BOQ
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. |
| 4 | M&L for dismantling wall and ceiling boards any thickness including cover fillets complete all as specified. |
| 5 | M&L for Hi Steel Clip in false Ceiling System with Steel Tile 595 mm X 595 mm manufactured out of 0.50 mm thick polyester coil-coated Galvanized Steel having 180 gms zinc coating Coil-coated Steel tile shall have a 20-micron polyester-coated finish on front side and a backcoat of 5-micron alkyd primer. Two sides of each tile shall have raised, piped and stopped to ensure positive engagemant into the spring clip in profile allowing for demlition of individual tiles . The rgid susoension system consists two rows of 0.5mm galvanised steel clip in profile od size 38mm installed at 600mm centre to centre spacing to support the tiles.Wall suspesion Wall Suspension angles /Hangersof size 24 mm X 24 mm X 0.4 mm thick are fixed to the roof by expansion fasteners. Wall suspension angles to be made out coil coated Steel matching the color of the tile. They will be jointed to the clip-in-profilr system by hold on clamps. The Tiles/Planks shall be held in place by pressure clips as per manufacturer's instructions for spacing. in the flexible system the hanger and butterfly clip shall replace the suspension angle, complete all as specified and directed. |
| 6 | M&L for demolition of cement concrete in ground floor and paving n.exc 15 cm thick above or below ground level (unreinforced) complete all as specified and directed. |
| 7 | M&L for 75 mm thick plain cement concrete 1:3:6, type C2, using 20 mm graded stone aggregate) as in plinth protection, path etc laid in alternate bays not exc 3 m in length, complete all as specified and directed by Engr-in Charge. |
| 8 | Dismantling of wooden boarding, any description, fixed in any position with nails all as specified and directed. |
| 9 | Dismantling timber scantlings in any type of work , in any position |
| 10 | Clean sawn with butt joints Boarding, supplied & fixed with nails in any situation (except flooring and skirting) Planed both sides 20 mm thick second class soft wood |
| 11 | M&L for Timber framed and fixed Clean sawn Second class soft-wood in scantlings |
| 12 | M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil |
| 13 | Demolition Brickwork or stone/ boulder masonry, built in cement sand mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 14 | M & L for old size fly ash bricks as in brick work straight or curved on plan exceeding 6m mean radious built in CM 1:4 all as specified and directed. |
| 15 | M & L for brick work straight or curved on plan exceeding 6m mean radious built in CM 1:4 Except Brick all as specified and directed. |
| 16 | M&L for taking down chowkats or frames incl shutters (without taking off shutters from frame) n exc 1.5 Sqm complete all as specified and directed. |
| 17 | M&L for taking down chowkats or frames incl shutters (without taking off shutters from frame) exc 1.5 sqm but n exc 4 sqm each complete all as specified and directed. |
| 18 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 19 | M&L for 75 mm thick cement concrete type D-2 1:4:8 (40mm graded aggregate) as in sub base for flooring all as specified and directed |
| 20 | M&L for 25 mm thick cement concrete type B-1 1:2:4 (20mm graded aggregate) as in sub base for flooring all as specified and directed |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off the complete all as specified and directed. |
| 22 | M&L for Machine cut kota stone in flooring 18-20mm thick over and incl 20mm th cement screed base in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the floor including rubbing and polishing complete all as spd and directed. |
| 23 | M&L for Machine cut kota stone in flooring 18-20 mm thick over but in riser, skirting, dado and pillar laid over 10 mm thick rendering in cement mortar 1:4, laid and jointed with grey cement slurry including rubbing and polishing complete all as specified and directed. |
| 24 | M&L for cutting, rounding of edges and mirror polishing, of granite /marble/kota stone complete all as specified and directed. |
| 25 | M&L for Mat finish, premium quality, coloured Non -Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc. 0.18 sqm but not exceeding 0.38 sqm each , as in floors etc. set and jointed in neat cement slurry over 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match,complete all as specified and directed by Engr-in Charge Size/Shade/Colour of tile shall be approved by the AGE(I). |
| 26 | M&L for Mat finish, premium quality, coloured Non -Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc. 0.18 sqm but not exceeding 0.38 sqm each , as in skirting and pointed in white or coloured cement to match neat cement slurry over 10mm screed bed or bedding layer CM 1:3 & pointed in colour cement to match complete all as specified and as directed. |
| 27 | Box type Steel windows comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg welded to F I frame work, including other fittings; hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-026/13 sheet 1/5 to 5/5 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 28 | S&F stainless steel wire cloth 0.40 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed. |
| 29 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 30 | S&F pressed steel frame made out of MS sheet 1.25mm thick of size 125x60 mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate complete all as specified and directed. |
| 31 | M&L for cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats complete all as specified and directed |
| 32 | M&L for preparation of new steel or iron surfaces of any description, and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 33 | S&F 35mm IInd class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated |
| 34 | S&F 35mm IInd class hard wood glazed and skelton shutters 35mm thick, open rebated and prepared to receive glass or gauze etc (divided into squares) and fitted to chowkats, edges of framing plain chamfered or rounded fitted with cut and mitred bead for securing glass as specified in SSR Part-I section 8.24 (a) supplied and fitted to chowkhats with edges of sash bars and framing moulded complete all as specified and directed. |
| 35 | M&L for preparation and applying two coat of synthetic enamel paint over a coat of pink primer on new wood or wooden surfaces of any description over 10cm in width or girth not otherwise described complete all as specified and directed. |
| 36 | S& F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed. |
| 37 | S&F 200 mm long aluminium anodised barrel tower bolt of extruded section and fixed |
| 38 | M&L for 150 mm size Aluminium handle, cast type, anodised and fixed. |
| 39 | S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp and stape ( bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolt and sliding bolt of extruded section or cast aluminium alloy and fixed complete all as specified. |
| 40 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief |
| 41 | Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing but wood grain printed PVC sheet used instead of plain colour sheet |
| 42 | S&F for 300mm, Mild steel ordinary rat rail rod pattern springs including roller and roller plate complete supply & fixed complete all as specified and directed. |
| 43 | M&L for taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 44 | M&L for rendering 15mm thick cement plaster concrete surfaces or fair faces of brick work in CM (1:6) surface finished even and smooth w/o using extra cement complete all as specified. Note:- Necessary additional dubbing if required will be done by contractor and nothing extra cost is admissible in this account. |
| 45 | M&L for rendering 15mm thick (in two layer of 10mm+5mm) on brick or concrete/stone surfaces in cement mortar 1:4 surface finished even and smooth without using extra cement complete all as specified, complete all as specified and directed by Engr-in Charge. Note:- Necessary additional dubbing if required will be done by contractor and nothing extra cost is admissible in this account. |
| 46 | Supply only liquid water proofing compound. |
| 47 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bond distemper over a coat of chalk whiting 1 mm thick wall putty complete all as specified and directed. |
| 48 | M&L for preparation of newly plastered surface of wall and applying two coat of 100 % acrylic smooth emulsion exterior grade with silicon additives and anti-fengal poperties (Apex Ultima Suprema) over one coat of smartcare waterproof primer (Damp prime suprema) on walls and chajja with 10 % of dilution of water over water proof cement based putty @ 2 kg (undiluted) per Sqm of average thickness 1mm over silicon additives and sanding the surface for removal of loose particles, Tint and shed of the building as directed by Engr-in Charge. |
| 49 | M&L for 75 mm thick PCC type C2, 1:3:6 (40mm graded crushed stone aggregate) in Sub -base, floor and pavings etccomplete all as specified & directed. |
| 50 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment incl screed bed or bedding layer of mortar 20 mm thick in CM (1:6) for laying floor finishes complete all as specified & directed. |
| 51 | M&L for PCC 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 52 | M&L cement concrete 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in surface channel and drains including necessary form work complete all as specified and directed |
| 53 | Taking down carefully copper/aluminium point wiring (light ,fan,socket or power) complete fixture and fittings such as switches ,ceiling rose, regulators,sockets etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separatly) and making good disturbed surfaces of wall, floors etc. |
| 54 | M&L for point wiring in replacement with copper conductor cable multistrand, PVC unsheathed 1.5 Sqmm size FRLS for one light point controlled by one switch including one run of 1.5 Sqmm multistrand FRLS PVC unsheathed copper conductor cable for earth continuity in and including PVC casing and capping of approved size,make and quality ISI marked, including providing suitable size of copper lugs and all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading 'Point wiring' fixed on walls/ceiling including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover including taking down carefully existing old unserviceable copper/aluminium point wiring of any type (light/fan/socket or power) complete fixture and fittings such as switches ,ceiling rose, regulators,sockets etc including finishing white wash to match with existing surface all as specified and directed. |
| 55 | All as per Srl item No 54 here in before but for one 5 amps socket out let on same board. |
| 56 | All as per Srl item No 54 here in before but for one 5 amps socket out let on independent board, |
| 57 | All as per item No 54 above but for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed 2.5.0 Sqmm FRLS on independent board including one run of 2.5.0 Sqmm multistrand FRLS PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of appropriate size makes and best quality ISI marked, including CI/Pressed steel sunk box and providing suitable size of copper lugs and all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading \\"Point wiring\\" fixed on wall including sunk cast iron boxes concealing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed. |
| 58 | Supply & Fixing in replacement Switch piano, flush button, single pole one way 6 amps. |
| 59 | Supply & Fixing in replacement Socket outlet 3 pin, 6 amps flush type. |
| 60 | Supply & Fixing in replacement Switch piano, flush button, 16 amps single pole one way. |
| 61 | Supply & Fixing in replacement Socket outlet 2 in 1,3 pin 5 and 16 amps flush type. |
| 62 | Supply and fix in replacement ceiling rose 65X50 mm three terminals with back plate complete all as specified. |
| 63 | S & F in replacement of unserviceable tube light fitting with wall mounted LED integrated batten fitting inverter type 20 W LED T-5, 4 feet, 6500K ,PVC extruded.Including supply and fixing square Box and all accessories complete all as specified and as directed by Engr-in- charge. |
| 64 | Supply and fixing in replacement building security light 1x35 watt LED complete with tuff net glass protection IP 66, fixed to wall including with GI bracket made out of light grade 32 mm dia tubing up to 1.2 mtr lenth bend to shape with two sets of MS clamps made out of 25x3 mm flat iron with suitable nuts and bolts and testing complete all as specified and directed. |
| 65 | Supplying and fixing of 4 way ,double door surface/recess mounting ,vertical type ,415V ,TPN MCB distribution board of sheet steel,dust protected ,duly powder painted ,inclusive of 200 A tinned copper bus bar ,common neutral link,earth bar ,din bar for mounting MCBs(but without MCBs and incomer) as required. |
| 66 | Supplying and fixing 8 way , single pole and neutral ,sheet steel ,MCB distribution board ,240V ,on surface /recess,complete with tinned copper bus bar, neutral bus bar ,earth bar , din bar, interconnections,powder painted including earthing etc as required.(But without MCB/RCCB/Isolator) |
| 67 | Supply & Fixing in replacement MCB TPN 63 Amps 415 volts 10 KA complete with Fixing arrangement all as specified and as directed by Engr-in-charge. |
| 68 | Supply and fixing inreplacement MCB single pole and neutral 6 to 32 Amps, 240 volts complete all as specified and directed. |
| 69 | Supply and fixing inreplacement MCB single pole 6 to 32 Amps, 240 volts all as specified and directed by Engr-in-charge. |
| 70 | M & L for Sub main wiring in replacement with two single core FRLS, PVC insulated and unshseathed copper wire multistrand of size 4 sqmm along with 4.0 sqmm single core FRLS, PVC insulated and unseathed copper wire as earth wire connecting to common earth including providing suitable size of Copper lugs for connections of cable with MCBs or bus bars and including PVC casing caping of appropriate size and best quality ISI marked complete all as specified and directed.Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. |
| 71 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
| 72 | M&L for Dismantling of old Aluminium/ Copper strip of any size, complete including making good of disturbed portions of wall all as specified and directed by Engr-in-charge. |
| 73 | S&F in replcement of Aluminium strip 25x3.15 mm thick fixed with procelain/PVC saddle and fixing serew etc with minimum twonumber saddles with screws on and including PVC gutties in each one mtr of length for roof conductor and down conductors above ground, complete all as specified and directed. |
| 74 | S&F in replcement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. Screw complete including taking out old u/s test point all as specified and directed by Engineer-in-Charge. |
| 75 | Earthing complete with galvanized steel plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25mm x 4mm thick by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth test point incl necessary earth work excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber provn of RCC cover 40mm thick in 1:2:4 mix type B1 funnel with water pipe GI pipe 15mm dia medium grade as protection pipe GI earth lead all as specified. |
| 76 | S&F in replacement Air termination single pointed alumminium rod 12mm dia 300mm long fixed including taking out old air termination rod with complete fixing arrangement on top of the roof all as specified and directed by Engineer-in-Charge. |
| 77 | Deduct Credit Amount as per Schedule of credit as details given on Sal Page No 25 of tender doucments. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender