Tender For Repair , Maintenance And Servicing Of Dg Sets, Amf Panel, Distribution Panel, Standby Ug Cable Of Lifts And Other Connected Works At Navy Nagar, Colaba, Mumbai
Tender Value
45 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
14 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair , Maintenance And Servicing Of Dg Sets, Amf Panel, Distribution Panel, Standby Ug Cable Of Lifts And Other Connected Works At Navy Nagar, Colaba, Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | M&L for carrying out B check including periodic maintenance & servicing prescribed by the manufacturer of the DG Set from authorized rep of service engineer from the manufacturer of the DG Set of Greaves/Cummins/Kirloskar 40 to 200 KVA capacity installed at R-29 Bldg, Near Tula Bldg, R-12 Bldg, Mithun Bldg, Mulla Auditorium, R28 Pump House, Substation No. 7, R41 Bldg, Substation No. 8 & Trolley (Total 13 Nos.) including replacement of engine oil, coolant and replacement of following unserviceable spares complete all as specified and directed by EIC.Note: Spares will be measured & paid separately under respective items here in after. |
| 2 | Supply only in replacement Diesel fitter as per existing make and model. |
| 3 | Supply only in replacement Lub oil filter as per existing make and model.. |
| 4 | Supply only in replacement Air filter element as per existing make and model. |
| 5 | Supply only in replacement Fan belt as per existing make and model. |
| 6 | Supply only in replacement Carbon bush as per existing make and model. |
| 7 | Supply only in replacement high pressure oil pipe as per existing make and model. |
| 8 | Supply only in replacement Lub oil pipe as per existing make and model. |
| 9 | Supply only in replacement Radiator hose pipe set as per existing make and model. |
| 10 | Supply only in replacement LLOP Sensor as per existing make and model. |
| 11 | Supply only in replacement of coupling flanged type as per existing make and model. |
| 12 | Preventive maintenance and servicing of DG sets 40 to 100 KVA capacities installed Mithun Bldg, R28 Pump House, Substation No. 8 (Total 03 Nos.) at Navy Nagar complete all as directed. The Monthly maint shall be carried out as under:(i) Cleaning of DG set floor and area (ii) Checking levels of Fuel/Engine Oil/Coolant and top-up the level if required (iii) Checking of Batteries, flexible coupling, injectors, thermostats, monitoring functions, compression, turbo charger clearance of bearings, air and water hoses, Zinc protective pipes, coupling disc of fuel pump drive, 'V' Belts (iv) Checking tightening of all nuts and bolts. (v) Checking levels of distilled water in batteries and top-up the level if required. (vi) Checking levels of distilled water in batteries and top-up the level if required. (vii) Cleaning of air filters (viii) Lubricating/Greasing to moving parts (ix) Checking and reset valve clearances. (x) Checking and setting of speed Governor and engine shut down for proper functioning (xi) Checking of carbon bushes of generator and lubricate the bearings (xii) Cleaning of Crankcase ventilation, cooling water spaces, inter cooler (xiii) Checking of replacing carbon bushes and starter pinion |
| 13 | (xiv) Checking and monitoring of DG set running in condition by switching on mannual position on without load not less than 15 minute twice in week for each DG set and maintaining their running record in Log sheet/PRRB. If any shortcomings found in any DG set, immediately rerport to JE concern as well as to the contractor.Schedule of running for each DG set shall be decided by the Engr-in-Charge.Note : -(a) Spare parts shall be measured and paid separately. (b) Oil, Coolant and distril water will be measured and paid saparately. (c) Complaint pertains to DG Set of the sch A as given by Engr-in-Charge at any time shall be attend within 12 Hour from the time of complaint assined to the representative of the firm as directed by Engr-in-Charge up to the satisfactory level and on failing which the penalty shall be imposed 2500 per day per item / complaint of schedule \\"A\\". |
| 14 | All as per Item No. 2.00 above, but for DG sets of 100 KVA to 200 KVA capacity (Total 10 Nos.), at Navy Nagar complete all as directed. The Monthly maint shall be carried out as under: |
| 15 | M & L for replacement of old engine oil from the sump of DG Sets installed at various locations after cleaning the oil sump throughly supply & filling new Lub oil, SAE 15W40 grade complete all as specified & directed by Engineer-In-Charge. Make : Servo super of Indian Oil or Equilent grade of Hindustan Petrolium. |
| 16 | S&F in replacement of Fuel Pre Filter Suitable for Diesel Engine, TBD 3V 6MK-1/TBD 2V6/TBD 2V 6MK-1/TDL4L. Make : Greaves Ltd.and all as specified and directed by Engineer-In-Charge. Male/Botch/Greaves |
| 17 | M & L for topping up of water coolent in radiator of DG sets tinstalled at various locations complete all as specified & directed.Make : TVS Girling/volvo line or of equivelent make all as approved & directed by EIC. |
| 18 | M & L for dismantaling of FIP for ovarhaulling and caliberation in authorised workshop including replacement of wornout rings plungers, damper plate, gaskit etc and reassembling testing complete for DG sets of capacity 40 KVA to 140 KVA complete all as specified & directed. |
| 19 | All as per Item No 6.00 above but DG sets capacity 160 KVA to 200 KVA |
| 20 | M & L for repair overhalling of self starter including replacement of worn out clutch assembly bush, spring, plunger assembly, solenoid switch, corbon brushs, spring etc for DG sets of capacity 40 KVA to 140 KVA complete all as specified & directed. |
| 21 | All as per Item No 8.00 above but DG sets capacity 160 KVA to 200 KVA |
| 22 | Repair/overhaling of dynamo/charging alternator including replacement carbon, brushes holder, spring commutator/slipring assembly bearing regulator its of any make, type and capacity, complete all as directed. |
| 23 | Cleaning of the fuel tank of DG sets of of capacity 40 KVA to 140 KVA after decaning the diesel, after throughly cleaning with kerosene oil including replacement of level indicator pipe complete all as directed by EIC. |
| 24 | All as per Item No 11.00 above but DG sets capacity 160 KVA to 200 KVA |
| 25 | M & L for dismantling and removing of water pump assessmbly complete from the engine repair/overhaulling the same by replacing worn components like bearing, impeller, bushes, oil seal, water seal, gaskit etc. reassembling, refixing and testing complete for DG sets of capacity 40 KVA to 140 KVA complete all as specified & directed. |
| 26 | All as per Item No 13.00 above but DG sets capacity 160 KVA to 200 KVA |
| 27 | M & L for Automatic voltage regulator suitable for DG set of capacity 40 KVA to 140 KVA as per existing Make & model and as directed by EIC. |
| 28 | All as per Item No 15.00 above but DG sets capacity 160 KVA to 200 KVA |
| 29 | M & L for replacement of fuel shutdown valve assembly complete testing including replacement of old unsv valves of any capacity DG set, complete all as directed by EIC . |
| 30 | M & L for replacement of bendix drive pinon assembly of self starter of capacity 40 KVA to 200 KVA DG set complete all as specified & directed . |
| 31 | M & L for replacement of existing make and model fly wheel ring including heating for press fitting for engine of DG sets of capacity 40 KVA to 140 KVA complete all as specified & directed. |
| 32 | All as per Item No 19.00 above but DG sets capacity 160 KVA to 200 KVA |
| 33 | M & L for replacement of stop solonoid assembly for DG sets of capacity 40 KVA to 140 KVA complete all as specified & directed. |
| 34 | All as per Item No 21.00 above but DG sets capacity 160 KVA to 200 KVA |
| 35 | M & L for Dismantling of radiator of DG set of capacity 40 KVA to 140 KVA and transporting to work shop for servicing/cleaning after dismantling twin tanks, replacement of gasket packing, nuts, bolts, washers, descaling with appropriate chemical and elding of copper brazing of damazed fins/tubes and reassembling & refixing in same position after testing complete all as specified & directed. |
| 36 | All as per Item No 23.00 above but DG sets capacity 160 KVA to 200 KVA |
| 37 | S&F Tachometer/speedo meter incl dismantling the existing meter suitable for kirloskar and cummins Engine all as directed. |
| 38 | Supply only ammeter 0 to 300 Amp range 96 x 96 mm flush type 3 Phase 415 Volts AC with CTs Ratio 100/5 A in all Three phases with 4P selector switch to read current in all three phases including dismantling old ammeter. |
| 39 | Supply only Voltmeter 0 to 500 Volts AC including dismantling old voltmeter with 4P selector switch to read 3 Phase voltage. |
| 40 | M&L for scraping the peeled oil Paint on 40 to 200 KVA DG set including alternator,Engine and Fuel tank,sound proof cover Preparing the surfaces, cleaning the dust, dirt and applying two coats of synthetic enamel paint of approved shade and writing SM No on the DG set and all as directed by Engineer-In-charge. |
| 41 | M & L for repairing of complete GENSET engine wiring including extesion of existing PVC insulated , stranderd copper conductor wire of size 2.5 sq mm /1.5 sq mm for control/ signal circuit complete with & including flexible conduit, copper lugs, PVC ties, fasteners & synchronisation and calliberation of AMF panel with engine control panel complete all as specified & directed . |
| 42 | M & L for General servicing/repair of AMF panel including cleaning, resetting/adjustment of relays of timer relay,overload relay, auto start/stop relay its checking and replacement if required wire,diodes resistor etccomplete for existing make and capacity |
| 43 | M & L for replacement of SMPS based Electronic Battery Charger suitable for 12 / 24 Volts battery charging system complete all as specified & directed. |
| 44 | M & L for replacement of contactor 4 pole, not less than 300 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. Make- L&T, Type-MCX-41, cart part No.CS97023 or equivalent model of Legrand/Siemens. |
| 45 | M & L for replacement of contactor 4 pole, not less than 250 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. Make- L&T, Type-MCX-34, cart part No.CS97022 or equivalent model of Legrand/Siemens. |
| 46 | M & L for replacement of contactor 4 pole, not less than 200 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. Make- L&T, Type-MCX-33, cart part No.CS97021 or equivalent model of Legrand/Siemens. |
| 47 | M & L for replacement of spare coil for existing contactor fitted in AMF panel of any capacity & type complete all as specified. Make:- L&T/Legrand/Siemens. |
| 48 | M & L for replacement of engine start relay 12/24 Volts compitable with existing AMF panel complete all as specified. Make:- PIC /Technica/Indo. |
| 49 | M & L for replacement of over and under voltage relay 3 phase 415 Volts compitable with existing AMF panel complete all as specified. Make:- PIC / Minilec/ L&T. |
| 50 | M & L for replacement of Auxiliary relay 8 pin /11 pin compitable with existing AMF panel complete all as specified. Make:- PLA /L&T( Slazer)/Schneider. |
| 51 | M & L for replacement of timer switch AC/DC compitable with existing AMF panel complete all as specified. Make:- PIC/MINUTE. |
| 52 | S&F in replacement with new Exhaust silencer suitable for Diesel Engine,Model No.TBD 3V 6MK-1/Model No.TBD 2V6/ Model No.TDL4LModel No.TBD 2V 6MK-1. Make : Greaves Ltd.and all as specified and directed by Engineer-In-Charge. |
| 53 | M & L for replacement of ON Load change over switch 4 Pole, 415 Volt, in sheet steel enclosure of capacity 200 Amps complete all as specified & directed. Make-L&T/Schneider |
| 54 | Supply and fixing in replacement of Asbestos Rope DG Rating 40KVA to 200KVA and all as specified and directed. |
| 55 | M & L for replacement of battery terminals brass with steel nuts, bolts & washers and all as directed. |
| 56 | M & L for replacement of battery lead stranded copper conductor of size 50 Sq mm and all as directed. |
| 57 | M&L for filling / pouring distill water packed in 20 / 25/ 35 litre PVC containers & top up of electrolite for servicing of battery complete all as specified & directed . |
| 58 | Supply and installation of maintenance free battery lead acid type of capacity 12 Volt 180 AH for DG Sets installed at various locations Complete all as specified & directed by Engineer-in-charge.(Make Excide express/ Amron/ Microtek) |
| 59 | Taking down old existing unserviceable AMF panel of DG set and supply, install, testing and commissioning of new AMF panel for DG Set of Capacity 40 to 250 KVA 3 phase, 4 wire, 415 volts, with copper busbar strip of suitable capacity with necessary clamps, nuts, bolts and washers, floor mounted type and made with angle iron 40x40x5 mm thick, legs of size not less than 0.60 Mtr Long from floor level and painted with two coats of red oxide primer incl foundation in PCC including multi function meter with LED display with CT's, LED indicator lamp all as specified & directed.Note : All existing cable connections will be disconnected from old panel carefully and re-connected with new panel by providing glands and thimble all as directed by Engineer-in-Charge. |
| 60 | M & L for 80 mm dia M S Pipes heavy grade for fixed on ground/floors to used as post/structure for shed including fabrication work like welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 61 | Same as Item No 48.00 above but 40 mm dia M S Pipes heavy grade. |
| 62 | M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 63 | M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 64 | Supply, Fixing, testing and commissioning of XLPE insulated armoured, heavy duty electric cable with aluminium conductor laid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands, properly as directed by engineer-in-charge and taking out existing damaged unserviceable cable of following sizes:- Note : Excavation, earthwork and cable protection shall be measured and paid separately under relevant items. |
| 65 | 300 Sq mm, 3.5 core |
| 66 | 185 Sq mm, 3.5 core |
| 67 | 120 Sq mm, 3.5 core |
| 68 | 95 Sq mm, 3.5 core |
| 69 | 70 Sq mm, 3.5 core |
| 70 | 35 Sq mm, 3.5 core |
| 71 | 25 Sq mm, 3.5 core |
| 72 | 16 Sq mm, 4 core |
| 73 | Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables . |
| 74 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils. |
| 75 | Removing excavated material from the site of work to outside MD land complete all as specified. |
| 76 | Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm girth for laying of pipes/ cables complete. |
| 77 | M&L for making good of road cutting upto 450 mm wide, clean the cutting surfaces and filling hard cor and match the existing bitumen surface of road with premix bitumenus material ready to use complete all sa specified and directed by Engr-in-charge. |
| 78 | M&L for GI pipe ,light grade 50mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed. |
| 79 | M&L for GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed. |
| 80 | M&L for GI pipe, light grade 100mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 81 | M & L for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 53 complete as specified and directed. |
| 82 | M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of existing size and existing type complete as specified and directed. |
| 83 | Material and labour for layer of 50 mm thick natural river sand bed under floors or in foundation or under paver blocks including watering and consolidation complete as specified and directed. |
| 84 | M&L for High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 40mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 85 | M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 75mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 86 | M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 100/110mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 87 | Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- JEF Ecosafe or equivalent as approved by GE. |
| 88 | M&L for taking out existing Panel and shifting of LT panel of any size with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed. Please Enable Macros to View BoQ information |
| 89 | M&L for taking out existing Panel and shifting of LT panel of any size with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysNov 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender