Tender For Running Contract For Deposited Works Edsd-Maharajganj, Under The Jurisdiction Of Electricity Distribution Division Maharajganj, Raebareli. (Running Deposit Tender)
Tender Overview
Project Description
Tender for Running Contract For Deposited Works Edsd-Maharajganj, Under The Jurisdiction Of Electricity Distribution Division Maharajganj, Raebareli. (Running Deposit Tender)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-Nov-2026 | DATE EXTENSION 1 | Date | 11-Nov-2026 |
| 2 | 12-Nov-2026 | DATE EXTENSION 2 | Date | 17-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | The work of safe carriage of the following material from Raebareli store center to work site under the jurisdiction of Electricity Distribution Circle - 1 Raebareli . Approx. distance upto 50 Km. Including safe loading and unloading. |
| 2 | PCC Pole 8.5 meter long. |
| 3 | PCC Pole 11 meter long. |
| 4 | STP 9 Mtr Long |
| 5 | Line material i.e., cross arm/ pin insulator/stay/earthing rod/Ms Channel/MS Angle/Disc Fitting/Disc Insulators etc |
| 6 | 11 KV XLPE Cable Size 3x70sqmm |
| 7 | 11 KV XLPE Cable Size 3x120sqmm |
| 8 | ACSR Weasel Conductor |
| 9 | 3 Phase Arial Bunched Conductor |
| 10 | 11 KV Cable Box Size 3x70sqmm |
| 11 | 11 KV Cable Box Size 3x120sqmm |
| 12 | 11/0.4 KV 3 Phase 25 KVA T/F |
| 13 | 11/0.4 KV 3 Phase 63 KVA T/F |
| 14 | 11 KV Pilfer proof Metering cubical and CT PT Unit |
| 15 | The Work of safe Carriage 11 KV O/G VCB store Center Tripula Raebareli to work of site distance up to 0 to 30 km including safe loading & unloading. |
| 16 | Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms |
| 17 | PCC Pole 8.5 Mtr Long Single Pole |
| 18 | PCC Pole 8.5 Mtr Long Double Pole |
| 19 | PCC Pole 11 Mtr Long Single Pole |
| 20 | ST Pole 9 Mtr Long Single Pole. |
| 21 | Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/Concreate & sand Required as per RESSPO Norms |
| 22 | PCC Pole 8.5 Mtr Long Single Pole |
| 23 | PCC Pole 8.5 Mtr Long Double Pole |
| 24 | PCC Pole 11 Mtr Long Single Pole |
| 25 | ST Pole 9 Mtr Long Single Pole. |
| 26 | The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms |
| 27 | Dismantling of Existing Distribution Transformer forincreasing capacity/Shifting complete in all respect |
| 28 | 11/0.4 KV 3 Phase 25 KVA T/F |
| 29 | Laying, Stringing & Sagging of Following Conductorcomplete in all respect |
| 30 | ACSR Weasel Conductor |
| 31 | 3 Phase Arial Bunched Conductor |
| 32 | After Mounting of CT PT unit on double pole, laying of 50 Mtr 11 KV 3cx70 sq mm cable in single circuit on river sand form Double Pole to metering room complete in all respect. Alongwith filling of 04 nos cable jointing kits |
| 33 | Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect |
| 34 | Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides. Along with filling of 04 nos cable jointing kits |
| 35 | 11 KV XLPE Cable Size 3x70 sqmm |
| 36 | 11 KV XLPE Cable Size 3x120 sqmm |
| 37 | Hoisting of Following size 11 KV & 33 KV XLPE Cable on double pole with GI pipe of size 6 \\" dia 4 Mtr long including the jumpering complete with clamps , nut and bolts |
| 38 | 11 KV XLPE Cable Size 3x70 sqmm |
| 39 | 11 KV XLPE Cable Size 3x120 sqmm |
| 40 | Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect |
| 41 | Mounting of Following Capacity Transformers as per norms complete in all respect |
| 42 | 25 KVA T/F |
| 43 | 63 KVA T/F |
| 44 | Errection & Fixing of Cable box |
| 45 | 11 KV Cable Box Size 3x70sqmm |
| 46 | 11 KV Cable Box Size 3x120sqmm |
| 47 | Supply & Fixing of Following Items to complete the work (If Not available in stores) |
| 48 | LT Clamps |
| 49 | Nut & Bolt off size |
| 50 | F Clamp as per RESSPO Norms |
| 51 | Shackle Insulator as per RESSPO Norms |
| 52 | X-Arm Holding Clamp as per RESSPO Norms |
| 53 | clamps for top, t-off & other channel etc. |
| 54 | Three Phase Distribution Box Clamp (LS) |
| 55 | Dead End Clamp |
| 56 | Eye Hook |
| 57 | J Hook |
| 58 | Barbed Wire |
| 59 | 11 KV DO Fuse Set Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender