Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #58186552

Tender For Provn Of Security Post, Drainage System, Temp Grain And Fodder Shed, Safety Grills, Addn/Altn To Bldg No P-454 Abd special Rep To Bldg No P-360 Under Age B/R Ii At Chandimandir

Issued by Statutory Bodies & Commissions/Committees · Panchkula, Haryana
Tender Value
43.76 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
15 days left
EMD
87520
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Security Post, Drainage System, Temp Grain And Fodder Shed, Safety Grills, Addn/Altn To Bldg No P-454 Abd special Rep To Bldg No P-360 Under Age B/R Ii At Chandimandir

BOQ

Name of Work:- PROVN OF SECURITY POST, DRAINAGE SYSTEM, TEMP GRAIN AND FODDER SHED, SAFETY GRILLS, ADDN/ALTN TO BLDG NO P-454 ABD SPL REP TO BLDG NO P-360 UNDER AGE B/R II AT CHANDIMANDIR
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5m in depth and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge.
2providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate, as in foundation, mass concrete etc., complete all as specified and as directed
3Cement concrete type B-2 1:2:4 (40 mm graded aggregate) in surface channel and drains complete all as specified.
4Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed (reinforcement shall be measured and paid for separately).
5Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in beams, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
6Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams etc, shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
7Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed (reinforcement shall be measured and paid for separately).
8Form Work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed.
9Form work to sides and soffits of floor or roof beams, beam hanunchings, girders, shelves including supports, overhangs etc also splays between floors and beams etc rough finished surface of concrete flat complete all as specified and directed.
10Form work to soffits of suspended slabs such as roof slabs rough finished surface of concrete flat not exc 200mm thick complete all as specified and directed.
11Form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 20cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work.
12Form work to sides of pillars, coloumns and similar items (square, rectangular or polygonal) including edges rough finished surface of concrete flat complete all as specified and directed.
13Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
14Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, as in stirrups, binder etc including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified & directed.
15Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
16Rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:6 surface finished even and smooth without using extra cement compelte all as specified and directed.
17Rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:4 surface finished even and smooth without using extra cement incl scaffolding & necessary safety equipments required at site, compelte all as specified and directed.
1810mm thick rendering on cocnrete surface of ceiling with CM 1:3 finished even and smooth without using extra cement complete all as specified and directed.
19Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
20Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer(through mechanical means), complete all as specified & directed.
21Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed.
22Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed.
23Supply of soil and filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
24Hard core of gauge of broken stone or boulders, not exc 63mm , deposited spread and levelled in layers n.exc 15 cm thick, watered & rammed to a true surface ,complete all as specified.
2575mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
2630mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in floor even and rough to receive the top finishes complete all as specified and directed.
27Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
28Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge, including making good dismantled portion with PCC (1:2:4) type B-1 in CM 1:3 complete all as specified and directed.
29Sheet glass 4mm thick, ordinary quality and glazing with oil putty in square, area not exc 0.5 sq. mtr in each pane,complete all as specified and directed.
30Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with stainless steel wire staples/ aluminum beading, complete all as specified & directed.
31150mm long alumimium handles, cast type anodized complete all as specified and directed.
32Aluminum alloy, anodized, sliding door bolt 300mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed.
33Supply and fixing factory made steel windows (Box type) primer coated with glazing bar and openable shutter prepared to receive sheet glass complete including cutting holes, (four Nos for each window) and making good dismantled portion in PCC (1:2:4) type B1 including following fittings welded to frame/ shutter complete all as specified.(a) Hold fast 150mm made out of 25 x 6 mm flat iron bend to shape, 04 Nos each window (02 Nos on each side).(b) Handle of Z section 20mm x 25mm, 100 mm long -01 No each leaf. (c) MS tower bolt 150mm long, 02 Nos each leaf.(d) Z section 20mm x 25mm, 100 mm long stopper -01 No each leaf.(e) Cleat 55 mm long of hollow square section of 15mm x 15mm of 24 gauge thickness, welded to hinge of 55mm size, 01 No each leaf.(f) MS box type hinges of 75 mm size, 02 Nos per leaf.(g) Fabrication and fixing complete. Note: (i) Glass panes, MS wire cloth & painting shall be measured and paid for separately. (ii) MS flat iron fixing of wire cloth and window shutters shall be included in item rate.
34All As per serial item No 33 here in before but without glazing bar.
35Steel water tubes, 15mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, complete all as specified and directed.
36Steel water tubes, 20mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, complete all as specified and directed.
3775mm thick Cement concrete type C2, (1:3:6) (using 40mm graded aggregate) as in Plinth protection finished the concrete surface even and smooth without using extra cement, 10mm construction joint will be provided and Panel should not be more than 3 m in length and joint filled with filler bitumen and sand in ratio (1:3) complete all as specified and directed.
38Cement concrete 1:2:4 Type B 1 (using 20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 4028, water trought and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
39PCC (1:3:6) type B-1 using 20 mm graded stone aggregate as in bed blocks, coping etc; including necessary formwork 1.5m clearspan, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directedcomplete all as specified and directed.
40Supply only integral water proofing compound (ISI Marked) complete all as specified & directed.
41200 mm size aluminium , barrel tower bolt of extruded section and complete all as specified and directed.
42Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.
43Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 t complete all as specified & directed.
44Vitrified creamic coloured tiles 8-10mm thick (square / rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
45All as per item No 44 here in before but in skirting including necessary cutting over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
46Sheet glass 5.5mm thick, ordinary quality and glazing with oil putty in square/rectangular , area not exc 0.5 sq. mtr in each pane,complete all as specified and directed.
47Sheet glass 5.5mm thick, ordinary quality and glazing with oil putty in square/rectangular , area exc 0.5 sq. mtr in each pane,complete all as specified and directed.
48Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe 165-0, all as specified and directed.
49Pressed steel frames 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, including filling of PCC 1:3:6 in hollow frame complete all as specified and directed.
50Flush door shutters 35mm thick factory made solid core construction with block board core and ply wood face panels commercials type on both side complete all as specified & directed.
51Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
52Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (150mm size), complete all as specified and directed.
53Machine cut Kota Stone Slab 20-25mm thick over cement screed bed laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including rubbing and ploshing complete over and including 15mm thick screed bed in CM 1:6 all as specified and directed.
54All as per serial item No 53 hereinbefore but on skirting / vertical surfaces laid over and including 10mm screed layer in cement mortar 1:4, cutting, rubbing, grinding and polishing complete, all as specified.
55Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
56Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
57Gl frame work for seamless ceiling (Size of grid 605 x 605mm )comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and directed
584mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping, fixed as in repair complete all as specified.
59Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish outside MoD landall as specified & directed by Engineer-in-charge.
60PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) 40mm thick avg thickness as roof padding using water proofing compound complete all as specified and directed.Note: WPC shall be measured and paid separately
61Taking up or down PVC/GI pipe and connections 15mm bore with connections, fittings incl cleaning of tubes and refixing as directed ,complete all as specified and directed.
62Taking up or down PVC/GI pipe and connections 20mm bore with connections, fittings incl cleaning of tubes and refixing as directed ,complete all as specified and directed.
6320mm bore dia gun metal, globe or gate valve, with iron wheel head , screwed both ends for iron pipe fixed in repair complete all as specified.
6415mm bore dia gun metal, globe or gate valve, with iron wheel head , screwed both ends for iron pipe fixed in repair complete all as specified.
65500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, white in colour, screwable lid, hoisted and fixed in position, including PTMT ball valve 20mm bore & PTMT tank nipple, etc, incl dismantling of existing tank, complete all as specified and directed.
66Demolition of brickwork built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed
675mm thick rendering on cocnrete surface of ceiling/chajja, facia with CM 1:3 finished even and smooth without using extra cement complete all as specified and directed.
68Preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer(through mechanical means), complete all as specified & directed.
69Applying wall care putty 1mm thick, on new plastered wall/ceiling surfaces & smoothening the surfaces with sand papers etc., (preparatory to OBD/ plastic emulsion/ interior/ exterior emulsion paint as directed) complete all as specified and directed.
70Applying 2 coats of modified acrylic exterior emulsion paint over a coat of primer on new prepared surface having excellent scrub and peel resistance, superior whiteness, excellent finish, resistance to fading of colours, advanced anti fungal and algal protection against all round weather and paint performance of Min. 5 Years so as to obtain an acceptable finish all as per manufacturer's instruction and directed by Engineer-in-Charge.
71Applying 1coat of modified acrylic exterior emulsion paint over old prepared surface having excellent scrub and peel resistance, superior whiteness, excellent finish, resistance to fading of colours, advanced anti fungal and algal protection against all round weather and paint performance of Min. 5 Years so as to obtain an acceptable finish all as per manufacturer's instruction and directed by Engineer-in-Charge.
72Taking down chowkhats or frame n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed.
73Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame, complete all as specified and directed.
74Taking down shutter of any description not exc 1 Sqm including easing and adjusting shutters and refixing in the same opening complete all as specified and directed.
75Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, including filling of PCC 1:3:6 in hollow frame complete all as specified and directed.
7635 mm thick 2nd class factory made head wood panelled door shutter (two panel) made with lock rail and panel of 9 mm thick BWP commercial ply or 12 veneered particle board with commercial veneering on both faces, size of rail and style as per IS 1003 (Part I) kiln seasoned and chemically treated, complete all as directed.
77S&F 2nd class head wood glazed and skeleton shutters, 35mm thick, open rebated & prepared to receive wire gauge (with sash bars) edges of farming plain chamfered or rounded, fitted with cut and mitread beads for securing glass etc, sizes of membres of shutters as specified in SSR Pt-1, section 8, clause 8.24- (a), supplied and fitted to chowkats, complete all as directed.
78150mm long stailnless steel handles, ISI marked complete all as specified and directed.
79150mm long stailnless steel tower bolt, ISI marked complete all as specified and directed.
80Stainless steel sliding door bolt (ISI Marked) 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified and directed.
81Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.40mm including fixed with stainless steel wire staples/ aluminum beading, complete all as specified & directed.
82Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove scale, dirt dust etc complete all as specified & directed.
83Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed
84Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
85Demolition of stone slabs and tiles of any description or thickness in floors laid, bedded and pointed in any mortar including disposal of demolished material complete all as specified and directed.
86Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete, all as specified and directed.
8710mm thick plastering on roof surface in CM 1:4 mixed with WPC and Applying oil bound bitumen primer @ 1.50 kg/sqm and providing 3 mm thick APP modified water proofing membrane weighing 3.0 kg/sqm reinforced with non woven polyester weighing not less than 150 gm/sqm having softening point not less than 140 centigrade, having tensile strength of 650N/sqm and 350 N/sqm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180 N applied by torch application with minimum 10cm side overlap and 15cm end lap, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 kg /sqm top of membrane surface shall then be finished with solar reflective bituminous aluminium paint @ 0.10 kg/sqm, incl removal of existing bituminous felt, complete all as specified and directed. NOTE : WPC shall be measured and paid separately
88Two coats of synthetic enamel paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed.
89Two coats of synthetic enamel paint on steel and iron surfaces on surfaces over 10 cm width or girth including preparation of old surfaces complete all as specified & directed.
90PVC (SWR) pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to wall with PVC clamp of suitable size, fixed in repair complete all as specified and directed.
91110 mm bore PVC (SWR) bends of any radius, fixed as in repair complete all as specified and directed.
92Dismantling wrought iron or mild steel work of any description not otherwise provided for, all as directed.
93Refixing only of mild steel frame work of any description not otherwise described for, complete all as specified and directed.
94Complete removal of existing treatment and applying two coats of oil emulsion distemper over a coat of chalk whiting incl necessary scaffolding, complete all as specified and directed.
95Preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash at any height, complete all as specified and directed.
96Complete removal of existing treatment by scrapping of walls, chajjas, ceilings, fins, facias etc. using mechanical means like mechanical sander etc. with internal dust extraction system including expose sound substrata for further surface preparation prior to painting work, complete all as directed by Engineer-in-Charge
97Applying with 1 or 2 coats of acrylic waterproof primer coating which is formulated with acrylic polymers having crack bridging ability of upto 1mm, tensile strength of 1.8 Mpa, 100% elongation and can withstand upto 5 bars hydrostatic pressure to provide better mechanical strength and adhesion to the surface all as per manufacturer's instruction. Priming work to be carried out post all repair and preparatory works including cleaning the surface from loose particles, dust and other foreign materials using water by pressure washer, complete all as directed by Engineer-in-Charge.
98Applying 2 coats of modified acrylic exterior emulsion paint over old prepared surface having excellent scrub and peel resistance, superior whiteness, excellent finish, resistance to fading of colours, advanced anti fungal and algal protection against all round weather and paint performance of Min. 5 Years so as to obtain an acceptable finish all as per manufacturer's instruction and directed by Engineer-in-Charge.
99Hacking out old broken glasses of any description from metal frames including punching or drilling out old glazing pins/springs clips and providing and fixing, complete all as specified and directed.
1001.6 mm thick mild steel, plain black sheet in wall cladding, steel glass and similar work, cut to size, holes punched, incl round headed screws and fixed to steel framing with plain 40 mm lap joints with riveted or welded, complete all as directed by Engineer-in-Charge
101Roof treatment complete in following stages as under and will be certified by a company technical rep whether the stages completed are as per manufacturer’s instruction and finally passed by Engr-in-Charge/GE:-
102Surface Preparation:Surface preparation over the existing terrace/roof slab to obtain a smooth , sound, dense surface incl meachanical cleaning of the existing surface by the wire brushes and water washing to remove all the loose mortar, laitance, dust, oil, grease, algae and other deleterious material opening and repairing minor cracks and surface defects using polymer modified cement mortar.
103Bore Packing:All the borehole gaps between concrete surface and PVC pipes of various dia upto the neck level shall be filled with non -shrink free flow grout . Before the bore packing , surface of the PVC pipe and concrete surface shall be made rough and sand will be sprinkled with the polymer bonding agent. Cleaning of mother concrete surface to remove debris, dust and loosely adhering particles completely. Treating all cracks, construction joints and walls/slab joints by cutting V-groove of size 25 x 25 mm and filling with repair mortar.
104Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Birla Opus Prime c2k+. After base preparation of cleaning, brushing and removal of flaky materials, grouting the porous area with cementitious grout, fixing of weep holes, grouting of pipe outlets etc. The waterproofing system shall confirm to meet minimum requirements of having upto 200% elongation as per ASTM D 7234, and crack bridging upto 2 mm as per EN 1062-7:2004. The coating shall be applied at a coverage of 5.5-6.5 sqft/Kg for 2 coats.
105Providing and laying 200 GSM non woven geo textile membrane as separation layer between water proofing coat and screed bed , incl overlaps (minimum 100 mm), surface preparation and all leads & lifts complete as per specifications.
106NOTES:-(i) Authorised applicator of the company with trained/ skilled workers will only be allowed to execute the work and the applicator will submit the authorization and experience certificate from the company(ii) The entire quantity of material will be calculated and brought on site as decided by Engr-in-Charge and will be accepted only post verification of PVs and Challan from the company through Mail.(iii) Material will be kept in the custody of MES rep and will be issued to the authorised applicator as per requirement.(iv) Each stage will be properly executed with the supervision of company rep and Stage passing register will be properly maintained accordingly.(v) The contractor shall submit manufacturer generated 10 years warranty card during submission of RAR and Final Bill.(vi) A guaranty amount @ 10% will be kept as reserve till completion of warranty period and will be released thereafter.(vii) Any deterioration during the warranty period will be rectified by the manufacturer without any financial effect.(ix) Ponding test shall be carried out for 72 Hrs after completion of roof treatment and ponding shall be done by applicator with company technical rep as per manufacturer's instruction and finally passed/ directed by Engr-in-Charge/GE
107Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account.
108All as per serial item 102 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed
109All as per serial item 102 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
110All as per serial item 102 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
111Switch modular type (ISI marked), single pole, one way 6 Amps two way, one module (ISI marked), complete all as specified & directed.
112Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed.
113Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed.
114Socket shutters outlet 2 in 1, 3/5 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
115Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed.
116Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
117Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed.
118LED lamp 9 watts, B-22 type complete all as specified .
119MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed.
120MCB, SPN , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
121MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
122LED lights inverter batten fitting 1x 20W, 220V,AC, 6500K, with aluminium housing and diffuser with elegantly designed end caps including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
123LED inverter batten light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed.
124LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,including lamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
125Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note for serial item No 108 & 109 : (i) For the purpose of measurement, 2 single core of 10 sqmm and one single core earth cable of 10 sqmm cable shall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth
126Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose to fan complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58186552
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.76 Lakhs
LAST DATE 13-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Security Post, Drainage System, Temp Grain And Fodder Shed, Safety Grills, Addn/Altn To Bldg No P-454 Abd special Rep To Bldg No P-360 Under Age B/R Ii At Chandimandir
Basic Detail
Tender No GE/CHM-79/2026-2027
Bidding Type Tender
Location
City Panchkula
State Haryana
Key Dates
Publish Date 23 Oct 2026
Submission Date 13 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 43.76 Lakhs
Tender Fee 500
EMD 87520
Exemption Available
Document List
0a349545-d5c5-47f6-8a66-655059e68d55.html
BOQ_892165.xls
Tendernotice_1.pdf
Tenderpages79.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

0a349545-d5c5-47f6-8a66-655059e68d55.html

xls

BOQ_892165.xls

pdf

Tendernotice_1.pdf

pdf

Tenderpages79.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender