 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 400 | Circular shape 500 mm internal diameter |
| 401 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. |
| 402 | Drilling of 300mm dia bore hole manually. |
| 403 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 404 | 150 mm nominal size dia |
| 405 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 406 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 407 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 408 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 409 | EXTERNAL PIPE NETWORK SYSTEM |
| 410 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, |
| 411 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 412 | a) Pipes 80mm to 300mm diameter. |
| 413 | Providing and laying PVC PIPES |
| 414 | 150 mm dia. R.C.C. pipe |
| 415 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of NP2 pipes including bed concrete as per standarddesign |
| 416 | 150 mm dia. R.C.C. pipe |
| 417 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 |
| 418 | Constructing masonry Chamber 90x90x10 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 419 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 420 | Centering and shuttering including strutting, propping etc. and removal of form work with water proof ply 12mm thick : Beam |
| 421 | Centering and shuttering including strutting, propping etc. and removal of form work with water proof ply 12mm thick : Slab |
| 422 | v- Septic Tank and soak pit |
| 423 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 424 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 425 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 426 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) |
| 427 | Centering and shuttering including strutting, propping etc. and removal of form for Slab |
| 428 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 429 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 430 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20mm thick |
| 431 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 432 | Providing M.S. foot rests including fixing in tank with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 433 | 500 mm diameter C.I. cover (medium duty) |
| 434 | the cover to be not less than 58 kg (DSR 19.18.2) |
| 435 | C.I. Plain bend (DSR 17.39.1.2) |
| 436 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1) |
| 437 | vi- Fire Alarm System |
| 438 | INTELLIGENT FIRE ALARM SYSTEM |
| 439 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 440 | Ten Loop Panel. |
| 441 | Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required |
| 442 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 443 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 444 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required |
| 445 | Supplying, installation, testing & commissioning of addressable manual call point complete as required |
| 446 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 447 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 448 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required |
| 449 | Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910 . |
| 450 | Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEY confirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285 |
| 451 | vii- Fire PA System |
| 452 | Supplying, installation, testing & commIssIoning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 453 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 454 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm |
| 455 | 2- Pump Room |
| 456 | i- Civil Work |
| 457 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.all kinds of soil |
| 458 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 459 | Same as above but for under floor |
| 460 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Lintel of doors & window, sunshades etc. |
| 461 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 462 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) In plinth. |
| 463 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 464 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 465 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 466 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 467 | SUPER STRUCTURE |
| 468 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 469 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 470 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 471 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Lintel of doors & window, sunshades etc. |
| 472 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Slab. |
| 473 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 474 | Plinth Lvl- |
| 475 | Ground Floor |
| 476 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding (hold fast) |
| 477 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 478 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 479 | Fixing of Door, windows / ventilators chaukhats in position. |
| 480 | Ground Floor |
| 481 | (a) Door chaukhats |
| 482 | (b) Window chaukhats |
| 483 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 484 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 485 | 12mm thick plaster in 1:4 on ceiling and soffits of stairs upto floor two level |
| 486 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 487 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40 mm flooring) |
| 488 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40 mm flooring) |
| 489 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 490 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 491 | Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
| 492 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : With 4.0 mm thick glass panes. |
| 493 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 494 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 495 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 496 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 497 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 498 | Construction of drain along with apron. |
| 499 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 35 mm wide and 3.15 mm thick |
| 500 | Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. |
| 501 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 502 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 503 | ii- Internal Electrical Work |
| 504 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 505 | Group C |
| 506 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 507 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 508 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 509 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 510 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 511 | MCB's & DB’s : |
| 512 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 513 | 4 way (4 + 12), Double door |
| 514 | 6 way (4 + 18), Double door |
| 515 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 516 | 4 way (4 + 12), Double door |
| 517 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 518 | Single pole |
| 519 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 520 | ELCB/RCCB Switches : |
| 521 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 522 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 523 | Supplying and drawing following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. |
| 524 | 2 Pair |
| 525 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 526 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 527 | Telephone socket outlet |
| 528 | TV antenna socket outlet |
| 529 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 530 | 75mm X 75 mm X 60mm Deep |
| 531 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 532 | 1 or 2 Module (75mm X 75 mm) |
| 533 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 534 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 535 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. |
| 536 | S/F of single light wall bracket on matching M.D.F.E.G. board base etc. complete in all respects. |
| 537 | Supply and fixing of surface/ flush mounting 6 way TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer Incharge. |
| 538 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects. |
| 539 | Supply and fixing of single pole MCB blanking plate |
| 540 | CAT B |
| 541 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 510 mm sweep |
| 542 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 543 | 10 sqmm 2 core |
| 544 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required- |
| 545 | 300mm sweep. |
| 546 | 3- Guard Room |
| 547 | i- Civil Work |
| 548 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 549 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 550 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 551 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 552 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 553 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Plinth Band) |
| 554 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Lintel Band) |
| 555 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Projection) |
| 556 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) |
| 557 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 558 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 559 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :(1 cement : 6 coarse sand) (230mm wall) |
| 560 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
| 561 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing toframe with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 562 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 563 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 564 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 565 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 |
| 566 | Providing and fixing factory made PVC door shutter made of solid foam PVC profiles of thikness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top/ bottom/ lock) rails of minimum cross section of 70mmx 28mm, of shape and design as per manufacturer's specifications having homogenous fine cellular structure and smooth integral outer skin, inserted with G.I. 'C' section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stiffeners as per manufacturer's specifications Mitred cut joints for styles and rails provided with telescopic polymeric 'L' corners are jointed together using solvent adhesive and strenghtened with fully threaded stainless steel screws (of required size) through reinforced stiffener with paneling of specified solid foam PVC board/ high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam PVC moulded beadings of required size using PVC solvent adhesive/ cement. The finished door shutter including SS hardware, 1 no. ss sliding bolt 200 x 10mm, 1 no. SS tower bolt 200 x 10 mm and 2 nos. SS handles 125mm, shall be fixed to frame with 3 nos, stainless steel hinges of minimum size 100x58x1.9 mm and stainless steel screws of required size complete as per direction of the Engineer-in-Charge. (Cost of above hardware is inclusive in rates 5 mm thick solid foam PVC panel of required size with moulded/ extruded beading of appropriate design shape and size as per manufacturer's specifications (to secure the panel insert tight in place within the style and rails of shutter) matching the colour and shade of shutter frame. Non decorative type. |
| 567 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. In windows |
| 568 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 569 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 570 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm |
| 571 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x16 mm |
| 572 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : (copper oxidized as per IS: 1378)125mm |
| 573 | 12mm thick plaster in inner walls with proportion of 1:6 cement & approved coarse sand |
| 574 | 15mm thick plaster in Outer walls with proportion of 1:6 cement & approved coarse sand |
| 575 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 576 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick |
| 577 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick |
| 578 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 579 | Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 580 | Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 581 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 582 | Ground Floor |
| 583 | One priming coat & one coat oil distemper on new work including supply of material, labour T&P etc. required for proper completion of the work. (Two Coat) |
| 584 | Ground Floor |
| 585 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 586 | Ground Floor |
| 587 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufactur |
| 588 | Ground Floor |
| 589 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 590 | Ground Floor |
| 591 | Centering and shuttering including strutting, propping etc. and removal of form for Plinth Band |
| 592 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel Band |
| 593 | Ground Floor |
| 594 | Centering and shuttering including strutting, propping etc. and removal of form for Projection |
| 595 | Ground Floor |
| 596 | Centering and shuttering including strutting, propping etc. and removal of form for Slab |
| 597 | Ground Floor |
| 598 | Providing and fixing M.S. fan clamp type | or Il of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 599 | Providing and fixing circular’ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 600 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 601 | ii- Internal Electrical Work |
| 602 | SUB HEAD - I: CIRCUIT CUM POINT WIRING |
| 603 | SWITCH CONTROL LIGHT POINTS |
| 604 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 605 | Light Point |
| 606 | Fan Point |
| 607 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 608 | MCB CONTROL LIGHT POINTS |
| 609 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 610 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 611 | 2X4 sq. mm + 1X4 sq. mm earth wire |
| 612 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. |
| 613 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 614 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 615 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 616 | 1 or 2 Module (75mmX75mm) |
| 617 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 618 | 3 pin , 5/6 amps socket outlet |
| 619 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 620 | 25 mm |
| 621 | SUBHEAD -II - FITTINGS & FIXTURES |
| 622 | Supply & fixing of LED Tube Light witH Metal heavy duty Box type batten light fitting 1 x 22 watt suitable for upto 1X22W LED Polycarbonate tube light complete including tube etc on surface complete in all respects. |
| 623 | Supply, Installation, Testing and Commissioning of 9W (Nominal) Wall Bracket Light |
| 624 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 625 | SUBHEAD - III - DISTRIBUTION BOARDS |
| 626 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 627 | 6 way, Double door |
| 628 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 629 | Single Pole |
| 630 | Single Pole Neutral |
| 631 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 632 | iii- Internal Plumbing Work |
| 633 | SANITARY FIXTURES & ACCESSORIES : I |
| 634 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 635 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. (a) White Vitreous China Flat back wash basin size 550 x 400 mm with single 15 mm C.P. brass pillar tap. |
| 636 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe (a) 32mm dia |
| 637 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe (b) 40mm dia |
| 638 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 639 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. |
| 640 | Providing & fixing PVC pipes conforming to IS make workinh pressure 6 Kg/cm² including testing, labour, T&P and all complete fittings. 75mm dia |
| 641 | WATER SUPPLY PIPES AND FITTINGS - III |
| 642 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall 25mm dia nominal dia pipes |
| 643 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall 32mm dia nominal dia pipes |
| 644 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall 40mm dia nominal dia pipes |
| 645 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Concealed work, including cutting chases and making good the walls. 20mm dia nominal dia pipes |
| 646 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. (a) 15mm nominal bore |
| 647 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 (a) 15mm nominal bore |
| 648 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (a) 15mm nominal bore |
| 649 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 (a) 15mm nominal bore |
| 650 | Providing and fixing gun metal gate valve with wheel of approved quality. (a) 25mm dia nominal bore |
| 651 | Providing and fixing gun metal gate valve with wheel of approved quality. (d) 32mm dia nominal bore |
| 652 | Providing and fixing brass stop cock of approved quality. (a) 15 mm nominal bore |
| 653 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 654 | SCHEDULE OF QUANTITIES FOR INTERNAL & EXTERNAL SEWERAGE SYSTEM - IV |
| 655 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. (a) Pipes 80mm to 300mm diameter. |
| 656 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. (a) 100mm diameter |
| 657 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete (b) 150mm diameter |
| 658 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. (a) 100mm diameter S.W. Pipe |
| 659 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. (b) 150mm diameter S.W. Pipe |
| 660 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 150 x 100 mm size P type |
| 661 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 7.5 (i) For Sewer Line |
| 662 | 4- Garage |
| 663 | i- Civil Work |
| 664 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 665 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 666 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 667 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 668 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Plinth Band) |
| 669 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Lintel Band) |
| 670 | Ground Floor |
| 671 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Footing) |
| 672 | Ground Floor |
| 673 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Column |
| 674 | Ground Floor |
| 675 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Beam) |
| 676 | Ground Floor |
| 677 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) |
| 678 | Ground Floor |
| 679 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 680 | Ground Floor |
| 681 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 4 coarse sand) |
| 682 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :(1 cement : 4 coarse sand) (230mm wall) |
| 683 | Ground Floor |
| 684 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
| 685 | Ground Floor |
| 686 | 12mm thick plaster in inner walls with proportion of 1:6 cement & approved coarse sand |
| 687 | Ground Floor |
| 688 | 15mm thick plaster in Outer walls with proportion of 1:6 cement & approved coarse sand |
| 689 | Ground Floor |
| 690 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 691 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 692 | Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 693 | Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 694 | After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. |
| 695 | Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 696 | The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 697 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm.. |
| 698 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 699 | Ground Floor |
| 700 | One priming coat & one coat oil distemper on new work including supply of material, labour T&P etc. required for proper completion of the work. (Two Coat) |
| 701 | Ground Floor |
| 702 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 703 | Ground Floor |
| 704 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 705 | Making plinth protection 50 mm thick of cement concrete 1:3:6(1 cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 706 | Centering and shuttering including strutting, propping etc. and removal of form for Plinth Band |
| 707 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel Band |
| 708 | Ground Floor |
| 709 | Centering and shuttering including strutting, propping etc. and removal of form for Beam |
| 710 | Ground Floor |
| 711 | Centering and shuttering including strutting, propping etc. and removal of form for Slab |
| 712 | Ground Floor |
| 713 | Providing and fixing M.S. fan clamp type | or Il of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 714 | Providing and fixing circular’ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 715 | ii- Internal Electrical Work |
| 716 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 717 | Light Point |
| 718 | Fan Point |
| 719 | Exhaust Point |
| 720 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 721 | MCB CONTROL LIGHT POINTS |
| 722 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 723 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 724 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 725 | 2X4 sq. mm + 1X4 sq. mm earth wire |
| 726 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. |
| 727 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 728 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 729 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers) |
| 730 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 731 | 1 or 2 Module (75mmX75mm) |
| 732 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 733 | 3 pin , 5/6 amps socket outlet |
| 734 | Telephone socket outlet |
| 735 | TV antenna socket outlet |
| 736 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 737 | 25 mm |
| 738 | SUBHEAD -II - FITTINGS & FIXTURES |
| 739 | Supply & fixing of LED Tube Light witH Metal heavy duty Box type batten light fitting 1 x 22 watt suitable for upto 1X22W LED Polycarbonate tube light complete including tube etc on surface complete in all respects. |
| 740 | Supply, Installation, Testing and Commissioning of 9W (Nominal) Wall Bracket Light |
| 741 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 742 | 6 way, Double door |
| 743 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 744 | Single Pole |
| 745 | Single Pole Neutral |
| 746 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 747 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 748 | EARTHING |
| 749 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 750 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 751 | 5- Cycle Stand |
| 752 | i- Civil Work |
| 753 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 754 | Providing and laying in cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone ballast 40 mm nominal size) and curing complete, including cost of form- work, in foundation. 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 755 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. For mass concrete Foundations, footings, bases of columns, etc. for mass concrete |
| 756 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m² |
| 757 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Footing |
| 758 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 759 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution |
| 760 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 761 | Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete : 1.60 mm thick with zinc coating not less than 350 gm/m² |
| 762 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 763 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 764 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 765 | ii- Internal Electrical Work |
| 766 | Point wiring in PVC conduit, with piano type switch :- |
| 767 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 768 | Group C |
| 769 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. |
| 770 | 2 X 1.5 sq. mm+ 1 X 1.5 sq. mm earth wire. |
| 771 | 2 X 2.5 sq. mm+ 1 X 2.5 sq. mm earth wire. |
| 772 | Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 773 | Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 poles and earth metal enclosed plug top along with 20 amps. \\"C\\" curve, SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required.Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered): |
| 774 | S/F modular type blanking plate :- |
| 775 | Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 776 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: |
| 777 | 25 mm. |
| 778 | SUB HEAD (II):- DISTRIBUTION BOARDS & MCB's |
| 779 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts 'C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : single pole All kinds of soil |
| 780 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 781 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. |
| 782 | 40 Amps |
| 783 | Supplying and fixing following way, SP&N, sheet steel, MCB distribution board, 240 Von surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift : 6 way, Double door All kinds of soil |
| 784 | Supplying and fixing following way, horizontal type TP&N, sheet steel MCB distribution board, 415 Von surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). Deduct for not rolling with power roller of minimum 8 tonnes for bankingexcavated earth in layers not exceeding 20 cm in depth. |
| 785 | 4 way (4 + 12), Double door |
| 786 | SUB HEAD (III):- EARTHING SYSTEM |
| 787 | Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/ coke and salt as required.Providing and laying reinforced cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 788 | Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) Centering and shuttering including strutting, propping etc. and removal of form for |
| 789 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). |
| 790 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required.Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 791 | SUB HEAD (IV):- MISCELLANEOUS |
| 792 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.Jointing glazedstoneware pipes with stiff mixture of cement mortar in the proportion of (1:1). |
| 793 | SUPPLY OF LIGHTING FIXTURES |
| 794 | Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. |
| 795 | Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.. |
| 796 | 6- External Development work |
| 797 | i- Boundary wall |
| 798 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 799 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 800 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Footing excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. |
| 801 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Column excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. |
| 802 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Plinth Beam/Band excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. |
| 803 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Top Beam/Band excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. |
| 804 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 805 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :(1 cement : 4 coarse sand) (230mm wall) |
| 806 | 12mm thick plaster in Exterior walls with proportion of 1:6 cement & approved coarse sand |
| 807 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 808 | Finishing walls with Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 sqm) |
| 809 | Centering and shuttering including strutting, propping etc. and removal of form for Footing |
| 810 | Centering and shuttering including strutting, propping etc. and removal of form for Column |
| 811 | Centering and shuttering including strutting, propping etc. and removal of form for Plinth Band |
| 812 | Centering and shuttering including strutting, propping etc. and removal of form for Top Band |
| 813 | ii- Main Gate (2 Nos) |
| 814 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 815 | Earth work in cutting or in embankment in ordinary soil excavation to be in the form of a regular pits not exceeding 0.50m in depth and earth work in embankment to be in 20cm layers including ramming and dressing the surface to required levels and slopes and also including 1.5 m lift and 30m lead. The earth in form of cutting to be used as spoil banks within 50m distance as directed by the Engineer-in-Charge. |
| 816 | Providing and laying cement concrete in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, Including cost of form work. In Foundation and floors. |
| 817 | RCC work Providing and laying in position specified grade of reinforced cement concrete in Raft foundation, including the cost of centering, shuttering, finishing and excluding reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 818 | As in item 4 above but in Column with approved stone ballast.(Using 1:1.5:3 Mix concrete) (SOR 5.2.2, ii) |
| 819 | Upto Plinth Lvl. |
| 820 | Above Plinth Lvl. |
| 821 | As in item 4 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) (PWD 5.3) |
| 822 | Upto Plinth Lvl. |
| 823 | Above Plinth Lvl. |
| 824 | Brick work with class 150 bricks in Super Structure in Cement Coarse sand ( 1 Cement : 4 Coarse sand) including supply of all materials, labour, T & P and curing etc. required for proper completion of the work |
| 825 | Mild steel or iron in plain work such as reinforced concrete or reinforced ,brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 826 | 12mm Cement plaster with cement mortar in proportion of 1:6 cement & coarse sand of single coat for interior plastering upto floor two level including internal rounded angles chamfers, and rounded angles not exceeding 80mm in girth and finished even and smooth. |
| 827 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 828 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (M.S. GATE) |
| 829 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture (M.S. Gate) |
| 830 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 831 | Foundations, footings, bases of columns, etc. for mass concree |
| 832 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 833 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 834 | iii- Horticulture work |
| 835 | A- HARDSCAPE |
| 836 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement: 3 coarse sand), including the cost of required centering, shuttering complete. 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 837 | PLASTER WORKS |
| 838 | CEMENT PLASTER ON TOE WALLS |
| 839 | 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cmenet : 4 fine sand) |
| 840 | FINISHING WORK |
| 841 | NATURAL RIVER WASHED PEBBLES- WALKWAY |
| 842 | Providing & fixing of White River (Stone) Pebbles size of 2\\" to 2.50\\" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. |
| 843 | Natural river washed pebbles- RiegeSpecifications: Size: 10mm to 50mm (depending on foot traffic and desired appearance). Sub-base. Crushed gravel or sand, 50mm to 100mm thickness. Finish: Cleaned, washed pebbles with smooth, rounded edges. Color: Natural tones (beige, white, or mixed, depending on aesthetic preference). |
| 844 | MISCELLANEOUS ELEMENTS |
| 845 | WATERPROOFING (along building periphery and boundary wall) |
| 846 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5: 2 (5 parts integral crystalline slurry: 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry: 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm per coat |
| 847 | LED, 1-3W, IP65, Auto On/Off sensor, Polycrystalline panel |
| 848 | For connection to centralized solar power system |
| 849 | Spiking/hard ground installation (grouting, etc.) |
| 850 | Skilled labor for placing and testing |
| 851 | SOLAR LED BOLLARD LIGHT |
| 852 | 3W–7W LED, inbuilt solar panel, Li-ion battery, IP65, auto on/off |
| 853 | Concrete base with anchor bolts |
| 854 | Placement, alignment, testing |
| 855 | SOLAR LED ROCK GARDEN LIGHT |
| 856 | Solar LED Rock Garden Light (1.5W–3W) |
| 857 | Transportation & Unloading |
| 858 | Installation & Placement in Landscape |
| 859 | Misc. Accessories (glue, fasteners, etc.) |
| 860 | SOLAR LED SPOT LIGHT |
| 861 | Solar LED Ground Spot Light (7W) |
| 862 | Civil Work / Mounting Accessories |
| 863 | Transportation & Delivery |
| 864 | Installation Charges |
| 865 | Misc. (connectors, adhesives, etc.) |
| 866 | B- Softscape |
| 867 | TREES |
| 868 | Mimusops elengi (Maulsri) height 180-195 cm., well developed with thick stem in big in big size HDPE bag |
| 869 | Ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bag |
| 870 | Lagerstroemia indicia of height 90-105 cm. multibranched in polybag of size 25 cm |
| 871 | Plumeria rubra height 120-150 cm., 3-4 branches and thick stem in big size HDPE bag |
| 872 | Cassia fistula (Amaltash) height 120-135 cm. in big poly bag size 25 cm |
| 873 | Tabebuia sp. height 150-165 cm. in big polybag size 25 cm |
| 874 | Lagerstroemia flosreginae height 150-165 cm.in big poly bag size 25 cm |
| 875 | Bauhinia blakeana (Kachnar) height 120-150 cm. in big poly bag size 25 cm |
| 876 | Callistemon lanceolatus height 150-165 cm. in big poly bag size 25 cm |
| 877 | PALMS/BAMBOOS/AGAVE |
| 878 | Providing and displaying of Raphis Palm having ht. 75 cm to 90 cm with 15 to 18 equal suckers, well developed, full of fresh and healthy leaves from bottom to top in 35 cm PVC Pots/C.Pots & as per direction of the officer-in-charge. |
| 879 | Providing and Displaying Adenium Obesum well developed with fresh & healthy 4 to 5 branch 60 to 75 cm ht. in 40 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge. |
| 880 | Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. |
| 881 | Furcaira variegated well developed with fresh & healthy foliage 8 to 10 leaves in 30 cm Earthen Pot as per direction of the officer-in-charge. |
| 882 | Providing and Displaying Cycus revoluta specimen , having 45 to 50 fresh and healthy, leaves having 30cm to 35cm circumfrance of base stem well developed in 40 cm challi, as per direction of the officer-in-charge. |
| 883 | SHRUBS |
| 884 | Aglaonema Parrot Jungle plant (three in one), having ht. 30 cm and above with 20 to 25 leaves, well developed, fresh & healthy in 25 cm size of Earthen pot / Plastic pot. |
| 885 | Chandni dwarf of height 15 cm., well branched in earthen pot of size 25 cm |
| 886 | Providing and stacking of Tabernaemontana divaricata (Chandni double) of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 887 | Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 25 cm size of Earthen Pot / Plastic Pot. |
| 888 | Schefflera high colour plant (three in one), having ht. 25 cm to 30 cm, well developed with fresh and healthy foliage in 30 cm size of Earthen pot /Plastic pot. |
| 889 | Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag |
| 890 | Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge. |
| 891 | Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPE bag |
| 892 | Providing and Stacking of Adusha of ht. 30 cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge. |
| 893 | Providing and stacking of Ficus long Island of height 15 cm to 20 cm, full of branches and foliage in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. |
| 894 | Lemon grass of ht. 30cm with multi branches in Poly bag of size 20 cm |
| 895 | Providing and Stacking of Alovera well developed in earthen pot of size 20cm as per direction of the officer-in-charge. |
| 896 | Schefflera green 3 in 1 well developed with fresh, healthy and attractive foliage from having 45 cm to 60 cm ht. in 25 cm size Earthen pot/Plastic pot |
| 897 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. |
| 898 | Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 899 | Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. plant in 20 cm size of Earthen Pot/Plastic Pot |
| 900 | GROUND COVER |
| 901 | Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 902 | Providing and stacking of Daniella variegated, with 3 to 4 variegated leaves in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 903 | Philodendron Xanadu having 15 to 20 leaves, well developed with full of fresh & healthy leaves in 25 cm size of Earthen pot / Plastic pot. |
| 904 | Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm.. |
| 905 | Asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 20 cm size of Earthen Pot / Plastic Pot. |
| 906 | Syngonium miniature dwarf, having height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm.. |
| 907 | Portulaca hybrid in different colour with bloom well developed fresh & healthy in 20 cm Earthen Pot/Plastic Pot. |
| 908 | GRASS |
| 909 | Ophiopogon, Green/Black full of leaves in 15 cm size of Earthen Pot / Plastic Pot. |
| 910 | Ophiopogon jaburan ( variegated ),full of variegated leaves in 20 cm Earthen Pot/Plastic Pot |
| 911 | Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). |
| 912 | In rows 5 cm apart in both directions |
| 913 | With grass Turf (Parking & Seating) |
| 914 | CLIMBERS |
| 915 | Clerodendrum splendens of height 30 cm to 45 cm. in 20 cm size of Earthen pot/Plastic pot |
| 916 | Tecoma grandiflora of height 30 cm to 45 cm. in 20 cm size of Earthen pot/Plastic pot |
| 917 | iv- C.C. Road |
| 918 | Earth work in foundations in ordinary soil(loan clay or sand) including lift upto 1.5 m and lead upto 30m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the side of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30m from the foundation trenches. (where machine can not move). |
| 919 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone ballest 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. |
| 920 | First class brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc. |
| 921 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). |
| 922 | Providing and laying in position bitumen hot sealing compound for expansion joints etc.Using grade 'A' sealing compound. |
| 923 | V- Interlocking work |
| 924 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 925 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 926 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 927 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 928 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 929 | VI- Storm Water Drain |
| 930 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil |
| 931 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 932 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation & plinth level up to floor V level in all shapes and sizes in :(1 cement : 4 coarse sand) |
| 933 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement |
| 934 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 935 | VII- Street Light |
| 936 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 937 | 6 sq. mm 4 core |
| 938 | 16 sq. mm 4 core |
| 939 | 70 sq. mm 3-1/2 core |
| 940 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 941 | Upto 35 sq. mm |
| 942 | Above 35 sq. mm and upto 95 sq. mm |
| 943 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 944 | Upto 35 sq. mm |
| 945 | Above 35 sq. mm and upto 95 sq. mm |
| 946 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 947 | 6 sq. mm 4 core |
| 948 | 16 sq. mm 4 core (28 mm) |
| 949 | 70 sq. mm 3-1/2 core (38 mm) |
| 950 | Supply & fixing of 8 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 135mm and base plate 12mm thik) having 3mm thikness with Single Arm bracket 1 Mtr length on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. |
| 951 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 watt to 90 Watt. Confirming to IP 66 protection complete in all respect. CAT AAA |
| 952 | EXTERNAL LIGHT FEEDER PILLAR |
| 953 | Supply installing testing & commissioning of out door type street light feeder pillar (Distribution Panel) compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below. |
| 954 | Incoming |
| 955 | 63 Amp. 10 KA FP MCCB 1 No. |
| 956 | Suitable contractor and timer for down & dusk |
| 957 | 100 Amp. TPN Alu. Bus bar |
| 958 | Outgoing |
| 959 | 32 Amp. 10KA FP MCB 2 No. |
| 960 | 25 Amp. 10KA FP MCB 8 No. |
| 961 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 962 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 963 | Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 964 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 965 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 966 | Providing, laying and fixing following dia RCC pipe NP3 class (Medium duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 967 | 300 mm dia |
| 968 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 969 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 970 | VIII- Submersible Pump With Boring |
| 971 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. All Type Soil |
| 972 | 300mm dia (Upto 90M Below Ground Level) |
| 973 | 300mm dia (Beyond 90M To 150M Below Ground Level) |
| 974 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. |
| 975 | 150 mm nominal size dia |
| 976 | 200 mm nominal size dia |
| 977 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 978 | 200 mm nominal size dia |
| 979 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charge. |
| 980 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 981 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: |
| 982 | 150 mm dia |
| 983 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. |
| 984 | 150 mm dia |
| 985 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom ofpipe assembly of tubewell as per IS:2800 (part I). |
| 986 | 150 mm dia |
| 987 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc |
| 988 | 150 mm diameter |
| 989 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 990 | 50 mm dia nominal bore |
| 991 | 80 mm dia nominal bore |
| 992 | Water supply tanker of 5000 litre capacity |
| 993 | Supply of 80mm dia C.I Double Flanged ISI Mark sluice valve with hand wheel. |
| 994 | Supply of C.I Double flanged bend of 80 mm dia with all labour and material complete. |
| 995 | Supply of 80mm dia C.I Tee heavy quality with all labour & Material Complete. |
| 996 | Supply of Guru/Fibbing or equivalent make pressure guage |
| 997 | Supply of steel wire rope of 1/2\\" Size |
| 998 | Supply & Installation of 5.0 HP Submersible motar Pump with control panel, support wire etc. complete. |
| 999 | Supply and fixing of nylon jali around the slotted pipe complete as required. Up to 30 meter. |
| 1000 | Providing & Fixing of Control panel for submersible |
| 1001 | Poviding & Fixing Flat submersible cable 4 core 10 sqmm. Complete. |
| 1002 | XI- External Fire Fighting with Hydrent system |
| 1003 | Internal Hydrant System |
| 1004 | SITC of Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required Single headed Gunmetal |
| 1005 | SITC of Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal DSR- 27.16.1 |
| 1006 | SITC of Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: |
| 1007 | SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle MR |
| 1008 | Providing and fixing MS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser) |
| 1009 | 100mm dia |
| 1010 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:12585 (b) 20 mm nominal internal dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipmets on wall. (d)Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 1011 | Supply of Fire Man Axe. |
| 1012 | Providing and fixing weather proof standard Fire Duct Door complete in all respect for internal. |
| 1013 | SITC of Air cushion Tank (2000x1000)mm. |
| 1014 | SITC of Air Release Valve. |
| 1015 | Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. |
| 1016 | 150 mm |
| 1017 | SITC of Butterfly Valve complete with all respect. |
| 1018 | 150 mm |
| 1019 | Supply, Installation, Testing & Commissioning of Pressure Gauge with gauge cock |
| 1020 | Supply, Installation, Testing & Commissioning of Fire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. |
| 1021 | 2 way |
| 1022 | Supply, fixing , testing & commissioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump) (Make : Kirloskar/Mather+Platt) |
| 1023 | (a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. |
| 1024 | (b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class 'B' insulation for the above pump and flexible coupling with the pump. The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it's rated discharge at 65% of rated head. |
| 1025 | © Common bed plate of fabricated mild steel channel or cast iron type. |
| 1026 | (d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc. |
| 1027 | (e) Pressure switch for automatic operation of motor including necessary wiring upto control panel. |
| 1028 | (f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT's protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details Discharge :450 liter per minute Head : 35 meter |
| 1029 | Supply and fixing of ABC type (4 kg.) ISI Marked 1131 |
| 1030 | Supply and fixing of CO2 gas type (4.5 kg.) ISI Marked 1132 |
| 1031 | Supply and fixing of self glow type exit signage |
| 1032 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Per liters capcity. |
| 1033 | X- Hand Pump |
| 1034 | Supply of 110mm dia plain PVC.(6kg/sqcm) pressure. |
| 1035 | Supply of 110mm dia sloted PVC (6kg/sqcm) pressure. |
| 1036 | Supply of P.V.C. soket 125mm dia. |
| 1037 | Supply of end cap 110 mm dia. |
| 1038 | Providing necessary boaring T&P including making arrangement of water for boaring 200mm dia bore hole by Rig machine in all type of streta complete item. |
| 1039 | 30 metre B.G.L. |
| 1040 | Beyond 30 metre. |
| 1041 | Supply & fixing of nylon jalli around the slotted pipe complete as required. |
| 1042 | Lowering of 110mm dia Rogid P.v.c. pipe in bore hole including cutting jointing etc. complete. |
| 1043 | Providing & packing of coarse sand around the P.v.c.pipe. |
| 1044 | Supply of 32mm dia G.i.pipe B class with required fitting. ( SOR Aligarh - 2018 SI No 12 Ch- 23 ) |
| 1045 | Supply of India marka - II hand pump ISI marked with cylinder & connecting rods |
| 1046 | Installation of India marka - II hand pump over the bore hole as per direction of E/I |
| 1047 | Development of bore by manual labour till discharge of free from turbity complete item. |
| 1048 | XI- Cattle catcher |
| 1049 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 1050 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 1051 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 1052 | Providing & fixing T-Iron frames for door windows and ventilators of mild steel Tee - section joints mitered and welded with 15*3 mm lugs 10 cm long embededded in cement concrete block 15*10*10 cm of 1:3:6 (1cement : 3 course sand : 6 graded stone aggregate 20 cm nominal size) or with wooden plugs and screws or rawl plugs and screw or with fixing clips or with bolts and nuts as require including fixing of necessary but hinges and screws and applying a priming coal of approved steel primer. |
| 1053 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 1054 | 80 mm dia |
| 1055 | XI- Over Head Tank |
| 1056 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 1057 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) |
| 1058 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 1059 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 1060 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Footing) |
| 1061 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Plinth Band) |
| 1062 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)Column upto plinth |
| 1063 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Column |
| 1064 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Beam) |
| 1065 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) |
| 1066 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 1067 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 1068 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 1069 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12mm thick |
| 1070 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 2.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 1071 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 1072 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading |
| 1073 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 1074 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 1075 | Centering and shuttering including strutting, propping etc. and removal of form for Footing |
| 1076 | Centering and shuttering including strutting, propping etc. and removal of form for Plinth Band |
| 1077 | Centering and shuttering including strutting, propping etc. and removal of form for Column upto plinth |
| 1078 | Centering and shuttering including strutting, propping etc. and removal of form for Column |
| 1079 | Centering and shuttering including strutting, propping etc. and removal of form for Beam |
| 1080 | Centering and shuttering including strutting, propping etc. and removal of form for Slab |
| 1081 | Extra for shuttering in circular work (20% of respective centering and shuttering items) |
| 1082 | For Column |
| 1083 | For Beam |
| 1084 | For Slab |
| 1085 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) |
| 1086 | At Level 16.85m |
| 1087 | At Level 15.00m |
| 1088 | At Level 11.325m |
| 1089 | At Level 7.675m |
| 1090 | Providing & Fixing of Lighting Arrester With all Labour & T&P Complete. |
| 1091 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 : |
| 1092 | Inlet Pipe(100 mm diameter pipe) |
| 1093 | Outlet Pipe(150 mm diameter pipe) |
| 1094 | Overflow Pipe(150 mm diameter pipe) |
| 1095 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) 150 mm diameter |
| 1096 | Boughtout item |
| 1097 | 1- Singages |
| 1098 | 2- DIESEL GENERATING SETS 120 kva |
| 1099 | High Back Revolving Chair (High Back Chair, Chrome Plated Frame, PU Chrome Arm, Gas Lift, Chrome Base, Leatherette Tapestry) Knee Tilt |
| 1100 | Mid Back Revolving Chair (Medium Back Chair, Chrome Plated Frame, PU Chrome Arm, Gas Lift, Chrome Base, Leatherette Tapestry) Knee Tilt |
| 1101 | Low Back Revolving Chair (Medium Back Chair, Chrome Plated Frame, PU Chrome Arm, Gas Lift, Chrome Base, Leatherette Tapestry) Chrome Plated Base |
| 1102 | Conference Table, Particle board and MDF top W15000 X D3000 X H750 |
| 1103 | Podium stands 45 to 48 inches (114–122 cm) tall at the audience side. The reading surface typically measures 20 to 24 inches (51–61 cm) wide and 14 to 16 inches (36–41 cm) deep to comfortably hold a laptop, notes, or a microphone |
| 1104 | Stage for Podium |
| 1105 | Godrej Almirah Heavy-duty CRCA (Cold Rolled Close Annealed) steel, anti-rust powder coating, and premium locking systems. Standard 2-door models measure approximately 195-198 cm (H) x 90-91 cm (W) x 45-53 cm (D), and include multiple adjustable shelves, a concealed locker, and an integrated mirror. |
| 1106 | Wooden Almirah with double door open |
| 1107 | Office Table Executive Table, PLPB Top, Extruded Aluminium Profile W2400 X D2100 X H750 |
| 1108 | Solar System |
| 1109 | Aircondition |
| 1110 | Supply & installation of Split Direct Expansion Air Conditioners Suitable for operation on A/C supply single phase 50HZ 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitor, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High Wall Chorded/ Cordless) Suitable Capacity 3 Core sheathed/ PVC copper cable and a battery operated wireless remote unit. |
| 1111 | BEE 5STAR EER 3.4 (1.0 TR) |
| 1112 | BEE 5STAR EER 3.4 (1.5 TR) |
| 1113 | BEE 5STAR EER 3.4 (2.0 TR) |
| 1114 | Audio Video System For Meeting Room |
| 1115 | MEETING HALL |
| 1116 | Supply, Installation, Testing, and Commissioning of Premium branded Multimedia Projector, 3200 lumens, 15000:1 contrast Ratio, XGA resolution. including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1117 | Supply, Installation, Testing, and Commissioning of Premium branded Projector Ceiling Mount Kit including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1118 | Supply, Installation, Testing, and Commissioning of Premium branded 8’x6’ Self Lock Projection screen including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1119 | Supply, Installation, Testing, and Commissioning of Premium branded Two way Wall speaker 70v,100v, 30 watt. including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge |
| 1120 | Supply, Installation, Testing, and Commissioning of Premium branded Power amplifier 4 inputs, 1 aux, Multiple outputs - 70 V / 100 V and 8/4 ohm Temperature controlled forced front to back ventilation, directly stackable 120 watt including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge |
| 1121 | Supply, Installation, Testing, and Commissioning of Premium branded Wireless Gooseneck microphone set of four microphone with receiver including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1122 | Supply, Installation, Testing, and Commissioning of Premium branded Supporting Cables & connector, VGA Cable, Power Cable, speaker Cable, Stereo Cable, VGA and aux connector Plate including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1123 | Supply, Installation, of Premium branded Equipment Rack of standard size as per requirement including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1124 | Supply, Installation, Testing, and Commissioning of Premium branded laptop including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1125 | Supply, Installation, Testing, and Commissioning of Premium branded UPS with battery backup including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1126 | Supply, Installation, Testing, and Commissioning of Premium branded 32 Inches, 4K Ultra HD Smart LED Google TV, 2 Table Stand Base, 1 Remote Control, 1 AV IN Adapter, 1AC Cord, Wi-Fi, USB, Ethernet, HDMI Connectivity (18.2D x 72.5W x 47.9H Centimeters Centimeters) including material, labour, T&P etc. required for proper completion of work as per the direction of engineer in charge. |
| 1127 | CCTV Work |
| 1128 | SUB HEAD :1 CCTV Surveillance Work |
| 1129 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 1130 | 1 Run of Cable |
| 1131 | Supplying, installing, testing and commissioning of 8 port CAT6 jack panel loaded as per the connections required in jack panel. |
| 1132 | Supplying, installing, testing and commissioning of I/O(Information outlet ) for CAT6 Cable termination |
| 1133 | Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. |
| 1134 | Supply, Installation, Testing & Commissioning of CCTV Client Operator Station with 1 No.of 55” LED Display - Complete as per specifications & preferred make. Make: SONY/Samsung/LG |
| 1135 | Supplying, installing, testing and commissioning of HDMI to HDMI Cable. |
| 1136 | Supply installation testing and commissioning of 3m Cat-6 patch cord. |
| 1137 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm Dia |
| 1138 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 1139 | SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. |
| 1140 | SITC of 2 MP IR Fixed Bullet Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. |
| 1141 | SITC of 8 channel Network Video StoragE NVR suitabe to access data from any remote location including backup drive for 30days. |
| 1142 | GST AS PER APPLICABLE 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender