Tender For Special Repair To Bldg No P 460 At Chandimandir Mil Stn
Tender Value
47.51 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
15 days left
EMD
95020
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No P 460 At Chandimandir Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Glazed ceramic coloured tiles in vertical surface of size 350 x 250x 7mm /450mm x 350mm x7mm thick set and jointed in neat cement slurry over 10 mm thick rendering in CM 1:4 for receiving the tiles including dismantling old tiles and removal of debries complete all as specified. |
| 2 | Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:4, inlcuding dismantling complete all as specified and directed. |
| 3 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 sqm but n.exc 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 4 | Coloured vitrified ceramic tiles, light shade, 8-10mm thick (square / rectangular) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed. |
| 5 | All as per item No 04 here in before but in skirting including necessary cutting over and including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 6 | Demolition of cement concrete (unreinforced) of any description and in any position (below or above GL at any ht) not otherwise specifically provide complete all as specified and directed. |
| 7 | Plain cement mortar 1:3:6 (type C-2 using 40mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement, all as specified. |
| 8 | Demolition of brick work built in cement mortar including all quoins, arches, pillar etc complete all as specified and directed. |
| 9 | Brick work with sub class ‘B’ bricks, old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4, complete all as specified & directed. |
| 10 | Brick work with sub class ‘B’ bricks , straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. |
| 11 | Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed. |
| 12 | 15mm thick rendering cement plaster in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement at any height including necessary scaffolding, safety precaution and other arragement required at site complete all as specified and directed |
| 13 | Rendering 15mm thick plaster in cement mortar 1:4 on brick or concrete surface of wall, finished even and fair without using extra cement at any height includng necessary scaffolding, safety precaution and other arragement complete all as specified and directed. |
| 14 | 10mm thick rendering in Cement and Sand mortar 1:3 on ceiling, chajja surfaces (concrete surfaces) finished even and smooth without using extra cement, complete all as specified and directed. |
| 15 | Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper white or tinted over a coat of primer on the surfaces, complete all as specified and directed. |
| 16 | Applying Two or more coats on new plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 17 | Three coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and directed |
| 18 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness and at any height complete all as specified & directed. |
| 19 | Powder coated GI Frame work grid Size of grid 605 x 605mm for ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and directed |
| 20 | 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified. |
| 21 | 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed. |
| 22 | Solid PVC wall lining consisting of 5 mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and complete all as specified and directed. |
| 23 | Taking down chowkhats or frame n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed. |
| 24 | Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed. |
| 25 | Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each, and removal from site complete all as specified & directed. |
| 26 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 27 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in- Charge |
| 28 | Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, including filling of, hollow frame with PCC 1:3:6 type C1 in frame complete all as specified and directed. |
| 29 | 35mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides all as specified & directed by Engineer-in-charge. |
| 30 | 150 mm size aluminium, barrel tower bolt of extruded section complete all as specified and directed. |
| 31 | Aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified and directed. |
| 32 | Butt hinges 100mm long, of extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 , all as directed. |
| 33 | 150mm long aluminum handle cast type anodized, complete all as specified and directed. |
| 34 | 100mm size aluminium handle (ISI Marked), cast type, anodised, complete all as specified & directed by Engineer-in-charge. |
| 35 | Powder coated powder coated aluminium sections as in frames/ shutter of doors/ windows/ventilators including necessary joining cleats, glazing clips, rubber neoprene beadings, handles, hinges screws etc. complete all as specified and directed by engineer-in-charge.Note: - (i) Thickness of powder coatings shall be not less than 30 micron.(ii) Weight of the aluminium sections only shall be measured and paid.(iii) Aluminium doors window/ ventilators to be fixed to jambs with cadmium plate screws.(iv) The rate shall be inclusive of neoprene beadings, handles, hinges, screws etc. weight of fittings/fixtures will be not be measured for arriving the weight of aluminium section.(v) Glass panes and panels shall be measured and paid separately under respective items. Design shall be approved from Engineer-in-charge as existing at site before fabrication and bulk order to the manufacturer. |
| 36 | 3mm thick exterior aluminium composite panel sheet (ACP), incl necessary scaffolding arragement upto 12 mtr hight, colour as approved by Engr In Charge, fixed as in repair all as specified and directed. |
| 37 | 4.80mm thick ordinary quality tinted glass, fixed to aluminum frame work in panes n.exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 38 | 3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty ( or beading ) in square n.exc 0.5 Sqm in each panes, including hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 39 | 3mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Square Metre in each pane, complete all as specified and directed. |
| 40 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with stainless steel wire staples, fixed in repair, complete all as specified & directed. |
| 41 | Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples , complete all as specified and directed. |
| 42 | 150mm mild steel ordinary rat tail rod pattern spring including roller and roller plate, fixed as in repair complete all as specified and directed. |
| 43 | Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 44 | Two coats of synthetic enamel paint on steel and iron surfaces over 10 cm width or girth over a coat of red oxide including preparation of new surfaces complete all as specified & directed. |
| 45 | Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), fixed as in repair complete all as specified and directed. |
| 46 | 15mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe, fixed as in repair, complete all as specified and directed. |
| 47 | 15mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, Taking up down steel tubing and connections 15mm bore complete all as specified and directed. |
| 48 | 20mm dia bore, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors, Taking up down steel tuibing and connections 15mm bore complete all as specified and directed. |
| 49 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of inserting sheets, landings, steps, cills, sunshades, shelves, lintels, etc,; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and as directed. |
| 50 | Vitreous china, wash down water closet pan, white, Pedestal pattern WC with ‘P’ or ‘S’ trap, with all fittings and connection, fixed as in repair complete all as specified and directed. Note : Size and Shape as approved by GE /Engineer-in-Charge |
| 51 | PVC valve less syphonic action flushing type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including 32mm dia PVC bend for squat pedastal pattern , fixed as in repair complete all as specified & directed. |
| 52 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, fixed as in repair complete all as specified and directed. |
| 53 | Supply and fixing in repairs Vitreous china counter top oval type wash hand basin white, of size 550 x 400 mm including pillar taps 15mm bore cast copper alloy with capstan heads, chromium plated fancy type, 32mm dia brass chromium plated waste fitting and PVC connection pipe of 15mm x 600mm long a pair of angle iron brackets duly painted/Erecting stand including cutting and pinning in ends, making good disturbed surface in cement mortar 1:3, complete all as specified and as directed. |
| 54 | Bevelled edged looking mirror of size 600mmx450mm of selected quality, glass 6mm thick, mounted on 6mm thick comercial plywood and fixed to wooden plugs with choumium plated brass screws and cup washer complete, all as specified and directed. |
| 55 | Window blinds with fixing brackets, stops, end rollers etc. including taking down old curtain rods defective bracket all as specified and as directed. |
| 56 | Towel rail 600mm long of Chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190gms), fixed as in repair complete all as specified and directed. |
| 57 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long, complete all as specified and directed. |
| 58 | Sink with drainage board made out of stainless steel sheet 1.0mm thick with plug, washers and wastes, overall size 915 x 460mm, bowl size 410x330x160mm incl fixing cantilever brackets and connection to union, pipe, fixed as in repair complete all as specified and directed. |
| 59 | 15mm bore angle valves, cast copper alloy, fancy type chromium plated, screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions, fixed as in repair all as specified and directed. |
| 60 | Stop valves , cast copper alloy screwed pressure, with crutch or butterfly handle, screwed both ends for iron pipes for unions and fixed 15mm bore, fixed as in repair complete all as specified and directed. |
| 61 | Bib taps, cast copper alloy, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair all as specification and as directed. |
| 62 | Framed work such as grills, gratings, framed guard bars, walk ways, raillings, etc usingsteel confirming to Fe-290, E-165 fixed as in repair complete all as specified and directed. |
| 63 | PVC (SWR) pipe, 110mm bore, single socketed in any length with rubber ring joints of pressure rating 6 kgf/cm2 fixed to wall/floor including taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, fixed as in repair complete all specified and directed. |
| 64 | 110mm bore PVC (SWR) bends any radius, fixed as in repair complete all as specified and directed |
| 65 | PVC (SWR) pipe, 75mm bore, single socketed in any length with rubber ring joints of pressure rating 6 kgf/cm2 fixed to wall/floor including taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, fixed as in repair complete all specified and directed. |
| 66 | 75mm bore PVC (SWR) bends any radius, fixed as in repair complete all as specified and directed |
| 67 | PVC (SWR) floor traps 75mm dia with grating including jointing to waste pipe with run led jointed and setting/fixed in cement concrete type B-1 (1:2:4), fixed as in repair complete all as specified and directed. |
| 68 | PVC (SWR) multi floor traps 75mm dia with grating including jointing to waste pipe with run led jointed and setting/fixed in cement concrete type B-1 (1:2:4), fixed as in repair complete all as specified and directed. |
| 69 | Preparation of old decorated wall surfaces and applying one coat of oil bound distemper complete all as specified and directed. |
| 70 | Complete removal of existing treatment and applying over one coat of primer over 1.00mm thick wall care putty as preparatory to distemper on surfaces of wall complete all as specified and directed. |
| 71 | Preparation of old surfaces of ceiling and applying one coat of oil bound distemper, complete all as specified and directed |
| 72 | Applying Two or more coats on old plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 73 | Preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 74 | One coats of synthetic enamel paint on old steel and iron surfaces over 10 cm width or girth including preparation of old surfaces complete all as specified & directed. |
| 75 | Preparation of old plastered or un-plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. |
| 76 | Demolition of stone slabs of any description in floors laid, bedded and pointed in any mortar complete all as specified and directed |
| 77 | 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite 15mm thick screed in cement mortar 1:6 complete all as specified and directed. |
| 78 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 79 | 500 litres capacity rotational moulded polyethylene water storage tanks 500 ltrs capacity (Cylindrical vertical with closed top) triple layered hoisted and fixed in position, fixed as in repair, completed all as specified in SSR Part-1 complete allas specified and directed. |
| 80 | Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule of 15mm dia complete all as specified & directed. |
| 81 | Cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes etc complete all as specified and directed. |
| 82 | 15mm dia PVC connection with PTMT nut, of length 450mm, fixed as in repair complete all as specified and directed. |
| 83 | Dismantling of plain or corrugate steel sheeting any gauge, thickness , including Naintal or similar patter roof coverings complete all as specified and directed. |
| 84 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed complete all as specified and directed. |
| 85 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed complete all as specified and directed. |
| 86 | Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed |
| 87 | rolled sections as in main and cross beams, columns, hip and jack rafters; purlins where connected to common rafters of angle, pipe sections etc conforming to FE 415, E-210, fixed as in repair complete all as specified and directed. |
| 88 | Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar complete all as specified & directed. |
| 89 | Demolition of mud phuska as in roof of any thickness incl plastering and leeping etc (whether full thickness removed or only a part thereof) complete all as specified & directed. |
| 90 | PCC 1:2:4 type B-1 (using 0mm graded crushed stone aggregate) as in roof padding, complete all as specified and directed. |
| 91 | 40mm thick brick tiles on roof over and including 20mm thick cement mortar 1:4 and joints grouted and pointed complete mixed with crude oil @ 5% by weight of cement complete all as specified and directed. |
| 92 | Taking down, chipping and removing the loose, split, damaged cement concrete, cement mortar surfaces of RCC columns, beams, walls, chajjas etc and exposing the reinforcement, wire brushing and cleaning the exposed steel reinforced bar, apply rust remover over the cleaned re-barsurface wash the re-bar with clean water for removing all rusts fromthe old re-barsurfaces, fixing new reonforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified cement and quartz sand mortar in CM 1:3 mix, 40mm average thick in two coats, with and including polymer @10% by weight of cement, including erecting and dismantling steel scafoldingfor carrying out the work upto height of 12 metre (Appx) complete all as specified and as directed.Note:- Make;- Dr fixit/ Sunanda/chemestik/fosrock. |
| 93 | Factory made machine pressed, coloured chequered cement concrete tiles 200mm x 200mm x 22-25mm thick (with grey cement and no pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20mm thick screed bed in cement mortar 1:6, over cement concrete 1:4:8, type D2 (40mm graded stone aggregate) for 75 mm thick floor as in sub base for tiles complete all as specified and directed. |
| 94 | Treating soil along the external wall below concrete or masonry apron using chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on S1 Page No 2 of IS 6313 (Part 2) : 2013)) @ 2025 liters per linear meter including drilling and plugging holes etc. in apron, complete all as specified and directed. |
| 95 | Treating of soil under existing floors using chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on S1 Page No 2 of IS 6313 (Part 2) : 2013)) @ one liter per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, as per manufaturer instruction complete all as specified and directed. |
| 96 | Treating the soil under plinth protection at the rate of 5 liters of chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on S1 Page No 2 of IS 6313 (Part 2): 2013)) per square meter of surface area, as per manufaturer instruction complete all as specified and directed. |
| 97 | Treating at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on S1 Page No 2 of IS 6313 (Part 2): 2013)) @ 0.5 liter / hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm center to center and sealing the same, as per manufaturer instruction complete all as specified and directed. |
| 98 | Vitreous chins urinal, Half stall urinal, fixed against wall in cement mortar (1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including spreader, CP waste coupling 32mm PVC waste pipe, fixed in repairs, complete all as specified and directed. |
| 99 | Steel lockers with locking arrangements Godrej pattern (24 Nos in 03 sets) overall size 96” x 48” in one locker total 03 lockers with cam lock system. All body powder coated Gauge 20/22, weight 95 to 105 Kgs Approx for single locker for tools of Industrial persons each locker of size 2’ x 2’ and depth 2’ complete all as specified and directed. |
| 100 | Factory made 18mm thick solid WPC (Wood Polymer Composite) board of density 650 Kg /cum with any colour and as in cupboard/ kitchen cabinet shutter/ draweretc fixed with screws, solvent / adhesive, complete all as specified and directed. |
| 101 | Continuous (piano) hinges, mild steel bright finish, width of flap when open 40mm, fixed as in repair complete all as specified and directed. |
| 102 | Magnetic shutter catcher for kitchen cabinet/cup boards complete all as specified and directed. |
| 103 | Demolition of cement concrete (reinforced) as in roofs, floors, beams, staircase, landing, chajjas, facia and similar suspended work, complete all as specified and directed. |
| 104 | Mild steel TMT bars 10mm dia and over ,cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed. |
| 105 | Mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips as in stirrups complete all as specified & directed. |
| 106 | Reinforced cement concrete 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in lintel, beams, slabs complete all as specified and directed by engineer-in-charge |
| 107 | Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exc 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 108 | Form work to edges of concrete, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work exc 10cm but n.exc 20cm wide complete all as specified and directed. |
| 109 | 3mm thick Atactic polypropylene polymer (APP) modified prefabricated five layer water proofing membrane, based polymeric membrane minimum weighing 3.6kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions , complete all as specified & directed. |
| 110 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 111 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 112 | All as per serial item 111 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 113 | All as per serial item 111 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 114 | All as per serial item 111 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 115 | Switch modular type (ISI marked), single pole, one way 6 Amps one way, one module (ISI marked), complete all as specified & directed. |
| 116 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed. |
| 117 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge. |
| 118 | Modular switch bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed. |
| 119 | Modular switch type stepped fan regulator, single pole, 230 volt one module complete all as specified and directed. |
| 120 | Electric Bell, ding dong, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge. |
| 121 | Sockets outlet multipurpose 2 in 1 pin, 6 Amps flush type ISI marked all as specified and directed by Engineer-in-charge |
| 122 | Sockets outlet multipurpose 2 in 1 pin, 6 and 16 Amps flush type ISI marked all as specified and directed by Engineer-in-charge |
| 123 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 124 | Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed . |
| 125 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 126 | MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed |
| 127 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . |
| 128 | MCB, SPN, 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 129 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 130 | LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, fixed as in repair complete all as specified and directed. |
| 131 | LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete fixed as in repair complete all as specified and directed. |
| 132 | LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed. |
| 133 | Disconnecting the power supply and taking down carefully copper aluminium sub main wiring including PVC conduit pipe of any size and any type all as specified. |
| 134 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core, fixed as in repair complete all as specified and directed. |
| 135 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC conduit 25mm size(minimum size), cutting chases in walls for PVC conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. |
| 136 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC conduit 25mm size(minimum size), cutting chases in walls for PVC conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. NOTE FOR SERIAL ITEM NO 135 & 136(i) Two runs of cable, one run of earth wire shall be considered as one running metre(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 137 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with lift hook made out of 8mm dia bar including dismantling of old eathing set complete all as specified & directed. |
| 138 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,including lamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including taking down old street lght complete all as specified and directed. |
| 139 | Ceiling fan 1200 mm sweep, Energy Saving models, pearl white / white in colour 350 RPM, 220 volt 50 Hz complete with canopy, down rod. Fan hook box type for hanging with complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, fixed as in repair complete all as specified and directed by Enginee-in-Charge. |
| 140 | Exhaust fan 450mm sweep, operating voltage at 220-240 V with all mounting accessories. Cutting hole for air ducting of exhaust fan in circle / square shape or as per site requirement into or through concrete/brick walls built in cement mortar of superficial area suitable for 450 mm exhaust fan including making good of disturbed area in cement mortar 1:3 and cement concrete 1:2:4 type B-I and cover hole as require, fixed as in repair complete all as specified and directed. |
| 141 | Air circulator wall mounted fan 600mm sweep, three blades, alloy steel body operatng, 220-240 volt quick start torque motor with copper widing with all mounting accessoreis incl taking out old fan of any size, complete all as specified and directed. |
| 142 | Fabrication, install, testing and commission of wall mounted sheet metal busbar chamber CPRI approved, grouted with nut and bolts (with proper locking arrangement and holes to distribute circuits) of size 900x800x500mm with copper strip 50mm x 10mm (04 Nos) of length 650mm with approved colour coded and PVC adhesive coated, IP-54 as per IS-13947 protection fixed on insulator with the help of nut/bolts including provison of 10 Nos 08 mm dia hole with 8 mm dia 50 mm long nut/bolts with 02 Nos of washer connected with 10 sqmm single core colour coding stranded copper cable with thimble/lugs including one MCCB, 300 Amps, four pole 3 phase 36 KA, 415 volt with adjustable thermal and megnetic release complete having adjustable type base frame and equal space around MCCB as incommer one No, making good distrubed surfaces to match with original all as specifed and directed |
| 143 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with 32 Amp MCB 'C' single pole 240 volt complete all as specified and directed. |
| 144 | Taking down carefully old unserviceable ceiling fans/wall fan /exhaust fans complete, removing its blade and deposit to the MES store yard for further action. |
| 145 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 146 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. |
| 147 | Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 148 | Dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed. |
| 149 | Brick tiles; common burnt clay building bricks sub-class ‘B’ Designation 75 laid in trenches as cable cover complete all as specified and directed. |
| 150 | LED pannel Recess mounted ultra slim 2'x2' - 36 watts edge lit tile in aluminum extruded housing with opal diffuser suitable for perfect lighting complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysNov 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender