Tender for Repair Of Plaster/Rcc Of All Heights Of Hostels, Departments & Residences In Zone B At Iit Roorkee
BOQ
| Sl. No. | Item Description |
| 1 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 2 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 4 | Weather shade, Chajjas, corbels etc., including edges |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 6 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 9 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 10 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 11 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 12 | Providing and fixing factory made Fiberglass Reinforced plastics (F.R.P.) chajja 4 mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2 mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically,including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746, duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight (Only plan area of chajjas shall be measured for making payment). |
| 13 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 14 | Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 15 | Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 16 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. |
| 17 | 0.80 mm thick with zinc coating not less than 275 gm/m² |
| 18 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 19 | In 75x75 mm deep chase |
| 20 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 21 | 75 mm diameter |
| 22 | 110 mm diameter |
| 23 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 24 | Coupler |
| 25 | 75 mm |
| 26 | 110 mm |
| 27 | Single pushfit Coupler |
| 28 | 75 mm |
| 29 | 110 mm |
| 30 | Single tee with door |
| 31 | 75x75x75 mm |
| 32 | 110x110x110 mm |
| 33 | Single tee without door |
| 34 | 75x75x75 mm |
| 35 | 110x110x110 mm |
| 36 | Bend 87.5° |
| 37 | 75 mm bend |
| 38 | 110 mm bend |
| 39 | Shoe (Plain) |
| 40 | 75 mm Shoe |
| 41 | 110 mm Shoe |
| 42 | 12 mm cement plaster of mix : |
| 43 | 1:4 (1 cement: 4 fine sand) |
| 44 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 45 | 1:4 (1 cement: 4 fine sand) |
| 46 | Neat cement punning. |
| 47 | 13.21 Extra for providing and mixing water proofing material in cement plasterwork in proportion recommended by the manufacturers. |
| 48 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 49 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 50 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 51 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 52 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 53 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface including disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. |
| 54 | For door/ window/ clerestory window |
| 55 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 56 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 57 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) |
| 58 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 59 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 60 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 61 | In cement mortar |
| 62 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead |
| 63 | 100 mm dia pipe |
| 64 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 65 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 66 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 67 | 18.76.1 With common burnt clay F.P.S. (non modular) bricks |
| 68 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 69 | Labour for cutting C.I. pipe with steel saw. |
| 70 | 80 mm diameter C.I. pipe |
| 71 | 100 mm diameter C.I. pipe |
| 72 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 73 | 50 mm average thickness |
| 74 | 25 mm average thickness |
| 75 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 76 | Bars upto 12 mm diameter |
| 77 | Bars above 12 mm diameter |
| 78 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 79 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 80 | Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the Engineer-in-charge. |
| 81 | Wooven PVC cloth |
| 82 | Water proofing treatment of RCC sunshade with Zycosil/equivalent water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred f irst & 2 litres of Zycoprime/equivalent added and stirred (total 23 litres)) till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls. |
| 83 | Providing, mixing and applying 12 mm thick ready mix cement mortar of approved make as per specifications and directions of Engineer-in-charge. |
| 84 | Providing, mixing and applying 15 mm thick ready mix cement mortar of approved make as per specifications and directions of Engineer-in-charge. |
| 85 | Providing and fixing 5mm thick toughend glass etc complete as per direction of EIC. |
| 86 | For Calculation purpose Only |
| 87 | Sub Total (A) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender