Tender For Repair / Maintenance Of Internal Wiring, Dg Sets, Amf Panels And Other Connected Works At Balijan And Periodical Services, Sewage Maint, Garbage Collection And Upkeeping Of Garden Etc At Sb Doom Dooma Under Ge(Af) Chabua

Issued by Statutory Bodies & Commissions/Committees · Dibrugarh, Assam
Tender Value
44 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
20 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dibrugarh → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Internal Wiring, Dg Sets, Amf Panels And Other Connected Works At Balijan And Periodical Services, Sewage Maint, Garbage Collection And Upkeeping Of Garden Etc At Sb Doom Dooma Under Ge(Af) Chabua

BOQ

Name of Work:- REPAIR / MAINT OF INTERNAL WIRING, DG SETS, AMF PANELS AND OTHER CONNECTED WORKS AT BALIJAN AND PERIODICAL SERVICES, SEWAGE MAINT, GARBAGE COLLECTION AND UPKEEPING OF GARDEN ETC AT SB DOOM DOOMA UNDER GE(AF) CHABUA
Sl. No. Item Description
1Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface all as specified and directed at site.
2Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
3Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc.
4M&L for point wiring with 1.5 Sq mm single core PVC insulated FRLSH unsheathed copper multi stranded conductor in and including PVC casing capping of size 20/25mm ISI marked inclusive of tees, bend, elbows etc including sunk Anodized pressed steel box/modular sunk box 1.6 mm thick concealed in wall with white laminated colour 3 mm thick sheet cover of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm as earth wire to common earth dolly for connection to ceiling rose to earth terminal incl cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan/bell point controlled by one one way switch complete all as specified and directed at site.
5All as per ser item No.4 here-in-before but point wiring with 1.5 sqmm for one 3 pin socket outlet 5 Amps on the same board complete all as specified and directed.
6All as per ser item No.4 here-in-before but point wiring with 2.5 sqmm for one 3 pin socket outlet 5 Amps on the Independent board complete all as specified and directed.
7All as per Srl items No.4 here-in-before but point wiring with 2.5 Sqmm for 15 Amp socket out let with 2.5 sqmm earth continuity wire complete all as specified and directed.
8All as per Srl items No.4 here-in-before but point wiring with 4 Sqmm for Heater or elctric equipment/ AC 1.5 / 2 Ton / more than or equal to 3 KW load with 4.0 sqmm earth continuity wire complete all as specified and directed.
9All as per item No.4 above but for one bell/ buzzer point with 1.5 sqmm copper wire controlled by one push button on the independent board complete all as specified and directed.
10M&L for concealed point wiring with 1.5 Sq mm single core PVC insulated FRLSH unsheathed copper multi stranded conductor in and including suitable size of PVC medium grade conduit ISI marked inclusive of tees ,bend ,elbows etc including sunk Anodized pressed steel box/modular sunk box 1.6 mm thick concealed in wall with white laminated colour 3 mm thick sheet cover / suitable size of modular plate as per direction of Engr-in-Charge complete including PVC insulated multi stranded copper conductor 2.5 Sq mm as earth wire to common earth dolly for connection to ceiling rose to earth terminal incl cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan point controlled by one one way switch complete all as specified and directed at site.
11All as per ser item No.10 here-in-before but point wiring with 1.5 sqmm for one 3 pin socket out let 5 Amps on the same board complete all as specified and directed.
12All as per ser item No.10 here-in-before but point wiring with 2.5 sqmm for one 3 pin socket out let 5 Amps on the Independent board complete all as specified and directed.
13All as per Srl items No.10 here-in-before but point wiring with 2.5 Sqmm for 15 Amp socket out let with 2.5 sqmm earth continuity wire complete all as specified and directed.
14All as per Srl items No.10 here-in-before but point wiring with 4 Sqmm for Heater or elctric equipment / AC 1.5 / 2 Ton / more than or equal to 3 KW load with 4.0 sqmm earth continuity wire complete all as specified and directed.
15All as per item No.10 above but for one bell/ buzzer point with 1.5 sqmm copper wire controlled by one push button on the independent board complete all as specified and directed.
16S&F Switch Piano type single pole 5 amp 230 v complete all as specified and directed at site.
17S&F switch bell push piano type 5 amp 230 volts complete all as specified and as directed.
18S&F socket outlet 2 in 1, 5 pin, 5 amp complete all as specified and directed at site.
19S&F Switch Piano type single pole 15 amp 230 v complete all as specified and directed at site.
20S&F socket outlet 2 in 1, 6 pin, 5 and 15 amp complete all as specified and directed at site.
21S&Fixing stepped type electronic fan regulator flushType complete all as specified and directed at site.
22M&L for fancy angle holder, PVC /Polycarbonate type suitabl for B22 base LED lamp complete all as specified and directed.
23S&F call bell Ding-Dong AC, 230 volts single pole complete all as specified and as directed.
24S&F ceiling rose surface type Bakelite 65x50 mm three terminals complete all as specified and directed at site.
25S&F in repair Capacitor 4 mfd epoxy filled type copper wound complete all as specified and directed at site.
26S&F in repair Capacitor 3.15 mfd epoxy filled type copper wound complete all as specified and directed at site.
27S&F in repair Capacitor 2.5 mfd epoxy filled type copper wound complete all as specified and directed at site.
28S&F in repair socket outlet, modular type, multipurpose, multipin, 6 amps,1 module, 230 v complete all as specified and directed at site.
29S&F in repair switch modular type, one way, 10 ams, 1 module 230 v complete all as specified and directed at site.
30S&F in repair socket outlet, modular type, multipurpose, multipin, 6 amps/16 amps, 1 module, 230 v complete all as specified and directed at site.
31S&F in repair switch modular type, one way, 20 ams, 1 module 230 v complete all as specified and directed at site.
32S&F in repair modular type fan regulator,two module, 230 v complete all as specified and directed at site.
33Supply and fixing in replacement surface and wall mounted LED batten fitting energy efficient fittings 10 watt complete, inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 2/3 core 1100Volts grade all as specified and directed.
34Supply and fixing in replacement surface and wall mounted LED batten fitting energy efficient fittings 20 watt complete, inluding provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 2/3 core 1100Volts grade all as specified and directed.
35Supply and Fixing in replacement LED light fittings 36 watt Recess Mounting type , with mounting arrangement (Recess suitable for, 2x2 Grid, Hanging) Sheet aluminium housing with high quality LGP and PMMA diffuser. Separate HPF driver suitable for Armstrong and grid ceilling LED 240 volt along with fixing arrangements all as directed
36Supply and fix MCB DB SPN 4 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
37Supply and fix MCB DB SPN 6 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
38Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
39S&F in repair MCB DB TPN 4 way with metal door suitable for Provision of incomer MCB and outgoing MCB's complete all as specified and as directed.
40Supply and fix MCB DB TPN 4 way with metal door suitable for Provision of MCCB and MCB's complete all as specified and as directed.
41S&F in repair MCB SP 240 volt 6 to 32 Amps 'C' series 10 KA complete all as specified and directed at site.
42S&F in repair MCB DP 240 volt 32 Amps 'C' Series 10 KA complete all as specified and directed at site.
43S&F in repair MCB DP 240 volt 40 Amps 'C' Series 10 KA complete all as specified and directed at site.
44S&F in repair MCB DP 240 volt 63 Amps 'C' Series 10 KA complete all as specified and directed at site.
45S&F in repair MCB 4P 415 volt 40 Amps 'C' Series 10 KA complete all as specified and directed at site.
46S&F in repair MCB 4P 415 volt 63 Amps 'C' Series 10 KA complete all as specified and directed at site.
47S&F in repair MCCB 63 Amps, 415 V, 16KA 4 pole with thimbles/lugs and nut, bolts complete all as specified and as directed.
48Supply and fixing in replacement surface wall mounted energy efficient LED batten 20 watt, surge protection 2.5 Kv, inluding provision of PVC insulated sheathed round flexible wire complete all as specified and directed.
49M&L for sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface with PVC Casing caping as per site requirement with 2 x 1.5 sq mm + 1 x 1.5 sqmm earth wire complete all as specified and directed.
50M&L for sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface with PVC Casing caping as per site requirement with 2 x 4.0 sq mm + 1 x 4 sqmm earth wire complete all as specified and directed.
51M&L for sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface with PVC casing capping as per site requirement with 2 x 6.0 sq mm + 1x 6 sqmm earth wire complete all as specified and directed.
52M&L for concealed sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in PVC Conduit of size 20/25 mm as required with 2 x 4.0 sq mm + 1x 4 sqmm earth wire complete all as specified and directed.
53M&L for concealed sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in PVC Conduit of size 20/25 mm as required with 2 x 6.0 sq mm + 1x 6 sqmm earth wirecomplete all as specified and directed.
54Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed at site.
55Supply and fix exhaust fan, steel body AC Single Phase, 230 V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed at site.Note : Old unsv exhaust fan will be deposited to MES store yard.
56Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed at site.Note : Old unsv ceiling fan will be deposited to MES store yard Please Enable Macros to View BoQ information
57Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed at site.Note : Old unsv ceiling fan will be deposited to MES store yard Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58176779
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44 Lakhs
LAST DATE 13-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Internal Wiring, Dg Sets, Amf Panels And Other Connected Works At Balijan And Periodical Services, Sewage Maint, Garbage Collection And Upkeeping Of Garden Etc At Sb Doom Dooma Under Ge(Af) Chabua
Basic Detail
Tender No 861
Bidding Type Tender
Location
City Dibrugarh
State Assam
Key Dates
Publish Date 23 Oct 2026
Submission Date 13 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 44 Lakhs
Tender Fee 500
EMD 88000
Exemption Available
Document List
83a21d65-ea2e-4da1-9d63-4140bb11de05.html
BOQ_892102.xls
generalpage.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 28 days

Tender Documents

Download All (ZIP) ↓
html

83a21d65-ea2e-4da1-9d63-4140bb11de05.html

xls

BOQ_892102.xls

pdf

generalpage.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender