Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58186570

Tender For special Repair/Replacement Of Lt Oh Line Of Street Light Lt Ovehead Line To Underground Cables Near Perimeter And Bde Officer Area At Misa C Under Ge(S) Tezpur.

Issued by Statutory Bodies & Commissions/Committees · Sonitpur, Assam
Tender Value
46.60 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
16 days left
EMD
93200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair/Replacement Of Lt Oh Line Of Street Light Lt Ovehead Line To Underground Cables Near Perimeter And Bde Officer Area At Misa C Under Ge(S) Tezpur.

BOQ

Name of Work:- Spl repair/replacement of LT OH line of street light LT ovehead line to underground cables near perimeter and Bde officer area at Misa C under GE(S) Tezpur.
Sl. No. Item Description
1Dismantling unserviceable ACSR conductor of any size and type from LT pole and removing the quantity from site complete all as specified and as directed.
2Dismantling and taking down existing unserviceable / GI earth continuity conductor (of any size or type) from over head electric line and removing from site complete all as specified and as directed.
3Dismantling insulators of any size /type and removing from site complete all as specified and as directed.
4Dismantling and taking down mild steel cross arms, bracings, supports, channels, angles, clamps etc from pole structure and removing from site complete all as specified and as directed.
5Taking out unserviceable stay assembly including necessary excavation and demolition of PCC foundation and removing the same from site complete all as specified and directed.
6Taking down existing unserviceable stay wire of any size from LT pole complete all as specified and as directed.
7Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and as directed.
8Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
9Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
10Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punning to 18 cm complete all as specified and as directed. (Note : Punned thickness shall be measured).
11Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and directed
12M&L 100 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint including taking down old u/s one complete all as specified and as directed.
13All as per item No.12 but 40 mm dia.complete all as specified and as directed.
14Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 400 sq. mm 3½ Core including Brass Glands complete all as specified and directed by Engr-in-Charge.
15All as per item no 14 but 300 Sqmm 3.5 Core complete all as specified and as directed.
16All as per item no 14 but 95 Sqmm 3.5 Core complete all as specified and as directed.
17All as per item no 14 but 35 Sqmm 4 Core complete all as specified and as directed.
18All as per item no 14 but 25 Sqmm 4 Core complete all as specified and as directed.
19All as per item no 14 but 16 Sqmm 4 Core complete all as specified and as directed.
20M&L for drilling hole horizontally road under ( min 75 cm) pavement hardstanding by treanchless technology using ultra sound technique and necessary machine suitable and including 150 mm dia HDPE pipe complete all as specified and as directed.
21Dismantling existing cement poles/ steel struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc complete all as specified and as directed.
22M & L for Steel tubular swaged poles complete with cast iron/MS base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31 , 9.0 meter long including making hole of 2 inch dia at 2.5 meter from bottom and 1 inch at 8 meter from bottom complete all as specified & directed.Note: PCC anti climbing device, cross arms insulator, ACSR conductor and earth work measure and paid separately)
23M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ Panels etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed.
24M & L PCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as coping of pole/panel including necessary form work as required complete all as specified and as directed.
25Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type CPRI approved, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension suitable to operate submersible pump, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :-(a) Copper Busbar rating- 400 Amps- 04 Nos(b) Indication lamp for RYB - 01 Set(c) MCCB-200 Amp, 4 pole, 25K adjustable thermal and magnetic settig, 415 V, 50 Hz AC-01 No(incoming) (d) MCCB-100 Amp, 4 pole, 25KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 01 No (e) MCCB-63 Amp, 4 pole, 10KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 02 No (01 Spare)(j) S&F digital ampere meter 3 1/2 display incl CT having CTR 200/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
26Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type CPRI approved, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension suitable to operate submersible pump, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :-(a) Copper Busbar rating- 200 Amps- 04 Nos(b) Indication lamp for RYB - 01 Set(c) MCCB-100 Amp, 4 pole, 25 K adjustable thermal and magnetic settig, 415 V, 50 Hz AC-01 No(incoming) (e) MCCB-63 Amp, 4 pole, 16 KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 02 No (j) S&F digital ampere meter 3 1/2 display incl CT having CTR 100/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
27Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting (Inside cavity to be made in Pit for placing cover slab) made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed incl demolition to existing one complete all as specified and as directed.
28Supply and fixing of loop in loop out junction box with SP 6-32 amp, IP 65 / IP 66 protection halogen free and weather proof of size (130 x 180 x 77) mm, fixed to Pole with suitable clamp including nuts and bolts and washers incl provision of connector fixed to pole complete all as specified and as directed.
29NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58186570
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.60 Lakhs
LAST DATE 12-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair/Replacement Of Lt Oh Line Of Street Light Lt Ovehead Line To Underground Cables Near Perimeter And Bde Officer Area At Misa C Under Ge(S) Tezpur.
Basic Detail
Tender No 9210
Bidding Type Tender
Location
City Sonitpur
State Assam
Key Dates
Publish Date 23 Oct 2026
Submission Date 12 Nov 2026
Open Date 14 Nov 2026
Finance
Tender Value 46.60 Lakhs
Tender Fee 500
EMD 93200
Exemption Available
Document List
8c0dd018-610b-40f1-b342-6f6faf954b89.html
Addldocus.pdf
BOQ_892188.xls
Tenderdocus.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Nov 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

8c0dd018-610b-40f1-b342-6f6faf954b89.html

pdf

Addldocus.pdf

xls

BOQ_892188.xls

pdf

Tenderdocus.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender