Tender For Supply Installation Testing and Commissioning of Hybrid Thermal Solar Vrv/Vrf Air Conditioning Plant In Gas Hydrate Building At Csir-Ngri
Tender Value
1.98 Crore
Estimated cost
Bid Submission
07 Nov 2026
9 days left
EMD
3.96 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of Hybrid Thermal Solar Vrv/Vrf Air Conditioning Plant In Gas Hydrate Building At Csir-Ngri
BOQ
| Sl. No. | Item Description |
| 1 | Description of Items : |
| 2 | Supply of Hybrid VRF Outdoor Unit: Supply of Modular type Hybrid VRF outdoor unit equipped with highly efficient twin rotary inverter compressors with all inverter type compressor only, special acryl precoated heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting,with outdoor unit. Refrigerant Should be R410A. Each system shall have Hybrid Climate solar smart Panel Systems consisting of tracking parabolic concentrative solar reflectors , Painted Aluminum enclosure, 24V Power Systems, removable safety glass cover, selectable refrigerant type temperature control with temperature sensors, computer controller and motor assembly giving Renewable energy source . Each system should have provision to combine maximum 3 nos. panels in each outdoor unit.Panel / outdoor / indoor unit should be compatable to each other (single phase / three phase ). 20- Top Discharge (Outdoor Units shall be fixed on the floor with required number of anti vibration heavyduty rubber pads and all the required accessories comes under the scope of contractor) |
| 3 | Supply of Hybrid VRF Outdoor Unit: Supply of Modular type Hybrid VRF outdoor unit equipped with highly efficient twin rotary inverter compressors with all inverter type compressor only, special acryl precoated heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting,with outdoor unit. Refrigerant Should be R410A. Each system shall have Hybrid Climate solar smart Panel Systems consisting of tracking parabolic concentrative solar reflectors , Painted Aluminum enclosure, 24V Power Systems, removable safety glass cover, selectable refrigerant type temperature control with temperature sensors, computer controller and motor assembly giving Renewable energy source . Each system should have provision to combine maximum 3 nos. panels in each outdoor unit.Panel / outdoor / indoor unit should be compatable to each other (single phase / three phase ) 18 HP - Top Discharge (Outdoor Units shall be fixed on the floor with required number of anti vibration heavyduty rubber pads and all the required accessories comes under the scope of contractor) |
| 4 | Supply of VRF Indoor Unit: Supply of VRF type indoor units with compact cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamicaly balanced and designed for silent operation. The unit shall be with non inflamable insulation. The unit shall be with cordless remote Hi-Wall unit and capacity of not less than 1.0 HP |
| 5 | Supply of VRF Indoor Unit: Supply of VRF type indoor units with compact cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamicaly balanced and designed for silent operation. The unit shall be with non inflamable insulation. The unit shall be with cordless remote Hi-Wall unit and capacity of not less than 1.25 HP |
| 6 | Supply and Installation of VRF Indoor Unit: Supply of VRF type indoor units with compact cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamicaly balanced and designed for silent operation. The unit shall be with non inflamable insulation. The unit shall be with cordless remote Hi-Wall unit and capacity of not less than 1.7 HP |
| 7 | Supply and Installation of VRF Indoor Unit: Supply of VRF type indoor units with compact cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamicaly balanced and designed for silent operation. The unit shall be with non inflamable insulation. The unit shall be with cordless remote Hi-Wall unit and capacity of not less than 2.0 HP |
| 8 | Supply and Installation of VRF Indoor Unit: Supply of VRF type indoor units with compact cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamicaly balanced and designed for silent operation. The unit shall be with non inflamable insulation. The unit shall be with cordless remote Hi-Wall unit and capacity of not less than 2.5 HP |
| 9 | Supply and installation of VRF Indoor Unit: Supply of VRF type indoor units with compact cooling coil, electronic expansion valve and multispeed fan motor, The blower shall be dynamicaly balanced and designed for silent operation. The unit shall be with non inflamable insulation. The unit shall be with cordless remote Hi-Wall unit and capacity of not less than 3.0 HP Fan Coil Units |
| 10 | Installation,testing and commissioning of VRF outdoor units: Copper pipeing with insulation, Brazing work,Indoor unit installtion laying Control cables with pvc & conduit Laying, Indoor unit copper pipeing Connection , Outdoor unit copper pipeing Connection N2 flushing, N2 pressure testing work. |
| 11 | Supply and Installation of Refnet Joints, Indoor Joint |
| 12 | Supply and installation of 20G Refrigerant Copper piping insulated with 13/19 mm thick Nitrile Rubber Tubular insulation wrapped with FRP tape. Requried threaded rod and slotted channel supports and copper pipe size of not less than 28.6 mm |
| 13 | Supply and installation of 20G Refrigerant Copper piping insulated with 13/19 mm thick Nitrile Rubber Tubular insulation wrapped with FRP tape. Requried threaded rod and slotted channel supports and copper pipe size of not less than 22.2 mm |
| 14 | Supply and installation of 20G Refrigerant Copper piping insulated with 13/19 mm thick Nitrile Rubber Tubular insulation wrapped with FRP tape. Requried threaded rod and slotted channel supports and copper pipe size of not less than 15.9 mm |
| 15 | Supply and installation of 20G Refrigerant Copper piping insulated with 13/19 mm thick Nitrile Rubber Tubular insulation wrapped with FRP tape. Requried threaded rod and slotted channel supports and copper pipe size of not less than 12.7 mm |
| 16 | Supply and installation of 20G Refrigerant Copper piping insulated with 13/19 mm thick Nitrile Rubber Tubular insulation wrapped with FRP tape. Requried threaded rod and slotted channel supports and copper pipe size of not less than 9.5 mm |
| 17 | Supply and installation of 20G Refrigerant Copper piping insulated with 13/19 mm thick Nitrile Rubber Tubular insulation wrapped with FRP tape. Requried threaded rod and slotted channel supports and copper pipe size of not less than 6.4 mm |
| 18 | Supply and laying of control cabling in PVC conduit between the Indoor unit and outdoor units 2C X 1.5 Sqmm ( For VRF Units) |
| 19 | Supply and installation of PVC Drain pipe with 9mm thick nitrile rubber insulation complete with necessary fittings, bends, supports etc. 25mm |
| 20 | Supply and installation of PVC Drain pipe with 9mm thick nitrile rubber insulation complete with necessary fittings, bends, supports etc. 32mm |
| 21 | Supply and installation of PVC Drain pipe with 9mm thick nitrile rubber insulation complete with necessary fittings, bends, supports etc. 40mm and additional drain piping for clubbing all drain lines and to provide it for plants through gravity |
| 22 | Supply and installation GI Perforated Cable tray with cover and with complete supports etc,. The tray shall be mounted by means of threaded rod supports. 150 x 100 x 1.6mm Thick without cover |
| 23 | Nitrogen Pressure Testing & Vaccumissing the entire VRF system |
| 24 | Additional Refrigerant gas charging at site for VRF system as per the site condition |
| 25 | Supply and installation of MS Stand for outdoor unit |
| 26 | Lifting,shifting and positioning of the VRF outdoor units on Terrace level with Chain Pulley/ Crane arrangement. |
| 27 | Lifting, shifting and positioning of indoor units and the other ancillary materials like copper piping,electric cables,pvc pipes, ducting etc. |
| 28 | Dismantling VRF units disconnecting and removing the indoor units, refrigerant lines, and other components of the system. |
| 29 | Recovery of refrigerant VRF units including Empty cylinders |
| 30 | Buy back of old system Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓