Tender For Provn Of Storage Shed For periodical renewal Equipment At Cg Jetty Under Ge Haddo Sri Vijayapuram.
Tender Value
43.50 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
11 days left
EMD
87000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Storage Shed For periodical renewal Equipment At Cg Jetty Under Ge Haddo Sri Vijayapuram.
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out Soft/loose soil, etc complete all as specified. |
| 2 | Excavation in trenches for foundation n.exc 1.5 meter wide and n exc. 1.5 meter depth and not exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in approved earth including spreading, levelling watering and well ramming in layers n.exc 25cm in foundation in hard/dense soil complete all as specified and directed. |
| 4 | Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mm above the starting point complete all as specified and directed. |
| 5 | M&L for cement concrete 1:4:8 type D2, using 40mm graded stone aggregate in foundation filling and mass concrete etc, complete all as specified and as directed. |
| 6 | M&L for providing PCC 1:3:6 type C2 (using 40mm graded stone agg) as in plinth protection 75 mm thick finished over and smooth without using extra cement etc all as specified and directed. |
| 7 | Material and labour for precast cement concret block masonary 1:3:6 type C1 using 20mm graded stone agg with solid blocks, exc 10cm in width and setting in CM 1:6 etc, complete all as specified and as directed. |
| 8 | Material and labour for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding15 cm thick, watered and rammed to a true surface, etc complete all as specified. |
| 9 | M&L for providing plain cement concrete 1:4:8 type D-2 (using 40mm graded stone agg) as in sub-base of floor, 100mm thick etc all as specified and directed. |
| 10 | M&L for providing PCC 1:2:4 type B2 (using 40mm graded stone agg) as in floor finished, 50 mm thick etc all as specified and directed. |
| 11 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc,completed all as specified and directed. |
| 12 | M&L for Reinforced cement concrete Type B1,1:2:4 using 20mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc all as specified and directed. |
| 13 | M&L for use of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, and similar works for rough finished flat concrete surfaces all as specified and directed. |
| 14 | Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips etc, complete all as specified and as directed. |
| 15 | Material and labour for Mild steel TMT bars of Fe 500 or Fe 500D, 8 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips etc, complete all as specified and as directed. |
| 16 | Supply and fix roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde E- 250) quality A etc, complete all as specified and as directed. |
| 17 | Material and labour mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 etc, complete all as specified and as directed. |
| 18 | Supply and fix mild steel screw bolts (machine made) of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 10 cm but not exceeding 15 cm etc, complete all as specified and as directed. |
| 19 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, complete all as specified and as directed. |
| 20 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc, complete all as specified and directed. |
| 21 | M&L for Aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering etc fixed with self tapping screws etc, complete all as specified and as directed. |
| 22 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including all necessary fittings etc, complete all as specified and as directed. |
| 23 | S&F PVC (SWR) bends any radius, 110mm bore etc, complete all as specified and as directed. |
| 24 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or PCC block masonry or concrete surfaces finished even and smooth without using extra cement etc, complete all as specified and as directed. |
| 25 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc, complete all as specified and as directed. |
| 26 | M&L for preparation of new steel surfaces of any description exc 10 cm width or girth when unconnected with other Painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer etc, complete all as specified and as directed. |
| 27 | M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces. |
| 28 | All as per item Sl No 27 above, but, for One light/fan point controlled by one modular switch 6 Amps one way complete all as specified and directed. |
| 29 | All as per item Sl No 27 above, but , for one modular 3 pin 6 Amp socket out let on independent board complete all as specified and directed. |
| 30 | All as per item Sl No 27 above, but, for one modular 3 pin 6 Amps socket outlet on same Board complete all as specified and directed. |
| 31 | All as per item Srl No.27 above, but , point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed. |
| 32 | S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed. |
| 33 | S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed. |
| 34 | S & F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed. |
| 35 | S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16 Amp , universal complete all as specified and directed. |
| 36 | S & F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete all as specified and as directed. |
| 37 | Supply and fixing LED lights fitting 1x 22W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-charge |
| 38 | Supply and fix medium bay/high bay light 100 watts made of high pressure aluminium die cast high transmittance tempered glass cover and control accessories complete set PF>0.95 and fittings accessories including 3 core copper cable of size 2.5 sq mm connection complete having IP 65 rating with high efficacy 100 lumens /watt suitable for working on 230 volts 50 Hz supply complete all as specified and directed. |
| 39 | S & F GI brackets of GI pipe light grade of size 32 mm dia including nuts, bolts and washers for building secufity light all as specified and directed |
| 40 | S & F 30/35 watts LED building security light fittings , pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 with pranuts including necessary fixing arrangements as per site requirements class all as specified and directed by Engr In charge. |
| 41 | M& L sub main wiring with 2 single core 4.0 sq mm duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire complete all as specified and directed.Note : 3 length of cable and one length casing & caping shall be measured and paid for one length . |
| 42 | S & F Triple pole and neutral sheet steel powder coated Distribution board IP -54 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door TP&N DB system 04 ways,and making good to the distrubed surface /walls complete all as specified and directed. |
| 43 | Supplying & fixing MCB TPN 63 Amps having current rating 10 KA complete all as specified and directed . |
| 44 | Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.Note:- All copper conductors should be connected with MCCB/ MCB alongwith copper reducer terminals of suitable size duly crimpled.” |
| 45 | Supply and lay cable in trenches/pole/wall/pcc etc 16 Sqmm 4 core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor complete all as specified and directed. |
| 46 | Supply and laying in trenches/wall/pole/pcc DWC HDPE pipe of size 50mm(OD)x38 mm(ID) along with connected accessories with couplers bends ,end caps etc for LT cable protection all as specified and directed. |
| 47 | Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / pole and getting out in the hard/dense soil complete all as specified and as directed. |
| 48 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed. |
| 49 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed. |
| 50 | Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 20 mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. |
| 51 | Supply and fix earth continuity conductor 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles complete all as specified and as directed by Engineer-in-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysNov 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender