Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #58185555

Tender For Repair / Maintenance Of Central/ Package Ac Plants Under Ge (Nw) Vasco

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
95 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
23 days left
EMD
1.67 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repair / Maintenance Of Central/ Package Ac Plants Under Ge (Nw) Vasco

BOQ

Name of Work:- REPAIR / MAINT OF CENTRAL/ PACKAGE AC PLANTS UNDER GE (NW) VASCO
Sl. No. Item Description
1M&L for cleaning of shell and tube water cooled condensers of the A/C plants of following capacities after dismantling the water lines and headers and cleaning with suitable wire brush and washing soda to remove the dirt and water scaling and refixing the water lines and headers including provision of new gaskets, etc. for following AC plants complete all as directed by Engineer-in-Charge.
2(a) 2x30 TR capacity at OLE7:E27D BMF AC plant
3(b) 3x48 TR capacity at EHU/ERS AC plant
4(c) 03x75 TR capacity at TU Hangar AC Plant
5(d) 02X37.7 TR capacity at BSF AC plant
6(e) 04 X 60 TR Capacity at MIG Simulator AC Plant
7(f) 02X12.5 TR EHU/ESSF AC plant
8(g) 03 X 25 TR capacity at Mag Guard AC Plant
9(h) 3x49.5 TR capacity at ATC AC plant
10(i) 3x49.5 TR capacity at ADR AC plant
11(j) 03x75 TR capacity at Sh Harrier Simulator AC Plant
12(k) 02X12.5 TR capacity at AL/AR AC plant
13(l) 03 X 25 TR Capacity chiller type at NTS AC Plant
14(m) 03X5.5 TR Package unit EW wksp AC plant
15(n) 02X11 TR Package unit NAY G Store AC plant
16(o) 03X5.5 TR Package unit Phone Exchange AC plant
17(p) 03X5 TR Package unit NUWR AC plant
18(q) 03X 52 TR Chiller type ILW EHU AC plant
19(r) 03X 26 TR chiller type kamov BSF AC plant
20(s) 03X5.5 TR Package unit Photo Section AC plant
21(t) 03X 52 TR chiller type ERS AC plant
22(u) 03X 5.5 TR Package type GCA AC plant
23Note : Cleaning of all units including cooling tower of an AC Plant will be treated as one job only.
24Supply and charging compressor oil of approved make including flushing/cleaning of oil chamber etc. complete all as directed by Engineer-in-Charge.
25Supply and filling Refrigerant gas R-22 for AC plant compressor complete all as specified and as directed.
26Supply and filling Refrigerant gas R-407 for AC plant compressor of any capacity or as per site requirement all as directed by Engineer-in-Charge.
27Supply and fix in repairs ball / roller bearing for pumps and motors of following capacity including taking down old bearing and re-installation at site including testing on completion
28(a) Up to 5 HP capacity
29(b) 5 to 7.5 HP capacity
30M&L for servicing Monoblock pumps including dismantling and opening the pump, repair/replacement of defective impeller, replace the worn out bearing impeller, stuffing box, back plates, gland packing mechanical seal and rusted nut, bolts etc. assembling property , greasing all movable parts, fixing in position, testing and commissioning all as directed for the following HP pumps.
31(a) 3 HP to 5 HP Pump
32(b) 7.5 HP to 10 HP Pump
33Dismantling the unserviceable electric motor any type (for pump or CT) of capacity up to 3 HP and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enameled copper winding wire of existing gauge and size with insulating materials, varnishing and baking etc. re-fixing the same at site and re-alignment, testing and commissioning complete all as directed by Engr-in-Charge.
34Dismantling the unserviceable electric motor any type (for pump or CT) of capacity up to 5 HP to 7.5 HP and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enameled copper winding wire of existing gauge and size with insulating materials, varnishing and baking etc. re-fixing the same at site and re-alignment, testing and commissioning complete all as directed by Engr-in-Charge.
35S & F in repairs condenser Monoblock water pump set 3 to 5 HP 3 phase capacity with suitable head and discharge ammunator store including necessary foundation work and electric/ water connection complete all as specified and as directed.
36Supply and fix in repair replacement of V-belt for AHU for AC Plant of size B-101 complete all as specified and as directed.
37Supply and fix in repair replacement of V-belt for AHU for AC Plant of size B-85 complete all as specified and as directed.
38Supply and fix in repair replacement of V-belt for AHU for AC Plant of size B-90 complete all as specified and as directed.
39Supply and fix in repair replacement of V-belt for AHU for AC Plant of size A-53 complete all as specified and as directed.
40Supply and fix in repair replacement of V-belt for AHU for AC Plant of size B-75 complete all as specified and as directed.
41Supply and fix in replacement of High pressure control switch as per existing make and type at site all as specified and directed by Engr-in-charge.
42Supply and fix in replacement low pressure control switch as per existing make and type at site all as specified and directed by Engineer-in-charge
43Supply and fix in replacement condenser/chilled DP flow switch as per existing make and type at site all as specified and directed by Engineer-in-charge.
44Supply and fixing in replacement of power contactor assembly including NO and NC type complete capacity up to 63 A with complete all as specified and as directed.
45Supply and fixing in replacement of insulator/connector as per existing shape and sizes complete all as specified and as directed.
46Disconnecting wiring carefully and removing defective auxiliary power contactor assembly complete and replacing by new one of same make and model, reconnecting wiring and testing on completion 400/415 volts complete all as specified and as directed.
47Supply & fixing digital type ammeter panel mounting three phase LED type 96 x 96 mm square including taking down old meter complete all as specified and as directed.
48Supply & fixing digital typer voltmeter panel mounting three phase LED 96 x 96 mm square including taking down old meter complete all as specified and as directed.
49Supply and fixing current transformer secondary current 5 Amps and primary current up to 60 Amps including taking down old current transformer complete all as specified and as directed.
50Supply and fixing in repair thermometer suitable for condenser water/ chiller line with suitable housing to mount in pipe line 0 – 100 deg C including taking down old thermostat complete all as specified and as directed.
51Supply and fixing in repair Pressure Gauge for condenser water/Chiller line with suitable housing to mount in pipe including taking down old complete all as specified and as directed.
52Supply and fixing indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V AC including taking down old lamp assembly complete all as specified and as directed.
53Supply and fixing in repair of MCCB 3 pole 415 volts AC , 100 Amps breaking capacity 16 KA complete all as directed by Engineer-in-Charge.
54Supply and fixing in repair of MCCB 3 pole 415 volts AC , 250 Amps breaking capacity 25 KA complete all as directed by Engineer-in-Charge.
55Supply and fixing in repair of MCB 4-pole 40 to 63 Amps 10 KA complete all as directed by Engineer-in-Charge.
56Supply and fixing in repair of MCB SP 06 to 32 Amps 10 KA complete all as directed by Engineer-in-Charge.
57Supply and fixing in repair of MPCB for pump of capacity upto 5 HP capacity Chiller/Compressor Pump complete all as directed by Engineer-in-Charge.
58Supply and fix in repair Motor Protection circuit breaker (MPCB) suitable for chiller/condenser pump of capacity 5 to 7.5 HP complete with over load relay , single phasing preventer under volt release in existing enclosure etc complete all as directed by Engineer-in-Charge.
59Supply and fixing in repair of stepdown Voltage transformer 240V / 24 V for HVAC panel AC plant all as specified and as directed by Engineer-In-Charge.
60S & F in repair replacement of chiller unit touch Screen display of AC Plant of capacity from 49.5 TR all as directed by Engineer-In-Charge.
61Supply and fixing electronic timer ST 100 (3 to 10 Sec) 240V or as per existing complete all as specified and directed.
62M&L for nitrogen gas testing of the following capacities of compressors, including condensing units and associated refrigerant gas piping, to detect and locate leakage. The testing shall be carried out in the presence of the Departmental Representative and completed in all respects as specified and as directed by the Engineer-in-Charge. Note :- (i) Nitrogen pressure should be held without any drop in pressure inside the unit continue for 24 hours.
63(a) 2x30 TR capacity at OLE7:E27D BMF AC plant
64(b) 3x48 TR capacity at EHU/ERS AC plant
65(c) 03x75 TR capacity at TU Hangar AC Plant
66(d) 02X37.7 TR capacity at BSF AC plant
67(e) 04 X 60 TR Capacity at MIG Simulator AC Plant
68(f) 02X12.5 TR EHU/ESSF AC plant
69(g) 03 X 25 TR capacity at Mag Guard AC Plant
70(h) 3x49.5 TR capacity at ATC AC plant
71(i) 3x49.5 TR capacity at ADR AC plant
72(j) 03x75 TR capacity at Sh Harrier Simulator AC Plant
73(k) 02X12.5 TR capacity at AL/AR AC plant
74(l) 03 X 25 TR Capacity chiller type at NTS AC Plant
75(m) 03X5.5 TR Package unit EW wksp AC plant
76(n) 02X11 TR Package unit NAY G Store AC plant
77(o) 03X5.5 TR Package unit Phone Exchange AC plant
78(p) 03X5 TR Package unit NUWR AC plant
79(q) 03X 52 TR Chiller type ILW EHU AC plant
80(r) 03X 26 TR chiller type kamov BSF AC plant
81(s) 03X5.5 TR Package unit Photo Section AC plant
82(t) 03X 52 TR chiller type ERS AC plant
83(u) 03X 5.5 TR Package type GCA AC plant
84Supply and fix in replacement of CT fan (with hub and fan blade) of capacity 30 to 75 TR cooling tower all as specified and directed by Engineer-in-Charge
85All as per item No. 37 but of AC plant of capacity 12.5 to 25 TR
86M&L for providing and fixing protective housing for cooling tower fan motor installed on top of cooling tower, fabricated from suitable heavy-duty MS/GI material, complete with weatherproof cover, structural frame, supports, fasteners, access arrangement for motor maintenance, ventilation openings/louvers and necessary protective coating/painting, including cutting, fabrication, welding, erection and fixing of all required accessories, complete in all respects as directed by the Engineer-in-Charge.
87Supply, installation, and balancing of factory fabricated galvanized steel sheet metal (G.S.S.) round / rectangular ducting of following sheet thickness having zinc coating of 120 g/m² total on both sides and complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, volume control dampers, hangers, supports, etc. as per approved drawings and conforming to the latest edition of IS 655: 2006 & HVAC Duct Construction Standards - Metal and Flexible of SMACNA along with required scaffolding work to install the ducts at site complete all as specified and directed by Engineer-in-Charge.
88(a) 22 G
89(b) 20 G Please Enable Macros to View BoQ information
90(b) 20 G Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58185555
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 95 Lakhs
LAST DATE 20-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair / Maintenance Of Central/ Package Ac Plants Under Ge (Nw) Vasco
Basic Detail
Tender No 86154/E8
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 23 Oct 2026
Submission Date 20 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 95 Lakhs
Tender Fee 1000
EMD 1.67 Lakhs
Exemption Available
Document List
86154Tender.pdf
BOQ_891925.xls
c172102a-a13a-48fb-949b-997c596450de.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
pdf

86154Tender.pdf

xls

BOQ_891925.xls

html

c172102a-a13a-48fb-949b-997c596450de.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender