Public Administrative Department Local Bodies Closing in 1 days TDR #58187787

Tender For Repairing And Maintenance Of Pa System Of Disaster Management Center, Humayun Lane And Babu Dham Housing Complex.

Issued by Local Bodies · New Delhi, Delhi
Tender Value
9.56 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
1 days left
EMD
19136
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairing And Maintenance Of Pa System Of Disaster Management Center, Humayun Lane And Babu Dham Housing Complex.

BOQ

Name of Work:- Repairing and maintenance of PA system of Disaster management center, Humayun lane and Babu dham housing complex.
Sl. No. Item Description
1Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required.
2Providing and fixing of tabletop microphone, featuring built-in loudspeaker, microphone ON/OFF button with red LED/light-ring indication, built-in headphone volume control and two 3.5 mm stereo headphone sockets, with 2 m cable terminated with 8-pin connector for loop-through connection. The unit shall have frequency response of 200Hz–12.5kHz, nominal acoustic input of 85 dBSPL,tabletop mounting, dimensions approximately 54×136 × 138 mm, microphone stem length 318 mm with as per the direction and entire satisfaction of Fire officer.
3Providing and fixing of Conference Control Unit, designed to control and power upto 50 discussion units,with provision for upto 6 simultaneous active microphones, 3-band equalizer with control sat250Hz,2 kHz and8 kHz,microphone and auxiliary inputs, headphone output with volume control, master volume control, chairman priority tone,and 8-pin DIN trunk input/output for loop-through connection. The unit shall provide 24VDC±1VDC to contribution units, operate on 230VAC ,50Hz ,have frequency response of 200 Hz–12kHz,THD<1%,dimensions approximately 88×361×252 mm, weight approximately 5.5 kg with as per the direction and entire satisfaction of Fire officer.
4Providing and fixing of extension cable assembly, suitable for extending the connection between the conference control unit and delegate/chairman discussion units, consisting of a 10-metre extension cable with as per the direction and entire satisfaction of Fire officer.
5Providing and fixing of Podium High-quality unidirectional condenser gooseneck microphone with flexible stem, phantom-powered by amplifier with 12–48VDC supply and current consumption less than 8mA, sensitivity 0.7 mV @ 85dB SPL (2mV/Pa), maximum input sound level 110dB SPL, distortion<0.6%, frequency response 100Hz–16 kHz, output impedance <200Ω, equivalent input noise 28dBA SPL,ON/OFF sliding switch with priority contact, fixed 2m cable with lockable 5-pin DIN 180° connector, dimensions approximately 30 × 500 mm, weight approximately 300 g with as per the direction and entire satisfaction of Fire officer.
6Providing and fixing Handheld Wireless Mic with the following specifications Transmitter :Frequency Response-30 Hz to 16 KHz,Polar Pattern Cardioid/ Super cardioid ,Sensitivity > 5.2mV/Pa, RF Output Power-50 mW, Should have the provission of changing Microphone heads Receiver: Bandwidth-36 MHz, Carrier Frequency Range - 480 to 865 MHz, Signal to Noise Ratio > 100 dB A, Frequency Response - 55 Hz to 16 KHz as per the direction and entire satisfaction of Fire officer.
7Providing and fixing 6 W dual-cone speaker designed for high-quality speech and background music reproduction in public address systems, featuring a built-in 100 V line matching transformer with selectable power taps (6 W / 3 W / 1.5 W / 0.75 W) for flexible installation in distributed audio networks. It provides a wide frequency response of approximately 80 Hz to 18 kHz with good sensitivity (~92 dB SPL at 1 W/1 m) for clear and intelligible sound coverage in offices, retail spaces, and commercial buildings as per the direction and entire satisfaction of Fire officer.
8Providing and fixing booster power amplifier (120W) is a high-performance industrial amplifier designed for large public address and voice evacuation systems, providing 480 W RMS output with support for 70 V / 100 V constant-voltage lines and 8/4 ohm low-impedance speakers for flexible system expansion. It features dual balanced XLR inputs with priority switching, loop-through capability, and an additional 100 V line input for slave operation, ensuring seamless integration with existing PA networks. The amplifier operates on 230 V AC(±10%, 50/60 Hz) or24 V DC backup supply, with excellent audio performance including frequency response of approx. 50–18,000 Hz, low distortion (<1%), and high signal-tonoise ratio (>90 dB) as per the direction and entire satisfaction of Fire officer.
9Providing and fixing 15 W high efficiency circular horn Loudspeaker (Horn Type) with weather resistance wall mounting arrangement etc as per the direction and entire satisfaction of Fire officer.
10Supply of booster power amplifier (480 W) is a highperformance industrial amplifier designed for large public address and voice evacuation systems, providing 480 W RMS output with support for 70 V / 100 V constant-voltage lines and 8/4 ohm low-impedance speakers for flexible system expansion. It features dual balanced XLR inputs with priority switching, loop-through capability, and an additional 100 V line input for slave operation, ensuring seamless integration with existing PA networks. The amplifier operates on 230 V AC (±10%, 50/60 Hz) or 24 V DC backup supply, with excellent audio performance including frequency response of approx. 50–18,000 Hz, low distortion (<1%), and high signal-to-noise ratio (>90 dB) etc complete as per the direction and entire satisfaction of Fire officer.
11Supply of Bosch make 240 watt mixer amplifier with 4 mic/line inputs (All inputs should have phantom power facility per condenser microphone), Frequency response (line) - 60 Hz to 18 kHz (+1/-3 dB@-10dB) plus music source input, announcement only output, 3-wire volume override, 2 tone chime., Frequency response (mic) - 80 Hz to 18 kHz (+1/-3 dB@-10dB), Distortion - <1%@ rated output power, 1kHz. etc complete as per the direction and entire satisfaction of Fire officer.
12Providing and fixing 20 U Rack of MS Construction of size 18 SWG duly wired provided with front and back door, front door with acrylic sheet, back door with louvers with provision for housing the above control equipment complete with connecting strip and power points etc complete as per the direction and entire satisfaction of Fire officer. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58187787
AUTHORITY Local Bodies
TENDER VALUE 9.56 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name New Delhi Municipal Council
Work Description Tender for Repairing And Maintenance Of Pa System Of Disaster Management Center, Humayun Lane And Babu Dham Housing Complex.
Basic Detail
Tender No 15/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 23 Oct 2026
Submission Date 02 Nov 2026
Open Date 02 Nov 2026
Finance
Tender Value 9.56 Lakhs
Tender Fee Ref. Documents
EMD 19136
Exemption Not Available
Document List
b10e454f-522a-41a5-8961-e190cd004528.html
BOQ_401023.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

b10e454f-522a-41a5-8961-e190cd004528.html

xls

BOQ_401023.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender