Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #58186675

Tender For Provn Of 01 X 500 Kva Distribution Transformer Along With Its Connected Accessories At Certain Unit And Provn Of 02X4 Way Ht 11 Kv Rmv For Depot Area Of Certain Unit At Army Area Banar Under Ge Banar

Issued by Statutory Bodies & Commissions/Committees · Jodhpur, Rajasthan
Tender Value
74.50 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
8 days left
EMD
1.36 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 01 X 500 Kva Distribution Transformer Along With Its Connected Accessories At Certain Unit And Provn Of 02X4 Way Ht 11 Kv Rmv For Depot Area Of Certain Unit At Army Area Banar Under Ge Banar

BOQ

Name of Work:- PROVN OF 01 x 500 KVA DISTRIBUTION TRANSFORMER ALONG WITH ITS CONNECTED ACCESSORIES AT CERTAIN UNIT AND PROVN OF 02x4 WAY HT 11 KV RMV FOR DEPOT AREA OF CERTAIN UNIT AT ARMY AREA BANAR UNDER GE BANAR
Sl. No. Item Description
1M&L for Cutting the road / hard standings and excavating in trenches not exceeding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying of cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified & directed by Engr-in-charges.
2Supply and fix straight through heat shrinkable cable joint kit including all material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm cable of 11000 Volt (Earthed) grade all as per manufacturer recommendation complete all as specified & directed by Engr-in-charges.
3Supply, installing, testing and commissioning of outdoor type plinth mounted step down transformer, 11 KV/433 Volts (at no load), AC 3 phase 50 Hz, 500 KVA capacity,Level 3, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +10% to -10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. The transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type wil low loss, non ageing, high permeability PRIME GRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. complete all as specified & directed by Engr-in-charges. (Make :- Schneider/RTS/Indian Transformer/Crompton Greaves/Volt Amp Ltd Baroda)
4Note for Item Ser NNo 1.0 :- The transformer shall be energy efficient Level III, IS 1180 (Part-I) : 2014 and shall comprise of the following :- (a) One cable box on HT side (primary side) consisting of three nos epoxy bushing with copper rods, complete with nuts and washers, with cable glands and cable clamp suitable for existing HT Cable. (b) One cable box on LT side (Secondary side) consisting of four nos epoxy bushing with copper rods, complete with nuts and washers, with cable glands suitable for existing LT Cable connection in bus bar turking (BBT). (c) Oil conservator with filter type drain valve and Prismatic oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent with equalizer pipe connect to conservator tank, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with pressure release valve cap / plug with connection plate complete, Airrelease valve plug and four nos plain solid cast steel detachable rollers.
5(f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50 x 6 mm galvanised iron earth strip for earthing of body.(h) Rating plate and terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 45 KV dielectric strength at 2.5 mm air gap between testing electrodes (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) roller wheel. (n) Other accessories as per manufacturer design. (o) PCC foundation/ platform for transformer 500 KVA as per manufacturer specification and drg having bearing power more than 1 ton including demolition of existing. NOTE : Transformer shall be supplied inclusive of initial oil filling to appropriate level of insulation oil with desired dielectric strength.
6Supply Install testing & commissioning of 11KV Extensible Outdoor duty (IP 55 enclosure) SF6 gas insulated 4-way manual operated Ring Main Unit (RMU) comprising of 2 Nos Load Break Switch and 2 Nos Outgoing 630 Amps trolly mounted Vacuum Circuit Breaker unit, with breaking capacity 21KA/3sec (Internal Arc Classification AFLR 21kA1sec with Bottom Exhaust both for tank and cable box as per IEC 62271-200),enclosed in robotically welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC60056/60694/60298. Protection CTs shall be ring core type, CT ratio at incomer: 30-60/1 Amp., Number of Short Circuit Operations at rated short circuit current of 21 kA for Breaker - 50 Nos. Vaccum Interruptor, protection relay and RMU shall be of same make for better coordination. The FPI shall be integral part of RMU. Minimum one no load break switch per RMU shall be equipped with FPI to facilitate quick detection of faulty section of line. Circuit breaker shall have a min of 2000 mechanical and 2000 electrical operations at rated current and 50 nos of operations at rated short circuit current. Disconnector and earthswitch shall have a min of 1000 (M1) mechanical operations complete all as specified & directed by Engr-in-charges. (Make :- Siemens/ABB/Schneider/Crompton Greaves/L&T)
7(A) NOTE:- Others details:- System Particulars: (i) Nominal System Voltage :11kV. (ii) Voltage variation on supply side : As per IEC. (iii) Corresponding Highest System Voltage: 12kV. (iv) Frequency : 50 Hz with ± 3 % tolerance. (v) Number of Phase : 3 Phases. (vi) Busbar material : Copper, (vii) Body earthling: Solidly earthed. (viii) Fault level (minimum) kA /Sec : 21/3). (ix) Lightning Impulse Withstand Voltage (kVp) : 75 (x) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV (xi) Rated Dynamic Withstand Current (kAp) : 52.5KA. (xii) Number of Short Circuit Operations at rated short circuit current of 21 kA for Breaker - 50 Nos. (xiii) Earth switch with its own making capacity independent of breaker with own snap action mechanism for fast closing independent of operator action (E3 Class).
8(B) Applicable Standards for this RMU scope of work - IEC 62271-200. (i) The design, manufacture and performance of the Ring Main Unitsshall comply with all currently applicable statutes, regulations and safety codes. Nothing in this specification shall be construed to relieve the bidder off his responsibilities. (ii) Ring Main Units shall conform to the latest applicable, IEC 62271-100, IEC 62271-200. (iii) All live parts, bus bars, shall preferably be enclosed in stainless steel tank as per IEC. The RMU shall be type tested for internal arc test of 21KA/1 sec AFL with Bottom Exhaust for Safety of Personnel for both Tank as well as Cable Compartment as per IEC62271-200. The outer enclosure shall have IP 55 protection for complete switchgear; however it should be Top Opening Canopy & with dedicated IP 55 Cable Compartment; Indoor RMU placed inside Outdoor Enclosure should not be acceptable. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection relay with low and high set of over current and earth fault , MODBUS communication along with RS 485 Port. (iv) Internal Arc Classification should be with Bottom exhaust only. RMUs should be manufactured, inspected and invoiced from the OEM factory (v) The SF6 gas filled 11 kV, 630 Amps, extensible type, Outdoor to be supplied against this specification shall be suitable for satisfactory continuous operation as per IEC.
9Supplying, laying, jointing and testing of XLPE insulated PVC outer seathed and (earthed) PVC inner sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminum conductors, 11 KV(E) grade and conforming to IS : 7098 and, of size 120 sqmm, 3 core, laid in trenches / ducts / encased in GI pipe / fixed to pole, complete all as specified & directed by Engr-in-charges. Note : Earth work, protection pipe and Cable Joints etc shall be measured and paid separately. Note :- Excavation, earth work ,cable protection , sand fillings shall be measured and paid separately under respective items of schedule.
10Supply, laying, testing & commissioing of 400 Sqmm 3.5 core size XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 Part I marked, suitable for LT 1100 Volt system,laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe including jointing & testing complete all as specified & directed by Engr-in-charges.Note :- Excavation, earth work ,cable protection , sand fillings shall be measured and paid separately under respective items of schedule.
11All as per Ser No 6 above but size 300 sqmm 3.5 core complete all as specified & directed by Engr-in-charges.
12Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables. complete all as specified & directed by Engr-in-charges.
13M&L for tibba sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified & directed by Engr-in-charges. Note: Only punned thickness will be measured for payment purpose
14M&L for laying jodhpur stone quarry stone slab cover 25 to 30cm in width, 60cm long and 40 to 50 mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered under ground cables complete all as specified & directed by Engr-in-charges.
15Returning, filling in, including spreading, levelling , watering and well ramming in layers not exceeding 25 cm thick of excavated earth complete all as specified & directed by Engr-in-charges.
16Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a level not exceeding 1.5 mtrs above the starting point complete all as specified & directed by Engr-in-charges.
17Supply and fix outdoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm cable of 11000 Volt (Earthed) grade all as per manufactuer recommendation complete all as specified & directed by Engr-in-charges.
18Supply and fixing/laying of GI Pipe light grade 80 mm dia with necessary accessories/ fittings bracing with pole/wall for cable protections/pole for crossing of culverts/nallah /road and complete all as specified & directed by Engr-in-charges.
19Supply and installation, testing and commissioning of LT panel factory made suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC supply system confirming to IS:8623/93, outdoor type, double door floor mounting weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 1500 Amp three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. All the covers shall be provided with suitable door locking arrangements, mounted on angle iron stand fixed at 75 cm height made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears complete all as specified & directed by Engr-in-charges. (Note: (i) The size of Feeder pillar box should not be less than 1500x1600x450mm, (ii) Drawing of LT Panel shall be submitted by Contractor before placing order and will be approved by GE. INCOMING:- ACB 1000 Amp, 4 pole 50 KA 415 Volts microprocessor based - 01 No OUTGOING :- (i) MCCB 4P 630 Amp 50 KA thermal adjustable type -01 Nos, (ii) MCCB 4P 400 Amp 36 KA thermal adjustable type -01 Nos, (iii) MCCB 4P 315 Amp 36 KA thermal adjustable type -01 Nos (iv) Digital type volt meter & Amp Meter-01 Nos (v) LED type Indicating Lamp - 3 Nos
20M&L for earthing with galvanized steel earth plate of size 60x60x6 mm thick electrode and 32x6mm GI strip length up to 7.5 mtr as earth lead, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth, GI strip of size 32X6 mm dia as earthing lead by means of bolts, nuts, washers of galvanized iron all as shown in electrical plate No.3 of MES SSR Part I connected to earth test terminal point all asa specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil,earth work,PCC pit,PCC cover,funnel with watering pipe, wire mesh, common salt, charcoal etc.all as required at site for complete earthing complete all as specified & directed by Engr-in-charges.
21M&L of GI strip of size 32x6 mm including mounting on PVC/Porcelain insulators on wall and burried in ground depth not less than 60 cm in ground complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58186675
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 74.50 Lakhs
LAST DATE 20-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 01 X 500 Kva Distribution Transformer Along With Its Connected Accessories At Certain Unit And Provn Of 02X4 Way Ht 11 Kv Rmv For Depot Area Of Certain Unit At Army Area Banar Under Ge Banar
Basic Detail
Tender No CWE (A) JODH/BNR- OF 2026-27(82627/68/E8)
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 23 Oct 2026
Submission Date 20 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 74.50 Lakhs
Tender Fee 1000
EMD 1.36 Lakhs
Exemption Available
Document List
a900cbeb-7cf0-4966-b8e7-710fbdae6d92.html
BOQ_891914.xls
TENDER68.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

a900cbeb-7cf0-4966-b8e7-710fbdae6d92.html

xls

BOQ_891914.xls

pdf

TENDER68.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender