Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58176950

Tender For Construction Of Precast Reinforced Cement Concrete Drain & Providing And Laying M.S. Pipeline By Jack Pushing Technology At Shamnath Marg From Civil Lines Metro Station Gate No 1 To Ganpati Apartments Under Sub Division-4 Of Division (C&Nd

Issued by Government Departments · Delhi, Delhi
Tender Value
1.59 Crore
Estimated cost
Bid Submission
30 Oct 2026
6 days left
EMD
3.19 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Precast Reinforced Cement Concrete Drain & Providing And Laying M.S. Pipeline By Jack Pushing Technology At Shamnath Marg From Civil Lines Metro Station Gate No 1 To Ganpati Apartments Under Sub Division-4 Of Division (C&Nd)-Roads During 2025-26.

BOQ

Name of Work:- Construction of Precast RCC Drain & Providing and laying M.S. Pipeline by Jack pushing technology at Shamnath Marg from Civil Lines Metro Station Gate No 1 to Ganpati Apartments under Sub Division-4 of Division (C&ND)-Roads during 2025-26.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
2All kinds of soil
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4Centering and shuttering including strutting, propping etc. and removal of form work for :
5Foundations, footings, bases for columns.
6Centering and shuttering including strutting, propping etc. and removal of form for :
7Suspended floors, roofs, landings, balconies and access platform
8Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the Engineer-in-charge; for the following grades of concrete. Note : Extra cement upto 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
9All works up to plinth level: Concrete of M-10 grade with minimum cement content of 220 kg/cum.
10Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the Engineer-in-charge; for the following grades of concrete. Note : Extra cement upto 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
11All works up to plinth level: Concrete of M25 grade with minimum cement content of 300 kg /cum
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
13Thermo-Mechanically Treated bars of grade Fe-500D or more.
14Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement
15All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
16Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:
17Cement mortar 1:4 (1 cement : 4 coarse sand)
18Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
1912 mm cement plaster
20Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
21Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
22Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
23Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
24Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
25Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
26Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar 1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth including centring, shuttering & neat cement punning inside the bell mouth etc. all complete.
27Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.
28Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
29Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50m x 2.00m made of 40x40x6 mm angle iron or 50x50x3 mm hollow MS tube posts/ horizontal members/ bracings covered with 1.63 mm thick MS sheet. The sheet shall be fixed with 30x5 mm MS flat by suitable welding / riveting. The panels shall be made so that gap of 50 cm above the ground is available making over all height as 2.50m. MS channel ISLC 75 @ 5.70 kg/m, 50 cm long shall be provided at the bottom having oval shaped holes of size 50x25 mm at both ends with 50 cm long MS angle 40x40x6 mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250 mm long expansion fasteners at both ends.
30The work shall be executed as per drawing/ direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in- Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour, materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
31Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
32Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be madeseparately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
33Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
34Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
351000 mm dia RCC pipes. (Laying by manual/ mechanical means)
36Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the Engineer-in-charge.
37Wooven PVC cloth
38Modified Estimate Cost after correction on DSR items on a/c of [email protected] i.e. deduct for effect of correction factor on DSR Items ((1-0.973)-0.027 on (DSR Items)
39Cost Index @4.03%On DSR Item =
40Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), compacting and proper embedding/laying of inter locking paver blocks including grouting the joints with white cement mixed with matching pigments etc. complete as per the direction of Engineer-in-Charge.
4160 mm thick cement concrete inter locking paver block of M-35 grade with approved colour, design & pattern.
42Providing and laying Tactile tile (for vision impaired persons as per standards) of size 300x300x60 mm having with water absorption less than 0.5% and conforming to 1S:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc, laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
4360mm thick Tactile paver block of M-30 grade with approved colour, design & pattern.
44Providing & fixing pre-fabricated precast solid open U shaped RCC drain, drain cover, box culvert, crash barrier,retaining wall, silt chamber etc. using wet-cast technology with self-compacting concrete of grade M-50 and thermomechanically treated (TMT) steel bars of grade Fe-550D including straightening, cutting, bending, placing in position and binding, all complete upto plinth level with provisions of shear keys, connecting loops, necessary cutouts/holeslined with dowel tubes of required sizes for services with proper lifting arrangement of various thicknesses, shape and size using high quality steel molds including loading, transportation from factory to site of work,unloading,stacking at site and placing in final position with the help of required capacity cranes all complete as per IS11447:1985 and as per approved shop drawings and design mix complete as per the directions of Engineer-inCharge. The RCC precast drain along with drain cover taken together as an integrated system, shall be capable of carrying a wheel load of 5 Ton of vehicular load.
45The precast elements shall be manufactured in a controlled factory environment with approved methodology/technology having all facilities including automated steam curing, automated reinforcement cagemaking facility, NABL accredited in-house laboratory with all testing facilities etc. complete as per the directions ofEngineer-in-Charge. The installation of RCC precast drain, drain cover, box culvert etc. shall be done in correct and final position withproper line, level and plumb at site after making all arrangements of requisite T&P e.g., cranes, push-pull jacks etc. forlifting, placing and alignment of elements within erection tolerance as per IS-15916:2020, as per approved shopdrawings, complete as per direction of Engineer-in-Charge including cost of all material and all tools & machineryrequired for casting for all works up to plinth level complete as per the directions of Engineer-in-Charge.
46Providing MS pipe i/c specials of any size on ground or upto 3 Meter depth below the ground made out of 12 mm Thick MS plate i/c welding, cutting, painting both side with black anticorrosive bitumastic paint of approved brand and tested to a head of Rate 15 kg/sqm conforming to IS 3589/1981, IS 7322-1974, IS 784-1978 and relevant codes l/c cost of plate and carriage at site complete as directed by Engineer-in-Charge. (actual weight will be paid)
47Laying M.S. Pipe upto 1000 mm dia, 12 mm thick by Jack Pushing Technology directly in ground upto 3 metre depth below form ground land including necessary jointing/electric welding, coupling, etc complete as required as per direction of Engineer-in-charge.
48Carrying out subsurface survey at above mentioned across the road showing Water supply Pipelines, Sewer lines, Telecom Cables, Communication lines, drains , Gas Pipe Lines, Anchors, Oil Pipe Lines, Electric Cables, & other conduits etc. in the proposed corridor along with providing depth and dimensional details of Underground utilities and mapping as per sub surface utility Engineering-SUE ASCE 3802 & INDS TT :401-2018 (Indian Society for Trenchless Technology). The length of Route is (75*6)meter.
49Credit for old unservicable steel bars received from demolishing of RCC work as per direction of Engineer-in Charge.
50Credit of old demolished Kerb Stone etc. received after Demolishing at site all complete as per direction of Engineer-in-Charge.
51Credit of old demolished paver block etc. Received after demolishing at site all complete as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58176950
AUTHORITY Government Departments
TENDER VALUE 1.59 Crore
LAST DATE 30-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Precast Reinforced Cement Concrete Drain & Providing And Laying M.S. Pipeline By Jack Pushing Technology At Shamnath Marg From Civil Lines Metro Station Gate No 1 To Ganpati Apartments Under Sub Division-4 Of Division (C&Nd)-Roads During 2025-26.
Basic Detail
Tender No 39/SE/C and ND/PWD/2026-27 (Modified)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 23 Oct 2026
Submission Date 30 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 1.59 Crore
Tender Fee Ref. Documents
EMD 3.19 Lakhs
Exemption Not Available
Document List
4de4d845-de2a-4480-be7b-70ee2ca4ef70.html
BOQ_401016.xls
NIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

4de4d845-de2a-4480-be7b-70ee2ca4ef70.html

xls

BOQ_401016.xls

pdf

NIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender