Tender For For Supply, Installation, Testing And Commissioning Of 800 Kva, 11/0.433 Kv Transformer With 11 Kv Rmu, Ht Metering Cubicle, Lt Panel, Apfc Capacitor Bank With Allied Electrical & Civil Works At Mcc-01 Panel At Goa Meat
Tender Overview
Project Description
Tender for For Supply, Installation, Testing And Commissioning Of 800 Kva, 11/0.433 Kv Transformer With 11 Kv Rmu, Ht Metering Cubicle, Lt Panel, Apfc Capacitor Bank With Allied Electrical & Civil Works At Mcc-01 Panel At Goa Meat , Part A - Supply & Installation Of Transformer, 11Kv Cable Laying Works , Supply & Laying Of 11 Kv, 3C X 185 Sq. Mm. Armoured Xlpe Cable With Stranded Compact Circular Aluminium Conductor, Screened With Extruded Semiconducting Compound In Combination With Copper Tape, Inner Pvc Sheath, Conforming To Is 7098 (Part 2), With Latest Amendments. , Supply & Installation Of 11Kv, Heat Shrinkable Outdoor End Termination Kit For Cable Size Of 3C X 185 Sq. Mm. , Supply & Installation Of 11Kv, Heat Shrinkable Indoor End Termination Kit For Cable Size Of 3C X 185 Sq. Mm. , Excavation Of Cable Trench For Laying Of 11 Kv, 3C X 185 Sq. Mm. Xlpe Cable By Conventional Open Trenching Method, Up To A Depth Of 1.2 M And Width Of 0.5 M, In All Types Of Soil Including Hard Laterite/Hard Strata, Complete As Required. , Backfilling Of Excavated Cable Trench After Laying Of 11 Kv Cable, Including Providing And Filling Suitable Excavated Earth Free From Stones, Debris And Other Deleterious Materials In Layers, Watering And Proper Compaction, Complete As Required And As Per Goa Electricity Department (Ged) Specifications , Supply And Laying Of Clean, Dry And Screened River Sand In Cable Trench For Providing Cushioning To The 11 Kv Cable, Including Spreading And Levelling To The Required Thickness Below And Above The Cable, Complete As Required And As Per Goa Electricity Department (Ged) Specifications , Supply & Laying Of Reinforced Cement Concrete Protective Covers Of Size 600 Mm Long × 250 Mm Wide × 50 Mm Thick, Capable Of Bearing A Load Of 135 Kg, And Covered With Earth/Sand Up To A Depth Of 0.15 M, Conforming To Is 1255 With Latest Amendments, At Non-Road Crossings, Complete As Required , Supply And Installation Of Ht Cable Route Markers Of Approved Design And Size, Indicating 11 Kv Cable And Direction Of Cable Route, At Suitable Intervals Along The Underground Cable Route And At All Bends, Crossings And Change Of Direction, Including Necessary Excavation, Fixing And Grouting In Cement Concrete, Complete As Required And As Per Goa Electricity Department (Ged) Specifications. , B - Transformer And Metering Cubicle Supply, Installation And Commissioning Of 800 Kva, 11/0.433 Kv, 3-Phase, 50 Hz, Oil-Immersed Power Transformer Continuous Duty Cycle, 11 Kv/433V, 3 Phase, 50Hz, Dyn-11 Vector Group, Step Down, Outdoor Type, Copper Wound, Complete With On Load Tap Changer & With All Accessories, Including Winding Temperature Scanner With Alarm And Trip Contact, Fittings And Conforming To Specifications. Tap Changing Range Shall Be +5% To -15 % In Steps Of 2.5%. (21 Taps Or Less) The Scope Shall Include Rtcc & Protection Panel. The Transformer Shall Have Cable Box For 11 Kv Xple Cable On Ht Side & Cable Box On The Medium Voltage Side. The Transformer Shall Meet Ecbc Norms On No Load& On Load Power Losses. , Supply Installation Testing and Commissioning of 11 Kv, 630 A, 21 Ka, Outdoor, Non-Extensible Rmu Panel Comprising 1 No. Vcb + 2 Nos. Lbs, Complete With Suitable Protection, Interlocking, Operating Mechanism, Cable Termination Provisions, Metering/Protection Accessories Wherever Required, And All Associated Fittings. The Rmu Shall Be Complete With Suitable Reinforced Cement Concrete Plinth/Foundation And Cable Tray/Trench From The Existing Ht Yard To The Rmu Location, Including All Necessary Civil Works, Supports, Excavation, Backfilling And Reinstatement, Complete In All Respects As Required And Conforming To The Applicable Goa Electricity Department (Ged) Specifications And Relevant Is/Iec Standards. The Rmu Shall Be Suitable For 11 Kv System Voltage And Have A Short-Circuit Withstand Rating Of 21 Ka For 3 Seconds. , Supply, Installation, Testing And Commissioning Of 11 Kv Ht Metering Cubicle (Compact Type), Duly Approved By Ged/Mrt/Licensee, Fabricated From Minimum 2.0 Mm (14 Swg) Ms Sheet With Suitable Angle/Channel Supports, Powder Coated/Epoxy Painted, Complete With 25 × 6 Mm Copper Busbar, Sealing Arrangement, Heavy-Duty Locking And Interlocked Ct/Pt And Meter Doors. The Cubicle Shall Be Provided With 3 Nos. 11 Kv Cts Of Approved Ratio, 15 Va, Class 0.5S And Suitable 11 Kv Pts Of Ratio 11,000/√3 V / 110/√3 V, 50 Va, Class 0.5S, With Epoxy Insulation, Suitable Terminal Blocks, Metering Wiring And Provisions For Incoming/Outgoing Cable Termination And Approved Trivector Meter. Scope Includes Proper Insulation Of 11 Kv Ct/Pt Connections And Copper Busbars, Testing, Calibration, Authentication And Sealing By Mrt/Ged/Licensee, Complete With All Necessary Accessories And Commissionin , C - Earthing Supply, Installation, Testing And Commissioning Of Maintenance-Free Chemical Earthing System Comprising 3.0 M Long × 17.2 Mm Dia. Low-Carbon Steel Rod With Minimum 250 Micron Molecular Copper-Bonded Coating, Installed In A 4.0 M Deep Bore With 100 Mm Od Gi Pipe And 50 Kg Approved Earth-Enhancing Compound, Including Earthing Connections, Clamps And Accessories, 600 × 600 Mm Masonry Inspection Chamber With Ci Cover, Pit Identification And Earth-Resistance Testing With Test Report, Complete As Per Is 3043 And Applicable Ged Requirements. 1.0 Ohms Etc. , Supply & Laying Of 50 × 6 Mm Hd Gi Earthing Strip, Including Cutting, Bending, Jointing, Welding/Bolting, Laying In Trench Or On Surface As Required, Connection To Earth Electrodes/Equipment And Application Of Suitable Anti-Corrosive Protective Coating At Joints, Complete With All Necessary Clamps, Nuts, Bolts, Supports, Materials, Labour And Testing, As Per Is 3043 And Ged Specifications. , Supply And Laying Of 50 Mm × 6 Mm Copper Earthing Strip, Including Cutting, Bending, Jointing With Suitable Copper Connectors/Bolts, Clamps, Supports And Necessary Accessories, Complete As Required And As Per Is 3043 And Applicable Ged Requirements , Supply And Installation Of Ms Channels And Angles For Cable Supports, Including Cutting, Drilling, Welding, Fabrication, Fixing With Necessary Clamps, Bolts, Nuts And Other Accessories, Complete With One Coat Of Suitable Anti-Corrosive Primer And Two Coats Of Protective Paint, As Required For The Cable Installation , D - Lt Cabliling Supply, Installation, Testing And Commissioning Of 16C × 2.5 Sq. Mm. Copper Control Cable For Rtcc, Including Cable Laying, Dressing, Termination With Suitable Glands And Lugs, Ferruling, Identification, Testing ( For Rtcc) , Supply, Installation, Testing & Commissioning Of Control Cabling 10C X 2.5 Sq.Mm (For Protection) , Supply, Installation, Testing & Commissioning Of Control Cabling 4C X 2.5 Sq.Mm. (For Rtcc) , Supply And Laying Of 1.1 Kv, 3.5C × 300 Sq. Mm. Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Cable, In Ground Or On Cable Trays, Including Necessary Saddles/Clamps, Cable Ties, Dressing, Identification And Labelling At Both Ends, Complete With All Necessary Accessories, From The Existing Compact Substation 1600 A Acb To The Existing 1000 A Acb, Complete As Required. , Supply And Installation Of Cable End Termination For 3.5C × 300 Sq. Mm. Xlpe Armoured Cable, Comprising Suitable Double-Compression Brass Glands, Heavy-Duty Cable Al Lugs And All Necessary Accessories, Including Gland Fixing, Crimping, Termination, Earthing Of Cable Armour And Insulation/Continuity Testing, Complete As Required , Supply And Installation Of 600 Mm Wide × 100 Mm Deep × 2.0 Mm Thick Hot-Dip Galvanised (Hdgi) Perforated Cable Tray Es , E - Miscellaneous Supply And Laying Of Cement Concrete For Foundations Of Fencing, Transformer, Vcb, Lt Panel And Ht Metering Cubicle, Including Excavation, Preparation Of Base, Reinforcement, Formwork, Levelling, Finishing, Curing And All Necessary Materials, Labour And Accessories, Complete As Required , Supply And Fixing Of Centering And Shuttering For Foundations Of Various Electrical Equipment, Including Necessary Supports, Staging, Bracing, Alignment, Levelling, Erection And Removal After Completion Of Concreting, , Supply And Application Of 15 Mm Thick Cement Plaster In Cement Mortar To The Exposed Surfaces Of Equipment Foundations, Including Surface Preparation, Finishing, Curing And All Necessary Materials, Labour And Accessories, Complete As Required , Providing And Fixing Round-Bottom Fire Bucket Of 9-Litre Capacity, Conforming To Is 2546, Made Of 24 Swg Gi Sheet, With Bottom Handle, Painted White Inside And Red Outside With Fire Marking, Complete With Suitable Stand/Wall Hook And All Necessary Accessories. , Providing And Fixing Danger Boards Of Size 300 Mm × 200 Mm And Electrical Safety Chart Of A0 Size, With Suitable Warning/Safety Markings And Lettering, Made Of Durable Weather-Resistant Material, Including Necessary Fixing Arrangements, , Supplying And Laying, Including Excavation, Of Reinforced Cement Concrete (Rcc) Pipe Conforming To Is 458:2003, Np-2 Class, 150 Mm Internal Diameter, In Proper Line, Level And Slope, Including Jointing With Suitable Collars In Cement Mortar 1:2, Alignment, Bedding, Backfilling, Curing And All Necessary Materials, Labour And Accessories, Complete As Required. , Supply And Installation Of Ms Channels And Angles For Cable Supports, Including Cutting, Drilling, Welding, Fabrication, Fixing With Necessary Clamps, Bolts, Nuts And Other Accessories, Complete With One Coat Of Suitable Anti-Corrosive Primer And Two Coats Of Protective Paint, As Required For The Cable Installation , Supply And Stringing Of Acsr Conductor Of Suitable Size (Raccoon/Dog), As Required For Rearrangement/Refurbishment Of Existing 4-Pole Dp Structure, Including Necessary Clamps, Connectors, Binding Materials, Hardware And Accessorie , Miscellaneous Repair And Refurbishment Of Existing 4-Pole Dp Structure, Including Removal Of Existing Ct & Pt, Repair/Replacement Of Damaged Structural Members, Concrete Muffing, Dismantling And Reconnection Of Jumpers, Repair/Servicing Of Air Break (Ab) Switch With H.G. Fuses Mounted On Ms/Rcc Poles, Tightening/Replacement Of Necessary Hardware, Cleaning And Painting, And All Other Minor/Major Repairs , Supplying Standard First-Aid Box Complete With Antiseptic Cream, Suitable Medicines For Minor Burns And Wounds, Crepe Bandage, Gauze Bandage, Ready-To-Use Adhesive Bandages (Band-Aid Or Equivalent), Medical Adhesive Tape, Scissors, Antiseptic Solution (Savlon Or Equivalent) And Other Essential First-Aid Items, Complete As Require , Supplying And Fixing Pvc Synthetic Elastomer Electrical Insulating Mat, Class C, Conforming To Is 15652:2006, Suitable For Use Up To 11 Kv, Of Minimum 2.5 Mm Thickness And Size 1 M × 1 M, Cpri Tested And Supplied With Valid Test Certificates, Complete As Required. , Supplying & Erecting Carbon Dioxide (Co2) Automatic Diffusing Fire Extinguisher Of 10 Kg. Capacity Cartridge Type Conf. To Is 2878 Complete Erected With Necessary Clamp Made Front 50X6 Mm. M. S. Flat With Nut & Bolts Grouted On Wall Above Transformer , Providing One Pair Of Tested Electrical Insulating Rubber Gloves Suitable For Working On 11 Kv Systems, Conforming To The Applicable Bis Standard, Cpri Tested And Supplied With A Valid Test Certificate , F - Approvals And Liaison Work Preparation And Submission Of Documents/File To The Electrical Inspector/Ged And Obtaining Necessary Approvals/Licences For The Proposed 11 Kv Ht Metering Installation, Including Approval For Additional 300 Kva Load, Approval Of Estimate, Rio Approval, Mrt Testing/Approval And Permission For Charging/Energisation... , Testing And Commissioning Of All Ht Units And Associated Equipment, Including Submission Of All Required Test Reports, Test Certificates And Documentation, Coordination For Mrt Testing And Obtaining Necessary Mrt Approval, And Commissioning/Energisation Of The Ht Installation , Part B - Annex. Lv Panel & Capacitor Bank Supply, Fabrication, Assembly, Installation, Testing And Commissioning (Sitc) Of An Extensible Low Voltage (Lt) Panel/Main Switchboard, Designed And Manufactured In Accordance With Iec 61439-1 & 2, With Provision For Future Extension From Either The Left Or Right-Hand Side, As Per The Approved Design And Site Installation Requirements , Supply Installation Testing and Commissioning of 200 Kvar Automatic Power Factor Correction (Apfc) Capacitor Bank, With Provision For Installation At The Main Lt Panel/Sub-Panel, As Per Requirement, Complete With Apfc Controller, Capacitor-Duty Contactors, Detuned Reactors, Protection, Switching Devices And All Necessary Accessories, Complete As Required
BOQ
| Sl. No. | Item Description |
| 1 | PART A - Supply & Installation of Transformer, 11KV Cable Laying works |
| 2 | Supply & laying of 11 kV, 3C x 185 sq. mm. armoured XLPE cable with stranded compact circular aluminium conductor, screened with extruded semiconducting compound in combination with copper tape, inner PVC sheath, conforming to IS 7098 (Part 2), with latest amendments. |
| 3 | Supply & installation of 11kV, Heat shrinkable outdoor end termination kit for cable size of 3C x 185 Sq. mm. |
| 4 | Supply & installation of 11kV, Heat shrinkable indoor end termination kit for cable size of 3C x 185 Sq. mm. |
| 5 | Excavation of cable trench for laying of 11 kV, 3C x 185 sq. mm. XLPE cable by conventional open trenching method, up to a depth of 1.2 m and width of 0.5 m, in all types of soil including hard laterite/hard strata, complete as required. |
| 6 | Backfilling of excavated cable trench after laying of 11 kV cable, including providing and filling suitable excavated earth free from stones, debris and other deleterious materials in layers, watering and proper compaction, complete as required and as per Goa Electricity Department (GED) specifications |
| 7 | Supply and laying of clean, dry and screened river sand in cable trench for providing cushioning to the 11 kV cable, including spreading and levelling to the required thickness below and above the cable, complete as required and as per Goa Electricity Department (GED) specifications |
| 8 | Supply & laying of RCC protective covers of size 600 mm long × 250 mm wide × 50 mm thick, capable of bearing a load of 135 kg, and covered with earth/sand up to a depth of 0.15 m, conforming to IS 1255 with latest amendments, at non-road crossings, complete as required |
| 9 | Supply and installation of HT cable route markers of approved design and size, indicating “11 kV CABLE” and direction of cable route, at suitable intervals along the underground cable route and at all bends, crossings and change of direction, including necessary excavation, fixing and grouting in cement concrete, complete as required and as per Goa Electricity Department (GED) specifications. |
| 10 | B - Transformer and Metering CubicleSupply, Installation and commissioning of 800 kVA, 11/0.433 kV, 3-Phase, 50 Hz, Oil-Immersed Power Transformer continuous duty cycle, 11 kV/433V, 3 phase, 50Hz, Dyn-11 vector group, step down, outdoor type, copper wound, complete with ON load tap changer & with all accessories, including winding temperature scanner with alarm and trip contact, fittings and conforming to specifications. Tap changing range shall be +5% to -15 % in steps of 2.5%. (21 taps or less)The scope shall include RTCC & Protection Panel. The transformer shall have cable box for 11 kV XPLE cable on HT side & Cable Box on the Medium voltage side. The transformer shall meet ECBC norms on NO LOAD& ON LOAD power losses. |
| 11 | SITC of 11 kV, 630 A, 21 kA, outdoor, non-extensible RMU panel comprising 1 No. VCB + 2 Nos. LBS, complete with suitable protection, interlocking, operating mechanism, cable termination provisions, metering/protection accessories wherever required, and all associated fittings. The RMU shall be complete with suitable RCC plinth/foundation and cable tray/trench from the existing HT yard to the RMU location, including all necessary civil works, supports, excavation, backfilling and reinstatement, complete in all respects as required and conforming to the applicable Goa Electricity Department (GED) specifications and relevant IS/IEC standards. The RMU shall be suitable for 11 kV system voltage and have a short-circuit withstand rating of 21 kA for 3 seconds. |
| 12 | Supply, installation, testing and commissioning of 11 kV HT Metering Cubicle (compact type), duly approved by GED/MRT/Licensee, fabricated from minimum 2.0 mm (14 SWG) MS sheet with suitable angle/channel supports, powder coated/epoxy painted, complete with 25 × 6 mm copper busbar, sealing arrangement, heavy-duty locking and interlocked CT/PT and meter doors. The cubicle shall be provided with 3 Nos. 11 kV CTs of approved ratio, 15 VA, Class 0.5S and suitable 11 kV PTs of ratio 11,000/√3 V / 110/√3 V, 50 VA, Class 0.5S, with epoxy insulation, suitable terminal blocks, metering wiring and provisions for incoming/outgoing cable termination and approved trivector meter. Scope includes proper insulation of 11 kV CT/PT connections and copper busbars, testing, calibration, authentication and sealing by MRT/GED/Licensee, complete with all necessary accessories and commissionin |
| 13 | C - Earthing Supply, installation, testing and commissioning of maintenance-free chemical earthing system comprising 3.0 m long × 17.2 mm dia. low-carbon steel rod with minimum 250 micron molecular copper-bonded coating, installed in a 4.0 m deep bore with 100 mm OD GI pipe and 50 kg approved earth-enhancing compound, including earthing connections, clamps and accessories, 600 × 600 mm masonry inspection chamber with CI cover, pit identification and earth-resistance testing with test report, complete as per IS 3043 and applicable GED requirements. < 1.0 ohms etc. |
| 14 | Supply & laying of 50 × 6 mm HD GI earthing strip, including cutting, bending, jointing, welding/bolting, laying in trench or on surface as required, connection to earth electrodes/equipment and application of suitable anti-corrosive protective coating at joints, complete with all necessary clamps, nuts, bolts, supports, materials, labour and testing, as per IS 3043 and GED specifications. |
| 15 | Supply and laying of 50 mm × 6 mm copper earthing strip, including cutting, bending, jointing with suitable copper connectors/bolts, clamps, supports and necessary accessories, complete as required and as per IS 3043 and applicable GED requirements |
| 16 | Supply and installation of MS channels and angles for cable supports, including cutting, drilling, welding, fabrication, fixing with necessary clamps, bolts, nuts and other accessories, complete with one coat of suitable anti-corrosive primer and two coats of protective paint, as required for the cable installation |
| 17 | D - LT Cabliling Supply, installation, testing and commissioning of 16C × 2.5 sq. mm. copper control cable for RTCC, including cable laying, dressing, termination with suitable glands and lugs, ferruling, identification, testing ( FOR RTCC) |
| 18 | Supply, Installation, Testing & Commissioning of Control Cabling10C x 2.5 Sq.mm (For Protection) |
| 19 | Supply, Installation, Testing & Commissioning of Control cabling4C x 2.5 Sq.mm. (for RTCC) |
| 20 | Supply and laying of 1.1 kV, 3.5C × 300 sq. mm. aluminium conductor, XLPE insulated, PVC sheathed, armoured cable, in ground or on cable trays, including necessary saddles/clamps, cable ties, dressing, identification and labelling at both ends, complete with all necessary accessories, from the existing Compact Substation 1600 A ACB to the existing 1000 A ACB, complete as required. |
| 21 | Supply and installation of cable end termination for 3.5C × 300 sq. mm. XLPE armoured cable, comprising suitable double-compression brass glands, heavy-duty cable AL lugs and all necessary accessories, including gland fixing, crimping, termination, earthing of cable armour and insulation/continuity testing, complete as required |
| 22 | Supply and installation of 600 mm wide × 100 mm deep × 2.0 mm thick hot-dip galvanised (HDGI) perforated cable tray es |
| 23 | E - Miscellaneous Supply and laying of cement concrete for foundations of fencing, transformer, VCB, LT panel and HT metering cubicle, including excavation, preparation of base, reinforcement, formwork, levelling, finishing, curing and all necessary materials, labour and accessories, complete as required |
| 24 | Supply and fixing of centering and shuttering for foundations of various electrical equipment, including necessary supports, staging, bracing, alignment, levelling, erection and removal after completion of concreting, |
| 25 | Supply and application of 15 mm thick cement plaster in cement mortar to the exposed surfaces of equipment foundations, including surface preparation, finishing, curing and all necessary materials, labour and accessories, complete as required |
| 26 | Providing and fixing round-bottom fire bucket of 9-litre capacity, conforming to IS 2546, made of 24 SWG GI sheet, with bottom handle, painted white inside and red outside with “FIRE” marking, complete with suitable stand/wall hook and all necessary accessories. |
| 27 | Providing and fixing danger boards of size 300 mm × 200 mm and electrical safety chart of A0 size, with suitable warning/safety markings and lettering, made of durable weather-resistant material, including necessary fixing arrangements, |
| 28 | Supplying and laying, including excavation, of reinforced cement concrete (RCC) pipe conforming to IS 458:2003, NP-2 class, 150 mm internal diameter, in proper line, level and slope, including jointing with suitable collars in cement mortar 1:2, alignment, bedding, backfilling, curing and all necessary materials, labour and accessories, complete as required. |
| 29 | Supply and installation of MS channels and angles for cable supports, including cutting, drilling, welding, fabrication, fixing with necessary clamps, bolts, nuts and other accessories, complete with one coat of suitable anti-corrosive primer and two coats of protective paint, as required for the cable installation |
| 30 | Supply and stringing of ACSR conductor of suitable size (Raccoon/Dog), as required for rearrangement/refurbishment of existing 4-pole DP structure, including necessary clamps, connectors, binding materials, hardware and accessorie |
| 31 | Miscellaneous repair and refurbishment of existing 4-pole DP structure, including removal of existing CT & PT, repair/replacement of damaged structural members, concrete muffing, dismantling and reconnection of jumpers, repair/servicing of Air Break (AB) switch with H.G. fuses mounted on MS/RCC poles, tightening/replacement of necessary hardware, cleaning and painting, and all other minor/major repairs |
| 32 | Supplying standard first-aid box complete with antiseptic cream, suitable medicines for minor burns and wounds, crepe bandage, gauze bandage, ready-to-use adhesive bandages (Band-Aid or equivalent), medical adhesive tape, scissors, antiseptic solution (Savlon or equivalent) and other essential first-aid items, complete as require |
| 33 | Supplying and fixing PVC synthetic elastomer electrical insulating mat, Class C, conforming to IS 15652:2006, suitable for use up to 11 kV, of minimum 2.5 mm thickness and size 1 m × 1 m, CPRI tested and supplied with valid test certificates, complete as required. |
| 34 | Supplying & erecting Carbon Dioxide (CO2) automatic diffusing fire extinguisher of 10 kg. Capacity Cartridge type conf. To IS 2878Complete erected with necessary clamp made front 50x6 mm. M. S. flat with nut & bolts grouted on wall above transformer |
| 35 | Providing one pair of tested electrical insulating rubber gloves suitable for working on 11 kV systems, conforming to the applicable BIS standard, CPRI tested and supplied with a valid test certificate |
| 36 | F - Approvals and Liaison workPreparation and submission of documents/file to the Electrical Inspector/GED and obtaining necessary approvals/licences for the proposed 11 kV HT metering installation, including approval for additional 300 kVA load, approval of estimate, RIO approval, MRT testing/approval and permission for charging/energisation... |
| 37 | Testing and commissioning of all HT units and associated equipment, including submission of all required test reports, test certificates and documentation, coordination for MRT testing and obtaining necessary MRT approval, and commissioning/energisation of the HT installation |
| 38 | PART B - Annex. LV panel & Capacitor BankSupply, Fabrication, Assembly, Installation, Testing and Commissioning (SITC) of an extensible Low Voltage (LT) Panel/Main Switchboard, designed and manufactured in accordance with IEC 61439-1 & 2, with provision for future extension from either the left or right-hand side, as per the approved design and site installation requirements |
| 39 | SITC of 200 kVAr Automatic Power Factor Correction (APFC) Capacitor Bank, with provision for installation at the Main LT Panel/Sub-Panel, as per requirement, complete with APFC controller, capacitor-duty contactors, detuned reactors, protection, switching devices and all necessary accessories, complete as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender